| 1 | Carriage of following material from store center PVVNL to site & vice-versa of work including loading & unloading at both ends maximum distance up to 100 Km. :-EDD-Partapur, Meerut |
| 2 | ST/PCC Pole 11 Mtr. Long |
| 3 | PCC Pole 8.5 mtr long |
| 4 | ACSR Weasal Conductor |
| 5 | 11 KV Pin Insulator with pin |
| 6 | 11 KV Disc Insulator with fitting |
| 7 | LT AB Cable 3x95 sq.mm |
| 8 | 250 KVA T/F 11/0.4V |
| 9 | 11 KV Fuse set |
| 10 | Stay set |
| 11 | Earthing rod |
| 12 | Errection ST/PCC Pole 11 mtr long/PCC pole 8.5 mtr long after digging a pit of size 1.6 mtr deep in all type of Soil including grouting ratio (1:4:8) of the pole with proper ramming after completion of work. (as per UPPCL Respo). |
| 13 | Errection of Double PCC Pole 11 mtr long/PCC pole 8.5 mtr long after digging a pit of size 1.20x0.60x1.6 mtr in all type of Soil for each pole including grouting ratio (1:4:8) of the pole with proper ramming after completion of work. (as per UPPCL Respo). |
| 14 | Laying, lifting of LT AB Cable 3x95. (As Per Direction of Supervising Engineer). |
| 15 | Laying of ACSR Weasal Conductor for jumpering. (As Per Direction of Supervising Engineer). |
| 16 | Fixing of Stay rod complete as per norms.(As Per Direction of Supervising Engineer). |
| 17 | Fixing of MS Earthing of each 11 KV line and pole after drive of electrodes if size 20mm x 250 mm and connection the earthing point with GI wire. (As Per Direction of Supervising Engineer). |
| 18 | Providing and Fixing of MS Nut and Bolts.(as per UPPCL Respo). |
| 19 | Providing and Fixing Clamp with nut and bolt. (as per UPPCL Respo). |
| 20 | Making of New 250 KVA T/F Plinth of size 6\"x6\"x3\" (feet).(as per UPPCL Respo). |
| 21 | New Wiremesh Fencing of 250 KVA T/F. (as per UPPCL Respo). |
| 22 | Providing and Fixing 2\" dia GI Pipe upto 80 feet Water level earthing 250 KVA T/F (Neutral and Body) (as per UPPCL Respo). |
| 23 | Providing and Fixing of Dropper Channel. (as per UPPCL Respo). |
| 24 | Fixing of 11 KV Fuse Set. (As Per Direction of Supervising Engineer). |
| 25 | Providing and Fixing of Fixing of Top channel. (as per UPPCL Respo). |
| 26 | Providing and Fixing of Fixing of T-off channel.(as per UPPCL Respo). |
| 27 | Providing and Fixing of Piercing Clamp. (as per UPPCL Respo). |
| 28 | Providing and Fixing of Suspension Clamp. (as per UPPCL Respo). |
| 29 | Providing and Fixing of Dead and Clamp(as per UPPCL Respo). |
| 30 | Providing and fixing of Stone Pad (as per UPPCL Respo). |
| 31 | Providing and fixing of Tailless Unit (as per UPPCL Respo). |
| 32 | Providing and fixing of Danger Board (as per UPPCL Respo). |
| 33 | Providing and fixing of Copper L-piece 50x225x10mm (LS) (as per UPPCL Respo). |
| 34 | Providing and fixing of Copper L-piece 62x225x12mm (LS) (as per UPPCL Respo). |
| 35 | Grouting of Stay set (As Per Direction of Supervising Engineer). |
| 36 | Providing and Fixing of MS Angle 65x65x6 sq.mm |
| 37 | Fixing of 11 KV Pin Insulator with pin (As Per Direction of Supervising Engineer). |
| 38 | Fixing of 11 KV Disc Insulator with fitting (As Per Direction of Supervising Engineer). |
| 39 | Carriage of following material from store center PVVNL to site & vice-versa of work including loading & unloading at both ends maximum distance up to 100 Km. :-EDD-Pallavpurm, Meerut |
| 40 | ST/PCC Pole 11 mtr long |
| 41 | PCC Pole 8.5 mtr long |
| 42 | ACSR Weasal Conductor |
| 43 | 11 KV Pin Insulator with nut and bolt |
| 44 | 11 KV Disc Insulator with nut and bolt |
| 45 | LT AB Cable 3x95 sq.mm |
| 46 | 250 KVA T/F 11/0.4V |
| 47 | 100 KVA T/F 11/0.4V |
| 48 | 11 KV Fuse set |
| 49 | Stay set |
| 50 | Top Channel |
| 51 | Dropper Channel |
| 52 | T-off channel |
| 53 | MS Angle 65x65x6 mm |
| 54 | Earthing rod |
| 55 | Errection ST/PCC Pole 11 mtr long/PCC pole 8.5 mtr long after digging a pit of size 1.6 mtr deep in all type of Soil including grouting ratio (1:4:8) of the pole with proper ramming after completion of work. (as per UPPCL Respo). |
| 56 | Errection of Double PCC Pole 11 mtr long after digging a pit of size 1.20x0.60x1.6 mtr in all type of Soil for each pole including grouting ratio (1:4:8) of the pole with proper ramming after completion of work. (as per UPPCL Respo). |
| 57 | Laying, lifting of LT AB Cable 3x95. (As Per Direction of Supervising Engineer). |
| 58 | Laying of ACSR Weasal Conductor for jumpering. (As Per Direction of Supervising Engineer). |
| 59 | Fixing of Stay rod complete as per norms.(As Per Direction of Supervising Engineer). |
| 60 | Fixing of MS Earthing of each 11 KV line and pole after drive of electrodes if size 20mm x 250 mm and connection the earthing point with GI wire. (As Per Direction of Supervising Engineer). |
| 61 | Providing and Fixing of MS Nut and Bolts. (as per UPPCL Respo). |
| 62 | Providing and Fixing Clamp with nut and bolt (as per UPPCL Respo). |
| 63 | Providing and Fixing 2\" dia GI Pipe upto 80 feet Water level earthing 250 KVA T/F (Neutral and Body) (as per UPPCL Respo). |
| 64 | Making of New 250 KVA T/F Plinth of size 6\"x6\"x3\" (feet) (as per UPPCL Respo). |
| 65 | New Wiremesh Fencing of 250 KVA T/F. (as per UPPCL Respo). |
| 66 | Fixing of Dropper Channel. (As Per Direction of Supervising Engineer). |
| 67 | Fixing of 11 KV Fuse Set. (As Per Direction of Supervising Engineer). |
| 68 | Fixing of Top channel. (As Per Direction of Supervising Engineer). |
| 69 | Fixing of T-off channel. (As Per Direction of Supervising Engineer). |
| 70 | Providing and Fixing of Piercing Clamp. (as per UPPCL Respo). |
| 71 | Providing and Fixing of Suspension Clamp. (as per UPPCL Respo). |
| 72 | Providing and Fixing of Dead and Clamp(as per UPPCL Respo). |
| 73 | Providing and fixing of Stone Pad (as per UPPCL Respo). |
| 74 | Providing and fixing of Tailless Unit (as per UPPCL Respo). |
| 75 | Providing and fixing of Danger Board (as per UPPCL Respo). |
| 76 | Providing and fixing of Copper L-piece 50x225x10mm (LS) (as per UPPCL Respo). |
| 77 | Providing and fixing of Copper L-piece 62x225x12mm (LS) (as per UPPCL Respo). |
| 78 | Providing Rex Oxide Paint (As Per Direction of Supervising Engineer). |
| 79 | Providing Aluminium Paint (As Per Direction of Supervising Engineer). |