Bids Are Invited For Group C Wiring For Light Point - Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Steel Conduit, With Modular Switch,, Jaipur-Rajasthan

Department Of Telecommunications has published Bids Are Invited For Group C Wiring For Light Point - Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Steel Conduit, With Modular Switch,. Submission Date for this Tender is 18-09-2025. Vehicle Accessories and Component Tenders in Jaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

50892491
Bids Are Invited For Group C Wiring For Light Point - Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Steel Conduit, With Modular Switch,
Tender
Indian
Rajasthan
Jaipur
18-09-2025

Tender Details

Bids Are Invited For Group C Wiring For Light Point - Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Wiring For Light Or Power Plug With 2 X 4 Sq. Mm Frls - Wiring For Light/ Power Plug With 2 X 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Steel Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. , Wiring For Light Or Power Plug With 4 X 4 Sq. Mm Frls - Wiring For Light/ Power Plug With 4 X 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Steel Conduit Along With 2 Nos 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. , Wiring For Circuit Or Submain Wiring Of Size 2 X 1.5 Sq Mm And 1 X 1.5 Sq Mm Earth Wire - Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Size 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Steel Conduit As Required. , Wiring For Circuit Or Submain Wiring Of Size 2 X 2.5 Sq. Mm And 1 X 2.5 Sq. Mm Earth Wire - Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Sizes 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Steel Conduit As Required. , Wiring For Circuit Or Submain Wiring Of Size 4 X 2.5 Sq. Mm And 2 X 2.5 Sq. Mm Earth Wire - Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Sizes 4 X 2.5 Sq. Mm + 2 X 2.5 Sq. Mm Earth Wire Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Steel Conduit As Required. , Supplying And Fixing Of 20 Mm Size Of Steel Conduit - Supplying And Fixing Of 20 Mm Size Of Steel Conduit Along With Accessories In Surface/Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Supplying And Fixing Of 25 Mm Size Of Steel Conduit - Supplying And Fixing Of 25 Mm Size Of Steel Conduit Along With Accessories In Surface/Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Supplying And Drawing Of 3 X 1.5 Sq. Mm Sizes Of Frls - Supplying And Drawing Of 3 X 1.5 Sq. Mm Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Drawing Of 4 X 1.5 Sq. Mm Sizes Of Frls - Supplying And Drawing Of 4 X 1.5 Sq. Mm Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Drawing Of 5 X 1.5 Sq. Mm Sizes Of Frls - Supplying And Drawing Of 5 X 1.5 Sq. Mm Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Drawing Of 6 X 1.5 Sq. Mm Sizes Of Frls - Supplying And Drawing Of 6 X 1.5 Sq. Mm Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Drawing Of 7 X 1.5 Sq. Mm Sizes Of Frls - Supplying And Drawing Of 7 X 1.5 Sq. Mm Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Drawing Of 8 X 1.5 Sq. Mm Sizes Of Frls - Supplying And Drawing Of 8 X 1.5 Sq. Mm Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Drawing Of 3 X 2.5 Sq. Mm Sizes Of Frls - Supplying And Drawing Of 3 X 2.5 Sq. Mm Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Drawing Of 6 X 2.5 Sq. Mm Sizes Of Frls - Supplying And Drawing Of 6 X 2.5 Sq. Mm Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Drawing Of 3 X 4 Sq. Mm Sizes Of Frls - Supplying And Drawing Of 3 X 4 Sq. Mm Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Drawing Of 6 X 4 Sq. Mm Sizes Of Frls - Supplying And Drawing Of 6 X 4 Sq. Mm Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Drawing Of 3 X 6 Sq. Mm Sizes Of Frls - Supplying And Drawing Of 3 X 6 Sq. Mm Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator - Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supplying And Fixing Modular Blanking Plate - Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , Supplying And Fixing Suitable Size Gi Box With 3 Pin 5 Or 6 Amps Modular Socket - Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5/6 Amps Modular Socket Outlet And 5/6 Amps Modular Switch, Connection Etc. As Required. (For Light Plugs To Be Used In Non Residential Buildings). , S F Of Suitable Size Gi Box With 6 Pin 5 Or 6 And 15 Or 16 Amps - Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 Amps Modular Socket Outlet And 15/16 Amps Modular Switch, Connection Etc. As Required. , Supplying And Fixing Of 1 Or 2 Module 75 Mm X 75 Mm Size Or Modules Gi Box - Supplying And Fixing Of 1 Or 2 Module (75 Mm X 75 Mm) Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. , Supplying And Fixing Of 3 Module 100 Mm X 75 Mm Size Or Modules Gi Box - Supplying And Fixing Of 3 Module (100 Mm X 75 Mm) Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. , Supplying And Fixing Of 4 Module 125 Mm X 75 Mm Size Or Modules Gi Box - Supplying And Fixing Of 4 Module (125 Mm X 75 Mm) Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. , Supplying And Fixing Of 6 Module 200 Mm X 75 Mm Size Or Modules Gi Box - Supplying And Fixing Of 6 Module (200 Mm X 75 Mm) Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. , Supplying And Fixing 8 Module 125 Mm X 125 Mm Size Or Modules Gi Box - Supplying And Fixing Of 8 Module (125 Mm X 125 Mm) Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. , Supplying And Fixing 12 Module 200 Mm X 150 Mm Size Or Modules Gi Box - Supplying And Fixing Of 12 Module (200 Mm X 150 Mm) Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. , Supplying And Fixing 18 Module 200 Mm X 150 Mm Size Or Modules Gi Box - Supplying And Fixing Of 18 Module (200 Mm X 150 Mm) Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. , Supplying And Fixing 5 Or 6 Amp Switch Modular Switch Or Socket - Supplying And Fixing Of 5/6 Amp Switch Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supplying And Fixing 15 Or 16 Amp Switch Modular - Supplying And Fixing Of 15/16 Amp Switch Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supplying And Fixing 3 Pin 5 Or 6 Amp Socket Outlet Modular - Supplying And Fixing Of 3 Pin 5/6 Amp Socket Outlet Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supplying And Fixing 6 Pin 15 Or 16 Amp Socket Outlet Modular - Supplying And Fixing Of 6 Pin 15/16 Amp Socket Outlet Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supplying And Fixing Bell Push Modular - Supplying And Fixing Of Bell Push On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supplying And Fixing Modular Indicator - Supplying And Fixing Of Modular Indicator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supplying And Fixing Of 4 Way 4 Plus 12 Ways Double Door Surfaceor Recess Mounting - Supplying And Fixing Of 4 Way (4 + 12), Double Door Surface/ Recess Mounting, Vertical Type, 415 Volts, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs (But Without Mcbs And Incomer ) As Required . , Supplying And Fixing Of Single Pole 5 Amps To 32 Amps - Supplying And Fixing Of Single Pole 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Supplying And Fixing Of Triple Pole 5 Amps To 32 Amps - Supplying And Fixing Of Triple Pole 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Supplying And Fixing 63 A Four Pole 415 Volts Isolator - Supplying And Fixing 63 A Four Pole 415 Volts Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Reqd. , Supplying And Fixing 100 A Four Pole 415 Volts Isolator - Supplying And Fixing 100 A Four Pole 415 Volts Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Reqd. , Supplying And Fixing 125 Amp 36 Ka Fp Mccb In Existing Cubicle Panel - Supplying And Fixing 125 Amp 36 Ka Fp Mccb In Existing Cubicle Panel Board Including Drilling Holes In Cucicle Panel Making Connections Etc. As Reqd. , Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db - Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Reqd. , Supplying And Fixing Dp Sheet Steel Enclosure On Surface Or Recess Along With 25 Or 32Amps 240 Volts C Curve Dp Mcb - Supplying And Fixing Dp Sheet Steel Enclosure On Surface/ Recess Along With 25/32Amps 240 Volts C Curve Dp Mcb Complete With Connections, Testing And Commissioning Etc. As Required. , Supplying And Fixing Tp Sheet Steel Enclosure On Surface Or Recess Along With 16 Or 25 Or 32Amps 415 Volts - Supplying And Fixing Tp Sheet Steel Enclosure On Surface/ Recess Along With 16/25/32Amps 415 Volts C Curve Tp Mcb Complete With Connections, Testing And Commissioning Etc. As Required. , Supplying And Fixing Of 250 Mm Fresh Air Fan In Toilet In Existing Opening - Supplying And Fixing Of 250 Mm Fresh Air Fan In Toilet In Existing Opening I/C Fillup The Extra Space With Particle Board (If Required), Connections, Testing Etc Complete As Required. , Supplying And Fixing 380 Mm Sweep 900 Rpm Heavy Duty Turbo Force Exhaust Fan - Supplying And Fixing 380 Mm Sweep 900 Rpm Heavy Duty Turbo Force Exhaust Fan Complete With Metallic Blades And Louver Fabricated Out Of Gi Sheet Suitable For Operation On 230V Single Phase Ac Supply In The Existing Opening I/C Making The Opening Suitable For Said Size Fan And Making Interconnection Etc As Required. , Sitc Of 400 Mm Sweep Oscillating Type Wall Mounted Cabin Fan - Supplying, Installation, Testing & Commissioning Of 400 Mm Sweep Oscillating Type Wall Mounted Cabin Fan Of Metallic Body Capable Of Working On 230 Volt Ac, 50 Hz Single Phase Supply And I/C Connection Etc. Complete As Reqd. , Providing And Fixing Of S Type Or Fastener Type Fan Hook - Providing And Fixing Of S Type/ Fastener Type Fan Hook For Hanging Of Ceiling Fan I/C Minor Civil Work Shape And Design, All Complete As Directed By Engineer In Charge Etc Complete As Required. , Sitc Of Ip20 2 X 2 36 W Led Recessed Mounting Led Light Fixture - Sitc Of Ip20 2 X 2 36 W Led Recessed Mounting Led Light Fixture Not Less Than 50 Mm Housing Depth Made From Crca Sheet Steel Housing High Purity/ Transmissivity Uv Stabilized Non -Yellowish Diffuser For Uniform Light Distribution. High Efficiency With 4 Kv Internal/ External Surge Protection Bis Certified Isolated Driver Having Efficiency Greater Than 85% With Short & Open Circuit Protection (Integral With Light Fixture). System Lumen Efficacy Of Greater Than Or Equal To 120 Lm/ Watt, Minimum Total System Lumen Output 4400 Lumens, Thd Less Than 10 % P.F. Greater Than Or Equal To 0.95, Cri Greater Than 80 Life Time Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends Cct 3000K/ 4000K/ 5700K/ 6000K/ 6500K (As Per Ansi Bin) Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate (T.C.) And All Other Accessories On Ceiling Suitable For 230 Volts Ac Supply I/C Connection With 1.5 Sq.Mm. Copper Conductor Wire Etc. As Reqd. , Replacement Of Old Conventional Type Cfl Lights With Ip20 1 X 1 18W Led Surface Mounting Led Light Fixture - Replacement Of Old Conventional Type Cfl Lights With Ip20, 1 X 1 18W Led Surface Mounting Led Light Fixture Not Less Than 40 Mm Housing Depth Made From Crca Sheet Steel Housing, High Purity/ Transmissivity Uv Stabilized Non-Yellowish Diffuser For Uniform Light Distribution. High Efficiency With 4 Kv Internal/ External Surge Protection Bis Certified Isolated Driver Having Efficiency Greater Than 85%, With Short & Open Circuit Protection (Integral With Light Fixture). System Lumen Efficacy Of Greater Than Or Equal To 100 Lm/Watt, Minimum Total System Lumen Output 1500 Lumens, Thd Less Than 10 %, P.F. Greater Than Or Equal To 0.95, Cri Greater Than 80, Life Time Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends, Cct 3000K/ 4000K/ 5700K/6000K /6500K (As Per Ansi Bin), Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate (T.C.) In Corridor Suitable For Working On 230V, 50Hz Ac Supply I/C Connection With 1.5Sqmm Pvc Insulated Copper Conductor Cable & Earthing Etc. As Reqd. , Sitc Of Ip20 1 X 4 36W Led Surface Mounting Mid Power Smd Type Led Light Fixture - Sitc Of Ip20, 1 X 4 36W Led Surface Mounting Mid Power Smd Type Led Light Fixture Not Less Than 50 Mm Housing Depth Made From Crca Sheet Steel Housing, High Purity / Transmissivity Uv Stabilized Non -Yellowish Diffuser For Uniform Light Distribution. High Efficiency With 4 Kv Internal/External Surge Protection Bis Certified Isolated Driver Having Efficiency Greater Than 85 Percent, With Short & Open Circuit Protection (Integral With Light Fixture). System Lumen Efficacy Of Greater Than Or Equal To 120 Lm/ Watt, Minimum Total System Lumen Output 4200 Lumens, Thd Less Than 10 Percent, P.F Greater Than Or Equal To 0.95, Cri Greater Than 80, Life Time Of Minimum 50000 Burning Hours With 70 Percent Of Initial Lumen Maintained Till Life Ends, Cct 3000K/ 4000K/ 5700K/ 6000K/ 6500K (As Per Ansi Bin), Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate (T.C.) And All Other Accessories On Ceiling Suitable For 240 Volts Ac Supply I/C Connection With 1.5 Sq.Mm. Copper Conductor Wire Etc. As Reqd. , Sitc Ip20 18 - 20 Watt Led Batten Type Integrated Light Fixture - Sitc Ip20 18 - 20 Watt Led Batten Type Integrated Light Fixture Made From Powder Coated Extruded Aluminum Housing With In Built Driver, System Lumen Efficacy Greater Than Or Equal To 110 Lm/ Watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection, Thd Less Than 10% , P. F. Greater Than Or Equal To 0.95, Cri Greater Than 80, Life Time Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends, Cct 3000K/ 4000K/ 5700K/ 6000K/ 6500K (As Per Ansi Bin), Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate (T.C.) And All Other Accessories On Ceiling Suitable For 240 Volts Ac Supply I/C Connection With 1.5 Sq.Mm. Copper Conductor Wire Etc. As Reqd. , Sitc Of 415V 3 Phase 50 Hz 4 Wire System Sheet Steel Clad Dust And Vermin Proof Cubical - Supplying, Installation, Testing And Commissioning Of 415V, 3 Phase, 50 Hz, 4 Wire System Sheet Steel Clad Dust And Vermin Proof Cubical And Indoor Type Floor Mounted, Free Standing Extensible Type Main M.V. Panel Of Compartmentalized Design And Fabricated Out Of 14 Swg Crca Sheet Steel, Providing & Fixing Of Base Plate/ Channel, P/F The Following Switchgear Arrangements, Complete With Two Nos. Separate Earth Bus Bar Throughout The Length Of The Panel, Termination Arrangement For Various Incoming And Outgoing Cables, Sign Writing, Painting With Powder Coating, Earthing, Numbering, Danger Plate Etc. Complete As Required As Per Specifications Details Given Below. , Dismantling, Servicing And Complete Repairing Other Than Rewinding And Itc Of 1200 Mm Ceiling Fan - Dismantling, Servicing And Complete Repairing (Other Than Rewinding) And Itc Of 1200 Mm Ceiling Fan I/C Cleaning, Oiling, Greasing Etc Complete As Required , Dismantling, Servicing And Repairing Including Rewinding And Itc Of 1200 Mm Ceiling Fan - Dismantling, Servicing And Repairing I/C Rewinding And Itc Of 1200 Mm Ceiling Fan I/C Replacement Of Bush Shaft/ Bearings I/C Cleaning, Oiling, Greasing Etc Complete As Required , Dismantling, Servicing And Repairing Other Than Rewinding And Itc Of 300 Mm Exhaust Fan - Dismantling, Servicing And Complete Repairing (Other Than Rewinding) And Itc Of 300 Mm Exhaust Fan I/C Cleaning, Oiling, Greasing Etc Complete As Required , Dismantling, Servicing And Repairing Including Rewinding And Itc Of 300 Mm Exhaust Fan - Dismantling, Servicing And Repairing I/C Rewinding And Itc Of 300 Mm Exhaust Fan I/C Replacement Of Bush Shaft/ Bearings I/C Cleaning, Oiling, Greasing Etc Complete As Required , Dismantling, Servicing And Repairing Other Than Rewinding And Itc Of 450 Mm Exhaust Fan - Dismantling, Servicing And Complete Repairing (Other Than Rewinding) And Itc Of 450 Mm Exhaust Fan I/C Cleaning, Oiling, Greasing Etc Complete As Required , Dismantling, Servicing And Repairing Including Rewinding And Itc Of 450 Mm Exhaust Fan - Dismantling, Servicing And Repairing I/C Rewinding And Itc Of 450 Mm Exhaust Fan I/C Replacement Of Bush Shaft/ Bearings I/C Cleaning, Oiling, Greasing Etc Complete As Required , Sitc 18 Watt Led Recessed Mounted Down Lighter Fitting - Sitc 18 Watt Led Recessed Mounted Down Lighter Fitting Made From Powder Coated Extruded Aluminum Housing With In Built Driver, System Lumen Efficacy Greater Than 110 Lm/ Watt Output, And All Other Accessories On Ceiling Suitable For 240 Volts Ac Supply I/C Connection With 1.5 Sq.Mm. Copper Conductor Wire Etc. As Reqd. , Supplying And Fixing 5 Or 6 Amp Piano Type Switch On The Existing Switch Box - Supplying And Fixing 5/ 6 Amp Piano Type Switch On The Existing Switch Box/ Cover Including Connections Etc. As Required. , Supplying And Fixing 15 Or 16 Amp Piano Type Switch On The Existing Switch Box - Supplying And Fixing 15/ 16 Amp Piano Type Switch On The Existing Switch Box/ Cover Including Connections Etc. As Required. , Supplying And Fixing 3 Pin 5 Or 6 Amp Socket Outlet On The Existing Switch Box - Supplying And Fixing 3 Pin 5/ 6 Amp Socket Outlet On The Existing Switch Box/ Cover Including Connections Etc. As Required. , Supplying And Fixing 6 Pin 15 Or 16 Amp Socket Outlet On The Existing Switch Box - Supplying And Fixing 6 Pin 15/ 16 Amp Socket Outlet On The Existing Switch Box/ Cover Including Connections Etc. As Required. , Replacement Of Broken Or Damaged Phenolic Laminated Sheet Cover On Existing Switch Box - Replacement Of Broken/ Damaged Phenolic Laminated Sheet Cover On Existing Switch Box I/C Fixing With The Help Of Machine Screws And Washers Etc Complete As Required. , Replacement Of 40 Watt Fluorescent Type Tube Rod With 20 Watt Led Type Tube Rod In Existing - Replacement Of 40 Watt Fluorescent Type Tube Rod With 20 Watt Led Type Tube Rod In Existing 2 X 40 Watt / 1 X 40 Watt Fitting I/C Replacement Of Holder (If Required) And Minor Repairing And Modification Of Wiring I/C Connection, Testing Etc Complete As Required. , Repairing And Painting Of Existing 3 Mtr Height Galvanized Mild Steel Pole - Repairing And Painting Of Existing 3 Mtr. Height Galvanized Mild Steel Pole, The Pole Shall Be Painted With Synthetic Enamel Paint Of Approved Color I/C Ms Pole Box 250 Mm X 200 Mm X 100 Mm At The Bottom Comprising Four Way 25 Amp. Connector Terminal And 1 No. 5/6A Sp Mcb With 3 X 2.5 Sq. Mm Pvc Insulated Pvc Sheathed Copper Conductor Cable Wiring In The Pole From Connector To Luminaries On The Existing Foundation I/C Sign Writing On Pole Box I/C Repairing Of Existing Cement Concrete Foundation Including Two Coats Of Exterior Paint To Suit The Color Of Pole Etc Complete As Directed And As Approved By Engineer In Charge. , Repairing And Painting Of Existing 7 Mtr Height Galvanized Mild Steel Pole - Repairing And Painting Of Existing 7 Mtr. Height Galvanized Mild Steel Pole, The Pole Shall Be Painted With Synthetic Enamel Paint Of Approved Color I/C Ms Pole Box 200 Mm X 150 Mm X 100 Mm At The Bottom Comprising Four Way 25 Amp. Connector Terminal And 1 No. 5A Sp Mcb With 3 X 2.5 Sq. Mm Pvc Insulated Pvc Sheathed Copper Conductor Cable Wiring In The Pole From Connector To Luminaries On The Existing Foundation I/C Sign Writing On Pole Box I/C Repairing Of Existing Cement Concrete Foundation Including Two Coats Of Exterior Paint To Suit The Color Of Pole Etc Complete As Directed And As Approved By Engineer In Charge. , Sitc Of 12 Inch Size Polycarbonate Globe Fittings Alongwith 18 Watt Energy Efficient Led - Sitc Of 12 Inch Size Polycarbonate Globe Fittings Alongwith 18 Watt Energy Efficient Led Bulb As Approved By Engineer In Charge Along With Led Lamp And Suitable For Working On 230 V 50 Hz Ac Supply I/C Fixing On Existing Pole, Connection With Suitable Size Copper Conductor Wire, Testing Etc Complete As Required , Sitc Of 60 Watt Energy Efficient Led Flood Light Luminaries With Inbuilt High Power Leds - Sitc Of 60 Watt Energy Efficient Led Flood Light Luminaries With Inbuilt High Power Leds Generating Cool White Light With Unique Peanut Lens In Pressure Die Cast Aluminum Housing Having 100 Lm / Watt System Efficacy, Ip 66, Polycarbonate Cover, In-Built Driver Unit , Suitable For Work On Single Phase 230 Volts, 50 Hz Ac Supply I/C Making Suitable Arrangement For Fixing The Light On Existing Pole I/C Making Connection Of Fitting From Existing Mcb In Compound Light Box With Help Of Existing 3 Core 2.5 Sq Mm Pvc Insulated And Pvc Sheathed Copper Conductor Cable And Testing Etc Complete As Directed By Engineer In Charge As Reqd , Laying And Fixing Of One Number Pvc Xlpe Insulated And Pvc Sheathed Xlpe Power Cable Of 1.1 Kv Grade Of Upto 35 Sq. Mm On Surface - Laying And Fixing Of One Number Pvc/Xlpe Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Upto 35 Sq. Mm (Clamped With 1Mm Thick Saddle) Size On Wall Surface As Required. , Laying And Fixing Of One Number Pvc Xlpe Insulated And Pvc Sheathed Xlpe Power Cable Of 1.1 Kv Grade Of Upto 35 Sq. Mm In Pipe - Laying Of One Number Pvc/Xlpe Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Upto 35 Sq. Mm Size In The Existing Rcc/ Hume/ Metal/Hdpe Pipe As Required. , Laying And Fixing Of One Number Pvc Xlpe Insulated And Pvc Sheathed Xlpe Power Cable Of 1.1 Kv Grade Of Upto 35 Sq. Mm In Existing Masonry Open Duct - Laying And Fixing Of One Number Pvc Xlpe Insulated And Pvc Sheathed Xlpe Power Cable Of 1.1 Kv Grade Of Upto 35 Sq. Mm In Existing Masonry Open Duct As Reqd , Laying And Fixing Of One Number Pvc Xlpe Insulated And Pvc Sheathed Xlpe Power Cable Of 1.1 Kv Grade Of Upto 35 Sq. Mm In Ground - Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Upto 35 Sq. Mm Size Direct In Ground Including Excavation And Refilling The Trench Etc As Required, But Excluding Sand Cushioning And Protective Covering. , Laying And Fixing Of One Number Pvc Xlpe Insulated And Pvc Sheathed Xlpe Power Cable Of 1.1 Kv Grade Of Upto 35 Sq. Mm In Ground Additional - Laying Of One Number Additional Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Upto 35 Sq. Mm Size Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation And Refilling The Trench Etc As Required, But Excluding Sand Cushioning And Protective Covering. , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For 2 X 6 Sq Mm 19 Mm Size - Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For 2 X 6 Sq. Mm (19Mm) Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. , Supply Of 1 No Xlpe Insulated And Pvc Sheathed Power Cable Of 1 Point 1 Kv Grade Of Size 2 X 6 Sq Mm Aluminum Conductor Armoured Cable - Supply Of 1 No. Xlpe Insulated And Pvc Sheathed Power Cable Of 1.1 Kv Grade Of Size 2 X 6 Sq Mm. Aluminum Conductor Armoured Cable Suitable For Working On 230V, 50 Hz Ac Supply Conforming To Latest Relevant Is Standard, All Complete As Directed By Engineer In Charge. , Providing And Fixing 6 Swg Dia Gi Wire On Surface Or In Recess For Loop Earthing - Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. , Supplying And Fixing Digital Weekly Programmable Time Switch Astronomical Weekly Programmable Alongwith 10 Amp 3 Pole Power Contractor - Supplying And Fixing Digital Weekly Programmable Time Switch (Astronomical Weekly Programmable) Alongwith 10 Amp.3-Pole Power Contractor For Controlling Compound Lighting In The Existing Db Complete With Interconnections Connections, Testing And Commissioning Etc. As Required. , Providing, Laying And Fixing 50 Mm Dia G.I. Pipe A Class In Ground Complete With G.I. Fittings Including Finishing Etc As Required. - Providing, Laying And Fixing 50 Mm Dia G.I. Pipe (A Class) In Ground Complete With G.I. Fittings Including Finishing Etc As Required. , Providing, Laying And Fixing 32 Mm Dia G.I. Pipe A Class In Ground Complete With G.I. Fittings Including Finishing Etc As Required. - Providing, Laying And Fixing 32 Mm Dia G.I. Pipe (A Class) In Ground Complete With G.I. Fittings Including Finishing Etc As Required. , Supplying And Drawing 3 X 2.5 Sq Mm Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing - Supplying And Drawing 3 X 2.5 Sq Mm Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel / Pvc Conduit As Required. , Repairing Of Dust And Vermin Proof Cubical Out Door Double Door Type Floor Mounted - Repairing Of Dust And Vermin Proof Cubical Out Door Double Door Type Floor Mounted, Front And Back Side Openable Feeder Pillar Panel I/C Cleaning, Rubbing And Painting With 02 Coats Of Synthetic Enamel Paint, Repairing/ Replacement Of Lock And Key Arrangement, Replacement Of Connectors And Internal Wiring With Suitable Size Of Copper Conductor Wire I/C Minor Repairing Works I/C Testing Etc Complete As Directed And As Approved By Engineer In Charge. , Replacement Of Faulty Or Damaged 400 Amp Tpn Switch Fuse Unit With Hrc Fuses In Feeder Pillar - Replacement Of Faulty/Damaged 400 Amp Tpn Switch Fuse Unit With Hrc Fuses In Feeder Pillar I/C Dismantling Of Faulty Item And Fixing The New I/C Connection With Suitable Size Of Copper Conductor Wire ,Testing Etc Complete As Required. M/S L&T And Ss Make , Replacement Of Faulty Or Damaged 125 Amp Tpn Switch Fuse Unit With Hrc Fuses In Feeder Pillar - Replacement Of Faulty/Damaged 125 Amp Tpn Switch Fuse Unit With Hrc Fuses In Feeder Pillar I/C Dismantling Of Faulty Item And Fixing The New I/C Connection With Suitable Size Of Copper Conductor Wire ,Testing Etc Complete As Required. M/S L&T And Ss Make , Replacement Of Faulty Or Damaged 63 Amp Tpn Switch Fuse Unit With Hrc Fuses In Feeder Pillar - Replacement Of Faulty/Damaged 63 Amp Tpn Switch Fuse Unit With Hrc Fuses In Feeder Pillar I/C Dismantling Of Faulty Item And Fixing The New I/C Connection With Suitable Size Of Copper Conductor Wire ,Testing Etc Complete As Required. M/S L&T And Ss Make , Replacement Of Faulty Or Damaged 96 Mm X 96 Mm Ampere Meter With Selector Switch And 3 Nos Ct Of Suitable Rating In Feeder Pillar - Replacement Of Faulty/ Damaged 96 Mm X 96 Mm Ampere Meter With Selector Switch And 3 Nos Ct Of Suitable Rating In Feeder Pillar I/C Dismantling Of Faulty Item And Fixing The New I/C Connection With Suitable Size Of Copper Conductor Wire ,Testing Etc Complete As Required. M/S L&T And Ss Make , Replacement Of Faulty Or Damaged 96 Mm X 96 Mm Volt Meter With Selector Switch In Feeder Pillar - Replacement Of Faulty/ Damaged 96 Mm X 96 Mm Volt Meter With Selector Switch In Feeder Pillar I/C Dismantling Of Faulty Item And Fixing The New I/C Connection With Suitable Size Of Copper Conductor Wire ,Testing Etc Complete As Required. M/S L&T And Ss Make , Replacement Of Faulty Or Damaged 400 Amp Din Type Hrc Fuses In Feeder Piller - Replacement Of Faulty/Damaged 400 Amp Din Type Hrc Fuses In Feeder Pillar I/C Dismantling Of Faulty Item And Fixing The New I/C Connection With Suitable Size Of Copper Conductor Wire ,Testing Etc Complete As Required. M/S L&T And Ss Make , Replacement Of Faulty Or Damaged 125 Amp Din Type Hrc Fuses In Feeder Piller - Replacement Of Faulty/Damaged 125 Amp Din Type Hrc Fuses In Feeder Pillar I/C Dismantling Of Faulty Item And Fixing The New I/C Connection With Suitable Size Of Copper Conductor Wire ,Testing Etc Complete As Required. M/S L&T And Ss Make , Replacement Of Faulty Or Damaged 63 Amp Din Type Hrc Fuses In Feeder Pillar - Replacement Of Faulty/Damaged 63 Amp Din Type Hrc Fuses In Feeder Pillar I/C Dismantling Of Faulty Item And Fixing The New I/C Connection With Suitable Size Of Copper Conductor Wire ,Testing Etc Complete As Required. M/S L&T And Ss Make , Sitc Of Borewell Submersible Motor Pump Set In Stainless Steel Internals Like Rotor, Pump Shaft ,Strainer Suitable For Discharge - Sitc Of Borewell Submersible Motor Pump Set In Stainless Steel Internals Like Rotor, Pump Shaft, Strainer Suitable For Discharge Of 10 To 17.5 Cubic Meter Per Hour. Form At Total Head Of 170 -80 Meter From All Causes Having 10.00 Hp Motor Capacity , 2900 Rpm Suitable For Operation On 3 Phase, 415 Volts, 50 Hz Ac Supply I/C Connection And S/F Suitable Size Of Bore Cover With 2 Nos. Pipe Clamp And Pipe Cover And All Other Accessories Etc. As Reqd. , Supplying And Lowering Of Heavy Duty Upvc Pipe Of Size 50 Mm Dia Isi Mark With Other Accessories For Jointing - Supplying And Lowering Of Heavy Duty Upvc Pipe Of Size 50 Mm Dia Isi Mark With Other Accessories For Jointing The Entire Pipe Length Like Nipple ,Flange Bend, Union ,Clamps, Sockets At End I/C Making Connection With Existing Delivery Line Etc Complete As Required. , S And F 18 Mm Dia Nylon Rope Of Double Twisted For Firmly Holding Of The Submersible Pump - S/F 18 Mm Dia Nylon Rope Of Double Twisted For Firmly Holding Of The Submersible Pump Motor Set Etc. Complete As Reqd. , S And L Of 3 Core 4 Sq. Mm Flexible Pvc Insulated And Pvc Sheathed Flat Submersible Cooper Conductor Cable - S/L Of 3 Core 4 Sq. Mm Flexible Pvc Insulated And Pvc Sheathed Flat Submersible Cooper Conductor Cable Of 1.1 Kv Grade From Exiting Panel To Pump Motor Surface With Suitable Clamp Or In Recess By Cutting And Repairs Etc. I/C P/M Water Proof M Seal Joint With Pump Connection Submersible Cable Connection With The Exiting Panel Testing Etc. As Reqd , S And M Connection Of The Pump With 65 Mm Dia Gate Valve For Non Rising Stem Isi Marked With Test Certificate Bronze - S/M Connection Of The Pump With 65 Mm Dia Gate Valve For Non Rising Stem Size Isi Marked (With Test Certificate) Bronze Screwed Type Accessories For Delivery And Suction Pipe Line I/C Connection Etc Complete As Required , S And M Connection Of The Pump With 65 Mm Dia B Class Gi Pipe For Delivery And Suction Pipe Line - S/M Connection Of The Pump With 65 Mm Dia B Class Gi Pipe For Delivery And Suction Pipe Line With All Accessories Like Tee, Elbow Bends ,Sockets Flanges I/C Cutting, Welding, Threading And Nut Bolts I/C Connection Etc Complete As Required , Providing Fixing Suitable M.S. Sheet Bore Well Cover With Nut Bolt Etc As Reqd - Providing Fixing Suitable M.S. Sheet Bore Well Cover With Nut Bolt Etc As Reqd. , Pdg And Fixing Suitable Size Clamps For Holding Submersible Pump Pipe On Top Of Borewell Cover - Pdg And Fixing Suitable Size Clamps For Holding Submersible Pump Pipe On Top Of Borewell Cover I/C Fixing With Suitable Size Nut Bolt Etc. As Reqd. , Supplying And Fixing 3 Phase 415 Volts 50 Hz Ac Supply Pump Controller In Sheet Steel Enclosure - Supplying And Fixing 3 Phase 415 Volts, 50 Hz, Ac Supply Pump Controller In Sheet Steel Enclosure With Rain Water Protection Suitable For 10.00 Hp Submersible Pump Set Operation Along With Contactor, Overload Relay With Suitable Range, With Protection For Single Phasing, Phase Reversal, Auto Restart With 30 Sec Delay, Indicating Lamps For Supply On & Pump On, Single/ Dual Type Volt Meter & Ammeter Etc As Reqd , Sitc Of Centrifugal Type Energy Efficient Mono Block Pump With Ci Impeller Suitable For A Discharge - S/I/T/C Of Centrifugal Type Energy Efficient Mono Block Pump Set With Ci/Naryl Impeller Suitable For A Discharge Of 17 To 6 Lps ( Approximate ) Against A Total Head Of 30 To 45 Meter From All Cause Having Capacity Of 12.5Hp , 3 Phase Suitable For Operation On 415V , 50Hz ,3Phase Ac Supply Fixed On Exiting Cement Concrete Foundation I/C Necessary Nuts And Bolts And Making Good The Same Cement Concrete Foundation And Having Suction And Delivery Sizes Of 80 Mm X 65 Mm Complete All Accessories Etc As Reqd , S And M Connection Of The Pump With 80 Mm Dia Foot Valve Isi Marked With Test Certificate Bronze Screwed Type - S/M Connection Of The Pump With 80 Mm Dia Foot Valve Isi Marked (With Test Certificate) Bronze Screwed Type Accessories For Delivery And Suction Pipe Line I/C Connection Etc Complete As Required. , S And M Connection Of The Pump With 80 Mm Dia Gate Valve For Non Rising Stem Isi Marked With Test Certificate Bronze Screwed Type - S/M Connection Of The Pump With 80 Mm Dia Gate Valve For Non Rising Stem Isi Marked (With Test Certificate) Bronze Screwed Type Accessories For Delivery And Suction Pipe Line I/C Connection Etc Complete As Required. , S And M Connection Of The Pump With 80 Mm Dia Horizontal Lift Check Valve Isi Marked With Test Certificate Bronze Screwed Type - S/M Connection Of The Pump With 80 Mm Dia Horizontal Lift Check Valve Isi Marked (With Test Certificate) Bronze Screwed Type Accessories For Delivery And Suction Pipe Line I/C Connection Etc Complete As Required. , S And M Connection Of The Pump With 65 Mm Dia Vertical Lift Check Valve Isi Marked With Test Certificate Bronze Screwed Type - S/M Connection Of The Pump With 65 Mm Dia Vertical Lift Check Valve Isi Marked (With Test Certificate) Bronze Screwed Type Accessories For Delivery And Suction Pipe Line I/C Connection Etc Complete As Required. , S And M Connection Of The Pump With 65Mm Dia Globe Valve For Rising Stem Isi Marked With Test Certificate Bronze Screwed Type - S/M Connection Of The Pump With 65Mm Dia Globe Valve For Rising Stem Isi Marked (With Test Certificate) Bronze Screwed Type Accessories For Delivery And Suction Pipe Line I/C Connection Etc Complete As Required. , S And M Connection Of The Pump With 65 Mm Dia B Class Gi Pipe - S/M Connection Of The Pump With 65 Mm Dia B Class Gi Pipe For Delivery And Suction Pipe Line With All Accessories Like Tee, Elbow Bends ,Sockets Flanges I/C Cutting, Welding, Threading And Nut Bolts I/C Connection Etc Complete As Required. , S And M Connection Of The Pump With 80 Mm Dia B Class Gi Pipe - S/M Connection Of The Pump With 80 Mm Dia B Class Gi Pipe For Delivery And Suction Pipe Line With All Accessories Like Tee, Elbow Bends ,Sockets Flanges I/C Cutting, Welding, Threading And Nut Bolts I/C Connection Etc Complete As Required. , Sitc Of Energy Efficient 02 Hp De Watering Sewage Sump Pump - S/I/ T/C Of Energy Efficient 02 Hp De-Watering (Sewage) Sump Pump Capable Of Handling Solid Waste Of Max 22 Mm Having Discharge Rate Of 1.6 To 6 Lps With A Strong Stainless Steel Body And A Thermal Overload Protector, Pre-Fitted With A Float Switch Which Ensures That The Pump Is Automatically Switched On And Off As Per Requirement With Heavy-Duty Construction Made From Graded Cast Iron, Carbon + Silicon Carbide Mechanical Seal, Makes The Pump With A Total Head Of 10-15 Meter Having Capacity Of 02 Hp , 3 Phase Suitable For Operation On 415V , 50Hz ,3Phase Ac Supply I/C Fixed In Exiting Pump Room I/C Necessary Nuts And Bolts And Making Good The Same And Having Suction And Delivery Sizes Of 50 Mm Complete All Accessories Etc As Reqd , Sitc Of 415V, 3 Phase, 50 Hz, 4 Wire System Sheet Steel Clad Dust And Vermin Proof Cubical - Supplying, Installation, Testing And Commissioning Of 415V, 3 Phase, 50 Hz, 4 Wire System Sheet Steel Clad Dust And Vermin Proof Cubical And Indoor Type Floor Mounted, Front And Side Openable Pump Panel Of Compartmentalized Design And Fabricated Out Of 14 Swg Crca Sheet Steel, Providing & Fixing Of Base Plate / Channel, P/F The Following Switchgear Arrangements, Complete With Two Nos. Separate Earth Bus Bar Throughout The Length Of The Panel, Termination Arrangement For Various Incoming And Outgoing Cables, Sign Writing, Painting, Earthing, Numbering, Danger Plate Etc. Complete As Required As Per Specifications Details Given Below. , S And L Fixing Of One Number Xlpe Insulated Aluminum Conductor Armoud Power Cable Of 1.1 Kv Grade Of 4 X10 Sq Mm Size As Required. - Supplying And Laying/ Fixing Of One Number Xlpe Insulated Aluminum Conductor Armoud Power Cable Of 1.1 Kv Grade Of 4 X10 Sq Mm Size As Required. , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For 4 X 10 Sq Mm - Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For 4 X 10 Sq. Mm Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. , Providing And Fixing 6 Swg Dia G I Wire On Surface Or In Recess For Loop Earthing - Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Alongwith Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required. , Installation Of 1 Point 5 Or 2 Tr Capacity Split Ac Units - Installation Of 1.5 / 2.0 Tr Capacity Split Ac Units With Indoor & Outdoor Unit I/C Fixing The Refrigerant Piping With Insulation, Cutting, Brazing, Laying The Cable Along With The Piping Connections, Repairing The Minor Leakages Of The Complete System I/C Testing, Commissioning Of Split Type Ac Unit Etc. Complete As Reqd. , Pdg And Fixing 1 By 4 Inch Dia Copper Refrigerant Piping - Pdg And Fixing 1/4 Inch Dia Copper Refrigerant Piping I/C Covering Of Copper Piping With Polystyrene Insulation I/C Cutting, Brazing, Jointing, Bends, Sockets Etc As Reqd. , Pdg And Fixing 5 By 8 Inch Dia Copper Refrigerant Piping - Pdg And Fixing 5/8 Inch Dia Copper Refrigerant Piping I/C Covering Of Copper Piping With Polystyrene Insulation I/C Cutting, Brazing, Jointing, Bends, Sockets Etc As Reqd. , Provision Of Top Up Or Additional Charging Of R-22 Or 32 Gas - Provision Of Top Up / Additional Charging Of R-22/32 Gas Upto Specified Pressure In Existing Window Ac / Split Ac Units I/C Flushing, Gas Charging, Testing Etc Complete As Reqd. , S F Suitable Size Ms Stand For Placement Of Split Type Ac Outdoor Unit - S/F Suitable Size Ms Stand For Placement Of Split Type Ac Outdoor Unit Made Out Of 16 Gauge Powder Coated Ms Sheet I/C Fixing With Help Of 4 Nos. Fasteners For Grouting On Wall / Floor, Etc. Complete As Required. , Providing And Fixing 20 Mm Dia Heavy Duty Pvc Pipe - Providing And Fixing 20 Mm Dia Heavy Duty Pvc Pipe For Drainage Purpose Of Ac Unit I/C Connection, Testing Etc As Required. , Supplying And Fixing 25 Amp Moduler Type Starter - Supplying And Fixing 25 Amp. Moduler Type Starter Switch On The 2 Module Modular Plate And Switch Box Including Connections Etc. As Required. , Supplying And Fixing Of 3 X 2.5 Sq Mm Pvc Insulated And Frls - Supplying And Fixing Of 3 X 2.5 Sq. Mm Pvc Insulated And Frls Round Sheathed Multi Core Bright Annealed Bare Copper Conductor Heavy Duty Industrial Cable For Voltage Grade Up To 1100 Volts As Per Is 694-1990 I/C Fixing On Wall With Suitable Clamp/Saddle Etc. Complete As Reqd. , Earthing With G I Earth Plate - Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/ Coke And Salt As Required. , Providing And Fixing G I Strip In G I Pipe - Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. , Providing And Fixing G I Strip On Surface - Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. , Providing And Fixing Earth Bus 50 Mm X 5 Mm Copper Strip On Surface For Connection Etc As Reqd - Providing And Fixing Earth Bus 50 Mm X 5 Mm Copper Strip On Surface For Connection Etc. As Reqd. , Supplying And Fixing Flexile Photo Luminescent Based Glow In The Dark Sheeting With Luminous Properties - Supplying And Fixing Flexile Photo Luminescent Based Glow In The Dark Sheeting With Luminous Properties Enclosed In A Weather Proof Uv Stabiles Film With Uv Screen Printing Exit Signage Of Dimension 100 Mm X 300 Mm And Thickness Minimum 0.20 Mm Plus Or Minus 10 Percent Fixed On 1 Mm Thick Rigid Self Adhesive Sheet , Suitable For Service Temp Minus 20 To Plus 80 Degree C, Glow Visible Darkness, Fungi Static, Non Toxic, Non Radioactive, Conforming To Latest Health And Safety Signs And Signage Regulation 1996 And Nfpa 101 Life Safety Code Performance Requirements And Certified & Test Report By Govt Agencies Complete As Required. , Supplying And Fixing Flexile Photo Luminescent Based Glow In The Dark Sheeting With Luminous Properties - Supplying And Fixing Flexile Photo Luminescent Based Glow In The Dark Sheeting With Luminous Properties Enclosed In A Weather Proof Uv Stabiles Film With Uv Screen Printing Staircase Steps Up/ Down Direction With Symbol Signage Of Dimension 100 Mm X 300 Mm (For Fixing On Wall At Staircase Landing) And Thickness Minimum 0.20 Mm Plus Or Minus 10 Percent Fixed On 1 Mm Thick Rigid Self Adhesive Sheet , Suitable For Service Temp Minus 20 To Plus 80 Degree C, Glow Visible Darkness, Fungi Static, Non Toxic, Non Radioactive, Conforming To Latest Health And Safety Signs And Signage Regulation 1996 And Nfpa 101 Life Safety Code Performance Requirements And Certified & Test Report By Govt Agencies Complete As Required. , Refilling Of 4.5 Kg Co2 Type Fire Extinguisher Test Certificate To Be Provided - Refilling Of 4.5 Kg Co2 Type Fire Extinguisher Test Certificate To Be Provided With Suitable Gas/ Chemical Powder Upto Specified Pressure I/C Loading And Unloading , Transportation Of Cylinder From Rttc, Jaipur To Refill Workshop I/C Providing Suitable Length Hose Pipe And Re Fixing The Same As Per Direction Of Engineer-In-Charge. , Refilling Of 5 Kg Dcp Or Abc Type Fire Extinguisher Test Certificate To Be Provided - Refilling Of 5 Kg Dcp/ Abs Type Fire Extinguisher Test Certificate To Be Provided With Suitable Gas/ Chemical Powder Upto Specified Pressure I/C Loading And Unloading, Transportation Of Cylinder From Rttc, Jaipur To Refill Workshop I/C Providing Suitable Length Hose Pipe And Re Fixing The Same As Per Direction Of Engineer In Charge. Total Quantity : 10564

Key Value

Document Fees
Refer document
EMD
INR 66817.0 /-
Tender Value
INR 33.40 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail