Tender For Provision Of 05 X Attached Bathroom And Toilet In Jcos Accommodation P-214 At 311 Fd Hosp; 1 Excavation in trenches n./exc. 1.5m wide and n/exc. 1.5m in depth for foundation etc., for shafts walls, cesspits manholes pier holes etc. n/exc 10 Sqm on plan and n/exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. 2 Removing excavated material exceeding 250 mtr but not exceeding 500 mtr and depositing where directed at alevel 1.5 m above the starting point complete all as specified and directed. 3 Retrurning filling in soft/loose soil including spreading leveling watering and wall ramming in layers n/exc. 25 cm thick all as specified and directed. 4 M&L for brick work with FLY ASHbricks built in CM (1:6) straight orcurved on plan & exc 6 m mean radius with old size bricks complete all as specified and directed. 5 M & L 40 mm thick damp proof course in cement concrete 1:2:4, TypeB-0 to horizontal or vertical surfaces including water proof compound and necessary form work complete all as specified and directed. 6 M&L PCC (1:4:8) type D-2 (using 40mm graded stone agg.) of in foundation sub base complete all as specified and directed. 7 Sand filling under floors or in foundations including watering and consolidation all as specified. 8 M&l for hardcore of guage n. exc63mm, deposited, spread& leveled in layers n exc. 15 cm thick, watered & rammed to a true surface complete all as specified and directed. 9 M&L plain cement concrete type B1 ( 1:2:4) using 20 mm graded stone aggregate as in lintels upto 1.5m clear span, cills,steps; seismic and other similar band, copings, bed plates, and like including weathering slightly rounded or chamfered angles and throating, as directed complete, including necessary formworkcomplete all as specified. 10 M & L 75mm thick plain cement concrete type D-2 1:4:8 (40 mm graded stone aggregate) as in sub base complete all as specified and directed. 11 M & L Non Skid ceramic colouredtiles 7mm to 8mm thick, (square or rectangular) area of each tile exc 0.06 Sqm but n. exc 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over incl screed bed or beeding layers of mortar 15mm thick in CM 1:6 in floors, complete all as specified and directed. 12 M&L for Glazed ceramic coloured tiles in vertical surface 450 x 350 x 7mmthick set and jointd in neat cement slurry and pointed in whie or coloured cement to match pigment over and including 10mm thick CM (1:4) backing coat Tiles shall be of grade B-III as per IS-13712 (1993) of First quality all as specified & directed 13 Cuttingopenings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings, converting window into door openings, etc. or cutting out defective brickwork for under pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hardcore , etc., to store and disposed of rubbish not exc. 50 m complete all as specified and directed. 14 M&L Forming jambs, etc. to openings (to foregoing item),including cutting, toothingand properly bonding into old work, also facing, jointing and pointing to match existing work, completecomplete all as specified and directed. 15 M&L Making good under cills or over arches, Lintels and bressummers, including all-pinning when necessary new brick work built in Cement mortar 1:4 complete all as specified and directed. 16 M & L 15mm thick plastering in cement mortar 1:3 mixed with and includin approved water proofing compound on RCC roof surfaces. 17 M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces of block masonary or concretesurfaces in 1:6 finished even and fair . 18 M & L 5 mm thick rendering cement plaster on brickwork or concrete surfaces in cement mortar 1:3 on ceiling , finishing the surfaces even and fair complete all as specified and directed. 19 M&L PCC type C-1Mix 1:3:6 (20mm graded stone aggregate), 50mm thick in plinth protection/path finishing the surface even and smooth without using extra cement with joints filled with bitumen grade 85/ 25 and sand in equal proportionsby weight complete all as specified and directed. 20 M&L for brick work with FLY ASHbricks built in CM (1:4) straight orcurved on plan to any radius in half brick thick walls with old size bricks. 21 S&F solid PVC door, cup boardframe size 50mmx47mm made out of 5mm prelaminated PVC sheetreinforced with MS square tube all as per specification and as per drawing shown on ser page No 150 of SSR Part II (for item 884) complete all as specified and directed and directed 22 S&F factory made solid PVC door, cup board shutter30mm thick (Style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded both side prelaminated PVC C channel having a prelaminated PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & b PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail, lock rail & bottom rail panelling of both side prelaminated PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading & jointed together with solvent cement, supply & fixing in the frame at site as per SSR specification & diagram/product drawing shown on ser page No 156 of SSR Part II complete all as specified and directed & directed 23 S&F 125mm size aluminium handles cast type, anodized all as spd and directed 24 S&F aluminium anodised barrel tower bolt of extruded section 150mm length of bolt all as specified & directed 25 S&F Mildsteel butt hinges medium weight 100mm long complete all as specified and directed. 26 M&L for Powder coatedaluminium ventilator having frame of Section 57x52 ,Series -B 20535 andshutters, without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminiumsnap beading, screws, anodised aluminium fittings such as peg stays150mm long (1 no.).complete all as specifiedcomplete all as specified and as directed. . 27 M&L RCC 1:2:4(nominal mix )as in Slabs supported on walls, beams and columns in floors, roofs, landings,balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. 28 Use and waste of formwork to soffits of suspended slabs rough finish surface of concretesuch as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) all as directed 29 M & L TMT bars 10mm dia and over cut to length bent to shape required in spacers and binders including cranking bending spirally for hoping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and directed. 30 M&L TMT 8mm dia and over upto including 10mm dia in stirrups spacers and binders cut to length bend to shape required including mild steel wire(annealed) not less than 0.9 mm dia all as specified and directed. 31 M & L white washing three coats on ceiling surfaces including preparation of newly plastered untreated surfacesceilingcomplete all as specified and directed. 32 M&L for prepararion of new plsatered surface of wall andtwo coat ofcement base paint over a coat of primer complete all as specified and directed. 33 S&F Bib taps 15mm bore cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed. 34 S & Fin repairs stop valves, cast copper aloy screwed down high pressure fancy type CP, screwed both ends for 15mm dia bore GI tubing. 35 S & F Rotational moulded polythelene water storage tank 500 Ltr (Cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed. 36 S & F Cast iron floor trap 75 mm dia, with gratingincluding jointing to waste pipe in cement concrete type B1 (1:2:4) complete all as specified and directed. 37 S & F 20mm Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density ball screwed for iron pipe and fixed complete all as specified and directed. 38 S & F 15mm bore stop valves (concealed type), cast copper alloy screwed down high pressure , with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed. 39 S&F Steel water tubing, medium grade, galvanised with & including all tube fittings & fixed / consealed in walls and ceiling or laid in floors including testing complete of 15 mm bore complete all as specified and directed. 40 S&F Steel water tubing, medium grade, galvanised with & including all tube fittings & fixed / consealed in walls and ceiling or laid in floors including testing complete of 20 mm bore complete all as specified and directed. 41 S&F 600x450mm beveled edge mirror of selected sty glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden pluges with chromium plated brass screws and cup washers complete all as specified and directed. 42 S&Fvitreous china wash down water closet pan (pedestral pattern), white including connection trap and to flushing pipe, anti-syphnoge pipe, seat coveretc complete including complete all as specified and directed. 43 supply only PVC seat cover for pedestal pan, white closed pattern with flat bottom and cover and mild steel chromium plated or aluminiumisedhanging device complete all as directed. 44 S &F Vitreous china wash hand basin white flat back 550 x 400 mm with pedestal of standard size including chromium plated brass waste coupling, waste pipe, vulcanite plug with ring, pillar taps, PVC connection of suitable length, brackets and cutting for & pinning in ends of brackets etc complete all as specified and directed. 45 S&F 10 ltrs capacity PVC valve less, syphonic action type flusing cistern, low level white with inlet ball valve float and handle including brackets fixed complete all as specified and directed 46 S&F PVC connection 600mm long of dia 15mm complete all as specified and directed. 47 S&F 20 mm Towel rail chromium plated 600 mm long complete all as specified and directed. 48 S&F in repairHealth faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect complete all as specified and directed. 49 S&F 75 mm PVC (SWR) pipes double socketed,inanylength with rubber ring joints, laid in trenches or in floors complete all as specified and directed. 50 S&F 75 mm PVC (SWR) pipes doublesocketed inany length withrubber ring joints fixed to walls complete all as specified and directed. 51 S&F 110 mm PVC (SWR) pipes doublesocketed inany length withrubber ring joints fixed to walls complete all as specified and directed. 52 S&F 75 mmPVC (SWR)bendsany radius complete all as specified and directed. 53 S&F 110 mmPVC (SWR)bendsany radius complete all as specified and directed. 54 M&L for water proofing treatment to non accessible RCC roofs by providing 10mm thick screed in CM 1:3 mixed with & including water proofing compound @ 3% by weight of cement & applying one coat of bituminous primer @ 0.30 kg/sqm & laying APP based polymer modified membrane with polyster non woven reinforced of weight not less than 3 kg/sqm 3mm thick with polythene finished sealing with side over laps of 75mm& 100mm laps at the ends of membrane by torch application method & applying two coats of aluminium paint asper the makes approved by the Engr-in-Charge. 55 M&L for concrete bed for 150 mm bore pipe in PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) to drain pipes including packing under, haunching against the sides of pipes after they are laid and tested complete all as specified and directed. 56 M&L for 150 mm bore SGSW drain pipe (Grade-A) laid in trenches and jointed in CM 1:1 and tested complete all as specified and directed. 57 Cutting into exisiting manhole for connecting new drains, making good to pipe rendering, cutting out exisitng benching for and forming branch channel (1/2 round or 3/4 section ) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required. 58 Surface excavation n.exc 30cm deep & averaging 15cm deep & getting out in soft loose soil. 59 M & L for providing PCC 1:4:8 type D-2 (40mm graded agg) 100 mm thick ,as in sub base to floors. 60 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. 61 M & L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Gradecomplete all as specified and directed. 62 M&L for point wiring with 1100 volts grade PVC insulated FR-LS multistranded copper conductor cable 1.5 sqmm (Phase - R Y B, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm diaISI marked with all conduit fittings / fixing accessories and sunken galvanized pressed modular steel terminal boxes of thickness not less than 1.2 mm covered with suitable and required size of modular box, plate with cover for mounting modular switches, sockets, fan regulators complete including making good the wall surfaces with matching colour on wall for the following 63 One light point controlled by one switch. 64 One ceiling/ex fan point controlled by one switch. 65 One socket outlet 6 amp controlled by one switch on the same board with other switches. 66 One socket outlet 6 amp controlled by one switch on indepdendent board. 67 M&L for Point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm diaISI marked with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm covered with suitable and required size of modular box for one 16 amp socket outlet controlled by one switch on independent board complete all as specified and directed. 68 S&F modular switch one way 6 amp 1 module all as specified and directed 69 S&F modular switch one way 16 amp 1 module all as specified and directed 70 S&F modular socket6/16 - 2/3 pin combined 2 moduleall as specified and directed 71 S&F modular socket 6 amp 3 pinall as specified and directed 72 S&F Ceiling rose 6 amp, 3 plates polycarbonate body complete all as specified and directed. 73 S&F LED batten (20W) made of PVC housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 120+ lumens per watt and total power consumption not less than 20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.90complete all as specified and directed. 74 Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 75 S&F MCB distribution board SPN, 240 volts, 4 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required. 76 M&L for submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green)drawing into andincluding concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories of following nominal sizes:- 77 2x6 sqmm + 1x6 sqmm earth continuity conductor in 20 mm dia conduit.. 78 S&F air ventilation fan 250 mm in toilet in rectangular in shape, PVC body, white colour 230V including louber shutter complete all as specified and directed. 79 Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc 80 S&F MCBs as per load requirementC series of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:- 81 Single pole 6 to 32 amp. 82 Double pole 32 amp. 83 Cutting existing steel tubing for alterations or aditions of pipe size 40/50 mm bore and screwing complete all as specified and directed. 84 Supply and fix Valve, globe conforming to IS 9338, 50mm (2”) dia pipe complete all as specified and directed. 85 S&F 20 mm dia,Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed fancy type chromium plated complete all as specified and directed.