Tender For Provn Of Solid Waste Management At Varanasi Cantt.; 1 Supply , installation, testing & Commisioningofpre fabricated Bio gass plant of capacity 50 kg/day complete all as specified and directed. 2 Supply, installation, testing & Commisioningofpre fabricated organic waste composting matchine of capacity 50 kg/day complete all as specified and directed. 3 Supply, installation, testing & Commisioningofpre fabricated organic waste shredder machine 50 Kg/Hr complete all as specified and directed. 4 Surface excavation, n.exc 30 cm deep and averaging 15 cm deep and getting outin soft / loose soil complete all as specified and directed. 5 Excavating in post holes (or similar holes), each n exc 0.5 cum in soft/ loose soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed. 6 M&L for Plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. 7 M&L for structural steel work using mild steel rolled section confirming to Fe 410 - W Gde-E-250 quality A,as in main and cross beam, hip and jack rafters,purlins, where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connected plates, complete all as specified and directed. 8 M&L for mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe 410-W (Gde-E-250) complete all as specified and directed. 9 M&L for applying two coat of synthetic enamel paint over a coat of red oxide primeron new steel surface of any description over 10cm in width or girth includingpreparation of surface, completeall as specified and directed. 10 S&F0.5 mm thick pre-painted galvalume aluminiumzinc coating GI based corrugated steel sheetof any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws, completeall as specified and directed. 11 S&F 0.50mm thick pre-painted galvalume aluminum zinc coating GI based Plain steel sheetof any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws completeall as specified and directed. 12 M&L for Brick work with subclass B old size bricks, straight or curved on plan exc 6 m mean radius built in CM (1:6) completeall as specified and directed. 13 M&L for hardcore using broken stones or boulders of gauge not exceeding 63mm, deposited, spred and levelled in layer not exceeding 15cm thick, watered and rammed to true surface completeall as specified and directed. 14 M&L for 15 mm thick rendering on other than fair face of brick work or concrete surfaces of walls in cement mortar 1:4 mixed with liquid WPC @ 200ml/ 50kg cement/ oras per manufacturers instructions (which ever is more) completeall as specified and directed.Note:- WPC will be measured and paid seperatly under respective item here-in-under as supply only. 15 M&L for applying two coats of cement base paint on new plastered surfaces of walls including preparation of surfaces completeall as specified and directed. 16 M&L for three coat white washing on new plastered surface of walls including preparation of surface completeall as specified and directed. 17 Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 mtr depth for foundation etc or for column footings, manholes etc not exceeding 10 Sqm on plan and not exc 1.5 mtr in depthand getting out in soft/ loose soil complete all as specified and directed. 18 Removing excavated material (soil) at a distence exc. 250m but n exc. 500m and depositing where directed complete all as specified and directed. 19 M&L for Plain cement concrete 1:4:8 type D-2 (using 40mm gradedstone aggregate) in foundation, filling and mass concrete,complete all as specified and directed. 20 Returning, filling in,soft/ loose soil including spreading, levelling, watering and well ramming in layers n.exc.25 cm complete all as specified and directed. 21 M&LforFormwork to flat sides of concrete foundations, footing , bases of columns, raft and raft beams , sides and soffits if any of foundation and plinth beams and similar work, rough finished surfaces of concrete, complete all as specified and directed. 22 M&L for Reinforcemtn cement concrete (RCC) design mix, M-25 grade(using 20mm grades stone agregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 23 M&L for mild steel TMT bars of grade Fe-550,10mm dia and over, cut to length, bent to shape required including craking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 24 All as per item No. 23 above butTMT bars, 5mm dia and over up to and including 10mm dia in stirrups and spacers. 25 Supply only liquid water proofing compound completeall as specified and directed. Note :- WPC mixed with cement mortar under item No. 14 here-in-before shall only be measured and paid. 26 M&L for 75 mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth protection, finishingsurface even and smooth without using extra cement completeall as specified and directed. 27 M&Lfor 100 mm thick plain cement concrete 1:3:6type C-2(using 40mm graded stone aggregate) as in sub base of floors completeall as specified and directed. 28 M&L for 40 mm thick plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in floors, finished even and smoothusing extra cement completeall as specified and directed. 29 M&L forproviding38 mm wideGlass dividing strips, 3 mm thick, inserted in position, conform to design in concrete floor completeall as specified and directed. 30 M&L for plain cement concrete 1:2:4Type B-1(using 20 mm graded stone aggregate) as in roof kerbs, mud stops, rounded or chamfered on edges completeall as specified and directed. 31 M&L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing completeall as specified and directed. 32 M&L for0.80 mm thickMild steelplain, black sheet, in hearths, covering to door shutters covering, covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc, and similar work, cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as requiredcut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. completeall as specified and directed. 33 M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in coping andin lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, completeall as specified and directed. 34 M&L for 25mm bore Galvanized steel water tubes, medium grade, ISI markedwith all fittings laid in trenches or roof/wall completeall as specified and directed.Note : Excavation and earth work shall be measured and paid separately under respective item here-in bfore. 35 All as per item No.34 above but20mm bore tubing. 36 S&F 20mm bore Gun metal globe or gate valves with iron wheel head (ISI marked) screwed both ends completeall as specified and directed 37 S&F 100mm bore cast iron PN 1.6 flanged sluice valve,with raising stam, completeall as specified and directed 38 M&L for Cutting /tapping 25/40/50mm bore GI pipe from main CI/DI/GI pipe line (any dia) including necessaty jointing/sealing material completeall as specified and directed 39 M&L for sand cushioning in trenches for cable protection with coarse sand, laid dry with uniform thickness including consolidation complete all as specified and directed.Note : Punned thicknes shall me measured foe payment. 40 Supply & Laying well burnt brick, locally available best quality (sub class B bricks)in trences,perpendicular to UG Cable as protection complete all as specified and directed. 41 Supply & Layingheavy duty XLPE armurred alluminium cable of size 35 Sqmm 4 Core,PVC Insulated, sheathed , 1100 Volts grade including connection to the main switch/cut out MCB/MCCB with necessary lugs complete all as specified and directed. 42 All as peritem No 41 above but cable of size 16 Sqmm 4 core 43 All as peritem No41 above but cable of size 6 Sqmm 2 core 44 M&L for 50mm bore GI tubing, light grade as inin protection of cable at road crossing /hard standing/pole, fixed with clam as per site requirementcomplete all as specified and directed. 45 All as peritem No44 above but tubingof size 32mm bore. 46 M&L for boring holes horizontally under road (without damaging the road surface of any discription) suitable for 50mm dia pipe, using necessary T&P(minimum 1.0 mtr below the road surface) and laid GI pipe in position complete all as specified and as directed. Note: GI Pipe laid will be measured and paid separately under respective item here-in-before. 47 M&L for Earthing with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level), with top edge of earth plate shall not less than 1.5 mtrs below normal ground level, connected to GI earth lead wire 4 mm diaby means of bolts, nuts, check nuts and washersetc, including necessary earth work( excavation, removing and RFR of soil), 15mm bore light grade GIpipe for protection of earth lead wire,20mm boremedium gradeGI watering pipe with provison of funnel with wiremesh, PCC eartpit chember with RCC cover, connected to earthing test pointincluding testing on completion complete all as specified and shown in Electrical Plate No.3 of SSR Part I and as directed.Note: Earth resistence test shall be carried out and record threoff shall be kept by Engineer -in-charge. The contractor shall facilitate for such test and no extra clain on this account shall be admisible. 48 Supply,installation, testing & commisioning of factory made, outdoor type LT pedestal panel of size 1000mm x 1000mm x 150mm, cubical, double door, powder coated, fabricated with3.15mm thick MS sheet, front and back openable hing door with proper locking arrangement, dust and vermin proof, floor mounting type, IP-65 protection including 200Amps rated copper bus bar 3 phase 4 wire system and wiring with suitable copper wiring cable and suitable PCC foundation completeas per IS and comprising of following:-(a) INCOMING:-(i) MCCB 125 Amps, 35KA ,4Pole 415 Volt, with TMR fixed type - 01 No(ii) Digital Ammeter0 to 500 A with selector switch - 01 No(iii) Digital Voltmeter0-200 V CT ratio type with selector switch and 3 Nos CTs 100/5- 01 No(iv) Phase indicator lamp LED type RYB - 01 Set(b) OUTGOING:-(i) MCCB 63 Amps 25 KA,4Pole 415 Volt with TMR fixed type - 04 No(ii) MCB 40Amps SPN - 03 No Note:Note :-Cable gland shall be provided for all incomming and outgoing connections. . 49 Supply anderrection of steel tubular pole swaged type 410-SP 31(9.0m long pole)as per IS:2713 (part I to III) 1980 complete with cast iron base plate, pole cap, mild steel bolt, nuts and screws complete including necessary earth work( excavation, removing and RFR of soil), PCC in foundation and plinth block/collor, pole painting, writing pole letters or figures complete all as specified and directed.Note:- (i) Excavationfor pole foundation shall be 1.57m deep and 900mm x 600mm in Plan.(b) PCCin foundation shall be nominal mix in praportion1:4:8 type D-2 (using 20mm graded crushed stone aggregate) and up to GL.(ii) PCC for plinth block/collar shall be 500mm high and 450 mm dia above GL (around the pole) and nominal mix in praportion 1:3:6 type C-1 (using 20mm graded crushed stone aggregate).(iii) Pole to be painted externally with one coat of black bituminous paint (upto planting depth before embedding pole in PCC) and with two coat of aluminium paint over a coat of red oxide primer above plinth block /concrete collar after preparation of surface and providing 3 Nos 30cm wide bend with diffrent colour SE paint at an intervell of 30cm (starting from top of plinth block in alternate layer upto 1.5m height) . 50 Contd/...(iv) Letter or figures (Block Roman, Italic as Indian) shall be 5 cm in height(min) and writen with thick synthetic enamel paint of approved shade complete all as specified and directed.(f) Manufactures test certificate for pole shall be produced before execution work. 51 S&F LED street lightluminaires 60 watt with pressuredie cast aluminium housing with heat resistant toughned glass, IP66 protection complete including 1.2 mtr long bend to shape GI pipe of desired size for fixing of security light & service connection cable completeall as specified and directed. 52 S&F sheet metal enclosure (DB)VTPNtype for MCCB, double door 415 Volt with 200 amp rated bus bar complete all as specified and directed. 53 M&L for concealed point wiring for One light point controlled by one, one way switch 5 Amps with 1.5 Sq mm single coremultistranded, 1100 Volts copper conductor cable, FRLSH type, PVC insulated unsheathed, drawn through and including rigid 20mm dia high grade ISI marked PVC conduit and its accessories, PVC shunken boxes of suitable size, earth continuity conductor of same size and specification cable and connecting to the common earth dolly completeall as specified and directed. Note : (i) cutting cheses required shall be measured and paid seperatly. 54 All as peritem No 52 above but point wiringforOne 3 pin 5 Amps socket outlets point controlled by one switch on the same board with 2.5Sqmm wiring cable 55 All as peritem No 52 above but point wiringforOne 3 pin 5 Amps socket outlets point controlled by one switch on the independentwith 2.5Sqmm wiring cable 56 All as peritem No 52 above but point wiringforOne 3/5 pin 15 Amps socket outlets point controlled by one switch on the independentwith 2.5 Sqmm wiring cable 57 S&F switch piano flush type (white)single pole one way 5 Amp, 230 Volts complete all as specified and directed. 58 S&F socket outlet3/5 pin, 5 Amps (white) complete all as specified and directed. 59 S&F switch-socket combination 2 in 1, 3/5 pin (white), 5/15 Amp flush type universal complete all as specified and directed. 60 S&F ceilling rose three terminal surface bakelite type AC 50 Hz 230 Volt of size 65x50mm (white) complete all as specified and directed. 61 S&F wall mounted batten type LEDlight fitting (T-8), 18 watts 230 volts with extruded aluminium heat sink for efficient heat dissipation and intregrated electronic driverconnector block etc complete with all accessories, internally pre wired and necessary mounting arrangements including 01 Ultra bright LED polycarbonate (T8) tube, 3 core multistranded copper conductor cable of size 23/0.193 for connecting fitting to ceiling rose complete all as specified and directed. 62 S&F sheet metal enclosure (DB), double door SPN, 8 ways with200 amps rated bus barcomplete all as specified and directed. 63 S&F 6 To 32 Amp MCB single pole(SP) 240 VoltB curve, breaking capacity 10 KAISI marked complete all as specified and directed. 64 S&F 40Amp MCB single pole and nutral (SPN) 240 VoltB curve, breaking capacity 10 KAISI marked complete all as specified and directed. 65 Cutting chases, pinning in Brick walls, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.