}

Tender For Procurement Of Certified Reference Materials(Crm) For Calibrating Petroleum Testing Instruments- 43 Items, manali-Tamil Nadu

Chennai Petroleum Corporation Limited has published Tender For Procurement Of Certified Reference Materials(Crm) For Calibrating Petroleum Testing Instruments- 43 Items. Submission Date for this Tender is 04-09-2025. Laboratory Equipment Tenders in manali Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

50857445
Tender For Procurement Of Certified Reference Materials(Crm) For Calibrating Petroleum Testing Instruments- 43 Items
Tender
Indian
Tamil Nadu
Manali
04-09-2025

Tender Details

Procurement Of Certified Reference Materials(Crm) For Calibrating Petroleum Testing Instruments- 43 Items , 8883100712-Crm For Distillation - Atf/Kero, Method: D86/Ip123 , 8883103102-Crm For Flash Point (Abel) – Atf/Kero, Method: Ip 170 , 8864910523-Crm For Freezing Point, Method: D7153 , 8883100872-Crm For Aromatics By Fia, Method: D1319 , 8864910863-Crm For Smoke Point, Method: D1322 , 9142030772-Crm For Kinematic Viscosity @ -20°C, Method: D7042 , 8883100292-Crm For Acid Number, Method: D3242 , 8883100032-Crm For Mercaptans, Method: D3227 , 8883100302-Crm For Colour-Atf/Kero Method: D156 , 8883100042-Crm For Density-Atf/Kero Method: D4052 , 8883101152-Crm For Density-Diesel Method: D4052 , 8883101002-Crm For Distillation-Diesel Method: D86/Ip123 , 8864910403-Crm For Flash Point (Abel) -Diesel, Method: Ip 170 , 8864910423-Crm For Flash Point (Pmcc) – Diesel, Method: D93 , 8883100052-Crm For Cloud Point Method: D2500 , 8864910543-Crm For Cfpp, Method: D6371 , 8864910503-Crm For Pour Point-Diesel Method: D97/Ip15/D6749 , 9142030762-Crm For Kinematic Viscosity@40°C-Diesel Method: D7042 , 8883100072-Crm For Water Content By Kf Method: D1744/Ip438/En Iso 12937 , 8883100082-Crm For Density-Fuel Oil Method: D1298/Ip160 , 8883100102-Crm For Pour Point-Fuel Oil Method: D97/D6749 , 8883100092-Crm For Kinematic Viscosity@50°C-Fuel Oil Method: D445/Ip71 , 8883100112-Crm For Kinematic Viscosity@100°C-Fuel Oil Method: D445/Ip71 , 9108390604-Crm For Micro Carbon Residue Method: D4530/Ip398/Iso10370 , 8883100122-Crm For Flash Point Method: D93 , 8883100132-Crm For Kinematic Viscosity@40°C-Lube Oil Method: D445/Ip71 , 8883100142-Crm For Kinematic Viscosity@100°C-Lube Oil Method: D445/Ip71 , 8883100612-Crm For Pour Point-Lube Oil Method: D97/D6749 , 8883103502-Crm For Flash Point-Lube Oil Method: D93 , 8883100152-Crm For Density – Lube Oil Method: D4052 , 8883100162-Crm For Colour – Lube Oil Method: D1500 , 8883100192-Crm For Density-Motor Gasoline Method: D4052 , 8883100212-Crm For Distillation-Motor Gasoline, Method: D86 , 8883100222-Crm For Aromatics In Gasoline Method: D6730 , 8845140504-Crm For Vapour Pressure Method: D5191 , 8883100252-Crm For Kinematic Viscosity@135°C-Bitumen Method: Is 1206 P:3 , 8883100262-Crm For Flash Point (Coc)-Bitumen Method: D92 , 8864910803-Crm For Softening Point Method: Is 1206 , 8899957471 Crm For Sulphur In Rfo Matrix Method: D4294. Vendor Should Supply Sulphur Calibration Standards In Fuel Oil Matrix As Per Concentrations Mentioned. Required Qty: 1 Set 1 Set Means: 6 Nos Of Standards Having 100 Ml Each. 0.20% 100Ml 1.00% 100Ml 2.00% 100Ml 3.00% 100Ml 4.00% 100Ml 5.00% 100Ml , 8883105432 Crm For Sulphur In Kerosene Matrix, Method: D4294. Vendor Should Supply Sulphur Calibration Standards In Diesel Matrix As Per Concentrations Mentioned. Required Qty: 1 Set 1 Set Means: 7 Nos Of Standards Having 100 Ml Each. Blank 100Ml 100 Mg/Kg 100Ml 500 Mg/Kg 100Ml 1000 Mg/Kg 100Ml 2000 Mg/Kg 100Ml 2500 Mg/Kg 100Ml 3000 Mg/Kg 100Ml , 8883100272 Crm For Sulphur In Diesel Fuel Method: D5453 Vendor Should Supply Sulphur Calibration Standards In Diesel Matrix As Per Concentrations Mentioned. Required Qty: 1 Set 1 Set Means: 5 Nos Of Standards Having 100 Ml Each. 0 Mg/Kg100ml 2 Mg/Kg100ml 5 Mg/Kg100ml 8 Mg/Kg100ml 10 Mg/Kg 100Ml , 8883100282 Crm For Sulphur In Iso Octane Matrix, Method: D5453. Vendor Should Supply Sulphur Calibration Standards In Iso Octane Matrix As Per Concentrations Mentioned. Required Qty: 1 Set 1 Set Means: 6 Nos Of Standards Having 100 Ml Each. 0 Mg/Kg 100Ml 10 Mg/Kg100ml 50 Mg/Kg100ml 75 Mg/Kg100ml 100 Mg/Kg 100Ml 300 Mg/Kg 100Ml , 9104396111 Crm For Sulphur In Lube Oil Method: D4294. Vendor Should Supply Sulphur Calibration Standards In Lube/Mineral Oil Matrix As Per Concentrations Mentioned. Required Qty: 1 Set 1 Set Means: 8 Nos Of Standards Having 100 Ml Each. Blank 100Ml 0.05% 100Ml 0.20% 100Ml 1.00% 100Ml 2.00% 100Ml 3.00% 100Ml 4.00% 100Ml 5.00% 100Ml

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail