| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil, all as specified and as directed. |
| 2 | Excavating over areas, exc 1.5 m deep and n exc 3.0 m deep and getting out in soft / loose soil, all as specified and as directed. |
| 3 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, laying of cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil including forming bottom surface to required level or slope, complete all as specified and directed. |
| 4 | Excavating in trenches, n exc 1.5 m wide and exc 1.5 m in depth; for foundation, laying of cable etc. n exc 10 sq m on plan and n exc 3.0 m in depth and getting out in hard/ dense soil including forming bottom surface to required level or slope, complete all as specified and directed. |
| 5 | M&L for plain cement concrete (1:3:6), type C-1(using20 mm graded crushed stone aggregate) for making good surface where cutting road / hard standing / path, complete all as specified and directed. |
| 6 | M&L for plain cement concrete (1:2:4), type B-1(using 20 mm graded stone aggregates) in bases / pedestals for pipe lines, mud stops or chamfered on edges and including demolition of existing PCC, complete all as specified and directed. |
| 7 | Returning filling in soft / loose / hard / dense soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and directed. |
| 8 | Removal of surplus excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point, complete all as specified and directed. |
| 9 | Labour only for attending break down of followings size of pipeline bursting / cracks and including cleaning / removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and including by using suffient dewatering pumps, all as specified and directed.Note 1 :- The quoted rate is deemed to be include the following:-(i) Arrangement of suitable Pump sets for dewatering at the time of attending break down (ii) Necessary labour / Suitable Gaskets/etc..trade men for attending break down.(iii) does not include Labour element required for fixing GI/CI/DI/MS pipes, specials, fittings etc.Note 2 :-M&L forEarth work,Lead joints, supply only GI/CI / DI / MS pipes, specials, fittings will be measured and paid seperately under relevant items of BOQ. |
| 10 | 50 mm bore GI/MS/CPVC/UPVC pipe |
| 11 | 80 mm bore GI pipe |
| 12 | 200 mm bore MS pipe |
| 13 | 400 mm bore DI/MS pipe |
| 14 | 600 mm bore DI/MS pipe |
| 15 | Supply only DI K7 water supply pipe lines of size 400 mm bore and including taking down old DI water mains with spigot and socket ends and lead joints including burning out joints and recovering lead, complete all as specified and directed. Note : (i) Earth work will be measured and paid seperately.(ii) Labour required for fixing of DI pipe rate is included in Sl. item No. 9.00 of BOQ. |
| 16 | All as per Serial item No. 10.00 above but of DI K9 for 600 mm bore. |
| 17 | Supply only MS ERW pipe of size 400 mm bore, 5.6 thickfor inserting the pipe in position and including making leak proof joints and including taking down old pipe, complete all as specified and directed. |
| 18 | Supply only Galvanised steel (GI) pipe medium grade of size 25mm bore, all as specified and directed. |
| 19 | Supply only Galvanised steel (GI) pipe medium grade of size 50mm bore, all as specified and directed. |
| 20 | Supply only Galvanised steel (GI) pipe medium grade of size 80mm bore, all as specified and directed. |
| 21 | Supply only DI specials such as bends (any type, radius and angle) tapers any type, straight, bend, increasing, decreasing or double socket etc.) tee pieces single branch, \"Y\" junction, double branch, cross (all sockets or sockets and spigot) collars, caps and plugs upto 400 to 600 mm bore, complete all as specified and directed. |
| 22 | Supply only DI specials mechanical joint / expansion joint / Cast Iron detachable joint of 400 mm bore and including necessary nuts, bolts and neoprane rubber rings, complete all as specified and directed. |
| 23 | M&L for Lead joints for 400 mm bore sizes of DI Pipes, complete all as specified and directed. |
| 24 | M&L for Spindle of sluice valve of 400 to 600 mm bore made out of EN-8 steel with check nut made out of MS/CI and including replacing perished gland packing, rubber gasket, bolts and nuts including taking down old spindle of the following sizes, complete all as specified and directed. |
| 25 | M&L for Spindle of sluice valve of 100 to 200 mm bore made out of EN-8 steel with check nut made out of MS/CI and including replacing perished gland packing, rubber gasket, bolts and nuts including taking down old spindle of the following sizes, complete all as specified and directed. |
| 26 | Surface dressing in soft /loose soil not exeeding 15 cm deep, across the pipe lines etc, and including site clearence, cutting and cleaning of branches / bushes / plants / grass obstructing the pipe lines /valves / chambers / sumps / OHTs on either sides and water supply Installation area including disposal of materials up to a distance not exceeding 50 m, complete all as specified and directed. |
| 27 | Supply and fixMS flange 25 mm thickfor 600 mm bore to be welded to MS pipe and including flange joint 6 mm thick rubber gasket with necessary nuts and bolts etc., complete all as specified and directed. |
| 28 | Supply and fixMS flange 20 mm thickfor 400 mm bore to be welded to MS pipe and including flange joint 6 mm thick rubber gasket with necessary nuts and bolts etc., complete all as specified and directed. |
| 29 | M&L for masonary valve chamber of size 900x900x900 mm (Internal dimensions) including excavation and earth work in any type of soil and 100 mm thick PCC 1:4:8 type D2 foundation, brick work in cement mortar 1:6, plastering internal and external surface 15mm thick in cement mortar 1:4, PCC 1:3:6 type C1 (using 20mm graded stone aggregate) coping, 50x50x6mm mild steel angle iron, 5 mm thick mild steel plate cover complete with locking arrangement painting steel and iron surfaces with synthetic enamel paint two coats over a coat of zinc chrome primer, complete all as specified and directed. |
| 30 | All as per Serial item No. 24.00 butvalve chamber of size 600x600x600 mm |
| 31 | Supply and layingDI K7 water supply pipe lines of size 400 mm borein trenches/ floor or in plane area and including taking down old DI water mains with spigot and socket ends and lead joints including burning out joints and recovering lead, complete all as specified and directed. Note: (i) Earth work will be measured and paid seperately. |
| 32 | Supply and laying DI K9 water supply pipe lines of size 600 mm borein trenches/ floor or in plane area and including taking down old DI water mains with spigot and socket ends and lead joints including burning out joints and recovering lead, complete all as specified and directed. Note: (i) Earth work will be measured and paid seperately. |
| 33 | Supply and laying MS ERW pipe of size 400 mm bore, 5.6 thickfor inserting the pipe inin trenches/ floor or in plane area position and including making leak proof joints and including taking down old pipe, complete all as specified and directed.Note: (i) Earth work will be measured and paid seperately. |
| 34 | Supply and laying MS ERW pipe of size 200 mm bore, 5.6 thickfor inserting the pipe inin trenches/ floor or in plane area position and including making leak proof joints and including taking down old pipe, complete all as specified and directed.Note: (i) Earth work will be measured and paid seperately (if any). |
| 35 | Supply only MS specials such as bends (any type, radius and angle) tapers any type, straight, bend, increasing, decreasing or double socket etc.) tee pieces single branch, \"Y\" junction, double branch, cross (all sockets or sockets and spigot) collars, caps and plugs upto 600 mm bore, complete all as specified and directed. |
| 36 | M&L for 200 bore CI Butterfly valve BS-5150lever operated with necessary rubber gaskets, nuts,bolts, and washers of suitable size including taking down exiting valve, complete all as specified and directed. |
| 37 | All as per item No 31.00 above but of size 100 mm bore |
| 38 | All as per item No 31.00 above but of size 80 mm bore |
| 39 | All as per item No 31.00 above but of size 50 mm bore |
| 40 | M&L for 50mm Gun metal gatevalve with iron wheel head screwed both ends for iron pipeincluding taking down exiting valve, complete all as specified and directed. |
| 41 | M&L for Poly electrolite, complete all as specified and directed. |
| 42 | M&L for Air release valves of size 100mm dia including taking down of old one with necessary nuts, bolts, complete all as specified and directed. |
| 43 | M&L for Scour Valve 100mm diaincluding taking down of old one with necessary nuts, bolts, complete all as specified and directed. |
| 44 | M&L for preparation of old painted steel surfaces of any description, any width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 45 | M&L and repairs for existing digital water meter, sensors with wiring suitable for 400mm dia pipe line, complete all as specified and directed. |
| 46 | M&L for rectification of existing defective flanged joints with rubber or fibre gasket complete with necessary nuts, bolts, flanges and washers all as specified for the 600mm DI K9 , complete all as specified and directed.Note:- (a) quoted rates are inclusive of cutting of DI pipes, jointing materials and preparation of new flanged sockets, dewatering and refixing the same at existing place.(b) necessary DI pipe & fittings will be measured and paid separately, complete all as specified and directed. |
| 47 | All as per item No 41.00 above but of 400mm dia MS/DI pipes |
| 48 | All as per item No 41.00 above but of 200mm dia MS pipes |
| 49 | Cleaning of bushes/small plants surround the E/M installations including removing debris to a distance not exc 50m including cutting of tree branches, complete all as specified and directed. |
| 50 | M&L for repairs to water level indicator 36\" dia as per IS and including replacement of necessary heavy duty float, counter weight, heavy duty driving gear nylon wire and painting the exposed surfacewith two coats of synthetic enamel over a coat of red oxide primer, complete all as specified and directed. |
| 51 | M&L for servicing to Sluice/Scour/Air release valves of size 100mm dia by applying greasing, glands, nut & bolts and misc necessary, complete all as specified and directed. |
| 52 | Supply and fixing in repair 600 mm borecastiron sluice valve of class PN-1.6 long body type heavy duty ISI marked flanged (IS-1535) flanged ends with iron wheel andBronze spindle including rubber gaskets, joints and nuts and bolts extra including taking down adjusting volws, complete all as specified and directed. |
| 53 | All as per item No 47.00 above but of size 400 mm bore |
| 54 | All as per item No 47.00 above but of size 80 mm bore |
| 55 | Taking up / down 100mm bore, water tubing and connection from trenches/walls/floors(of any location) for replacement / re-use in old / new location, complete all as specified and directed.Note: Necessary earth work if any will be measured paid separtaly under relevint items. |
| 56 | All as per item No 50.00 above but of size 80 mm bore |
| 57 | All as per item No 50.00 above but of size 50 mm bore |
| 58 | All as per item No 50.00 above but of size 25 mm bore |
| 59 | S&F in repairs of GI tubing of 25 mm dia medium grade ISI Marked laid in trenches/laid under floor on ground including all fittings such as elbow, union, reducer, tees, bends etc and shortlength, complete all as specified and directed. |
| 60 | All as per item No 54.00 above but of size 50 mm bore |
| 61 | All as per item No 54.00 above but of size 80 mm bore |
| 62 | All as per item No 54.00 above but of size 100 mm bore |
| 63 | Relaying / Refixing 100mm bore GI tubing and connections in new or old positionafter thoroughly cleaning, with new fittings, laid in frenches, complete all as specified and directed.Note: GI tubing obtained from item No 52 to 55 to be re-used. |
| 64 | All as per item No 58.00 above but of size 80 mm bore |
| 65 | All as per item No 58.00 above but of size 50 mm bore |
| 66 | All as per item No 58.00 above but of size 25 mm bore |
| 67 | Relaying / Refixing 100mm borte GI tubing and connections in new or old positionafter thoroughly cleaning, withnew fittings, fixed to walls and ceilings or laid in floor, complete all as specified and directed.Note: GI tubing obtained from item No 52 to 55 to be re-used. |
| 68 | All as per item No 62.00 above but of size 80 mm bore |
| 69 | All as per item No 62.00 above but of size 50 mm bore |
| 70 | All as per item No 62.00 above but of size 25 mm bore |
| 71 | Cutting of road/hard standing not exc 30cm in width and not exc 60cm in depth for normal/laying of water tubing including returning filling and making good the disturbed surfaces using PCC 1:2:4 type B-1 using 20mm graded stone aggregate on top 100mm layer and fair fininshing the surface without using any extra cement, complete all as specified and directed. |
| 72 | Reapir / Replacement of Burnt out Mother Board to the exsting clamp on Ultrasonic flow meter new mother board Model No-91WA1-AA2B22ACA4AA, Make:- Endress + Hauser, including removing and re- instalklation charges, supervision charges aqnd calibration charges etc., complete all as spercified and directed. |
| 73 | Total Amount in Figures |
| 74 | Quoted Amount in Words |