| 1 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc and getting out in hard/dense soil complete all as specified and as directed. |
| 2 | M&L for Plain Cement concrete 1:4:8 (type D2) (40mm graded aggregrade) in foundations, filling and mass concrete complete all as specified and directed. |
| 3 | M&L for brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete as specified and as directed. |
| 4 | Brick work with fly ash old size bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed. |
| 5 | M&L for rendering 5mm thick in CM 1:4 on brick/concretes fair surfaces and finished the surface even and smooth without using extra cement complete all as specified and directed. |
| 6 | M&L for rendering 15mm thick in CM 1:6 on brick/concretes fair surfaces and finished the surface even and smooth without using extra cement complete all as specified and directed. |
| 7 | M&L for rendering 15mm thick in CM 1:4 on external sufaces on other than fair faces of brick work or concrete surfaces mixed with @2% WPCby weight of cement. (WPC paid seperately) and finished the surface even and fair complete all as specified and directed. |
| 8 | SupplyonlyWPC.(IntegralWaterProofing Compound) complete all as specified & as directed.. |
| 9 | M&L for preparation of new wall plaster surfaces and applying two coats of distemper with oil emulsion white or tinted over 2 to 3mm thick wall care putty on wall complete all as specified. |
| 10 | M&L preparation of newly plastered surface and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 11 | Complete removal of existing treatment on surface of wall and applying 2 coats of oil bound distamper emulsion including a coat of alkali resistant primer over 3 mm thick wall care putty, complete all as specified and directed |
| 12 | M&L for complete removal of existing treatment on ceiling and applying three coat of white wash complete all as specified and directed |
| 13 | S & F Framed work as in steel gates such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc complete all as specified and directed |
| 14 | M & L for preparation of new steel surface over 10 cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer.complete all as specified and directed |
| 15 | Material and labour for preparation of new steel surface of any description n.exc 10cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide when unconnected with other painting or when painted in a different tint complete all as specified and directed |
| 16 | Returning, filling in, including spreading , levelling, watering and well ramming in layers not exc 25 cm as in Hard/dense soil.complete all as specified and directed |
| 17 | M&L for Reinforced cement Concrete (Nominal mix) type B1 1:2:4 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies deck slabs and in shelves and the like complete all as specified and directed. |
| 18 | M&L for RCC (Nominal Mix) type B1 1:2:4(using 20mm graded stone aggregate) as inChajjasand finished conctrete surface flat complete all as specified and directed. |
| 19 | M&L for Reinforced cement Concrete (Nominal mix) type B1 1:2:4 (using 20mm graded stone aggregate) as in roof beams ,floor beam, lintel beam etc and finished conctrete surface flat complete all as specified and directed. |
| 20 | M&L for Formwork to soffits of suspended slabs such as landings and similar work; not exceeding 200mm thick rough finished surface of flat concrete(Horizontal or sloping) complete all as specified and directed. |
| 21 | M&L for Formwork to edges of concrete flats, treads, breaks in floors and roofs n exc 20cm wide and similar work etc complete all as specified and directed. |
| 22 | M&L for Formwork to chullah hoods, chajjas, troughs and similar itemsincl edges complete all as specified rough finished flat surfaces of complete all as specified and directed. |
| 23 | M&L for Formwork to sides and soffits of floor or roof beams, Landing beams etc. rough finished flat concrete surfaces complete all as specified and directed. |
| 24 | M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed. |
| 25 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed |
| 26 | M&L for TMT bars 06 to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed. |
| 27 | M&L for granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over 15mm thick cement screed bed in CM 1:6 complete all as specified and directed. |
| 28 | M&L for 20mm thick granite (of any type) tilesmachine cut, in skirting/dado laid over 10mm thick cement screed in CM 1: 4 and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed. |
| 29 | M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as specified and directed. |
| 30 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 31 | M&Lhard core of broken stone of gauge exc 63mm deposited spread and levelled in layers n.exc 15 cm thick watered and rammed to a true surface etc complete all as directed. |
| 32 | M&L for150 mm thick plain cement concrete 1:4:8 Type D-2 (Using 40 mm graded stone aggregate) as in sub base and finishing surfaces of concrete topping even and rough to receive the topping layer completeall specified and directed. |
| 33 | M&L for 40mm thick plain cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in floor finished and finish cement concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 34 | S&F Glass dividing strips, 3mm thick and 38mm width inserted in position, conform to designcomplete all as specified and directed |
| 35 | Surface excavation not exc 30cm deep and getting out in hard dense soil complete all as specified and directed by Engr-in-Charge. |
| 36 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 37 | M& L forRubber moulding Machine presed precastinterlocking paver block of any size and shape confirming to IS 15658-2006 of 80mm thickM-40 GRADE with grewy cement and pigmentset over sand cushioning as directed and specified by Engineer in charge |
| 38 | Removing excavated material(soil)exc. 1.50 km but n.exc. 5.0 km and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed |
| 39 | Providing cement concrete type B1 1:2:4 (20mm graded aggregate) asincills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for , water troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed |
| 40 | Cutting holes in bricks wall built in cement mortar or cement lime mortar, RCC coloumns and stone wall exc 115mm but not exc 230mmcomplete all as specified and directed |
| 41 | M&L point wiring with 1.5 Sqmm (nominal Area), 650 /1100 Volts grade, PVC insulated FRLS multi stranded unsheathed copper conductor cable, in and including ERW rigid stove enamelled steel heavy duty conduit not less than 20mm dia, ISI marked with all flame proof conduit fittings, accessories and junction boxes as per site requirement for one light point/buzzer point controlled by one switch complete all as specified and directed. |
| 42 | M&L for flame proof weather proof rotary switch, single pole, on & off, with cable termination box in LM 6 of 16 Amps rating 250 volt complete all as specified and directed. |
| 43 | Supply and fixing FPWP LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.complete all as specified and directed. |
| 44 | M&Lfor flame proof weather proof distribution board,4 way duct and vermin proof IP-65, LM-6 body, appropriate size with epoxy powder coating, suitable for the following scheme :-(a) Incoming : MCB 32 Amps, DP, 10 KA, - 01 Nos, (b)Outgoing: (i) MCB,SP, 6/10 Amps, 10 KA - 02 Nos,(ii)Make of DB :Syaam or equivalent in Make Flexpro or Sudhir.complete all as specified and directed |
| 45 | Supply and fix FPWP exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep with, blades, and frame and louvers complete all as specified and directed |
| 46 | M&L FP weather Junction box entry size4 way junction box 100 mm Dia Make :shyam Cat part No: SSPL/JB/105 complete all as specified and directed |
| 47 | M&L for earthing complete with galvanized steel earth plate electrode of size60cm x 60cm x 6mm thick burried directly in ground vertically at a depth not less than 2.25 metredeep below normal ground level with top edge of the plate not lessthan1.5 metre below normal groundlevel surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using galvanized iron earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron or steel and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1: 2: 4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 3 of SSR Part I (2010)incl dismanteling of esisting unserviceable erth pitall as specified and directed by Engr-in-Charge. |