| 1 | Dismantling of old unserviceable ACSR conductors from existing PCC/RCC/Steel poles complete all as specified and directed. |
| 2 | Dismantling of old unserviceable insulators any type & any size from pole (PCC/RCC/Steel) complete all as specified and directed. |
| 3 | Dismantling of Cross arms of MS channel or angle section etc complete all as specified and directed. |
| 4 | Dismantling stay assembly complete with stay wire complete all as specified and directed. |
| 5 | Disconnecting and taking outoldexistingunserviceable LT/HT under groundcable of any description and in any position fromtrenches/ under floor,roads,paths or from walls / from poles/ from ducts etc complete all as specified and directed. |
| 6 | Dismantling old unserviceable GI earth wire/guarding complete all as specified and directed. |
| 7 | Supply, laying and testing of XLPE insulated armoured heavy duty electric cable with aluminium conductor ,1100 volts grade ,cross section area 10 Sqmm 4 core complete laid in trenches, ducts or fix to pipe, on walls, poles complete all as specified and directed. |
| 8 | Supply, laying and testing of XLPE insulated armoured heavy duty electric cable with aluminium conductor ,1100 volts grade ,cross section area 10 Sqmm 2 core complete laid in trenches, ducts or fix to pipe, on walls, poles and connections to existing source with controlling switch complete all as specified and directed. |
| 9 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m depth for foundation ,laying of cables/pipes/poles etc., and getting out in any type of soil complete all as specified and directed. |
| 10 | Excavation in trenches not exceeding 1.50m wide and exc 1.50m but n.exc 3.0m depth for foundation ,laying of cables/pipes/poles etc., and getting outin any type of soil complete all as specified and directed. |
| 11 | Returning filling in including spreading levelling watering and well ramming in layers not exceeding of 25 cm thickin any type of soil complete all as specified and directed. |
| 12 | Removal of surplus soil as obtained from excavation to a distance not exc. 50 Mtr and depositing where directed at a level not exc. 1.5 Mtr above the starting point complete all as specified and directed. |
| 13 | Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable including spreading levelling watering and consolidation complete all as specified and directed.Note:-Punned thickness shall be measured for payment purpose. |
| 14 | Supplying andlayingun-reinforced precast concretecablecover, Class LV, Type I,flat,size 250 mm x 150mm x 40mm \" laid in trenches flat complete all as specified and directed. |
| 15 | Supply and fixing light grade GI tubing 40 mm dia with all fitting laid in trenches complete, including taking out old unserviceable pipe complete all as specified and directed. |
| 16 | Supply and fixing light grade GI tubing 50 mm dia with all fitting laid in trenches complete, including taking out old unserviceable pipe complete all as specified and directed. |
| 17 | Supply and Fixing street light Engineering plastic one piece moulding junctionbox with locking arrangmentmade out ofHDPE and FI clamp 25 x 3mm complete ofdimensions in CM+/-10%(34x28x13) with and including MCB SP 6 Amp 240 Volts complete with 04 Nos aluminium busbar or terminal four nos (3P-RYB and N) of rating 63 amps for single phaseand neutral on porcelain based insulators and fixing clamps to pole for street lights complete, including taking out old unserviceable junction box complete all as specified and directed. |
| 18 | Dismantling old unserviceable concrete pole 9 metre long with foundation and Supply ,erecting and fixing the true vertical position,steel tubular swaged pole(410 SP-31),09 mtr long, complete with cast iron base plate,pole cap/final taper plug ,bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire lenght of pole,including two coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be painted with one coat of red oxide primer and two coats of aluminium paint complete all as specified and directed.Note: (i) (Numbering of the poles shall be done with synthetic enameled paint and letter of shape & size as directed by engineer-in-charge. (ii) Cost of painting and numbering of pole shall be deemed to included in unit rate.(iii) Excavation, Earth work and PCC foundation will be measured and paid separately. |
| 19 | S&F GIbracket made out of GI pipe light grade of size 40/32 mm 1.2 m long cut to length bend to the required shape and 02 Nos mounting flat iron clamps size 40mm x 6mm, 04 Nos hexagonal bolts 10mm dia 100mm long with nuts and washers complete, including taking out old unserviceable brackets complete all as specified and directed. |
| 20 | Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, including taking out old unserviceable light fitting complete all as specified and directed. |
| 21 | Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, including taking out old unserviceable light fitting complete all as specified and directed. |
| 22 | Supply and fixing LED building security light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, including taking out old unserviceable light fitting complete all as specified and directed. |
| 23 | M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) in foundation of PCC poles/struts/stay assembly etc, including necessary form work complete all as specified and directed. |
| 24 | M&L for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) in foundation of stay assembly/pole etc including necessary form work complete all as specified and directed. |
| 25 | M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) for coping around poles, including necessary form work finishing even and smooth without using extra cement complete all as specified and directed. |
| 26 | Supply and laying or fixing or passing through pipe, 1100 volts grade weather proof PVC insulated aluminium conductor cable 1.5 Sqmm 3 core in service connections, including taking out old conductor cable complete all as specified and directed. |
| 27 | M & L for boring of holes by trenchesless technology using machine bore of 80mm dia (min) for inserting GI pipe 50mm dia bore at road crossing including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m for road/path crossing complete all as specified and directed.Note:- PCC work/GI pipe shall be measured and paid separately in respective item of this schedule. |
| 28 | Supply, fixing and testing cone LED Bollard light IP 65, 8 Watt of model Havells Cat Part No CONEBLS8WLED830PSYMTOPC or equivalent make as given in Appx \"C\" complete, including taking out old unserviceable light fitting complete all as specified and directed. |
| 29 | Supply and fixing 40 watt,240 volts,5700 ANSI,decorative LED post top Lantern luminaire with diffuser and painted spun aluminium deflecter complete mounted on cast aluminium capsule type complete fix on suitable dia GI pipe withscrew/nut complete, including taking out old unserviceable light fitting complete all as specified and directed. |
| 30 | Supply, fixing and testing Street light automatic Nature switch of capacity 5 KW single phase complete withusing infrared sensor based NATURE SWITCH for automatic switching of street lights.Nature Switch operation should be based on Nautral Light Lux* level.Required illuminance level for switching ON is ≤ 30 Lux and for swiching OFF ≥10 Lux. The sensor should also have part night operation facility of min.4 hrs to max 12 hrs. The sensor along with suitable power contactor(s) and incoming-outgoing MCBs should be enclosed in a pole/wall/panel mountable Rust proof, Electric Shock Proof, Termite proof and FR grade thermoplastic polycarbonate Enclosure ( with Hinged LID) conforming to IP66 protection class 2.The circuit should also have provision for Manual Operation(i.e Sensor By-Pass option), including taking out old Street light timer complete all as specified and directed. Make - Kakatiya Energy system Model SWADEEP-66-5KW 1P or equivalent as given in Appx \"C\". |
| 31 | Supply and installation, connecting, commissioning and testing of LT panel with onload changeover switch 320 Amp 4 Pole with CPRI approvedmainfactory fabricatedLT distribution panel board, outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 600 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel, Make of CT - AE, CT Ratio:400/5 Amp(a)Aluminium bus barcap 400 Amp - 04 Nos(b) MCCB 4 pole with thermal magnetic release adjustable type with breaking capacity36 KA 320 Amp (incoming) -01 Nos(c)MCCB 4 pole with thermal magnetic release adjustable type with breaking capacity 25 KA,125 Amp (Outgoing)- 03 Nos(d)MCCB 4 pole with thermal magnetic release adjustable type with breaking capacity 25 KA,100 Amp (Outgoing)- 03 Nos(e) MCB SPN 63 Amp 10KA-4 Nos(f) MCB SPN 32 Amp 10KA-2 Nos(d)Digital Voltmeter-96 x 96 mm flushsecure Panel mounting type 0-500V with selector switch- 01 No,Make-L & Te) Digital Amp meter96 mm X 96 mm flush secure Panel mounting type 0-400 Amps with selector switchwith CT - 01 No 400/5 A ,Make-L & T(f) RYB neonindicatinglamp setof three- 01 Make-L & TNotes:(i) Rates are deemed to be inclusive of PCC platform of suitable size and 45cm height and 4 Nos legs of 50mmx50mmx6mm and 60 cm in height for fixing the panel. (ii) Make of MCCB & Make of Panel :-as per appx \"C\" & approved by GE.(iii) Danger notice plate (02 Nos) in Hindi and English ofsize +/- 10% of 20cmx 15cm shall be fixed on the panel . |
| 32 | Taking out old earthing including connected accessories and M&L for earthingcomplete with using galvanized mild steel earth plate (electrode) 600 mmx 600 mmx 6 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plateusing 32X6 mmGI earth strip as earth lead moulded and riveted to earthplate at one end and connected to main equipment at switch/control board at another end, GI earth leadincased in and including 50 mm dia GI ‘light grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of the earth plate,GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mmthick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone agg)duly reinforced with mild steel round bars 6 mm dia @ 150 mmc/c both ways with 10 mm dia mild steel bars as in lifting handles with and including necessary excavation & earth work includinglaying the GI pipe concealed in floor /wall all as per plate No. 3 of SSR Part I complete all as specified and directed and testing on completion.Note : If the desired earth resistance is not found earthing shall be re-done by the Contractor at no extra cost to govt. |
| 33 | Taking out old earthing including connected accessories and M&L for earthingcomplete with using galvanized mild steel earth plate (electrode) 600 mmx 600 mmx 6 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plateusing 25X4 mmGI earth strip as earth lead moulded and riveted to earthplate at one end and connected to main equipment at switch/control board at another end, GI earth leadincased in and including 50 mm dia GI ‘light grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of the earth plate,GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mmthick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone agg)duly reinforced with mild steel round bars 6 mm dia @ 150 mmc/c both ways with 10 mm dia mild steel bars as in lifting handles with and including necessary excavation & earth work includinglaying the GI pipe concealed in floor /wall all as per plate No. 3 of SSR Part I complete all as specified and directed and testing on completion.Note : If the desired earth resistance is not found earthing shall be re-done by the Contractor at no extra cost to govt. |
| 34 | Supply, installation and testing in renewal Electromagnetic Flow Meter with transmitter (Remote Mounting) with following specification :-(a) Electromagnetic Flow meter full bore,flanged, diameter DN 350, 14 inches with flange pressure rating ANSI B16.5, class 150, flange material Carbon steel flanges ASTM A 105, corroison resistance coating of category C4, Liner material PTFE, Electrode Material Stainless steel AISI 316 Ti/1.4571, Transmitter MAG 5000, IP 67/NEMA 4 X/6, Polyamid enclosure, with display, 115-230 V AC, 50/60 Hz, meter cable glands, polyamid terminal box or MAG 600i integral mount complete all as specified and directed by Engr-in-charge.(b) Flow Transmitter 115-230 Volts, 4-20 mA output MAG 5000 0.4% +/- 1 mm/s, IP67 Protection,fibre glass reinforced polyamide enclosure material with display and remote mounting complete all as specified and directed by Engr-in-charge |
| 35 | Supply, installation and testingin renewal Electromagnetic Flow Meter with transmitter (Remote Mounting) with following specification :-(a) Electromagnetic Flow meter full bore,flanged, diameter DN 500, 20 inches with flange pressure rating EN1092-1 PN-16, flange material Carbon steel flanges ASTM A 105, corroison resistance coating of category C4, Liner material PTFE, Electrode Material Stainless steel AISI 316 Ti/1.4571, Transmitter MAG 5000, IP 67/NEMA 4 X/6, Polyamid enclosure, with display, 115-230 V AC, 50/60 Hz, meter cable glands, polyamid terminal box or MAG 600i integral mount complete all as specified and directed by Engr-in-charge.(b) Flow Transmitter 115-230 Volts, 4-20 mA output MAG 5000 0.4% +/- 1 mm/s, IP67 Protection,fibre glass reinforced polyamide enclosure material with display and remote mounting complete all as specified and directed by Engr-in-charge |
| 36 | Supply and fixingin renewal LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 37 | Supply and fixingin renewal New generation energy saving enviroment friendly long life aesthetically designed aluminium landscape IP 65 luminaire for diffused lighting mount sturdy LED Bollardwith high power LED as light source maximum illumination aspectin surrounding garden light 08 Watt, inbuilt driver, IP 65, 230 Volt, complete connection with PVC insulated multi stranded copper flexiblewire twin core of suitable size from nearest source complete all as specified and directed. |
| 38 | M&Lfor renewal of construction of brick masonry valve pit chamber of size 1200x1200x1000 mm, with andincluding necessary earth work, PCC, copping, plastering on internal surface of valve pit,Framed work for the valve pit chamber cover made of MS sheet angle equal angle 40x40x5 mm and MS sheet 3 mm thick confirming to Fe410-o and Fe 310-o including welding cutting hinges locking arrangement complete and two coat of synthetic enamel paints over a coat of red oxide primer applied on the valve pit cover and frame all as per drawing and as specified and directed. |
| 39 | M&Lfor renewal of construction of brick masonry valve pit chamber of size 900x900x600 mm, with andincluding necessary earth work, PCC, copping, plastering on internal surface of valve pit,Framed work for the valve pit chamber cover made of MS sheet angle equal angle 40x40x5 mm and MS sheet 3 mm thick confirming to Fe410-o and Fe 310-o including welding cutting hinges locking arrangement complete and two coat of synthetic enamel paints over a coat of red oxide primer applied on the valve pit cover and frame all as per drawing and as specified and directed. |
| 40 | M&Lfor renewal of glow sign board of size (length not less than 3.00m and width not less than 0.90m) for E/M installationwith computerised words printed on PVC board including fabrication of work, angle iron, electrical connection with suitable copper wire and LED fittings for independent letters complete all as specified and directedNote: Matter and size of letters shall be approved by Engr-in-Charge. |
| 41 | S&F pre- coated coloured galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa (AZ150) as in roof covering/ clading to wall, including crimping sheet at endfixed with self tapping screws, including dismantling of Asbestos cement (corrugated, semi corrugated, etc) sheets roofing complete all as specified and directed. |
| 42 | S&F 0.5 mm thick galvalume sheet pre-coated coloured for ridge or fixing for closing gable truss suitable for profile pattern sheet fixed with self driving screws, including dismantling of Asbestos cement (corrugated, semi corrugated, etc) sheets as ridge complete all as specified and directed. |
| 43 | S&F structural steel work as in tubular trusses including special shaped washercomplete using ERW or induction butt welded tubes conforming to IS:1161-1979 grade St.-240 complete,including dismantlingold mild steel work of any description complete all as specified and directed |
| 44 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified and directed. |
| 45 | Excavation in post holes (or similar holes) each n. exc 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n. exc 50m and making good surface in soft/loose soil complete all as specified and directed |