}

Providing, Installation Of Pumping Machineries With Other Other Electro-Mechanical Accessories At Cwr Site Of Marar Water Supply Schemeunder Bankura Mechanical Division, Phe Dte. Dist: Bankura, bankura-West Bengal

Public Health Engineering Department has published Providing, Installation Of Pumping Machineries With Other Other Electro-Mechanical Accessories At Cwr Site Of Marar Water Supply Schemeunder Bankura Mechanical Division, Phe Dte. Dist: Bankura. Submission Date for this Tender is 12-09-2025. Pumping Machiney Tenders in bankura West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

50881194
Providing, Installation Of Pumping Machineries With Other Other Electro-Mechanical Accessories At Cwr Site Of Marar Water Supply Schemeunder Bankura Mechanical Division, Phe Dte. Dist: Bankura
Tender
Indian
West Bengal
Bankura
12-09-2025

Tender Details

Providing, Installation Of Pumping Machineries With Other Other Electro-Mechanical Accessories At Cwr Site Of Marar Water Supply Schemeunder Bankura Mechanical Division, Phe Dte. Dist: Bankura-2 Supply, delivery of clear water vertical wet type submersible pump suitable for bore well conforming to IS:8034(and as amended threreafter) with standard MOC for potable clear cold water andcapable with a continuous rated-2 pole suitable wet type vertical squirel cage induction motor conformoning to IS: 9283(and as amended threafter) suitable for operation in AC Three phase 415V, 50Hz(category B motor) and as per technical specification givebn in NIT Method of starting – star deltaTube Well size-250mma) Discharge-29 M3/Hour, Total head -29MtrN.B-T.C. & G.C. needed. (Manufacturer test certificate along with curve chart should be submitted at the time of delivery) (Make-Approved) 3 Supply and delivery of the following materials at site : - 4 Supply, delivery and storage at site 80 mm dia UPVC Column pipe medium gauge both side 8 TPI threaded and one side heavy type socket other site rubber cap for threaded protector Standard (17kg/cm2).(Make-Approved) 5 1.5 mtr long 6 3 mtr long 7 Supply and delivery at site 80 mm dia CI Top Adaptor with flange (Single clamp) (Make-Approved) 8 Supply and delivery at site 80 mm dia CI Bottom Adaptor(small) (Make-Approved) 9 Supply and delivery of following valves 10 150mm dia CIDF menually gear operated Butterfly valve as per IS-13095/1991 & Flange Drilled to 1538/1993(P.N-1.0)( Make-Approved) 11 200 mm dia CIDF menually gear operated Butterfly valve as per IS-13095/1991 & Flange Drilled to 1538/1993(P.N-1.0)( Make-Approved) 12 Supply, delivery and storage at site of following cables 13 2.5 sqmm 3core, 1100 Volt grade copper water proof PVC insulated submersible flat submersible cable,Conforming To IS : 694 As Amended Up To Date.(Make-Approved) 14 70 mm2 3 Core, 1100V grade XLPE insulated aluminium Armored cable ,cable As Per IS-7098 (Part 1) 2011 with Up To Date Amendments, (Make-Approved) 15 Withdrawing of defective submersible pump motor set from river bed tube well after disconnecting of all the electrical and hydraulic connections as per direction of EIC. 16 Laying of cable of 10sqmm in a underground trench in single tier formation (Horizontal) the trench size 460mm x 760mm average depth withoutbrick protection on the top andas required including filling the space inbetween the trench with shifted soil leveling up and restoring surface duly rammed as per direction of EIC. 17 Laying of cable of 70sqmm in a underground trench in single tier formation (Horizontal) the trench size 460mm x 760mm average depth withoutbrick protection on the top andas required including filling the space inbetween the trench with shifted soil leveling up and restoring surface duly rammed as per direction of EIC. 18 Lowering of repaired submersible pump motor set from river bed tube well after disconnecting of all the electrical and hydraulic connections as per direction of EIC 19 Installation andtesting commissioning of the above pumping machiner valve, column pipe , top bottom adapetr(Sl No 1-3&4.1) with dismantling the old existing colum pipe adapters from the pump after withdrawlingand cost of hiring D.G set ( if required) to complete the jobs includingLaying of two nos 2.5 sqmm 3 coreCablein an underground trench, all respect as per tecnical specification and as per direction of E.I.C. 20 Making 300mm(W) x 300mm(B) x 900 mm (H) size rising main supporting brick pillar at least 300mm depth from ground level to pumping floor level and neat cement finish all complete as per direction. 21 Add: 18% GST 22 Add: 1% Cess

Key Value

Document Fees
Refer document
EMD
INR 13000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail