| 1 | 1 SPAN OF 70 MTR 11 KV LINE ON H-Beams 13 Mtr. FOR ROAD CROSSING (OVER HEAD) EXCLUDING NATIONAL HIGHWAY(NH) & STATE HIGHWAY (SH) |
| 2 | Back Clamps for H-Beam of MS Flat 65x8mm (Each weight 1.92 Kg) |
| 3 | Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire |
| 4 | 11 KV Pin Insulator Polymer Composit (5 KN) |
| 5 | Carpet guarding |
| 6 | Jointing Sleeves suitable for Dog (100Sq.mm.Al. Eq. ) AAAC conductor |
| 7 | Stay set 20 mm. complete without Stay wire (Painted) |
| 8 | STAY GI WIRE 7/4.00 MM.(7/8 SWG) |
| 9 | Clamp 65X8 mm Flat of MS Flat for H-Beam ( Each weight 3.2 kg) |
| 10 | Stone Block/Pre cast block for base pedding(450X450X75MM) |
| 11 | Concreting of structures & foundation (1:3:6) |
| 12 | Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay |
| 13 | Red oxide paint |
| 14 | Aluminium paint |
| 15 | Danger Boards Enamelled 11 KV |
| 16 | Aluminium Binding wire and tape |
| 17 | M.S.Nuts with Bolts |
| 18 | M S Angle 65X65X6 mm |
| 19 | WPB160x160mm,30.44 Kg/Meter H beam,13 mtr long |
| 20 | Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) |
| 21 | Schedule for 11 KV Single Pole Cut Point in 8 M PCC pole for Straight Line & angle upto 45 degree for Urban Area |
| 22 | 11 KV Pin Insulator Polymer Composit (5 KN) |
| 23 | 11 KV(45KN) Composite Polymer Disc Insulators |
| 24 | 11 KV Strain hardware (T&C type) fittings |
| 25 | MS strain plate 65x8mm 250mm long |
| 26 | STAY GI WIRE 7/4.00 MM.(7/8 SWG) |
| 27 | Clamp for 140 Kg PCC Pole MS Flat 50x6 mm |
| 28 | Back Clamp for 140 Kg PCC Pole MS Flat 50x6 mm |
| 29 | Back filling of poles with boulders. |
| 30 | Concreting of structures & foundation (1:3:6) |
| 31 | Red oxide paint |
| 32 | Aluminium paint |
| 33 | M.S.Nuts with Bolts |
| 34 | AAAC Rabbit conductor 0.05 sq. inch. (55 sq.mm. Al.Eq.) |
| 35 | M S Channel 100X50x6 mm |
| 36 | One KM. L.T. LINES 3 PHASE 5 WIRE ON PCC 8 M USING 1100 Volts Grade A.B. Cable 3 X 25+1x16+1x35 Sq.mm. XLPE WITH MAXIMUM SPAN OF 50 METERS |
| 37 | 140 Kg.,8.0 Mtrs. long PCC pole |
| 38 | LT A.B Cable tension clamps (Galvanized) |
| 39 | LT A B cable Suspension clamps (Galvanized) |
| 40 | Clamps for neutral for AB Cable |
| 41 | Piercing connector Type-I for single/three phase (Main 16-50 sqmm tap-off 16-50 sqmm) |
| 42 | Piercing connector Type-II (Main 16-50 sqmm tap-off 16-50 sqmm) |
| 43 | LT Aerial bunched XLPE Cable 3 X 25+ 1 X 16+ 1 X 25 sqmm with aluminium alloy Bare messenger wire |
| 44 | Stay set complete without Stay wire 16 mm. (Painted) |
| 45 | STAY WIRE 7/3.15 MM.(7/10 SWG) |
| 46 | Clamp for 140 Kg PCC Pole MS Flat 50x6 mm |
| 47 | Stay Insulators 90X65mm |
| 48 | Back filling of poles with boulders. |
| 49 | Stone Block/Pre cast block for base pedding(450X450X75MM) |
| 50 | Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay |
| 51 | M.S.Nuts with Bolts |
| 52 | Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire |
| 53 | Earthing for PCC Pole 4.00 mm-8 SWG G.I wire- 0.8 Kg, per pole |
| 54 | Single Phase Service connection box (Deep Drwan Metal Service Connection Boxes )with one incoming up to 25 mm2 and 8 no outgoing up to 10 mm2 with insulated multiple outgoing connector- |
| 55 | Three Phase Service connection box(Deep Drwan Metal Service Connection Boxes ) with one incoming up to 35 mm2 and 4 no outgoing up to 16 mm2 with insulated multiple outgoing connector- |
| 56 | LED Lamp with 9 Watt (Complete) |
| 57 | PVC Bush |
| 58 | Single phase Electronic meter with data downloading facility & box 5-30 Amps. |
| 59 | PVC 2 CORE UN ARMOURED 2.5 SQMM ALUMINIUM CONDUCTOR |
| 60 | Switch Board |
| 61 | Rack Bolt/Screw |
| 62 | 3 Pin 5A Socket (Two no. Piano type switch, Bulb Bakelite Holder with wiring & E |
| 63 | Wooden Board 10\"x8\" |
| 64 | 11/0.4 KV, 25KVA OUT DOOR SUB-STATION (ON PCC POLE ) |
| 65 | 140 Kg.,8.0 Mtrs. long PCC pole |
| 66 | 11 KV(45KN) Composite Polymer Disc Insulators |
| 67 | 11 KV Strain hardware (T&C type) fittings |
| 68 | Back Clamp for 140 Kg PCC Pole MS Flat 50x6 mm |
| 69 | 11 KV D.O. Fuse Unit Polymer type |
| 70 | 9 KV Gapless type ( 5KA) Polymer for DTR |
| 71 | Stay set complete without Stay wire 16 mm. (Painted) |
| 72 | STAY WIRE 7/3.15 MM.(7/10 SWG) |
| 73 | Stay Insulators 90X65mm |
| 74 | Clamp for 140 Kg PCC Pole MS Flat 50x6 mm |
| 75 | Stone Block/Pre cast block for base pedding(450X450X75MM) |
| 76 | Concreting of structures & foundation (1:3:6) |
| 77 | Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay |
| 78 | Complete jumpering of DTR |
| 79 | Danger Boards Enamelled 11 KV |
| 80 | Bi-metallic clamps Distribution Transformers Bushing |
| 81 | Bi-metallic clamps suitable for 12mm dia stud and 80sqmm AAAC |
| 82 | Red oxide paint |
| 83 | Aluminium paint |
| 84 | M.S.Nuts with Bolts |
| 85 | Meter cum protection box for 25 KVA DTR |
| 86 | Three phase Static Energy meters 20-80 Amps.with L.S. & TOD Facility with box |
| 87 | G.I. STRIP 25X3 MM1 |
| 88 | G.I.Pipe 40 mm Dia C grade type |
| 89 | Bentonite compound powder |
| 90 | Galvanized nut & bolt with washer |
| 91 | M S Channel 75X40x6 mm |
| 92 | XLPE Cable 1 core unarmoured 70 sqmm Aluminium conductor 1100 Volts |
| 93 | Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) |
| 94 | M S Channel 100X50x6 mm |
| 95 | 11/0.4 KV Distribution transformer 25 KVA (Conventional) (Aluminium wound)(Rep-BGP) |
| 96 | M.S.Angle 50x50x6 mm |
| 97 | AAAC Rabbit conductor 0.05 sq. inch. (55 sq.mm. Al.Eq.) |
| 98 | XLPE Cable 1 core unarmoured 35 sqmm Aluminium conductor 1100 Volts |
| 99 | Additional Erection Charge |
| 100 | Additional Erection Charge |
| 101 | Other Charges |
| 102 | TOTAL COST WITHOUT GST |
| 103 | GST |