| 1 | Dismantling RCC using deploying machineries,clearing away and carefully stacking materials useful for re-use for any thickness of walls(PWD SOR 2025-2026, P,No 30,Unicode W-OO35) |
| 2 | Dismantlig BrickMasonry in cement mortar walls under 3m, clearing away and carefully stacking materials useful for re-use for any thickness of walls (PWD SOR 2025-2026, UnicodeW-0015) |
| 3 | Dismantling Plain Cement Concrete, clearing away and carefully stacking materials useful for re-use for any thickness of walls(PWD SOR 2025-2026, P,No 30, Unicode W-OO34) |
| 4 | Dismantling of Pressed Tiles & Weathering Course clearing away and carefully stacking materials useful for re-use for any thickness of walls (PWD SOR 2025-2026, P,No 30,Unicode W-OO37) |
| 5 | Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers. Foundation |
| 6 | ORDINARY SOIL (SS20B) Earth work excavating and depositing on bank with initial lead of 10m & initial lift of 2m in Sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam and ordinary soil including excavated earth (SS20B) |
| 7 | Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 8 | Plain Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers. -Mixing by manual means |
| 9 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require onlynominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner , vertical stiffener,side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). Foundation |
| 10 | Supplying and erecting centering for plane surfaces such as RCC Floor/Roofbeam,Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting above 3.60m upto 4.90m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boardinglaid over Steel adjustable Span of Size 2m x 2m (expandable upto 3.60m) and Silver OakJoists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel AdjustableTelescopic Props of Size 2.40 x 3.0m (expandable upto 4.90m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c and with Cross bracings provided at two levels at a spacing of 1.80m etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). Roof beam |
| 11 | Supplying and erecting centering for plane surfaces such as RCC Floor Slab, RoofSlab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in allfloors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). |
| 12 | Supplying and erecting steelcentering including necessary supportsFor plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall berovidedas directed by the departmental Officers. (Payment for centering shall be given after theconcrete is laid). |
| 13 | Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.-Mixing by mechanical means |
| 14 | Providing and laying in position, Standardised Concrete Mix M-25 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). Basement |
| 15 | Providing and laying in position, Standardised Concrete Mix M-25 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). Ground Floor |
| 16 | Supplying, fabricating and fixing in position of steel Fe 550 grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete cover blocks to maintain the cover as required. The rate including cost of all materials, bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages, laying at all levels, fixing in position, cost of cover blocks and GI binding wires etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge |
| 17 | Add additional labour for works above plinth/Basement level in every upper floor over the preceding floor or Below Ground level of every 3.50m depth. |
| 18 | Brick work in following Cement Mortar using best quality Burnt Clay Brick of size 9” x 4 3/8” x 2 3/4” with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,completecomplying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge. Basement |
| 19 | Brick work in following Cement Mortar using best quality Burnt Clay Brick of size 9” x 4 3/8” x 2 3/4” with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,completecomplying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge. Ground Floor |
| 20 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand),12mmthick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curingetc. complete complying with standard specification and as directed by the departmentalofficers. |
| 21 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfacesand curing, etc., in all floors complying with standard specification and as directed by thedepartmental officers |
| 22 | Painting New Plastered Wall Surface with Two finishing coats of ready mixed(Emulsion) of approved quality and colour over one coat priming coat in all floorsincluding the cost of primer etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should begot approved by the Executive Engineer before use on works.) |
| 23 | Painting new iron works such as steel doors, windows, ventilators, window bars,balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost ofpriming coat etc., complete complying with standard specification and as directed by thedepartmental officers. (The make, quality and colour of paint should be got approved bythe Executive Engineer before use on works.) |
| 24 | Supplying and Erecting Pull and Push Type Rolling Shutter with ISI make of approved size and sectionusing 18 GI sheet. The shutter shall be painted withone coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc |
| 25 | Dadooing walls with following best approved quality, white / colour glazed tiles conformingto IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant TileEpoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use onworks) |
| 26 | Paving the floor with best quality vitrified Tiles of following size and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laidover cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and threecrushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying withstandard specification and as directed by the departmental officers. (The make and brandof the tiles should be got approved by Executive Engineer before use on works) |
| 27 | Paving the floor with best approved quality fine polished Granite Stone Slabs of following size and Variety with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., complete complying with standard speicification and as directed by the departmental officers.(The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work) |
| 28 | Finishing the top of roof with one course of machine pressed tiles of following size ofapproved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand)12mm thick mixed with water proofing compound conforming to ISS at 2% by weightof cement used and the joints pointed neatly to full depth of tiles with the same cementmortar mixed with red oxide and water proofing compound including curing etc., completecomplying with standard specification and as directed by the departmental officers |
| 29 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mmuniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportionof brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters ofapproved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. |
| 30 | Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification |
| 31 | Supplying , fixing and roofing with colour galvalume sheet of 0.47mm thick with allnecessary accessories such as J/V bolt and nuts of suitable length with suitablebitumen washers complete complying with standard specification and as directed by the departmental officers. |
| 32 | Supply and installation ofmodern 3 seater Granite Garden bench, with back Colour including cost of Bench and conveyance and fixing all labour charges. |
| 33 | FRP Door Sutter with FRP Door Frames made out of FRP Sheets of 3mm thick of over all size 65mm x 50mm with rebate suitably reinforced using MS Angle / Flats, cost of holdfasts and Solid Core FRP Shutter Panel of 5mm thick and hollow core frames of 3m wall thickness for styles and rails etc., of sizes specified by Engineers |
| 34 | Supply and delivery and fixing of 2000 litre capacity of HDPE tank asper IS 12701 / 1996 including loading, unload-ing, transportation and labour charges for fixingof the GI pipes and specials for pipe connectionworks including cutting, threading and fixingcharges etc. WD-M1416 |
| 35 | Supply and fixing of TNEB meter board suitable for 32A three phase service connection with 3 Nos. 32A fuse unit (500V) 32A neutral link and earth link (1\" x 1/8\" copper flat) on TW plank of size 600mm x 450mm x 19mm with supporting TW reepers of 1\" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit with 1 No 40 Amp 30 MA Four Pole RCD / RCCB (Higher End) with suitable necessary connection SD 128 |
| 36 | Supply and fixing of TNEB meter board suitable for 32A single phase service connection with 32A fuse unit (500V) 32A neutral link and earth link (1\" x 1/8\" copper flat) on TW plank of size 375mm x 300mm x 19mm with supporting TW reepers of 1\" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit with 1 No 40 Amp 30 MA Double Pole RCD / RCCB (Lower End) with suitable necessary connection SD-126 |
| 37 | Wiring with 2 x 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigidpipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum sheet cover with TWswitch box and 5A FT switch and making good of the concealed portion with suitable colour for PVC concealed light /fan Point (for electronic regulator) (5 points per coil) SD-25 |
| 38 | Wiring with 2 x 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigidpipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x 113mm TW switchbox with 3mm thick hylem sheet cover for 5A 3 pin non inter locking wall socket with 5A flush type switch withcontinuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitablecolour for concealed PVC plug point SD-38 |
| 39 | Supply and run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour SD-43 |
| 40 | Supply and run of 2 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with contiinuous earth wire connection of 6 sq.mm copper wire and making good of the concealed portion with suitable colour SD-59 |
| 41 | supply and fixing of 1200mm (48\") sweep AC ceiling fan 5 star rated complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18\") SD 106 |
| 42 | Supply and Fixing of 4’ 18W Crystal Glass LED Tube Light Fitting M-1211 |
| 43 | Supplying and erecting in position of 250 liters capacity Industrial Model Reverse Osmosis Water-cum Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No., Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings. The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact.(PWD SoR 2025-26, Unicode M-0721) |
| 44 | Supply fixing and errection of CCTV Camara including cost and Conveyance of all materials to site etc complete as per Specification 4MP IP Bullet / Dome Camera. (PWD SoR M-2806) |
| 45 | Supply fixing and errection of CCTV Camara including cost and Conveyance of all materials to site etc complete as per Specification Network Video Recorder16 Channel - 2 SATA (2 Nos. Hard Disk) (PWD SoR M-2197) |
| 46 | Supply fixing and errection of CCTV Camara including cost and Conveyance of all materials to site etc complete as per SpecificationHard disc for NVR 4 TB(PWD SoR M-2221) |
| 47 | Supply fixing and errection of CCTV Camara including cost and Conveyance of all materials to site etc complete as per Specification Rack With Accesssories -12UM-2228 |
| 48 | Supply fixing and errection of CCTV Camara including cost and Conveyance of all materials to site etc complete as per Specification Rack With Accesssories -4U M-2225 |
| 49 | Supply fixing and errection of CCTV Camara including cost and Conveyance of all materials to site etc complete as per Specification Armoured LAN & CCTV Cable (CAT-6) (PWD SOR Unicode M-2184) |
| 50 | Supply fixing and errection of CCTV Camara including cost and Conveyance of all materials to site etc complete as per Specification Led tv for display |