Tender For Special Repair/Replacement Of Over Head Lt Line Into Ug Cable Feeder Pillar Boxes And Other Associated Items At Dinjan Mil Stn Under Ge Dinjan, dinjan-Assam

Military Engineer Services has published Tender For Special Repair/Replacement Of Over Head Lt Line Into Ug Cable Feeder Pillar Boxes And Other Associated Items At Dinjan Mil Stn Under Ge Dinjan. Submission Date for this Tender is 08-09-2025. Overhead Line Tenders in dinjan Assam. Bidders can get complete Tender details and download the document.




Tender Notice

50881347
Tender For Special Repair/Replacement Of Over Head Lt Line Into Ug Cable Feeder Pillar Boxes And Other Associated Items At Dinjan Mil Stn Under Ge Dinjan
Tender
Indian
Assam
Dinjan
08-09-2025

Tender Details

Tender For Special Repair/Replacement Of Over Head Lt Line Into Ug Cable Feeder Pillar Boxes And Other Associated Items At Dinjan Mil Stn Under Ge Dinjan; 1 Excavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth, for foundations, etc, or for shafts, wells, cesspits, manholes, pier holes, cable trench etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. 2 Excavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth, for foundations, etc, or for shafts, wells, cesspits, manholes, pier holes, cable trench etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in hard/dense soil complete all as specified and directed. 3 Returning filling in with excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. 4 Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed. 5 M&L for clear sand cushioning with dry clean sand for protection of cable,15cm below the cable and 8cm above the cable, complete all as specified and as directed. Note : Punned thickness shall be measured for payments. 6 Supply and laying unreinforced precast concrete cable cover class LV, type 1, flat size 250 x 150 x 40 mm for cable protection with breaking capacity as per IS complete all as specified and as directed. 7 S&F Sub-Class B brick, well burnt, laid breadth-wise along the axis of cable laid in trenches over sand cushion for cable protection complete all as specified and as directed. 8 Boring of holes horizontal for laying pipe (minimum depth 0.75 mtr from top level) under the road pavement, hard standing using trenchless technology complete all as specified and as directed.Note : Cost of accessories required for making hole/bore deemed to be included in the quoted rate. 9 S&F RCC cable route indicator with embrossing mark as LT cable, of size75 cm x 15cm x 7.5cm alongwith foundation size 75cm x 30 cm x 30cm duly painted with color coding complete all as specified and directed. 10 Supply, install, testing and commissioning of dual nature switch timer based automatic street light control panel. The panel should be suitable for 3 phase 15kw power load. The control panel should be maintenance free in design and setting accessible via mobile app (with Bluetooth connectivity). the mobile app should be allow users to (customize the ON & OFF timing based on natural light lux level sensor or local sunset/sunrise (astro) or manual time setting or combination of all options). the mobile app should also have facility ton set input voltage rage. the control panel have 2 smart timers along with suitable power contactors and incoming-outing MCBs should be enclosed in a pole/wall mountable rust proof, electric shock proof, termite proof and FR grade Polycarbonate enclosure conforming current to IP66 and circuit should also have provision for manual operation (i.e. sensor by pass option & controlling current phase selection option at least from 2 phase). Note : The fixing arrangement on pole/wall to be included in the quoted price. 11 Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 185 sq.mm 3.5 Core, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items.(2) Excavation and earth work shall be measured and paid separately.complete all as specified and directed. 12 SAll as per Item No.11here in above but of size 150 sq.mm 3.5 Core. 13 All as per Item No.11here in above but of size 120 sq.mm 3.5 Core. 14 All as per Item No.11here in above but of size 70 sq.mm 3.5 Core. 15 All as per Item No.11 here in above but for of size 50 sq.mm 3.5 Core. 16 All as per Item No.11here in above but of size 35 sq.mm 3.5 Core. 17 All as per Item No.11here in above but of size 25 sq.mm 3.5 Core. 18 All as per Item No.11here in above but of size 25 sq.mm 2 Core. 19 All as per Item No.11here in above but of size 16 sq.mm 4 core. 20 All as per Item No.11here in above but of size 16 sq.mm 2 core. 21 All as per Item No.11here in above but of size 10 sq.mm 4 core. 22 All as per Item No.11here in above but of size 10 sq.mm 2 core. 23 M&L for GI pipe light grade with all fittings complete grouted in ground all as specified for 32mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified and directed. 24 All as per Item No.23here in above but of size 50 mm bore. 25 All as per Item No.23here in above but of size 80 mm bore. 26 Dismantling/taking down old aluminium steel reinforced (ACSR) conductor of any size any type from LT overhead line including all jumper, cross arms, clamps, bolts, nuts etc and keeping serviceable materials in safe custody for reuse in the work complete all as specified and as directed 27 Dismantling cross-arms of M.S. channel or angle sections etc. complete and stackingaside serviceable materials for re-use with in 50m and removing unserviceable materials from site of workcomplete all as specified and as directed. 28 Dismantling the all cable from panel, poles, MCB Main DBs taking out the cable loop stretching out the cable, carrying out end termination with new lugs, proper thimbling, fixing the joint kits connecting back to the new/existing panel board by means of nuts, bolt & washers of any size any type complete all as specified and as directed.Note : (i) The work includes necessary excavation to take out the loop and laying the cable, putting proper cable protection bricks using the old retrieved bricks and refill the area properly and spreading any surplus soil.(ii) The cost of AI lugs, joint kit shall be measured and paid separately under respective items. 29 Supply, jointing and testing XLPE cable straight through joints including jointing materials and accessories complete, cold shrinkable outdoor cable joint kit suitable for XLPE 1100 Volts (Earthed) cable of size 70 Sqmm to 150 Sqmm 3.5/4 Core complete all as specified and as directed.Note : Excavation and earth work shall be measured and paid separately. 30 Supply, jointing and testing XLPE cable straight through joints including jointing materials and accessories complete, cold shrinkable outdoor cable joint kit suitable for XLPE 1100 Volts (Earthed) cable of size 25 Sqmm to 50 Sqmm 2/3.5/4 Core complete all as specified and as directed.Note : Excavation and earth work shall be measured and paid separately. 31 Supply, jointing and testing XLPE cable straight through joints including jointing materials and accessories complete, cold shrinkable outdoor cable joint kit suitable for XLPE 1100 Volts (Earthed) cable of size 6 Sqmm to 16 Sqmm 2/3.5/4 Core complete all as specified and as directed.Note : Excavation and earth work shall be measured and paid separately. 32 S&F PVC cable Junction Box IP66 halogen free and weather proof for out door installation sizenot less than 200 x 150 x 100 mm suitable for street light incoming and outgoing cables up to 10 to 25 sqmm 4 core (with terminal) & inclusive of MCB SP 10 Amp, 60A 04 strip aluminium Bus Bar, including nuts,bolts,cable glands & MS clamps fixed to pole complete all as specified and directed. 33 Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire unarmoured, electric control cables with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade passed throuh PVC conduit medium grade of size Min 20mm complete all as specified and directed. 34 M&L Earthing complete with Galvanised steel earth plate 60cmx60cmx6mm thick electrode, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 m below ground level , connected to GI earth strip 25 X 4mm up to test point by means of bolts ,nuts , check nuts and washers of GI including excavation and earth work, PCC 1:3:6 type C-1 pit, 20mm dia GI pipe medium grade, watering pipe and 20 mm bore GI pipe, light grade for protection of earth strip, MS angle iron frame 40x40x3mm, 10mm thick RCC 1:2:4 type B-1 cover reinforced with 6mm dia MS bars @ 75mm C/C both ways and with MS handle made out of 12mm dia bars, PGI Funnel, wire mesh etc complete all as shown in electrical Plate No 03 of SSR Part-I and connected to earthing test point all as specified or indicated including testing on completion complete and including taking down old u/s. 35 Supply, install,testingand commissioning outdoor type LT panel of size 1.2m x 1.2m x 0.6m ,factory made totally encloseddust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricatedwith latest IP-65 and having proper locking arrangement with magnetic door closing system, neoprene gasket and gland packingat cable entry/ exit pointin both front and rear door painted with powder coated paint and Aluminium bus bar 400 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform type CM(1:3:6) painted with white/red colour all around the panel board complete with the following items:- (Main Panel NO-I) unit area.Note : Foundation to be included in the quoted priceIncoming :-(a)MCCB, 4 Pole, 250 Amp,415 V, 25 kA (I/C) - 01 No., Thermal magnetic release (adjustable type).(b)Multifunction 3 phase meter duly showing voltage, AMPs, KW, Frequency, PF, KVA, KVAR(c) Phase indicator lamps (RYB) -set of 3(d) Aluminium bus bar 4 strip - 400 amps(length should not be less than 0.7 m).(e)Internal connection by Aluminium strip from mcb/mccb to busbar and busbar to MCCB/MCB etcOutgoing :- (a) MCCB, 4 Pole,100Amp,415 V, 25 kA - 03 Nos, Thermal magnetic release.(b)MCB,TPN, 32A, 240 V, 16 kA- 05 Nos.(b) MCB,TPN, 63A, 240 V, 16 kA- 03 Nos. (For street light and 01 extra) 36 Supply, install,testingand commissioning outdoor type LT panel of size 1.2m x 1.2m x 0.6m ,factory made totally encloseddust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated with latest IP-65 and having proper locking arrangement with magnetic door closing system, neoprene gasket and gland packingat cable entry/ exit pointin both front and rear door, painted with powder coated paint and Aluminium bus bar 300 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform type CM(1:3:6) painted with white/red colour all around the panel board complete with the following items:- (FP-II , III, V & VI).Note : Foundation to be included in the quoted priceIncoming :-(a)MCCB, 4 Pole, 160 Amp,415 V, 36 kA - 01 No Thermal Magnetic release (adjustable type).(b)Multifunction 3 phase meter duly showing voltage, AMPs, KW, Frequency, PF, KVA, KVAR(c) Phase indicator lamps (RYB) -set of 3(d) Aluminium bus bar 4 strip - 300 amps( Length should not be less than 0.7m).(e)Internal connection by Aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etcOutgoing :- (a) MCCB, 4 Pole,100Amp,415 V, 36 kA - 01 NosThermal Magnetic release.(b) MCB, TPN, 63A, 240 V, 16 kA- 01 Nos. (for street light cook house and 01 extra)(c) MCB, TPN, 32A, 240 V, 16 kA- 05 Nos. 37 Supply, install,testingand commissioning outdoor type LT panel of size .6m x .6m x 0.5m , factory made totally encloseddust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated with latest IP-65 and having proper locking arrangement with magnetic door closing system, neoprene gasket and gland packingat cable entry/ exit pointin both front and rear door, painted with powder coated paint and Aluminium bus bar 200 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform type CM(1:3:6) painted with white/red colour all around the panel board complete with the following items:- (Bus bar panel Panel). (a) (a) MCCB, 4 Pole,100Amp,415 V, 25 kA - 01 Nos, Thermal magnetic release. (b)Aluminium bus bar 4 strip -200 ampshaving hole drilled on bus bar for fixing of cables (Length should not be less than 0.4m) (c)Internal connection by Aluminium strip/Wire from mcb/mccb to busbar and busbar to mccb/mcb etc Note : Foundation to be included in the quoted price 38 M&L for plain cement concrete (1:4:8) type D-2,using 40mm graded stone aggregate as in foundations of stay assembly, poles, strut etc complete all as specified and as directed. 39 Dismantling of insulators of any type from LT poles of any size and type and setting aside complete all as specified and as directed. 40 Dismantling of GI earth wire 4.0mm or any size complete all as specified and as directed.

Key Value

Document Fees
INR 500 /-
EMD
INR 87000.0 /-
Tender Value
INR 43.50 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail