| 1 | Providing and fixing of 9 Mtrs long hot dip galvanized octagonal pole with base plate made in single section fitted with erection of the pole on provided RCC Foundation with galvanized nuts etc as required. The following specifications should be adhered for pole & accessories :-a) Pole Top dia - 70mmb) Pole Bottom dia - 175 mmc)Thickness of sheet - 3mmd) Galvanized Base plate of size - 275mm X 275 mm X 16 mme) Set of foundation nut & bolts - 04 nos EN 8 grade galavanized 700 mm length be supplied with galvaized nuts, washers, spacer plate & fixing template. The pole shall be fixed using double nuts.f) The set of GS anchor plates having thickness 4mm should be provided at all the connecting joints for providing support.g) The galvanization shouldbe more than 65 micron DFT both inernally and externally and pole should be designed for at least 169 km/hour max wind speedi)The steel used for manufacturing pole should conform to BSEN 10025 GRADE S 355JO and for base plate steel should be Fe 410 conforming to IS 226 / IS 2062. j) The pole top should be suitably fixed to the bracket using galvanized nuts andbolts of suitable length and dia . |
| 2 | Providing and fixing of double arm brackethaving 1000 mm length including fixing on existing octagonal poleetc as required . |
| 3 | Providing and fixing LED street light with the help of 1.5 mtr long 32 mmdia GI pipe B class suitably bent to the require shape with clamp ,nuts and bolts incuding connection with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc as required. |
| 4 | Supplying and fixing ISMC MC Channelbracket 0.70 mtr long of size 75 mm x 40 mm thickness 4.8 mmwelded with 100 mm dia 30 cm long medium classM S pipe and having suitable size holes on top of the bracketforfixing LED flood light on GI octogonal pole i/c primer and paintingof bracket etc as required as per the direction of Engineer-in-charge |
| 5 | Providing, installation, testing & commissioningof100 watt, designed for all weather condtions with exellent thermal management, made with pressure die cast housing with toughened glass and high power LED\"s with secondary optics and IP66 protection. Efficacy > 110 LPW 10 KV SPD included, operating voltage 220 V, 50 Hzincluding connection with 3core 1.5 sqmm PVC copper cable from light to junction box of pole etc as required as per direction of engg-in-charge. Make : Crompton / Havells/ Philips/ Bajaj. |
| 6 | Providing, installation, testing & commissioningof45 watt, LED street light designed for all weatherconditions with excelent thermal management made with pressure die cast housing with toughned glass and high power LEDs withsecondary optics andIP 66 protection .Efficiency less tha 110 LPW 10 KV SPD includedoperating vol 22 volt 50 hzinclconnection with 3 core 1.5 sqmm PVC copper cable fromlight to junction box of pole .Make- Crompton /Havells /Phillips/Bajaj |
| 7 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3.5 X 95 sqmm XLPE insulated and PVC sheathed armoured aluminium UG Cable size in the existing RCC/ HUME/ METAL/DWC HDPE pipe as required. (Havell\"s or it\"s equivalent to KEI/HPL/Polycab) |
| 8 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3.5 X 95 sqmm XLPE insulated and PVC sheathed armoured aluminium UG Cable size in the existing RCC/ HUME/ METAL/DWC HDPE pipe as required. (Havell\"s or it\"s equivalent to KEI/HPL/Polycab) |
| 9 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3.5 X 50 sqmm XLPE insulated and PVC sheathed armoured aluminium UG Cable size in the existing RCC/ HUME/ METAL/DWC HDPE pipe as required. (Havell\"s or it\"s equivalent to KEI/HPL/Polycab) |
| 10 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3.5 X 50 sqmm XLPE insulated and PVC sheathed armoured aluminium UG Cable size in the existingopen duct as required (Havell\"s or it\"s equivalent to KEI/HPL/Polycab) |
| 11 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3.5 X 25 sqmm XLPE insulated and PVC sheathed armoured aluminium UG Cable size in the existing RCC/ HUME/ METAL/DWC HDPE pipe as required. (Havell\"s or it\"s equivalent to KEI/HPL/Polycab) |
| 12 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3.5 X 25 sqmm XLPE insulated and PVC sheathed armoured aluminium UG Cable size in the existing in open ductas required. (Havell\"s or it\"s equivalent to KEI/HPL/Polycab) |
| 13 | Supplying and making aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(A) 3½ X 25 sq. mm |
| 14 | Supplying and drawing 2.5 sqmm 3 runs FRLS PVC inulated core multicore FR pVC sheathed multi starnded cable with bright annealedelectrrilytic bare copper condcutor in the existing pole for individualLED fixturesand making connection from MCB installed at Looping box of ocagonal pole as required (Havells or its equivalentto KEP /HPL/Polycab |
| 15 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. (A) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 16 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. (A) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 17 | Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 X 95 sq. mm (45 mm) size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 18 | Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 X 50 sq. mm (35 mm) size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 19 | Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 X 25 sq. mm (28 mm) size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 20 | SITC of outdoor type totally enclosed weather proof feeder panel with sloping top of suitable size (minimum size 1000 mmx 900 mm x 400 mm) to accommodate following switch gears and accessories, fabricated from 14 SWG mm thick CRCA sheet suitable for 415 volts, 50 Hz, A.C. supply with gland plate, hinged front openable double leaf doors and locking arrangement suitable size 4 strip 125 Amp aluminum busbar, including providing and fixing switchgears and accessories,powder painted with approved shade, including connection/interconnections with FRLS PVC insulated copper conductor single core cable of suitable size and danger notice plate size 150x100 mm etc. complete as required. The feeder pillar shall be supplied with suitable pedestal of 50 mm x 50 mm x6 mm angle iron frame with 600 mm long legs. The feeder pillar shall be mounted on suitable brick/cement concrete foundation 30 cms. below ground level and 30 cms above ground including finishing etc. complete as required. (A)Fabrication of feeder pillar size 1000 mm x 900 mm x 400 mm made of 2 mm thick CRCA sheet i/c welding, painting, locking arrangement (B) 125 Amp, 4 pole MCCB with thermomagnetic release, 25 KA breaking capacity 01 nos make L&T/Havells/C&S (C) 63 Amp, 3 pole MCCB with thermomagnetic release, 10 KA breaking capacity 04 nos make L&T/Havells/C&S (D) DP MCB \"C\" series 10 KA 40 Amps 05 Nos (E ) DP MCB \"C\" series 10 KA 40 Amps 05 Nos (F) Voltmeter (Range :0-500 v) -01 nos. (G) Ammeter ( Range : 0-100A) -01 Nos (H) Phase indicating LED lamp -03 Nos. |
| 21 | SITC of outdoor type totally enclosed weather proof feeder panel with sloping top of suitable size (minimum size 600 mmx 600 mm x 350 mm) to accommodate following switch gears and accessories, fabricated from 14 SWG mm thick CRCA sheet suitable for 415 volts, 50 Hz, A.C. supply with gland plate, hinged front openable double leaf doors and locking arrangement suitable size 4 strip 63 Amp aluminum busbar, including providing and fixing switchgears and accessories,powder painted with approved shade, including connection/interconnections with FRLS PVC insulated copper conductor single core cable of suitable size and danger notice plate size 150x100 mm etc. complete as required. The feeder pillar shall be supplied with suitable pedestal of 40 mm x 40 mm x 5 mm angle iron frame with 600 mm long legs. The feeder pillar shall be mounted on suitable brick/cement concrete foundation 30 cms. below ground level and 30 cms above ground including finishing etc. complete as required. (A)Fabrication of feeder pillar size 600 mm x 600 mm x 350 mm made of 2 mm thick CRCA sheet i/c welding, painting, locking arrangement (B) 63 Amp, 3 pole MCCB with thermomagnetic release, 10 KA breaking capacity 01 nos make L&T/Havells/C&S(D) DP MCB \"C\" series 10 KA 32 Amps 04 Nos . (C) 24 Hours Analog time switch -01 Nos (D) Pole power contactor 16 Amp -01 Nos. |
| 22 | Providing and fixing of fabricated joint box duly synthetic enalamel painted powder coating CRCA steel 2 mm thick having joint box size 600 mm x 600mm x 450 mmcomprising 100 Amp TPN aluminium bus bar strip on SMC/DMC sheet moulded compound /dual material composite support and openabledoor cover having locking arrangement cable way with proviion of fixing cable galnds at the bottom ,air ventilation groves at the sides, insulators ,earthing studs ,nuts and bolts,rain protectedcanopy cover at top complete etc and priming with red oxide and two or more coats of smoke greyfinsih paintpowder coating complete as per CPRI approved duly mounted on suitablebrick /cement concrete foundation 30 cms below ground level and 30 cms above including finishing etc complete as required. |
| 23 | Supplying and fixing of 4 pole MCCB fixed thermal and fixed magnetic of with release range in Amp 125 amps with breaking capacity of 25 KA at 415 Volt including holes in existing cubilce panel making connections etc as required |
| 24 | Supplying and fixing of 4 pole MCCB fixed thermal and fixed magnetic of with release range in Amp 63amps with breaking capacity of 10 KA at 415 Volt including holes in existing cubilce panel making connections etc as required |
| 25 | Painting of existing outdoor feeder pillars of size 1400 mm X 750 mm X 500 mmfrom both sides including accessories etc. in installed position with one or more coats of Superior Aluminium paints of approved brand after painting of red oxide primer to give an even shade including cleaning, scraping rust, etc. complete as required. Berger/Asian/Shalimar make. |
| 26 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(A) Single pole and neutral |
| 27 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal/ coke and salt ) as required. |
| 28 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation andre-filling as required |
| 29 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 30 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), ncluding dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil |
| 31 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 32 | Centering and shuttering including strutting, propping etc. and removal of form work for :Foundations, footings, bases for columns. |
| 33 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 34 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size). |
| 35 | Add cost index@18 % on DSR item -2023civil |
| 36 | Add GST @ 6.33 % on DSR item -2022 Electrical |