| 1 | Cartage of following material from store center Meerut to Site of work including loading & unloading at both ends maximum distance up to 40 Km. :- (as per direction of Supervising Engineer ). |
| 2 | 250 KVA T/F 11/0.4 KV |
| 3 | 100 KVA T/F |
| 4 | 11 KV Fuse Set |
| 5 | LT PVC Cable Al 1x240 sq.mm |
| 6 | AB Conductor 3x95+1x16+1x70 sq.mm |
| 7 | PCC Pole 8.5 long |
| 8 | PCC Pole 11 mtr long |
| 9 | LT PVC Cable 3.5x70/35 sq mm |
| 10 | Earthing Rod |
| 11 | Stay Set |
| 12 | 11 KV Pin Insulator with Pin |
| 13 | 11 KV Disc Insulator with Fitting |
| 14 | GI Wire 6 SWG |
| 15 | ACSRConductor |
| 16 | Erection of PCC pole 8.5 Mtr long after digging a pit of size 1.6 mtr. Deep in all tyoe of soilincluding back filling of the pole with proper ramming after completion of work. (as per UPPCL Respo). |
| 17 | Erection of Double pole on PCC pole 11 mtr including fabrication and fixing of all accessories after digging a pit of size1.6 mtr deep in all type of Soil for each pole including back filling of the pole with proper ramming after completion of work.(as per UPPCL Respo). |
| 18 | Laying, lifting of LT AB Conductor 3x120+1x16+1x95 sq.mm (as per direction of Supervising Engineer). |
| 19 | Laying, lifting of ACSR Conductor incuding all accessories (as per direction of Supervising Engineer). |
| 20 | Fixing of PVC Cable 3.5x150/70 sq mm (as per direction of Supervising Engineer). |
| 21 | Fixing of LT PVC Cable Al 1x240 sq.mm (as per direction of Supervising Engineer). |
| 22 | Fixing of 11 KV Fuse Set (as per direction of Supervising Engineer). |
| 23 | Construction of New 250 KVA T/F Plinth of size 6\"x6\"x3\" (feet) (as per direction of Supervising Engineer). |
| 24 | Providing and Fixing of Wiremesh Fencing of 250 KVA T/F (as per direction of Supervising Engineer). |
| 25 | Water level earthing of 250 KVA T/F (as per direction of Supervising Engineer). |
| 26 | Mounting of 100 KVA T/F on double pole (as per direction of Supervising Engineer). |
| 27 | Providing and Fixing of Tailless Unit of 250 KVA T/F (as per UPPCL Respo). |
| 28 | Providing and Fixing of Danger board barbed wire including jumper (as per direction of Supervising Engineer). |
| 29 | Providing and Fixing of Copper L-piece 50x225x10mm (LS) (as per direction of Supervising Engineer). |
| 30 | Providing and Fixing of Copper L-piece 62x225x12mm (LS) (as per direction of Supervising Engineer). |
| 31 | Providing and Fixing of Al Lug long barrel off size (LS) (as per direction of Supervising Engineer). |
| 32 | Providing and Fixing of LT fuse box (as per UPPCL Respo). |
| 33 | Fixing of Stay set complete (as per direction of Supervising Engineer). |
| 34 | Fixing of Earthing Set Complete (as per direction of Supervising Engineer). |
| 35 | Providing and Fixing of MS angle 65x65x6 sq.mm (as per UPPCL Respo). |
| 36 | Providing and Fixing ofTop Channel (as per UPPCL Respo). |
| 37 | Providing and Fixing ofDropper channel (as per UPPCL Respo). |
| 38 | Providing and Fixing ofT-off channel (as per UPPCL Respo). |
| 39 | Providing and Fixing of suspenction clamp with J hook (as per UPPCL Respo). |
| 40 | Providing and Fixing of Dead and clamp (as per UPPCL Respo). |
| 41 | Providing and Fixing of Stone Pad (as per direction of Supervising Engineer). |
| 42 | Providing and Fixing of Clamp with nut and bolt (as per direction of Supervising Engineer). |
| 43 | Grouting of Stay (as per direction of Supervising Engineer). |
| 44 | Fixing of GI wire for Earthing Rod (as per direction of Supervising Engineer). |
| 45 | Back Cartage 100 KVA T/F (Old and Used) Site to Store Centre, Meerut (as per direction of Supervising Engineer). |