Tender For Work Related To Installation Of Additional Transformers Etc. In The Jurisdiction Of Subordinate Sub-Divisions Of Electricity Distribution Division-Partapur And Pallavpuram, Meerut Under The Business Plan For The Year 2025-26.
Tender Overview
Project Description
Tender For Work related to installation of additional transformers etc. in the jurisdiction of subordinate sub-divisions of Electricity Distribution Division-Partapur and Pallavpuram, Meerut under the Business Plan for the year 2025-26.
BOQ
| Sl. No. | Item Description |
| 1 | Carriage of following material from store center PVVNL to site & vice-versa of work including loading & unloading at both ends maximum distance up to 100 Km. :-EDD-Partapur, Meerut |
| 2 | ST/PCC Pole 11 Mtr. Long |
| 3 | PCC Pole 8.5 mtr long |
| 4 | ACSR Weasal Conductor |
| 5 | 11 KV Pin Insulator with pin |
| 6 | 11 KV Disc Insulator with fitting |
| 7 | LT AB Cable 3x95 sq.mm |
| 8 | 250 KVA T/F 11/0.4V |
| 9 | 11 KV Fuse set |
| 10 | Stay set |
| 11 | Earthing rod |
| 12 | Errection ST/PCC Pole 11 mtr long/PCC pole 8.5 mtr long after digging a pit of size 1.6 mtr deep in all type of Soil including grouting ratio (1:4:8) of the pole with proper ramming after completion of work. (as per UPPCL Respo). |
| 13 | Errection of Double PCC Pole 11 mtr long/PCC pole 8.5 mtr long after digging a pit of size 1.20x0.60x1.6 mtr in all type of Soil for each pole including grouting ratio (1:4:8) of the pole with proper ramming after completion of work. (as per UPPCL Respo). |
| 14 | Laying, lifting of LT AB Cable 3x95. (As Per Direction of Supervising Engineer). |
| 15 | Laying of ACSR Weasal Conductor for jumpering. (As Per Direction of Supervising Engineer). |
| 16 | Fixing of Stay rod complete as per norms.(As Per Direction of Supervising Engineer). |
| 17 | Fixing of MS Earthing of each 11 KV line and pole after drive of electrodes if size 20mm x 250 mm and connection the earthing point with GI wire. (As Per Direction of Supervising Engineer). |
| 18 | Providing and Fixing of MS Nut and Bolts.(as per UPPCL Respo). |
| 19 | Providing and Fixing Clamp with nut and bolt. (as per UPPCL Respo). |
| 20 | Making of New 250 KVA T/F Plinth of size 6\"x6\"x3\" (feet).(as per UPPCL Respo). |
| 21 | New Wiremesh Fencing of 250 KVA T/F. (as per UPPCL Respo). |
| 22 | Providing and Fixing 2\" dia GI Pipe upto 80 feet Water level earthing 250 KVA T/F (Neutral and Body) (as per UPPCL Respo). |
| 23 | Providing and Fixing of Dropper Channel. (as per UPPCL Respo). |
| 24 | Fixing of 11 KV Fuse Set. (As Per Direction of Supervising Engineer). |
| 25 | Providing and Fixing of Fixing of Top channel. (as per UPPCL Respo). |
| 26 | Providing and Fixing of Fixing of T-off channel.(as per UPPCL Respo). |
| 27 | Providing and Fixing of Piercing Clamp. (as per UPPCL Respo). |
| 28 | Providing and Fixing of Suspension Clamp. (as per UPPCL Respo). |
| 29 | Providing and Fixing of Dead and Clamp(as per UPPCL Respo). |
| 30 | Providing and fixing of Stone Pad (as per UPPCL Respo). |
| 31 | Providing and fixing of Tailless Unit (as per UPPCL Respo). |
| 32 | Providing and fixing of Danger Board (as per UPPCL Respo). |
| 33 | Providing and fixing of Copper L-piece 50x225x10mm (LS) (as per UPPCL Respo). |
| 34 | Providing and fixing of Copper L-piece 62x225x12mm (LS) (as per UPPCL Respo). |
| 35 | Grouting of Stay set (As Per Direction of Supervising Engineer). |
| 36 | Providing and Fixing of MS Angle 65x65x6 sq.mm |
| 37 | Fixing of 11 KV Pin Insulator with pin (As Per Direction of Supervising Engineer). |
| 38 | Fixing of 11 KV Disc Insulator with fitting (As Per Direction of Supervising Engineer). |
| 39 | Carriage of following material from store center PVVNL to site & vice-versa of work including loading & unloading at both ends maximum distance up to 100 Km. :-EDD-Pallavpurm, Meerut |
| 40 | ST/PCC Pole 11 mtr long |
| 41 | PCC Pole 8.5 mtr long |
| 42 | ACSR Weasal Conductor |
| 43 | 11 KV Pin Insulator with nut and bolt |
| 44 | 11 KV Disc Insulator with nut and bolt |
| 45 | LT AB Cable 3x95 sq.mm |
| 46 | 250 KVA T/F 11/0.4V |
| 47 | 100 KVA T/F 11/0.4V |
| 48 | 11 KV Fuse set |
| 49 | Stay set |
| 50 | Top Channel |
| 51 | Dropper Channel |
| 52 | T-off channel |
| 53 | MS Angle 65x65x6 mm |
| 54 | Earthing rod |
| 55 | Errection ST/PCC Pole 11 mtr long/PCC pole 8.5 mtr long after digging a pit of size 1.6 mtr deep in all type of Soil including grouting ratio (1:4:8) of the pole with proper ramming after completion of work. (as per UPPCL Respo). |
| 56 | Errection of Double PCC Pole 11 mtr long after digging a pit of size 1.20x0.60x1.6 mtr in all type of Soil for each pole including grouting ratio (1:4:8) of the pole with proper ramming after completion of work. (as per UPPCL Respo). |
| 57 | Laying, lifting of LT AB Cable 3x95. (As Per Direction of Supervising Engineer). |
| 58 | Laying of ACSR Weasal Conductor for jumpering. (As Per Direction of Supervising Engineer). |
| 59 | Fixing of Stay rod complete as per norms.(As Per Direction of Supervising Engineer). |
| 60 | Fixing of MS Earthing of each 11 KV line and pole after drive of electrodes if size 20mm x 250 mm and connection the earthing point with GI wire. (As Per Direction of Supervising Engineer). |
| 61 | Providing and Fixing of MS Nut and Bolts. (as per UPPCL Respo). |
| 62 | Providing and Fixing Clamp with nut and bolt (as per UPPCL Respo). |
| 63 | Providing and Fixing 2\" dia GI Pipe upto 80 feet Water level earthing 250 KVA T/F (Neutral and Body) (as per UPPCL Respo). |
| 64 | Making of New 250 KVA T/F Plinth of size 6\"x6\"x3\" (feet) (as per UPPCL Respo). |
| 65 | New Wiremesh Fencing of 250 KVA T/F. (as per UPPCL Respo). |
| 66 | Fixing of Dropper Channel. (As Per Direction of Supervising Engineer). |
| 67 | Fixing of 11 KV Fuse Set. (As Per Direction of Supervising Engineer). |
| 68 | Fixing of Top channel. (As Per Direction of Supervising Engineer). |
| 69 | Fixing of T-off channel. (As Per Direction of Supervising Engineer). |
| 70 | Providing and Fixing of Piercing Clamp. (as per UPPCL Respo). |
| 71 | Providing and Fixing of Suspension Clamp. (as per UPPCL Respo). |
| 72 | Providing and Fixing of Dead and Clamp(as per UPPCL Respo). |
| 73 | Providing and fixing of Stone Pad (as per UPPCL Respo). |
| 74 | Providing and fixing of Tailless Unit (as per UPPCL Respo). |
| 75 | Providing and fixing of Danger Board (as per UPPCL Respo). |
| 76 | Providing and fixing of Copper L-piece 50x225x10mm (LS) (as per UPPCL Respo). |
| 77 | Providing and fixing of Copper L-piece 62x225x12mm (LS) (as per UPPCL Respo). |
| 78 | Providing Rex Oxide Paint (As Per Direction of Supervising Engineer). |
| 79 | Providing Aluminium Paint (As Per Direction of Supervising Engineer). |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender