}

Tender For Special Repairs To Single Living Accn Bldg No Ds 28 Of No 02 Trg Bn And Addn/Altn Of Existing Sewage Line Of Bldg No Ds 25 To Ds 30 At 2 Trg Bn Aoc Centre Under Age B/R (S) No Ii Of Ge (S) Secunderabad, secunderabad-Telangana

Military Engineer Services has published Tender For Special Repairs To Single Living Accn Bldg No Ds 28 Of No 02 Trg Bn And Addn/Altn Of Existing Sewage Line Of Bldg No Ds 25 To Ds 30 At 2 Trg Bn Aoc Centre Under Age B/R (S) No Ii Of Ge (S) Secunderabad. Submission Date for this Tender is 17-09-2025. Building Work Tenders in secunderabad Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

50916612
Tender For Special Repairs To Single Living Accn Bldg No Ds 28 Of No 02 Trg Bn And Addn/Altn Of Existing Sewage Line Of Bldg No Ds 25 To Ds 30 At 2 Trg Bn Aoc Centre Under Age B/R (S) No Ii Of Ge (S) Secunderabad
Tender
Indian
Telangana
Secunderabad
17-09-2025

Tender Details

Tender For special Repairs To Single Living Accn Bldg No Ds 28 Of No 02 Trg Bn And Addn/Altn Of Existing Sewage Line Of Bldg No Ds 25 To Ds 30 At 2 Trg Bn Aoc Centre Under Age B/R (S) No Ii Of Ge (S) Secunderabad-- 1 Dismanting single layer mangalore pattern or similar tiles in roofing including removal of battens complete all as specified and directed. 2 S&F Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings including taking down old one complete all as specified and directed. 3 S&F prepainted galvalume aluminium zink coating GI based corrugated steel sheeting 0.5mm thick of any colour having tensile stength of 550 MPAasin roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed. 4 S&F prepainted galvalume aluminium zink coating GI based plain steel sheeting 0.5mm thick of any colour haing tensile strenghth of 550 MPA as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed. 5 Dismantlingframed wooden purlin/Rafterwork of any descriptionsectional area n exc 40 Sqcm not other wise provided for complete all as specified and directed. 6 Dismantling wrought iron or mild steel work of any description not otherwise provided etc complete all as specified and directed. 7 S&F roof trusses (framed) trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat section) including distance pieces cleats etc confirming to grade Fe-410 W E250 quality A complete all as specified and directed. 8 M&Lfor providing cement concrete type B-1, 1:2:4 (using 20mm graded crushed stone aggregate) as in roof curves or muds, stops, rounded or chamfered on edges complete all as specified and as directed. 9 Demolition of cement concrete in roofincluding existing roof treatement(other than ground floor) and removing debris to a distance of n.exc 100m away from the bldg complete all as specified and directed. 10 M&L for25 mm average thick PCC (1:2:4) Type B0 by using12.50 mm graded crushed stone aggregate as in roofwhere required over slabsand finishing the exposed surfaces faireven without using extra cement complete all as specified and directed. 11 M&L for removal of old treatment of any description and removing the debris roughening the surfaces of old concrete roof surfaces by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed. 12 M&Lfor 10mm thick rendering in CM 1:4 using water proofing compound @ 3% oftotal weight of cement or as per manufacturers instructionover concrete surfacescomplete all as specified and directed. ( Note : WPC measured and paid separately) 13 M&L for priming the plastered roof surfaces with bitumenous primer @ 0.30 Kg per sqm and applying APP based polymeric membrane minimum weighing 3 Kg per Sqm and minimum 3mm thick reinforced with polyster non wove fabric (Wt not less than 150 gms/per Sqm) and on primed surface by forced applicationover apply bitumen base aluminium paint@ 0.20 Kg/Sqm complete all as specified and directed. 14 Supply only water proofing compound complete all as specified and directed. 15 M&Lfor Preparatioin of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat primer complete all as specified and directed. 16 Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etcall as specified and as directed. 17 M&L for brick work with sub class ‘B’ bricks (red bricks) straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed. 18 Taking down plastering on brick walls etc including racking out joints, hacking for key, scrabing down with water etc complete all as specified and directed. 19 M&L for 15 mm thick (inner 10mm layer 1:6 and outer 5mm layer 1:4) rendering in Cement Mortar on fair faces of Brick works or Concrete surfaces and finishing even and fair without using extra cement and using water proofing compound for outer 5mm layer @ 3% of weight of cement use in 5mm thick outer surfaces or as per manufacturers instruction including scaffolding if necessary complete all as specified and directed. Note : Patch work upto height of 10.00m incl necessary scaffolding. (WPC will be measured and paid separately) 20 M&L for 15 mm thick rendering in Cement Mortar 1:6 on fair faces of Brick works or Concrete surfaces and finishing even and fair without using extra cement complete all as specified and directed. 21 M&L for 10 mm thick rendering in Cement Mortar 1:3 on fair faces of Brick works or Concrete surfaces in ceilings and finishing even and fair without using extra cement incl necessary scaffolding complete all as specified and directed. Note : Roof projection/sun shade portion upto ht 7.50m incl necessary scaffolding. 22 M&L for preparation of new plastered surfaces of wall and applying two coats of exterior emultion weather proof paint over a coat of cement primer and a coat of exterior wall care putty complete all as specified and directed.Note : weather proof paintwill be done by Roller only. 23 M&L for preparation of new plastered surfaces of wall and applying two coats of Oil bound distemper over a coat of cement primer complete all as specified and directed. 24 M&L for preparation of new plastered surfaces of ceiling and applying two coats of Oil bound distemper over a coat of cement primer complete all as specified and directed. 25 M&L for Complete removal of existing treatment on ceilings and applying two coats of oil bound distemper over a coat of cementprimer complete all as specified and directed. 26 M&L forComplete removal of existing treatment on walls and applying two coats of oil bound distemper over a coat of cementprimer complete all as specified and directed. 27 M&L for complete removal of existing treatment and preparation of surfaces of walland applying two coats of exterior emultion weather proof paint over a coat of cement primer and a coat external wall care putty complete all as specified and as directed. Note : weather proof paintwill be done by Roller only, after complete removal of old loose flakes 28 Dismantling of wall and ceiling boards (fibre pulp insulation etc) or insulation boards / slabs /blankets any thickness, including cover fillets complete all as specified and directed. 29 S&F False ceiling with anodised aluminium snap grid frame work for false ceiling with size of grid 605 x 605mm with aluminium main tee, cross tee size 25x25x1.6 mmand aluminium wall angle size 25x25x1.8 mmfixed to wall hanging from soffitstrussesbracking using adjustable supportinghanger compressing of GI wire 4mm thick with locking clip including Providing and fixing Non asbestos designer E-Board 4mm thick in ceiling fixed to snap gridas per manufacturers instructions complete all as specified and directed. 30 Taking down chowkat with frame (without taking off shutter from the frame) n exc 1.50 Sqm each complete all as specified & directed. 31 Taking down chowkat with frame (without taking off shutter from the frame) exc 1.50 Sqm n. exc 4 Sqm each complete all as specified & directed. 32 Cutting holes in brickwall builtin cement mortar depth of embedded portion of holdfast exc halfbrick but not exc one brick and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed. 33 S&F pressed steel door frame 125x60 mm for doors with one or more rebates including necessary fixing lugs hinges lock strike plates comlete as specified and directedNote:- PCC filling of holloow section will bemeasured and paid seprately under relevant item. 34 M&L for PCC (1:3:6) type C0 using 12.5mm graded crushedstone aggregate as in lintels blocks, copings, etc for filling of back side MS chowkat etc complete all as specified and directed. 35 S&F 35mm thick factory made plain framed paneled shutter of 2nd class HW (any Number of panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm th venered particle board with veneering on both face kiln seasoned & chemically treated complete all as specified & directed. 36 S&F 35mm thick 2nd class hard wood glazed skeleton door shutters open rebated and prepared to receive glass, gauze, etc (without sah bars) and divided into square with plain, rounded, chamfered, mitred complete all as specified & directed. 37 S&FWindows/Ventilators fabricated from roll framed sections made of galvanized steel colour coated/ powder coated (Base steel as per IS 513 “D” quality galvanized as per IS 277 with zinc of 120 gms/Sqr. Mtr.) with total coated thickness of 0.58mm.Paint Specifications:Coated sections should be with Primer coat of Epoxy Primer of 5-7 microns thick, finish painted with Polyester paint of 12-16 microns thick or Powder Coated with pure Polyester up to 50-60 microns thick.Dimensions of Sections:Sections for Frame should be of 72mm x 55mm, Section for Mullion should be of 72mm x 50mm, Section for Shutter Frame should be of 47mm x 20mm, Section for Fixed Glass Bead should be of 12mm x 12mm, and Section for Fly Mesh should be of 40mm x 20mm.Fixing Details: Section for Frame Glazed Shutters and Mesh Shutters should be cut to length and miter joined with Polypropylene Corner Brackets, Mullion Section should be joined with Frame/Mullion using Mullion Cap Ethyl Propylene Damien Monomer (EPDM) Gasket should be used all around glass in shutter and Fixed Glass. Spoon Section should be used around Fly mesh to fix Mesh in Mesh Shutter.Accessories:Each Glazed Shutter and Mesh shutter should be provided with SS Pivot Hinges – 1 set, Seccolor Handle & Seccolor Stay.Window Frame should be fixed to brick/ concrete masonry by using Nylon self expanding caps and driving MS electroplated 80mm long screws into the caps through frameGlass: Glass shutter & Fixed Glass portions should be provided with a glass of 4MM Plain Float Glass.Mesh:Mesh Shutter should be provided with a Stainless SteelFly mesh of 304 grades. Grill:Windows should be provided with Grill made of 10mm sq. MS Bars welded to at 150mm center-to-center, 5mm x 10mm MS flat. Total grill unit should be powder coated and fixed to window frame with screws.Note: All existing wooden/steel windows & ventilators inclunded tacking down. Make NCL/Elixir 38 S&F Aluminium handle 150mm fabricated type complete all as specified & directed. 39 S&FAluminium anodised barrel tower bolts 200mmof extrded section complete all as specified & directed. 40 S&F 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections complete all as specified & directed. 41 S&F 300 mm long helical door springs including roller plate complete all as specified & directed. 42 S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and avg width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed. 43 M&L for preparation of new wooden surfaces and applying two coats of synthetic enamel paint over one coat of pink primer over 10cm width or girth complete all as specified. 44 Demolition of cement concrete(unreinforced) in ground floors and pavingnexc 15 cm thickness (below and above ground level) complete all as specified & directed. 45 M&L for 75 mm thick PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in plinth protection finished even and smooth without using extra cement complete all as specified & directed. 46 S&F 25mm Stainless steel curtain rods incl required nos ofbrackets complete all as specified & directed. 47 Demolition of stone slabs of any description or thickness in floors, aprons, etc laid, bedded and pointed in any mortar complete all as specified & directed. 48 M&L for cement concrete 75mm thick type D-2, 1:4:8 (using 40mm graded crushed stone agg) as in sub base complete all as specified & directed. 49 M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate)as in sub base flooring complete all as specifiead and as directed. 50 S&F Non skid ceramic coloured tiles 7-8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm in floors surface set and jointed in neat cement slurry and pointed with whiteor colour cement to matchover and including 15mm thick screed bed in cement mortar 1:6 complete all as specified & directed. 51 S&F Non skid ceramic coloured tiles 7-8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm in skirting/dado surface set and jointed in neat cement slurry and pointed with whiteor colour cement to matchover and including 10mm thick rendering in cement mortar 1:4 complete all as specified & directed. 52 S&F Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab forwindow cills, stair steps including rounding of edges, rubbing and polishing andincluding 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed. 53 S&F chequered cement concrete tiles with grey cement and pigments of size 300cmx300cmx20-25mm thick set, jointed and pointed in neat cement slurry over and including 15mm thick CM 1:6 screed bed in flooring complete all as specified & directed. 54 Taking down AC/PVC pipes of any description any pattern incl all fittings heads, shoes bends etc complete all as specified & directed. 55 S&F PVC (SWR) pipes of 110mm dia single socketed in any length with rubber ring joints fixed to walls or in floors including clamps complete all as specified & directed. 56 S&F Vertical looking mirror of size 48cm x 120cm to fixed in verandah of barracks including necessary bolts and fittings complete all as specified & directed. 57 S&F 4mm Plain mild steel wire, galvanised class 3, in detached work such as for mosquito nets and fixing to straining bolts, hook eyes, etc complete all as specified & directed. 58 S&F Bulletin/Pin-in/Notice board (Green, Maroon or Blue) of size 120cm x 90cm (4x3) to be fixed in verandah of barracks including necessary bolts and fittings complete all as specified & directed. 59 Demolition of reinforced cement concretein Roof slab,floors(otherthan ground floors), beams, staircases, landing, chajjas /sunken portion of WC/Bath of any thicknesscomplete all as specified and as directed.NOTE: Necessary arrangement to be made such as formwork/wirenet/Cushion of thickness 300mm before demolition of existing roof slab to avoid damage of floor of 1st floor ( Roof of ground floor). Rate deemed to be included in this rate. No extra payment shall be made separately for this arrangement. 60 Removal of damaged concrete along with loose damaged and cracked concrete/cover concrete at all specified locations up to beyond the corroded steel reinforcement to a depth of 10 mm minimum behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chipper including high pressure water jetting to chipped concretand reinforcement and removal and disposal of debris within owners premises including all plant and machineries. Hard concrete shall not be removed. However if the rebar is corroded, concrete around it shall be removed. Depth of chipping may very from 50 mm to150 mm complete with labor, machinery, tools etc. all a directed by Engg.in charge. The edges of repair locations shall be saw cut to a depth of at least 10 mm to avoid feather edgeing and provide a square edge. Removal of dust, loose particles, marine growth etc. from concrete surface manually by wire brush, mechanically or any other means to obtain a sound surface over areas other than above complete all as specified & directed. 61 Cleaning as directed & specified all rust/ scales/corrosion from reinforcement bars using rust remover agent like Reebaklens RR of Fosroc or equivalent having Specific Gravity 1.16 - 1.22. The material to be applied to the rusted metal using brush and make leaving to dry for 30 mins & washing surface with fresh water as required to exposed reinforcement bars complete all as specified & directed. 62 S&Finhibition coats/system to exposed reinforcement bars after drying & also new bars after cleaning & removing scales and rust completely as specified. Two component inhibitor Nitozinc Primer or equivalent having specific gravity of 1.75, Adhesive bond strength > 1.5 N/mm2, Solid content- 60 %, 40 microns DFT as approved by engineer shall be used as per manufacturers specification in two coats including all labors, tools and tackles, necessary surface preparation and necessary protection after and during work complete all as specified and directed. 63 S&Fbond coat on the prepared surface to receive polymer modified mortar/polymer modified micro concrete, with two component epoxy based bonding coat Nitobond EP Std of Fosroc make or equivalent, having specific gravity 1.15 to 1.2 gm/cc, Compressive strength(BS 6319 Pt.2)- 50 Mpa at 7 days, Flexural strength strength(BS 6319 Pt.3)- 35 Mpa at 7 days, Tensile strength (BS 6319 Pt.7)- 20 Mpa at 7 days, Shear Strength (BS 6319 Pt.4)- 10 Mpa at 7 days, having an over lay time of 6 hrs. and 300 C. Laying of reinstatement polymer modified mortar or micro concrete shall be completed within the overlay time of bonding coat. The bond coat act as a bonding coat between old and new concrete. Item rate is inclusive of materials all Labour, tools and tackles, scaffolding and transportation etc complete all as specified and directed. 64 Providing and applying polymer modified micro-concrete like Renderoc RG of Fosroc make or equivalent having compressive strength (BS 4551-80)-50 Mpa at 28 Days, Tensile strength- 2 Mpa @ 28 Days, Flexural Strength(BS 4551-80)-5 Mpa at 28 Days, Young’s modulus-25 kN/mm2, Expansion characteristics (ASTM C827 - 1987)Unrestrained expansion 1 to 4 %,Pressure to restrain Plastic Expansion-Approx. 0.004 N/mm2,Thermal Conductivity – 1.5 W/m C. Pouring the same into the formwork using suitable arrangement or if required using pumping device for uniform flow of micro concrete. The side shuttering can be removed after 3 days and the bottom shuttering after 7 days ensuring proper bond between the micro concrete and existing concrete substrate. Item rate is inclusive of materials all Labour, tools and tackles, scaffolding and transportation etc. complete all as specified and directed. 65 S&Fpolymer modified single component, alkaline resistant fiber reinforced, thixotropic, cementitious patch repair mortar Renderoc SP 40 of Fosroc make or equivalent that achieves compressive strength (BS 1881 Pt.116) -> 20 Mpa at 1 day & > 45 Mpa at 28 days, Tensile Strength (BS 6319 Pt.7) > 2.5 Mpa at 28 Days, Flexural Strength (BS 6319 Pt.3)>7 Mpa at 28 days, Drying shrinkage to ASTM C 157-93, 28 days < 1000 micro strain. Finishing the same with trowel carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface on the beams, slabs, piles etc where the thickness of application is average 30 mm in patches as per specification after applying bonding coat (bonding coat shall be payable separately). Item rate is inclusive of materials all Labour, tools and tackles, scaffolding and transportation etc. complete all as specified and directed. 66 S&F Acrylic emulsion based curing compound-Concure AB; Solids content : 33 ± 1% as per (ASTM D1644; Drying time : < 4hrs @ 23°C(ASTM C135, M 8.3) complete all as specified and directed. 67 Supply of Polymer admixture for waterproofing and anti carbonation coating Emulsified Acrylic Polymer complete all as specified and directed. 68 Excavation in trenches n.exc. 1.5 m wide and n.exc. 1.5 m in depth for foundation or manholes etc., and area n.exc. 10 Sq.m on plan and getting out in hard/dense soil complete all as specified and directed. 69 Excavation in trenches n.exc. 1.5 m wide and exc. 1.5 m and n. exc. 3.0 m in depth for foundation or manholes etc., and area n.exc. 10 Sq.m on plan and getting out in hard/dense soil complete all as specified and directed. 70 Returning, filling in with approved soil obtained from excavation including spreading levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and directed. 71 Removing the excavated soil to a distanceexc 250.0 m and n.exc 500 .0m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. 72 Demolition and breaking up drain pipes(salt glazed ware,AC or reinforced concrete) set in cement mortar including concrete bedding and haunching complete all as specified and directed for 100mm dia pipe all as specified and directed. 73 Description all as per item no 72 above but 150 mm dia pipe complete all as specified and directed. 74 Description all as per item no 72 above but 200 mm dia pipe complete all as specified and directed. 75 M&L Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2(using 40mm graded crushed stone aggregates) for 100mm dia pipe complete all as specified and directed. 76 Description all as per item no 75 above but 150mm dia complete all as specified and directed. 77 Description all as per item no 75 above but 200 mm dia complete all as specified and directed. 78 S&F SWG drain pipe grade A of100 mm internal dia laid in trenches and jointedin cement mortar 1:1 complete all as specified and directed. 79 Description all as per item no 78 above but 150mm dia complete all as specified and directed. 80 Description all as per item no 78 above but 200 mm dia complete all as specified and directed. 81 Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting ou existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 100 mm dia SWG pipe complete all as specified and directed. 82 Description all as per item no 81 above but 150mm dia complete all as specified and directed. 83 Description all as per item no 81 above but 200 mm dia complete all as specified and directed. 84 M&L for brick work with fly Ashbricks built in CM 1:4 straight or curved exceeding 6m mean radius complete all as specified and directed. 85 Demolition of reinforced cement concrete of any description and in any position, not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed. 86 M&L for Precast reinforced cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate ) for manhole cover septic tank covers slabs etc including necessary form work and set in CM (1:4) complete all as specified and directed. Note:- Reinforcement will be measured and paid seperately under relevant item. 87 S&F TMT bars 10 mmdia and over for reinforcement etc, cut to length, bent to shape required including cranking, bending sprially for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified & directed. 88 Taking down cement plaster on brick or stone masonry wall etc incl racking out joints haking for key, scrubbing down with water etc as in internal and external surfaces of man holes, septic tank, filter bed etc incl removing of debries complete all as specified and directed. 89 M&L for rendering 15mm thick in CM 1:4 using WPC @ 3% of total cement used or as per manufacturers instruction on fair faces of brick/concrete finished even and fair without using extra cement complete all as specified and as directed. Note:-WPC will be meausred and paid separately under relevant item. 90 S&F in repairs PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls or in trenches bore of the pipe 110 mm complete all as specified and directed. 91 S&F in repairs PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls or in trenches bore of the pipe 75 mm complete all as specified and directed. 92 S&F PVC(SWR)in repairs bends 110 mm dia complete all as specified and directed. 93 S&F PVC(SWR)in repairs bends 75 mm dia complete all as specified and directed. 94 S&F PVC(SWR) in repairs junction double,(double T) equal or unequal. 110 mm dia with access door complete all as specified and directed. 95 S&F PVC (SWR) in repairs vent cowl 110 mm dia complete all as specified and directed. 96 S&F 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement in repair complete all as specified and directed. 97 S&F in rpairs for PVC (SWR) gully trap of I25/110 mm dia set and jointing wilh solvent cement complete all as specified and directed. 98 M & L for taking down copper/aluminium point wiring (light, fan, socket, power, security lights or bulkhead) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed. 99 Taking down existing unserviceable Distribution boards / AC board with MCBs any size and any type complete all as specified and as directed. 100 S&F Point wiring complete with two runs of 1.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLSH cable of 1100V grade drawn through and including new non metallic rigid PVC concealed conduit medium grade , ISI marked , 20 mm bore with conduit accessories forwiringconcealed in wall, including provision of fabricated branded pressed steel terminalboxconcealedof suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards/sockets/regulators of any size modules for housing modular switches, sockets, fan regulators etc and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. complete all as specified and as directed for one light point controlled by one switch.Note(1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.(2) The cost ofcutting of chases of required width and depth for concealled conduit incl plastering, making good to disturbed surface, painting two coats to match the existing wall colour is deemed to be included in the quoted rate by the contractor. 101 S&F Point wiring complete with two runs of 1.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLSH cable of 1100V grade drawn through and including new non metallic rigid PVC concealed conduit medium grade , ISI marked , 20 mm bore with conduit accessories forwiringconcealed in wall, including provision of fabricated branded pressed steel terminalboxconcealedof suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards/sockets/regulators of any size modules for housing modular switches, sockets, fan regulators etc and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. complete all as specified and as directed for one light point controlled by one switch.Note(1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.(2) The cost ofcutting of chases of required width and depth for concealled conduit incl plastering, making good to disturbed surface, painting two coats to match the existing wall colour is deemed to be included in the quoted rate by the contractor. 102 All as per item no 101 but One three pin switch socket 6 Amps outlet on same board complete all as specified and directed. 103 All as per item no 101but One light point controlled by two nos of two way switches complete all as specified and directed. 104 M & L for Point wiring complete with two runs of 2.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLSH cable of 1100V grade drawn through and including new non metallic rigid PVC concealed conduit medium grade , ISI marked , 20 mm bore with conduit accessories forwiringconcealed in wall, including provision of fabricated branded pressed steel terminalboxconcealedof suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards of any size modules for housing modular switches, sockets,etc and provn of 2.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. complete all as specified and as directed for one 15 Amps socket outpoint independent boardNote(1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.(2) The cost ofcutting of chases of required width and depth for concealled conduit incl plastering, making good to disturbed surface, painting two coats to match the existing wall colour is deemed to be included in the quoted rate by the contractor. 105 M & L for Point wiring complete with two runs of 4 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLSH cable of 1100V grade drawn through and including new non metallic rigid PVC concealed conduit medium grade , ISI marked , 20 mm bore with conduit accessories forwiringconcealed in wall, including provision of fabricated branded pressed steel terminalboxconcealedof suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards of any size modules for housing modular switches, sockets etc and provn of 4 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. complete all as specified and as directed for one 15 Amps socket outpoint independent boardNote(1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.(2) The cost ofcutting of chases of required width and depth for concealled conduit incl plastering, making good to disturbed surface, painting two coats to match the existing wall colour is deemed to be included in the quoted rate by the contractor. 106 S&F in repair Modular switch 1 way 6A , 1-module complete all as specified and directed. 107 S&F in repair Modular switch 1 way 16A with indicator, 1-module complete all as specified and directed. 108 S&F in repair Modular socket, shuttered type, 6A - 3 pin 2 -module complete all as specified and directed. 109 S&F in repair Modular socket, shuttered type, 6/16A -combined 2-modulecomplete all as specified and directed. 110 S&F in repair Modular switch 2 way 6A,1 module complete all as specified and directed. 111 S & F in repair 3 pin, 6 A, 250 V ceiling rose having terminal capacity 3 X 1.5 mm² IP 20 protection complete all as specified and directed. 112 S&FCeiling fans complete with blades,copper winding, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery not less than 210 CFM with service value more than equal to (≥)6.00, BEE Five star rated with brushless direct current motor (BLDC) white colour complete all as specified and directed. Make:Gold Medal cat part no.SCFS 500748/Bajaj Cat part No:ENERGOS 28/ Crompton Cat part No:ENERGION RIVIRA/Havells Cat part No:PRO 28BLDC/Luker Cat part No:ECO28NEOBLDC Regulator 222cmm 113 S&F Exhaust fan, metal body AC single Phase 230V of size 300 mm sweep,RPM 1200 with, copper winding,blades,rag-bolts, and frame and louvers complete including making suitable size hole in wall for fixing of fan complete all as specified and directed.Make: Havells Cat part No:Ventil air DSB/Gold Medal EFS851012 HAVAC PLUS /Crompton drift air plus300mm/Bajaj-Supreme plus/Luker cat part No:TuuliLME12 114 S&F in replacement 20 W surface / wall mountedLED batten light fitting aluminium extrusion input voltage range 250 V, input frequency 50 Hz, efficacy not less than 120 Lumen/Watt, rated llife 50000 Burning hours including 2 nos PVC Connector blocks electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.Make: Crompton CCS-100-20-65-HSL2-DP-NWH/ PHILIPS BN308CLED20S-6500L120PSUWH / WIPRO LL31-251-XXX-65AL5/Havells ENDURALINEARPROBS20WLED865PCSSIND/Bajaj-BCLAB20WCWLEDXT 115 S&F in replacement LED security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant,efficacy not less than 120 lm/Watts,rated life 50000 burning hours complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with wall mounting bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete suitable for pop/grid false ceiling in all respect complete all as specified and directed.Make:Crompton TRP-409-45-57-SL-GL-NSG / PHILIPS BRP030LED35CWSLRGRPSUV1 / HAVELLS ENDURASUNDOWNSL45WLED765PASYBOPC/WIPRO LR22-501-XXX-57-XX/Bajaj-VISTAP45LWHPOPCSD 116 S&F in replacement of TPN DB 4 way double door horizontal made out of CRCA sheet housing duly powder coated & confirming to IS specification complete all as specified and directed. 117 S&F single pole & neutral, double door, metallic distribution board 8 ways conforming to IEC 61439-3, suitable for flush / surface mounting with provision for DP MCB as incomer and SP MCBs as outgoing, concealed in wallcomplete all as specified and directed. 118 S&F MCB SP 6 to 32 Amps C series complete all as specified and directed. 119 S&F MCB, single pole, 40 Amps, 240 Volts,connecting with copper lugscomplete all as specified and directed. 120 S&F MCB three phase and neutral (TPN), 125 Amps, 415 Volts,connecting with lugs, complete all as specified and directed. 121 S&F MCB single phase and neutral (SPN), 40 Amps, 230 Volts,connecting with lugs, complete all as specified and directed. 122 S&Fin repair Submain concealed wiring with 2 runs of single core 6 sqmm PVC insulated FRLSH multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVCconcealed conduitand conduit accessories of medium grade not not less than 25mm dia including one run of single core 6 sqmm PVC insulatedsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain riwing complete all as specified and as directed.Note:-(1) The wiring shall be done in proper color coding using red,yellow,blue for phases , black for neutral and green for earth(2)The cost ofcutting of chases of required width and depth for conduit incl plastering ,painting two coats to match the existing wall colour is deemed to be included in the rate quoted rate.(3) The three runs of copper wireone run of PVC coduit is shall be measured as one running meter. 123 M&L for Earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.5meters below normal ground level, earth plate connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR-2009 (part I Specifications) connected to earth test point all as specified or indicated including testing on completion, including necessary excavation and earth work in any type of soil and adequate quantity of common salt & charcoal for alternate layer around the earth plate, including PCC (1:2:4) pit and 10mm thick C.I. cover with arrangement of hinge to 40x40x6mm C.I. angle iron frame, including 20mm dia G.I. pipe for watering purpose with the arrangement of funel and wire mess, including GI pipe of 15 dia for earth lead protection incl taking down old one complete all as specified and as directed. 124 M&L for earth continuity conductor 4 Sq.mm dia GI or steel wire complete incl taking down old oneall as specified and as directed.

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
INR 48.72 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail