}

Increase Load Capacity Of 11/0.04 Substation And Installation Of New Transformer And Other Electric Works Under Business Plan2025-26 Under Jurisdiction Of Edc, Rampur., rampur-Uttar Pradesh

Paschimanchal Vidyut Vitran Nigam Limited has published Increase Load Capacity Of 11/0.04 Substation And Installation Of New Transformer And Other Electric Works Under Business Plan2025-26 Under Jurisdiction Of Edc, Rampur.. Submission Date for this Tender is 16-09-2025. Wall construction Tenders in rampur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

50922996
Increase Load Capacity Of 11/0.04 Substation And Installation Of New Transformer And Other Electric Works Under Business Plan2025-26 Under Jurisdiction Of Edc, Rampur.
Tender
Indian
Uttar Pradesh
Rampur
16-09-2025

Tender Details

Increase load Capacity of 11/0.04 Substation and Installation of new transformer and other electric works under Business Plan2025-26 under jurisdiction of EDC, Rampur.- 1 Carriage of the following material from Store Centre, Rampur to work site including loading & unloading. 2 PCC Pole 11 Mtr Long 3 Polymeric 11 KV Pin Insulator 4 Disc fitting 11 KV 5 Disc insulator 11 KV 6 Earthing of Pole 7 Top Channel 100*50*2400mm 8 Dropper Channel 100*50*32mm 9 T-Off Channe, 100x50x2240mm 10 T-Off Channe, 125x65x1300mm 11 Stay set Complete 12 250 KVA T/F 13 11 KV Fuse Set 14 LT Incoming Pannel with Metering Equipments 15 LT PVC Cable 3.5x150/70 SQmm 16 LT PVC Cable 3.5x400 SQmm 17 LT PVC Cable 1x240 SQmm 18 LT ABC3x120 Sqmm Cable 19 ACSR Weasel Conductor 20 100 KVA Transformer (Recived Back Site to Store) 21 AI Scrap (in KG)(Recived Back Site to Store) 22 Double Pole StructureExcavation of foundation Pit in size of 75x45cm having depth of 1/6th of the full length of the support(pole), providing and laying of stone pad (300x300x75 mm) in the Bottom of the pit. Erection of support(pole) complete with fixing of 11 KV V-type cross-Arms and other accessories by providing clamps made of MS flat of size 65x65xc6 mm with Nuts & Bolts, as per RESPO Norms. 23 11 Mtrlong PCC Pole 24 Grouting of support in CC 1:4:8(cement, sand & 40 mm. brick ballast) Grouting will be done in the block of size 45x45cmx1/6th of full length of the support upto ground level, 30 cm plinth above the ground level with CC 1:3:6 (cement, course sand and stone grit) with muffing. The work includes back filling and proper ramming etc. Double Pole Structure 25 11 Mtrlong PCC Pole 26 Grouting of Stay Rods(20x1800)mm including all work of excavation, cement concrete in size of (0.60x0.60x0.30)M in the ratio of 1:4:8(cement, sand, 40mm brick ballast) including back filling of soil and proper ramming etc. 27 Fixing, tightening and nozelling of stay wire with stay rod with the pole of required tension by providing stay clamps. 28 Earthing of support with MS Earth Rod of (20x2500)mm long including excavation of pit and driving MS Rod 3.0 M apart from support and 0.5 M below the ground level and connecting below the earth electrodes with the help of GI wire No. 8SWG and earthing lugs. 29 fixing of 11 KV Pin Insulator with Pin as per RESPO Norms and as per direction of Supervising Engineer. 30 fixing of 11 KV Disc Insulator with Fitting as per RESPO Norms and as per direction of Supervising Engineer. 31 laying,stringing and binding of LT PVC Cable 3.5x150/70 SQmm as per RESPO Norms and as per direction of Supervising Engineer. 32 laying,stringing and binding of ACSR Weasel Conductor as per RESPO Norms and as per direction of Supervising Engineer. 33 laying,stringing and binding of LT PVC Cable 3.5x400 SQmm as per RESPO Norms and as per direction of Supervising Engineer. 34 Laying,stringing and binding of LT PVC Cable 1x240 SQmm as per RESPO Norms and as per direction of Supervising Engineer. 35 Laying,stringing and binding of laying LT ABC3x120 Sqmm Cable as per RESPO Norms and as per direction of Supervising Engineer. 36 Dismentalling of old T/F and installation/Mounting of 250 KVA T/F as per RESPO Norms and as per direction of Supervising Engineer. 37 Installing of 11 KV fuse set as per RESPO Norms and as per direction of Supervising Engineer. 38 fixing ofLT Incoming Panel with Metering Equ as per RESPO Norms and as per direction of Supervising Engineer. 39 Providing and fixing Al Leg long Barrel of Size per RESPO Norms and as per direction of Supervising Engineer 40 Providing and fixing of Suspension Clamp with I Hook asper RESPO Norms and as per direction of Supervising Engineer 41 Making of Plinth for T/F Size 2x2x1.5Mtr asper RESPO Norms and as per direction of Supervising Engineer(complete material provide by contractor) 42 Fencing of T/Fper RESPO Norms and as per direction of Supervising Engineer(complete material provide by contractor) 43 Providing and fixing 4 Core LT MCB with Box as per RESPO Norms and as per direction of Supervising Engineer 44 Providing and fixing Danger Board with clamp per RESPO Norms and as per direction of Supervising Engineer 45 Providing and fixing Stone Pad per RESPO Norms and as per direction of Supervising Engineer 46 Providing and fixing LT Clamp RESPO Norms and as per direction of Supervising Engineer 47 Providing and fixing PG clamp RESPO Norms and as per direction of Supervising Engineer 48 Providing and fabrication, Complete installation of Henley type Tailless Fuse Unit frame made of 70cm x 50cmx 6 mm, M.S. Angle with fixing500 Amp with copper Bus Bar. Fabrication and fixing of all bus bar of size 400mm x 50 mm x10mm and then grouting Tailless frame on the plinth of T/f with making the connection at T/f with earthing and Line side complete work all material shall be provided by the contractor. Cable for connection will be provided by the Department. 49 Providing and fixing Dead end Clamp with I Hook asRESPO Norms and as per direction of Supervising Engineer 50 Providing and fixing of LT piercing Connector as perRESPO Norms and as per direction of Supervising Engineer 51 Providing and fixing Copper L Piece 62x225x12 mm as per RESPO Norms and as per direction of Supervising Engineer 52 Providing and fixing Copper L Piece 50x225x10 mm as per RESPO Norms and as per direction of Supervising Engineer 53 Dismentaling ofold and used AI Scrap as RESPO Norms and as per direction of Supervising Engineer

Key Value

Document Fees
INR 3540 /-
EMD
INR 11000.0 /-
Tender Value
INR 10.54 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail