Tender For Special Repairs To 07X Toilets And Sewage Line Of Bldg Number P-158 Of 461 Dsc Pl Hqsouthern Comd Andspl Repairs To Sewage Line, Septic Tank & Manhole Tochitragupta Colonyin The Area Of Age B/R (Central) Under Ge ( North) Pune; 1 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tilesand rubbish off the premises complete all as specified and as directed. 2 Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. 3 M & L 75 mm thick cement concrete (1:4:8) type D2 (using 40mm grade broken stone aggregate) as in sub base complete all as specified and as directed. 4 M&L non-skid coloured mate finish full bodytiles7 to 8mm thick (square/rectangular) area of each tile exceeding 0.08sqm but not exceeding 0.36 sqm as in floor etc set and jointed in neat cement slurry and pinted in white or coloured cement to match the tiles including 20mm thick screed bed or bedding layer in CM 1:6complete all as specified. 5 M&L glazed ceramic coloured tiles of size 600 x 300 x 7 to 8 mm thick, on vertical surfaces of walls such as skirting , dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar 1:3complete, all as specified. 6 Taking down cement plaster on brick/ stone walling including raking out joints, hacking for key, scrubbing down painted surface with wire brush and cleaning the surface with water etc complete all as directedNOTE: this items of work is to be operated upto 15 m building height which is included in quoted rate.. 7 Material and labour for rendering 15mm thick in cement mortar (1:6) on fair faces of brick or concrete or chhajja surfaces finished even and smooth without using extra cement all as specified and as directed. NOTE: this items of work is to be operated upto 15 m building height which is included in quoted rate. 8 M&L for Preparation and applying two coats of Oil bound distemper at old wall/Ceiling surface over a coat of alkali resistant primer along 1.5 mm thick wall putty complete all as specified and directed. 9 M&L Cutting chases, pinning in, making good to facings where requiredin stone walls and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelve, lintels etc and cutting chases for concealed water tubing or concealed conduct wiring etc and making good cuttingn exc 10 cm girth complete all as specified and directed by Engr-in-Charge. 10 S&F in repair 15mm bore tubes medium grade galvanized ISI marked with all fittings short pieces and fixed complete to walls, floor, ceiling etc all incl taking down existing G I tubing as specified. 11 S&F in repair 20mm bore tubes medium grade galvanized ISI marked with all fittings short pieces and fixed complete to walls, floor, ceiling etc all incl taking down existing G I tubing as specified. 12 Taking down chowkats or frames not exc.1.5 sq. m each with shutters (without taking off shutters from the frames) complete all as specified and directed 13 -Ditto- all as per Item No.12 abovebutexc. 1.5 sq. m but n exc 4 sqmeachcomplete all as specified and directed 14 S&F Factory made 100 % solid wood plastic composite(WPC) door frame, single rebate 90 mm x 45 mm made from wood plastic composite (Single extruded process) material with density 780 Kg/ Cumcomplete all as specified and directed.NOTE: During Fixing of chowkhat, surface Shall be make good in plumb with existing finishes like cement plaster, similar wall tile,floor tile etc and as per site requirement. 15 S&F for 35 mm thick flush shutterssolid core construction, with block board core and plywood face panels, commercial type on both sides,both face covered with decorative face veneer with lipping/frame to match including second class hard wood plain cover fillets 35X6mm all around the shutters complete all as specified and directed. 16 Material and labour Factory made solid panel wood grain PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing all as specified and as directed. Note : All screws shall be self tappingand length of Screw not less than 50 mm. 17 S&F Stainless steel butt hinges 100mm complete all as specified and directed.NOTE :- All screws shall be self tapping chrome plated and length ofscrew not less 38 mmcomplete all as directed and specified. 18 S&F Aluminium Tower Bolt of 200 mm long (selected quality as approved)fixed with Self Tapping screws complete all as directed and specified. 19 S&F Aluminium Handle of 200 mm long ( selected quality as approved ) fixed with Self Tapping screws complete all as directed and specified. 20 S&F Aluminium sliding door bolts, plate type,bright bolt not less than 12mm dia with and incl a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate 250 mm long( selected quality as approved ) complete all as directed and specified. 21 Supply and fix in repairSS square grating 5x5mm size and thickness 0.8 -1mm of grade SS 304 with/without hole complete all as specified. 22 Supply and fix in repair cast iron nahani/floor trap, 75mm dia of outlet, with grating including joining to waste pipe fixed in PCC (1:2:4) type B-1 (using 20mm graded broken stone aggregates) complete all as specified and as directed. 23 S&Fin repair bevelled edge mirror of selected quality glass , mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers . 24 Supply and fix aluminium powder coated louvered ventilator with provision of space for exhaust fan using Jindal aluminium section - 20604 or equivalent make as specified including glass 3mm thick ordinary quality, frosted and stainless steel wire mesh 0.36mm dia wire an d1.40mm qperture etccomplete all asspecified and directed. 25 S&F in repairs hand shower chromium plated (health faucet) 15 mm bore, (ABS body) with 8mm dia. 1.20 metre long spirochrome flexible tube & wall hook, Cat No. F8030401AB of make Cera or equivalent of make as per Appx A as approved by GE. complete all as specified and as directed. 26 S&F in repairchromium plated shower rose 115mm size square (without arm) with swivel joints including fixing arm/ pipe all as specified. Make Johnson Cat part No: S0006C or equivalent make as per Appex A as approved by GE. 27 S&F in repair cast copper alloy CP Shower arm square 230mm long with flange complete all as specified and directed by Engr-in-Charge . MakeJohnson cat part No: S0001C1 or equivalent make as per Appx A as approved by GE. 28 S&F in repair angle cock with flange chromium plated cast copper alloy screwed down complete all as specified. Make: Johnson Eco Cat part No: T3910C or of equivalent make as per Appx A as approved by GE. 29 Supply and fixin repair 10 litres capacityPVC valveless, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets, 32mm dia PVC flush pipe and connections to pipes, making good the disturbed surfaces make cera complete all as specified and as directed. 30 Supply and fix in repair 15mm dia PVC connection 450mm long including PTMT nuts etc complete all as specified and as directed 31 S&Fin repair 15 mm bore Fancy type Chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule. 32 S&F in repairs Pillartaps Swan Neck quarter turn suitable for 15mm bore pipe fancy type brass CP screwed for iron pipe or brass ferrulecomplete all as specified. Make: JohnsonMagna series Cat part No: T2804C or of equivalent make as per Appx A as approved by GE. 33 S&F in repair Toilet paper holder of stainless steel, all as specified and directed. Make: Johnson Fusion series Cat part No: T3254C or equivalent as approved by the GE. 34 S & F in repair Brass Chromium plated towel rail all as specified and directed. Make: Johnson Delta series Cat part No: T1350Cor of equivalent make as per Appx A as approved by GE 35 S&F in repair Brass Chromium plated towel ring all as specified and directed. Make:Johnson Delta series Cat part No: T1351Cor of equivalent make as per Appx A as approved by GE 36 S&F in repairs bib cock long nose quarter turn suitable for 15mm bore pipe with flange fancy type brass CP with, screwed for iron pipe or brass ferrulecomplete all as specified. Make: JohnsonVIVA series Cat part No: T4806 or of equivalent make as per Appx A as approved by GE 37 S&F in repairs Two Way (2 in 1) bib taps with wall flange quarter turn suitable for 15mm bore pipe fancy type brass CP, screwed for iron pipe or brass ferrule complete all as specified and as directed.. Make: JohnsonVIVA series Cat part No: T4808C or of equivalent make as per Appx A as approved by GE. 38 S&F in repirs wall mixer brass chromium plated quarter turn 2 in 1 with bend pipe with provision for over head shower withbend pipe on upper side connecting legs and wall Flangessuitable for fixing with GI pipes 15mm dia complete all as specified and as directed.Make: JohnsonVIVA series Cat part No: T4821C or of equivalent make as per Appx A as approved by GE. 39 S&Fin repair corner glass shelf of size 300mm dia and 8mm thick with chromium plated railing, fixed with and including chromium plated bracket complete all as specified and as directed. 40 S&F in repairglass shelf 450mm x 150 mm x 8mm thick with chromium plated railing fixed with and including chromium plated brackets complete aii as specified and as directed. 41 Material and labour for machine cut cudappah stone slab 20-25 mm thick as in lintels, shelves, vertical supports, fixed with neat cement slurry or arldite,including rubbing and polishing,includind dismantling of existing complete all as specified and as directed 42 M&L Granite (of any type), 18-20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills,cooking platform,WHB platform and like in cement mortar (1:4) incl pointing in white cement (1:2) using marble dust with admixer of pigment to match with marble shadelaid over and including 15mm thick screed bedin CM 1:4 Including dismantling of existing stone complete all as specified. 43 Labour only for full round moulding to 18 to 20mm thick granite slab complete all as directed. 44 Supply & Fixed rotational moulded polyethylenewater storage tank 3 layer white colour water tank , extra heavy duty UV stablized, roto moulded vergin FDA approved, 03 layered body thered lid.Air ventilator lid of 1000L capacity , over all dia 850mm. overall height 1000mm and dia of main hole 420mm , make prayag cat part no: WT-3LL-05, sintex or equivalent , the internal and external surface of tanks are smooth , clean and free from any hidden internal defects, hoisted and fixed in position includind supply and fixnecessary GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer, 20mm dia PTMT valve high pressure of PTMT with epoxy coated Al rod & high density plastic ball and 20mm brass stop cock etc complete including dismantling existing water tank all as specified and directed. 45 S&F in repairs vitreous china counter Top wash hand basin, Ivory, size 560 mm x 470 mm x 190mm flat back excluding taps but including CI brackets, chromium plated brass waste coupling, chain and plug, waste fitting including waste pipe, union and PVC waste pipe 32mm dia, of required length, cutting for and pinning in ends of bracket or errecting stand complete all as specified and as directed. Make: Cera Model: OVAL Cat Part No –S2030104 equivalent make as per Appx A as approved by GE. 46 S&F in repair Vitreous china Urinal, Full stall type, white withwaste pipe and CP brass spreader complete including providing andfixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plug with and including 60mm long brass screws, pointing around urinal back in cement;flush pipe, grating and union for discharge pipe including brass CP urinal spreader for fixing with 15 mm dia pipe complete all as specified and as directed 47 S&F in repair vitreous China squatting pan Orissa pattern size 580 x 440mm white with integral foot rest ( excluding flushing cistern and flush pipe), including P-trap (PVC) 100 mm dia., connection to flushing pipe, anti-syphonage pipe complete including making good to floor all as specified.Cera/Prayag/Johnson Pedder. 48 S&F for vitreous china European type wash down water closet pan, (Pedestal pattern), white including plastic seat cover white closed pattern with flat bottom and cover with mild steel chromium plated hinging device and fixing bolts, P or S trap, necessary inlet and outlet connections including making good complete all as specified and as directed. 49 Excavationin trenches not exc. 1.5 m wide and not exc. 1.5 m in depth for foundation, cable etc. or for shafts, wells, cesspits, manholes, pier holes, pole etc. n. exc 10 sq m on plan and getting out in hard/ dense soil complete all as specified and as directed. 50 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick with soils complete all as specified and as directed. 51 Removing of excavated material (soil) to distance exceeding 1.5Km and not exc. 5Km and deposited where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed. 52 Material and labour in repair for 150mm bore RCC pipes, class NP-2 laid and jointedwith collars and tested including demolition and breaking up 150mm bore dia drain pipes(salt glazed earthern ware,AC or reinforced concrete), set in cement mortar complete all as specified and as directed. 53 Material and labour in repair for 200mm bore RCC pipes, class NP-2 laid and jointedwith collars and tested including demolition and breaking up 200mm bore dia drain pipes(salt glazed earthern ware,AC or reinforced concrete), set in cement mortar complete all as specified and as directed. 54 Material and labour in repair for 300mm bore RCC pipes, class NP-2 laid and jointedwith collars and tested including demolition and breaking up 300mm bore dia drain pipes(salt glazed earthern ware,AC or reinforced concrete), set in cement mortar complete all as specified and as directed. 55 Material and labour for PCC (1:3:6) type C2 ( using 40mm graded broken stone aggregates) as in bed to drain pipes includingpacking under and haunching against the sides of pipes after they are laid and testedfor 150mm bore of pipe including demolition of existing PCC complete all as specified and as directed. 56 Material and labour for PCC (1:3:6) type C2 ( using 40mm graded broken stone aggregates) as in bed to drain pipes includingpacking under and haunching against the sides of pipes after they are laid and testedfor 200mm bore of pipe including demolition of existing PCC complete all as specified and as directed. 57 Material and labour for PCC (1:3:6) type C2 ( using 40mm graded broken stone aggregates) as in bed to drain pipes includingpacking under and haunching against the sides of pipes after they are laid and testedfor 300 mm bore of pipe including demolition of existing PCC complete all as specified and as directed. 58 Material and labour for PCC (1:2:4) type B1 (using 20mm graded broken stone aggregates) as in surface channel and drain including demolition of existing concrete complete all as specified and as directed. 59 Material and labour for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC (1:2:4) type B-1, smooth finished and reforming benching as required for 200 mm internal dia of pipe complete all as specified and as directed. 60 Material and labour for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC (1:2:4) type B-1, smooth finished and reforming benching as required for 300 mm internal dia of pipe complete all as specified and as directed. 61 Supply and fix Precast RCC manhole cover include frame, 50mm thick light duty factory made with IS code-12592:2002 specification and fixed properly over manhole on new/old and set in CM 1:4 and handles including demolition of existing RCC cover (reinforcement cut as required to facilitate demolition) of any description and in any position complete all as specified and as directed. 62 M&L for pre-cast cement concrete block masonry with solid blocks exc10 cm in width, type C-1,1:3:6 (using 20mm graded stone aggregate) and setting in cement mortar 1:6 including demolition of existing complete all as directed 63 Supply and fix in repair PVC (SWR) pipe 75mm bore single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed. 64 Supply and fix in repair PVC (SWR) pipe 110mm bore single socketedin any length with rubber ring joints laid intrenches or in floors complete all as specified and as directed. 65 Supply and fix in repair PVC (SWR) pipe 110mm bore single socketed in any length with rubber ring joints fixed to wallscomplete all as specified and as directed. 66 Supply and fix in repair PVC (SWR) bends any radius of 75mm bore complete all as specified and as directed. 67 Supply and fix in repair PVC (SWR) bends any radius of 110mm bore complete all as specified and as directed. 68 M&L Demolition and breaking up 150mm dia drain pipes (salt glazed, stone ware, AC or reinforced concrete) set in cement mortar complete all as directed. 69 -- ditto-- as per Sl Item No 68 but of 200mm dia 70 -- ditto-- as per Sl Item No 68 but of 300mm dia 71 M&L for PCC type D-2,1:4:8 (using 40mm graded stone agg) as in foundations,filling and mass concrete including demolition of existing complete all as directed 72 Material and labour for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC (1:2:4) type B-1, smooth finished and reforming benching as required for 150 mm internal dia of pipe complete all as specified and as directed. 73 Material and labour for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC (1:2:4) type B-1, smooth finished and reforming benching as required for 200 mm internal dia of pipe complete all as specified and as directed. 74 Material and labour for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC (1:2:4) type B-1, smooth finished and reforming benching as required for 300 mm internal dia of pipe complete all as specified and as directed. 75 Material and labour in repair for 150mm bore RCC pipes, class NP2 laid and jointedwith collars and tested, set in cement mortar complete all as specified and as directed. 76 Material and labour in repair for 200mm bore RCC pipes, class NP2 laid and jointedwith collars and tested, set in cement mortar complete all as specified and as directed. 77 Material and labour in repair for 300mm bore RCC pipes, class NP2 laid and jointedwith collars and tested, set in cement mortar complete all as specified and as directed. 78 Material and labour for brickwork with fly ash old size bricksbricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:6) including demolition of existing complete all as specified and directed. 79 Material and labour for Cement concrete (1:2:4) type B-1 (using 20 mm graded broken stone aggregate) as in coping, benching, bed blocks, lintels upto 1.5m clear span and the like including including weathering, slightly rounded or chamfered angles and throating, using necessary form workincluding demolition of existing concrete all as specified and as directed. 80 Material and labour for rendering 15mm thick in cement mortar (1:4)on fair faces of brick or concrete surfaces mixed with liquid water proofing as per manufacturers instructionwith, finished even and smooth without using extra cement complete all as specified and as directed. (Note: Supply only liquid waterproofing will be measured and paid separately). 81 Material labour for RCC (1:1½:3) type A-1 (nominal mix), (using 20mm graded broken stone aggregates) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, septic tank slab, shelves and the like including demolition of existing RCC complete all as specified and as directed. 82 Material and labour for formwork to soffits and edges of suspended slabs such as roof slabs, floor slabs, landings, cover slab of septic tank and similar work not exc. 200 mm thickfor fair finished flat surfaces of concrete all as specified and as directed. 83 Material and labour for mild steelTMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) notless than 0.9mm dia or securing with clips complete all as specified and as directed. 84 Supply and fix Precast RCC manhole cover include frame, 50mm thick light duty factory made with IS code-12592:2002 specification and fixed properly over manhole on new/old and set in CM 1:4 and handles including demolition of existing RCC cover (reinforcement cut as required to facilitate demolition) of any description and in any position complete all as specified and as directed. 85 Taking out semi solid, liquid suspension sludge and foreign material from man hole/ septic tanks/ soakage well of any description and any depth including sucking/ pumping of water by honey sucker with pump set and removing and refixing of acessories and appliances required for safe disposal of sludge and foreign materials either by carrying the same in covered van or trolley at out side MOD land and burring the same (semi solid/ liquid shall not be burried) in ground complete all as directed. (Note: The location at out side MOD land for disposal of foreign material obtained above shall be located by the contractor himself). Note: (i) Measurement shall be actual plane area X 1/2 total depth of septic tank/Man holes (ii) Complete solid, liquid & sludge shall be removed . 86 Cleaning/clearing & Maintanance of sewage lines including CI/PVC/SGSW/RCC stacks, incl under ground sewage lines any depth by removing any type of blockage from sewage drain exceeding 200mm and not exceeding 300mm bore/ dia by rodding or any other means from manholes to manholes including plugging of manholes temporarily as and when required and flushing with water after cleaning including intermediate manholes. Sludge/sludge water in form of semi solid/loose state will be disposed off either by carrying the same in covered van or trolley at out side MOD land and burring the same (semi solid/ liquid shall not be burried) including taking off manhole covers and refixing the same after cleaning. The operation shall be executed/carried out with any kind of sewage cleaning device such as sewage cleaning Mechanical Pump / Vehical and cost of same shall be deemed to be included in the rate quoted by the contractor. 87 Supply and fix in repair for PVC (SWR) pipe 75mm bore single socketedin any length with rubber ring joints fixed to wallscomplete all as specified and as directed. 88 Supply and fix in repair for PVC (SWR) pipe 110mm bore single socketed in any length with rubber ring joints fixed to wallscomplete all as specified and as directed. 89 Supply and fix in repair for PVC (SWR) branch piece, single Y, equal or unequal/ Tee for 75mm bore pipe complete all as specified and as directed. 90 Supply and fix in repair for PVC (SWR) vent cowl for 110 mm bore pipe complete all as specified and as directed. 91 Material and labour 75mm thick PCC (1:3:6) type C2 (using 40mm graded broken stone aggregate) as in plinth protection/court yard finishing the surface even and smooth without using extra cement including demolition of existing complete all as specified and as directed. 92 M&L Machine pressed rubber moulded glossy finish precast concrete interlocking paver block any shape and size confirming to IS- 15658-2006 of 60 mm thk, M35 gde in floor/ pavment laid over and including 30mm thick crushed sand cushioning laid dry to the profile including vibrating with surface vibrator after laying of tiles complete all as specified and as directed. 93 - ditto- as per item no 92 but except Paver Blocks 94 Removing of vegetation/plantation on the wall/ roof/ in any position (area of vegetation including in each job upto 1.00 sqm ) , up to 15.0 Mtr building height including necessary scaffolding and roots girth n. exc. 10cm eachand applying chemical treatment with GLYPHOSATE 41% as per manufacturing instructions and making good surface to match with existing including removing /refixing of CI/GI pipe lines complete all as specified and as directed. 95 Material and labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty PVC concealed conduit including all accessories, Metal flush box of suitable module, with earth dolly, covered with twin colour (specified by Engr-in- Charge)modular white cover plate & frame after chasing in stone masonry walls etc for accomodating modular switches, sockets, regulators etc including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly, providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixtures all as specified and as directed for the following 96 One light / wall / exhaust fan pointcontrolled by one, one way switch 6 Amps complete all as specified and as directed 97 One5 pin socket outlet plug point, 6 Amps, controlledby one, switchon same board complete all as specified and as directed 98 One5 pin socket outlet plug point, 6 Amps, controlledby one, switchon independent board complete all as specified and as directed 99 Description all as per 95 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 6 pin socket outlet plug point,16 Amps independentincluding necessary running of 2.5 Sqmm PVC insulatedmultistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dollyproviding Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixturesall as specified and as directed 100 Supply and fixingModular Switch - 6 Amps, Single pole one way, one module complete all as specified andas directed. 101 Supply and fixingModular Switch - 16 Amps, Single pole one way, one module complete all as specified andas directed. 102 S & FModular socket outlet multipurpose 6 Amps, 5 pin, 2 module, complete all as specified andas directed. 103 S & FModular socket outlet multipurpose 16 Amps, 6 pin-shuttered type, 2 module, complete all as specified andas directed. 104 S & F Ceiling rose, 3 phase / PVC / polycarbonate,complete all as specified andas directed 105 Supply and fixing20/22 WattInverter LED Battenaluminium body with Opal Diffuser, IP20, Battery back-up & Functioning as per Product TDS with intregrated electronic driver, connector block, holder, decorative end caps, LED tube light etc complete with all accessories prewired and mounting PVC rectangular block, including provision of flexible copper conductor cable of suitable size from ceiling rose to connector and taking down old unserviceable fitting from existing postion for carrying to store, making good disturbed surfaces complete all as specified and as directed.Make Halonix Cat No LED INVERTER BATTEN HLB-08-22-CW-INV or equivalent in Havells, LHEXACP7FNIW020 106 Supply and fixingLED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lampconnecting up with three core flexible copper conductor cable of suitable size from ceiling rose to connector, making good disturbed surfaces complete all as specified and as directed.Make Jaquar cat No -LGLZ01X010XW , Orient Cat No- LBLN-10-C-SQ 107 S & F for plastic body exhaust fan, AC single phase, 240 V of size 250 mm sweep with louvers (as per Cat Part No -698502of Make Indo Asian or equivalent Make-Bajaj Maxima DX/ Usha Crispair )including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and as directed 108 Taking down carefully existing unserviceable main switch /cutout /DBs of any type, capacity and description and removing materials from site and making good disturbed surfaces of walls, floors as per the existing finishes all as specified and as directed. 109 S & F sheet metal enclosure MCB DB SPN 8 waywith 100 Amps rated bus bar 240 Volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface to match the existing colour of wall complete all as specified and as directed 110 S & F for sheet metal enclosure MCBDBSPN4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. Make - Schneider/Legrand/L&T/ABB. 111 Supply and fixing amp rating 240V, 10KA C curve miniature circuit breaker (MCB)SP 5 To 32 AMPand current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed 112 Supply and fixing amp rating 240V, 10KA C curve miniature circuit breaker (MCB)SPN32 AMPand current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed 113 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. 114 Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed. 115 M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with multistranded copper conductor of size 4.0 Sq mm nominal area and drawn through PVC non metallic rigid PVC casing caping as per site requirement and its accessories including one run ofPVC insulated 4.0 Sq mm (nominal area) multistranded copper conductor FRLSH cable as earth wire and connected from DB to DB/ main board complete all as specified and as directed. 116 Supply and fix electric water heater,storage type Inner container material Steel with Glass and having 2 Nos Heating element type of Incoloy with Glass coated heating element upto2 KW capacity 70 litre, 230 Volts 50 Hz , temp range 35 to 75 C, with 7 Years on Tank,4 Years on Heating Element and 2 Years on Other Parts, with Outer body material of ABS, PUF insulation,lined BEE 5 Star, with product dimension of 470x470x371mmrated complete with all accessoriessuch as safety valve, thermostate,NRV, connection piece etc vertical type all as specified and directed by Engr-in-Charge. (Make Versa Vertical Manual 70 Ltr of Jaquar or equivalent in Havells/Bajaj/Recold/Haier/Orient/Hindware) 117 Supply and fixing of geyser Bolt120mm Long with nut & washers, complete all as specified and directed 118 Note : 1. Performance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site.