Tender For Certain B/R And E/M Works In Domestic Area At Af Stn Gwalior.; 1 Excavating in trenches in soft /Loose Soil n exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed. 2 M& L for PCC 1:4:8 Type D2 (40 mm graded agg) in foundations, filling, mass concrete and sub base of floor complete all as specified and directed. 3 Sand filling under floor including watering and consolidation complete all as specified and directed. 4 Earth filling under floor obtained from excavation spreading and levelling in layers n exc. 25 cm thick, well ramming including watering as required. 5 M& L for 25 mm thick PCC type B-0, 1:2:4 (12.5mm graded aggregate) as in flooring sub base and similar work complete all as specified directed 6 M&L for Treating the bottom and sides of excavation at the rate of 5 litres of anti termite emulsion per square metre of surface area complete all as specified and directed. 7 M&L forTreatment of soil under existing floors using anti termite emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floorscomplete all as specified and directed. 8 M&L forTreating the soil along with external perimeter of building at the rate of 2.25 litre of anti termite emulsion per metre of the perimeter wall complete all as specified and directed. 9 Returning, filling in soft/Loose soil, including spreading, levelling, watering and well ramming in layers not exc 25 cmcomplete all as specified and directed. 10 Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. 11 M& L forBrickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m meanradius built in Cement mortar 1:6 complete all as specified and directed. 12 Taking down cement plaster including on brick or stone wall etc incl racking out joints hacking for key & scrubbing down with water etc.complete all as specified and directed. 13 M & L for rendering 15 mm thick onbrick or concrete surface of wall in CM 1:6 other than fair faces and surface finished even and smooth without using extra cement complete all as specified and directed.Note:-Cost of scaffolding for rendering shall be included in quoted rate. 14 M & L for rendering 10 mm thick onbrick or concrete surface of wall in CM 1:4and surface finished even and smooth without using extra cementcomplete all as specified and directed. Note:-Cost of scaffolding for rendering shall be included in quoted rate. 15 M&L for 5mm thick renderingin CM 1:3 finished even and smooth without using extra cement as in ceilings complete all as specified and directed. 16 M& L for Hard core, broken stone/bouldersto gauge n exc 63 mm thick complete all as specified and directed. 17 M&L for 75mm thk PCC (1:3:6) type C-1(20mm graded stone aggt) as in Plinth protection, surface finished even & fair using extra cement complete all as specified and directed. 18 M&L 75mm thick PCC 1:4:8 type D2 (using 40mm graded stone agg) as in subbase of floor complete all as specified and directed. 19 M& L for reinforced cement concrete Nominal Mix type B1 1:2:4 ( 20 mm graded aggregate) as in Foundations, including rafts, footings, foundation beams ,plinth beams , bases for columns, etc., basement slabs, under-reamed piles and mass concrete complete all as specified and directed 20 M& L for re-inforced cement concrete nominal mix type B1 1:2:4 ( 20 mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. 21 M& L for re-inforced cement concrete type B1 1:2:4 ( 20 mm graded aggregate)as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. 22 All as per item No 20but as inChajjas and similar work complete all as specified and directed. 23 M& L for re-inforced cement concrete type Nominal Mix B1 1:2:4 ( 20 mm graded aggregate)as in Columns,pillars,piers,posts and struts complete all as specified and directed. 24 M&L forFormwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter fair finished surface complete all as specified and directed 25 M&L forFormwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)and fair finished complete all as specified and directed 26 M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc and fair finished complete all as specified and directed 27 M& L for Formwork to sides of pillars, posts, struts, piers,columns and stanchions Square rectangular on plan complete all as specified and directed 28 S&FMild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping forcolumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips (Fe-410-W 432 (Part I) (Gde.E-250)complete all as specified and directed 29 All as per item No27 abovebut 6mm to 8mm dia TMT bar as in stirrups complete all as specified and directed 30 M&L for Complete removal of existing treatment on walls (any number of layers) by scrapping with mechanical wall sander(having mechanical vaccum mechanism) to make the surface free from dust, loose paint etc by skilled labour andfilling the cracks and depressions with putty/ chalk whitening to make the surface even and smooth matching to the adjacent wall surfaces and applying two coats water based premium acrylic smooth exterior emulsion of approved colourdiluted with water as per manufacturer instructions applied with fully automatic airless spray machine Allow 6-8 Hrs to dry the surface in the both the coats of paint over a coat ofprimer diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application complete all as specified and directed. 31 M&L for Complete removal of existing treatment on walls (any number of layers) by scrapping with mechanical wall sander(having mechanical vaccum mechanism) and applying a coat ofwaterproof cement based putty and sanding of the putty surface with mechanical wall sander (having mechanical vaccum mechanism) and applying two coats Oil bound distemper using airless spray technology complete all as specified and directed. 32 M&L for Preparation of newly plaster surface of ceilng andapplying two coats of distemper oil emulsion as specifiedand directed. 33 M&L for Preparation of newly plastered surface andapplying two coat of weather coat exterior emulsion white or tintedby the using rollers over a coat ofprimer as approved complete all as specifiedand directed. 34 M&L for Preparation of newly plastered surface andapplying two coat of distemper oil emulsion white or tintedby the use of rollers over a coat of chalk whitening primer (preparatory to distempering) over and including a coat of putty 1 mm thickas approved complete all as specifiedand directed. 35 Taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m with shutters (without taking off shutters from the frame) eachand removing to store complete all as specified and directed. 36 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed 37 M&L for non skid ceramictiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6, complete all as specified and as directed. 38 M&L for glazed ceramic tiles (coloured) 450x350 x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10 mm thick renderingin cement & sand mortar 1:4, complete all as specified and as directed. 39 M& L forVirified Ceramic light shade tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6. Complete all as specified and directed 40 All as per item No38 above but for vertical surfaces of walland skiriting including 10 mm thick screed bed in CM 1:4, complete all as specified and directed. 41 S& F Powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified 42 S& FPowder coated Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and directed. 43 S& Fpowder coated Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and directed. 44 M& L for 5.50mmSheet glass, ordinary quality fixed inAluminium window/door/ventilatorshutter complete all as specified and directed. 45 S&F in galvanized mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanized wire staples etc. in wooden or aluminium door / window and Steel door / window complete all as specified and directed. 46 M& L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like , set & jointed in cement mortar (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 20 mm screed bed in cement mortar 1:4 for horizontal surfacescomplete all as specified and directed. 47 Taking up 100 mm cast iron water mains (including all fittings), with spigot and socket ends and lead joints including burning out jointscomplete all as specified and directed. 48 Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to storecomplete all as specified and directed. 49 Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to storecomplete all as specified and directed. 50 S& F 15 mm boremedium grade galvanised steel tubing laid in trenches including all fittingscomplete all as specified and directed. 51 S& F 20 mm boremedium grade galvanised steel tubing laid in trenches including all fittingscomplete all as specified and directed. 52 Taking down chowkat or frame with shutters area not exc 1.5 Sqm each (without taking off the shutters from the door/window frame)/ventilator including iron mongrey andcutting holes for hold fasts & making good complete all as specified & directed. 53 S & F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS Square tube complete all as specified and directed. 54 S&F Factory Made Solid PVC Moulded Door Shutter with wood free EPS, 28 to 30mm thick(stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. 55 S&F butt hinges of size 100mm medium weight, stainless steel ISI marked complete all as specified. 56 S&F 150 mm size aluminium alloy handles, fabricated type,extruded section etc completeall as specified and directed. 57 S&F 150mm longaluminium anodised barrel tower boltsof extruded section complete all as specified and directed. 58 S&F Aluminium anodised , sliding door bolt with hasp , staples (bolt type) and fixing clipsof sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed 250 mm long complete all as specified and directed. 59 M&L double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass other parts made of mild steel heavy duty and fixed complete all as specified and directed. 60 S&F 110 mm PVC (SWR) pipes single socketed,inanylength with rubber ring joints, laid in trenches or in floors incl taking down of old pipes of any type complete all as specified and directed 61 S& F in repair 110 mm PVC (SWR)bendsany radius complete all as specified and directed 62 S&F 110in repair PVC (SWR) vent cowl complete all as specified and directed 63 S & F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed. 64 S&F in repair PVC valveless symphonic action type low level flushing cistern (ISI marked) of 10 litre capacity including32 mm dia PVC flush pipeconnected to water closet with inlet, ball valve, float and handle complete all as specified. 65 S&F in repair Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed 66 S&F Urinal spreader of Brass CP any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed. 67 S&F in repairVitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed 68 S&F in repair vitreous china counter top wash hand basin, white/coloured, flat back, size 560 x 455mm excluding taps, waste pipe & PTMT waste coupling of 32 mm dia complete all as specified and directed. 69 S&F PVC connection of 15mm bore, 450 mm long with brass coupling on both ends of superior quality complete all as specified and directed. 70 S&F 32 mm Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections includingnecessary packing, union and cap and fixed complete all as specified and directed. 71 S&F in repair PVC(SWR) floor trap/nahani trap including grating suitable for 110mm bore pipe complete all as specified and directed. 72 Dismantling PVC water tanks and removing for capacity exceeding 250 litres & not exceeding 500 litres etc complete all as specified and directed. 73 S&F 1000 Litre capacity Rotational moulded polyethylene water storage tanks (cylindrical, vertical with closed top) hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc complete all as specified and directed. 74 S&F in repairbrass CP tubular towel rail of superior quality 20mm dia 60cm long between flanges fancy type complete all as specified and directed. 75 S&F in repair CP soap dish fancy type etc fixed on wall surfaces etccomplete all as specified and directed. 76 S&F in repairs PTMT waste pipe 32 mm bore of length up to 80 cm for WHB / sink/unrinal pots, complete all as specified and directed. 77 S&F, in repair, 15mm dia long body bib taps, cast copper alloy chromium plated fancy type with crutch or butterfly handle sc-rewed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. 78 S&F in repair CP angle valve for 15 mm bore pipe with capstan head long screwed shank including cp cover plate fancy type complete all as specified and directed. 79 S&F in repair 20 mm dia gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. 80 S&F in repair Health faucetmild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. 81 S&F in repair pillar tap 15mm dia long body,chromium plated, fancy type complete all as specified & directed. 82 M&L for preparation of new surfaces of steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of red oxide complete all as specified and directed. 83 DismantlingWallandceilingboards(fibre, pulp, insulation, etc.) or insulationboards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. 84 S&F 15-16mm thickness acoustic mineral fibre micro perforated finish (Reveal type/rectangular edge) ceiling board of600x600mm size fixed over and including pre powder coated GI frame with suspension system (Grid) comprising of T section 25mmx32.5mmx1.6mm size as main runners and wall angle to placed along the wall at desired level of the False ceiling 4mm dia GI suspender of suitable size and dash fastners to be provided at desired distance and making good the dismantling portion complete all as specified and directed. 85 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and directed. 86 Removing excavated materialexc. 1.5 KM and not exc 5 KM above the starting point and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. 87 M&L60mm thick rubber moulded glosy finished inter locking paver block with grey cement and pigment of any type and shape the minium compressive strength not less than 350 kg/sqcm as approved complete all as specified and directed.Note : Sand filling under interlocking paver block shall be measured & paid seprately. 88 M& L for providing reinforced cement concrete Type B-0 (1:2:4) (using 12.5 mm graded stone agg) as inin lintels upto1.5m clear span,cills,steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bedplates complete all as specified and directed. 89 Demolition of brick work or stone boulders masonry built in cement mortor or cement lime mortor including all quoins arches pillars etc., but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed. 90 M&L for stone walling of random rubble masonry uncourse, well bonded, bedded and solidly hearted built in CM (1:6)complete all as specified and directed. 91 Demolition cementConcrete in ground floors and pavings n exc 15 cm thickness (below or above ground level complete all as specified and directed. 92 M&L for PCC (1:2:4) type B-1, (using 20 mm graded stone aggregate) as in surface channel etc complete all as specifiedmade to shape and size complete all as specified and directed. 93 M & L for PCC (1:2:4) type B0, using 12.5mm graded stone aggregate as in coping including necessary form work complete all as specified and directed. 94 M& L for providing precast reinforced cement concrete Type B1 (1:2:4) (using 20 mm graded aggregate) as in cover slabs chullah hoods,chajjas, water troughs, mangers, shelves and similar articles with plain face set in cement mortar 1:4 landings complete all as specified and directed. 95 M& L for 15 mm thick rendering on brick work /concrete surface in cement mortar 1:4finished even and smooth with out using extra cement complete all as specified and directed. 96 M&L forProvidig plain cement concrete type B1 (1:2:4) in window or door cills,lintels, bressumers,steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks,ancho-rage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated),set in cement mortar 1:6 with plain fair faces, includingchamfers, weatherings, throat- ing etc. and setting in mortar complete all as specified and directed. 97 BLANK 98 M& L forBrickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m meanradius built in Cement mortar 1:6using old retrieved bricks obtained from demolition in serviceable conditions complete all as specified and directed. 99 M&L for preparation of newly plaster surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and directed. 100 Taking down carefully existing unserviceable copper/ aluminium point wiring of any description & in any position with and includingpvc/steel conduit all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings call bell, lamp holders etc and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed. NOTE: Old fittings/fixtures/accessories like switch, sockets, lamp holders, regulators light fittings etc found in serviceable condition shall be removed carefully for reuse in the work and shall be paid for separately under appropriate item of Schedule `A’ complete all as specified & directed. 101 Material and labour for point wiring for one light /fan/Exhaust fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including surface PVC conduits (Medium grade) of size not less than 20 mm dia all as directed with sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with laminated top sheet of 3 mm thick for housing of switches, sockets, regulators etc including all accessories andusing 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. NOTE :-(i)Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A.(ii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thicklaminated sheet fixed with suitable brass screws and cup washers 102 Description same as per Srl item No 100 above but,point wiring for 5 pin switch socket outlet combination, 5/6 Amps on independent boardwith using 2.5 Sqmm (nominal area) stranded copper conductor and2.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. 103 Description same as per Srl item No 100above but,point wiring for one six pin switch socket outlet combination, 15 Amps & 5 Amp (independent) with using 2.5 Sqmm (nominal area) stranded copper conductor and2.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. 104 Note for Item serNo 100:- (a)ForLights points : one circuit shall have maximum 08 points. Note for Item serNo 101 & 102 :-(a)For Socket outlet Ind6 Amps ( One circuit with maximum 4 points).(b)For Socket outlet 16 Amps ( One circuit of one point only) 105 M & L forswitch flush type single pole one way 5 Amps, 240 volts, white ivory finish complete all as specified & directed. 106 S&F switchsocket combination multi purpose, 5 Pin 6 amps, flush typeWith Indicator complete all as specified & directed. 107 S&F switchsocket combination multi purpose, 6 Pin 6/16 amps, flush typeWith Indicator complete all as specified and directed. 108 M&L for ceiling rose surface Bakelite three terminal, 18 x 50 mm complete all as specified & directed. 109 Supply & Fixing in repair surface mounted type LUMILINE PLUS NEO light fittings complete 1x20 watt (4 ft), 6500K, Average life 50000 hrs LED lightning fixture with extruded aluminium housing integrated electronic driver complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor PVC sheathed cable suitable size etc complete all as specified and directed.Make:- Havells cat part No. LUMILINEPLUSNEOBS20WLED830SPCSSINDS or Wipro cat part No Wipro Garnet 20w Aluminium Led Batten or cat part No. BTI-WHT-LGLZ01XO20XC of JAQUAR. 110 M&L for 36W LED6500K recess softline luminaire OCTANE PLUS LED 2X2 PANEL suitable for armstrong/grid ceiling with high brightness LEDsgiving glare free light and good aesthetic appel. Fixture size 583x583 mm complete with LED tube with driver and all accessories complete all as specified & directed. 111 Supply and fixing Aircirculating fan wall mounted, AC, single phase, 230 V, of size 400 mm sweep and connecting up including provision of cable from ceiling rose/ connector to fan complete all as specified & directed. 112 Supply and fixing Street/Security light fittings 1X35W new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED as light source with acrylic cover suitable for pole dia O 40mm(Max) including connecting with 3 core PVC sheathed wire necessary connection etc complete (40 mm GI pipe light grade ),clamp,nut-bolt and washers complete all as specified & directed. 113 Dismaintling & Taking out MCB DBs VTPNany size , any type and capacity complete all as specified & directed. 114 Supply and fixing of sheet metal enclosure Double door for DB’s 8 way 240 volts with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wirescomplete all as specified and directed. 115 Supply and fixing factory made epoxy powder coated distribution board TP & N 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one TPN-MCCB 125 Amps as incomer and 12 SP MCBs(or any combination of SP/TP MCBs )outgoings incl taking out VTPN MCB DB complete all as specified & directed. 116 Dismaintling & Taking outMCBs/isolator of any size , any type and capacity complete all as specified & directed. 117 S&F MCB single pole 6 to 32 Amps, B series10 KA ,240 Volts complete all as specified & directed. 118 S&F MCB Single pole and neutral 40 to 63 Amps, B Series240 Volts complete all as specified & directed. 119 Supplying & fixing MCCB, 3 pole, 125 Amps, 50Hz, 415 Volts with rupturing capacity 16 KA with thermal magnetic release and adjustable overload setting having type DPX 160 fixed in distribution board complete all as specified & directed. 120 Disconnecting& taking up or down unserviceable sub main wiring of aluminium/Copper conductor with two run of single core cable and one run of single core earth cable of any description, any size & in any position including taking out existing conduits of any description and making good the disturbed surfaces to the existing surfaces complete all as specified and directed.(NOTE:Two run of single core PVC cable with one run of earth conductor shall be measured as one unit.) 121 M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6.0 Sqmm of voltage rating upto and including 1100 Volts grade in and including conceled PVC conduit, med grade of size not less then 25 mm bore along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductorof size 6.00 Sqmm as earth continuity conductor all as specified and directed.(NOTE :(i) Two run of single core PVC cable with one run ofearth conductor and conduit shall be measured as one unit.) (ii) The quoted rates shall be deemed to be inclusive for cutting chasesin wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface complete all as specified & directed. 122 M&L for single pole and neutral enclosure with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB of capacity 20 Amps, 240 Volts complete fixed on wall by provisioning of suitable sizes of MS strips, nuts, bolts and washers taking down of AC boxall as required and directed. 123 M&L for earthing complete with MS Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level)with top edge of plate not less than 1.5 mtr below normal ground level including necessary excavation, earth work ,charcoal, salt etc and connected to GI earthing lead wire 4 mm dia by means of GI bolt nuts check nuts washers etc and 20 mm dia GI light grade watering pipe with funnel, wire mesh etc including PCC (1:3:6) type C-1 using 20 mm graded stone aggregate earth pit with 40x40x6 mm mild steel angle iron frame, RCC cover (1:2:4) type B-0, 50 mm thick reinforced with 8 mm dia round bar @100 mm centre to centre both ways with mild steel handle 12 mm dia, plastering 12 mm thick in cement mortar (1:6) internally and upto 150 mm below ground level externally, and GI earth lead wire 4 mm dia and 15 mm dia GI protection pipe medium grade from earth plate to test point upto 7.5m length all as shown in electrical plate No 3 of SSR Part -I 2009 and connected to earth test point including testing completeall as specified& directed. 124 Excavation in trenches in soft/loose soilnot exceeding 1.5 m deep and not exceeding 1.5 mtr wide and getting out including forming bottom surface to required levels/gradients/slopesfor foundations/laying of cable etc. all as specified and directed including taking out existing cable protection brick cover etc completeall as specified& directed. 125 M& L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. 126 M&L bricks for coverunderground cable with one layer of bricks using sub class B bricks (Old size) laid flat across the cable complete all as specified. (Excavation and earth work will be measured separately). 127 Supply, Laying ,jointing & testing35 sqmm 3.5 core LT cable 1100 Volts grade, stranded aluminum conductor, screened, XLPE insulated, armoured heavy duty laid in trenches /ducts ,floor fixed to wall etc complete all as specified and directed. 128 Supply & Fix steel Tube medium grade galvanised of dia 50 mm for road crossing of cable and on pole and DB cable as in cable protection complete all as specified and directed. 129 Excavation in trenches in soft/loose soilexceeding 1.5 m deep and not exceeding 1.5 mtr wide and getting out including forming bottom surface to requiredfor foundations of pole etc all as specified and directed . 130 Supply and fix steel tubular swaged poles type 410 SP-55 (11 meter long) complete with CI base plate and finial taper plug, bolts nuts and screws all as specified and directed. 131 Supply and fixing of LED floodlight 100 W made up of pressure die cast aluminum housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. System efficacy 110 LPW all as specified and direcetd. 132 M& L for Cement concrete inmass concrete filling type D-2 1:3:6 (40 mm graded) complete all as specified & directed. 133 M & L for Pre cast cement concretemasonryin motor complete Type B1 1:2:4(20 mm graded) for coping complete all as specified & directed. 134 Supply , laying , connecting and testing LT 1100 volt grade electric cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured (heavy duty) ISI marked with aluminium stranded conductor gross sectional area 16 Sqmm , 4 core laid in trenches / duct / pipe etc complete all as specified and directed . 135 Supply , laying , connecting and testing LT 1100 volt grade electric cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured (heavy duty) ISI marked with aluminium stranded conductor gross sectional area 10 Sqmm , 2 core laid in trenches / duct / pipe etc complete all as specified and directed . 136 Supply and fixing, connecting and testing the outdoorLED Post Top garden light fittings,Fully Cast Aluminium body finished with Polyurethane Paint (With Prior Treatments) with acrylic window cover.Total LENGTH 900 mm (36 Inches) & Max. BREADTH 360 mm(14.4 Inches). B22 Brass Holder provided with Aluminium cover. Spigot Entry: 78 mm.As Per: IS 10322 PART-5 SECTION-1 LATEST 2017. SUITABLE FOR: 30 to 40 W LED BULB complete all as specified & directed. Make- MEPRO cat part No PTL-0008 or equivalent in Bajaj/Crompton/Havells. 137 Supply and fixing Cast aluminum heavy pole designer leg and broader designer base fwith plate 422 mm x 422 mm finishedwith polyurethane paint (with prior treatments). The diameter of one leg at middleis approx 88 mm. and diameter of one leg at edges is approx 100 mm outer dia for spigot entry 75mm , 03 Nos. T shaped bolts with nuts and washers provided for concrete foundation. The total length of the pole including base and legs (base and legs ( base with plate x 4 Nos legs) is 3055 MM ( Appx 10 Feet 0.2 Inches complete all as specified & directed. Make -MEPROcat part No MCPL-04or equivalent in Bajaj /Crompton /Havells. 138 Supply and fixing of LEDspike light of 10 watt suitable for outdoor environment with iP 65 that beautify transforms the beauty of your space all as specified and direcetd. Make : Cat part No- LHEVACPBPN6K010 ofHavellsor OSK-BLK-LSPK05R112XW of Jaquar or 581953 10W Philips black garden spike NW of Philips. 139 Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 25x4 mm (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire meshincluding necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover 1 : 2 : 4 ,type B-1( using 20 mm graded crushed stone aggregare ) reinforced with8 mm dia TMT bars @ 75 mm c/c both ways with 12mm dia round bar as in handle including taking down of existing earthing completeall as specified & directed. Note: (i) Test result of earthing to be submitted by the contractor for all earthing . (ii) Earth filling shall be done by vegetable soil. (iii) Soil should be free from stone, boulders,aggragates,gravel etc.(iv) The rate quoted by the bidders shall be also be deemed to include :-(a) Supply of charcoal and common salt. 140 Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified & directed. 141 Supply, install, testing and commission of LT Panel outdoor type IP-54 protection as per IS-2147 CPRI Approvedsuitable for AC supply 3 phase 4 wire, 415 V, 50 Hz having dust and vermin proof MS sheet with suitable appropriate size complete painting , PCC etc comprising of controlling MCCB/ACB supported on F class DMC/FRP insulator with short circuit withstand capacity 21 MVA for 1 second, the fixing of the doors shall be such that the doors should automatically come to closed position and the following accessories all as specified and directed(a) Bus bar Aluminium suitable Amp with colour code suitable for 4 wire system (Red, Yellow, Blue and Black)|(b) Voltmeter 0-500 with three phase selector switch -01 Nos|(c) Ammeter suitable Amps with CTs of suitable size and three phase selector switch-01 Nos(d) Phase indicating lamps -03 NosIn coming:-1. MCCB - 63 Amps, 415V, 4 Pole, AC with thermal setting 70% to 100% and 36 KA-01 No.Out going :-1. MCCB - 40 Amps, 3 Pole, AC with thermal setting 70% to 100% and 25 KA-02 Nos.2. Spare place for fixing any switch gear in future-01 No3. Including supply and fix inside of panel time swiches astro type (Having logitude and latitude of Indian cities in memory) 415V three phase of 20 Amp rating with cotactor fitted inside steel enclosure.Make : Shalabh (India) Industries Roorkee, Indo Asian , Power System & Control Jalandhar, Rew Construction Pvt Ltd.