Procurement Of Different Type/Kind Of Lt Cable For Chpem Dept., Btps. , Procurement Of Different Type/Kind Of Lt Cable Of Chpem Dept., Btps. , Cable,3.5C,50Mm2,1100/1100V, Al # 85Degc Rating Heavy Duty Power Cables With Stranded Aluminiu Additional Data: Cable Xlpe Al 3.5Cx50mm2 1.1 Kv Grade, Armoured Minimum Continuous Length: 500 Mtr., Tolerance In Length: +/-5%, Each Core Coded By Different Colour , Cable, Al,3.5Cx 35 Mm2, Xlpe, Armoured # Cable Lt Power Aluminium Conductor Xlpe Insulated Armoured With Flat Galvanised Steel Strip 1.1Kv Grade 3.5 Core X 35 Sq Mm. Additional Data: Cable Xlpe Al 3.5Cx35mm2, 1.1Kv Grade, Armoured With Flat Galvanised Steel Strip. Minimum Continuous Length: 500 Mtr., Tolerance In Length: +/-5%, Each Core Coded By Different Colour , Cable,3Cx2.5,1.1Kv, Cu, Frls # Additional Data: Cable Xlpe Cu 3Cx2.5 Mm2 1.1Kv Grade, Annealed Plain Stranded Copper Conductor, Frls, Extruded Pvc Inner Sheathed, Gi Round Steel Wire Armouring , Cable,12Cx1.5,1.1 Kv, Cu, Pvc # Additional Data: Cable Pvc 12Cx1.5Mm2, 1.1Kv Grade, Annealed Plain Stranded Copper Conductor, Gi Round Steel Wire Armoring , Cable,4C,16Mm2,1100V, Al, Pvc 4 C,16 Mm2,1100 Volt Grade, Pvc Insulated, Armoured, Pvc Inner And Outer Sheathed Power Cable With Al Conductor (Is: 1554 Part-I) Additional Data: Cable Pvc 4Cx16mm2,1.1 Kv Grade, Aluminium Conductor Armoured With Flat Galvanised Steel Strip. Minimum Continuous Length: 500 Mtr., Tolerance In Length: +/-5%, Each Core Coded By Different Colour , Cable,7C,1.5Mm2,1100V, Cu, Stranded, Pvc # C Pvc-Colour Coded For Of 1100 Volt Grade 70Degc Rating Control Cables With Stranded Additional Data: Cable Pvc 7Cx1.5Mm2, Annealed Plain Stranded Cu Conductor, Gi Round Steel Wire Armouring , Cable Cu 4 C 4Mm2 Multistand Conductor # Additional Data: 4Cx4sqmm Copper Pvc Insulated Armoured Str Frls Control Cable 1.1Kv. Standard. The 1100V Grade Control Cable Shall Be Frls Type St-2 Category C-2 Conforming To Is: 1554(Parti) And Its Amendments. The Armouring Shall Be Galvanized Round Steel Wires. The Outer Sheath Shall Be Frls Type St-2 Category C-2 Conforming To Is: 5831 And Its Latest Amenment. Outer Sheath Shall Be Fire Retardant Low Smoke (Frls) Type, Frls Type St-2 Category C-2 To Is: 1554(Part-I) And Its Amendments. , Cable,5C,1.5Mm2,1100V, Cu, Stranded, Pvc # C Pvc-Colour Coded For Of 1100 Volt Grade 70Degc Rating Control Cables With Stranded Additional Data: Cable Pvc Armoured 5Cx1.5 Mm2 Conductor: Stranded Annealed Tinned Copper As Per Class-2 Of Is: 8130, Insulation Material: Pvc Type-C As Per Is: 5831, Armouring: Galvanised Steel Round Wire/Flat Strip , Cable, Armoured, Frls,1.5 Mm2, 2 Core # For Fire Alarm System, 18 Awg Bare Copper, Fplr, Nec Article 760, Bs5839-1 Approved, Unshielded With Overall Jacket, Low Smoke, Halogen Free Additional Data: 1.Wire Size:1.5 Sqmm 2.Conductor: Copper 3.Flame Retardant: Yes 4.Conductor: Plain Annealed Copper Stranded Circular 5.Standards: As Per Bs 5467: 1997 6.Nominal Od. 11.50 ± 2.0 N.B:1100 Volts Grade, Class 2 Plain Annealed Stranded Circular Copper Conductor, Pvc Insulated Extruded Pvc Type St 2 Inner Sheathed, Single Layer Galvanized Steel Round Wire Armoured, Extruded Frlsh Type St 2 Outer Sheathed Cable In Black Colour As Per Bs-5467:1997, Copper Control Cables. , Gst, If Any