| 1 | Excavation over areas, n.exc 1.5m deep and getting out Hard/dense soil complete all as specified and as directed. |
| 2 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out hard/dense soil complete all as specified and as directed. |
| 3 | Removing excavated materilas (soil) exc 1.5 km but n.exc 5.00 KM and deposing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed. |
| 4 | M&L for 100 mm thick plain cement concrete 1:4:8 type D2 (Using 40mm graded stone aggregate) as in sub base and finishing surfaces of concrete topping even and rough to receive the topping layer complete all specified and directed. |
| 5 | M&L for PCC 1:2:4 type B-1 (20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in ite 4028, water trought andthe like including weathering, slightly rounded or chamfered angles and throating, as directed as required etc complete all specified and directed. |
| 6 | M&L for sand filling under floors or in fouondations including watering and consolidation complete all specified and directed. |
| 7 | M&L for 80 mm thickness M-40 Grade precast concrete interlocking paver block and pointed with grey cement and pigment and of approved size and shape and confirming to IS 15658-2006.complete all specified and as directed. |
| 8 | M&L for PCC 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in surface channel and drains complete all as specified and directed. |
| 9 | M&L for extra for forming fair finished drain or channel 30cm inner girth in cment concrete using extra cement including forms moulds mitered/stopped ends etc complete all as specified and directed |
| 10 | Framed work such as grills gratings, etc with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed alusters, walk ways, railings framework of water tanks and similar work conforming to Fe 290, Gde E-165 complete all as specified and directed |
| 11 | M&L for painting to new steel surfaces of any description over 10 cm width including preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed |
| 12 | Demolition of Cement Concrete of any description and in anypositionnot otherwise specifically provided for complete all as specified and directed. |
| 13 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises as specified. |
| 14 | Taking down chowkhat n. exc 1.50 sqm each with shutter (without taking of shutter from the frame) as specified. |
| 15 | Complete removal of existing treatment on surface of wall and applying 2 coats of oil bound distamper emulsion including a coat of alkali resistant primer over 1-2 mm thick wall care putty, complete all as specified and directed. |
| 16 | M&LPCC(1:4:8)typeD-2(using40mmgraded stone aggregate) as in foundations, filling and mass concrete all as specified and as directed. |
| 17 | M&L for brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete as specified and as directed. |
| 18 | M&L for rendering 15mm thick in CM 1:6 on brick/ concretes on fair surfaces and finished the surface even and smooth without using extra cement complete all as specified and directed. |
| 19 | M&LRendering15mmthickonfairfacesofbrick work or concrete surface in cement plaster 1:4 finishing the surface even & smooth without using extra cement & with WPC (WPC will be measured & paid seperately) complete all as specified & as directed. |
| 20 | SupplyonlyWPC.(IntegralWaterProofing Compound) complete all as specified & as directed. |
| 21 | M&L for preparation of newly plastered surfaces and finishing walls with Premium Acrylic Smooth exterior paint (any tint) with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) over new prepared surface complete all as specified and directed |
| 22 | M&L for preparing newly plastered surfaces of walls and applying 2 coats of oil bound distemper emulsion including a coat of alkali resistant primer over 3 mm wall care putty complete all as specified and directed. |
| 23 | M&L for preparing old plastered surfaces of ceilings and applying two coats of white washcomplete all as specified and directed |
| 24 | Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners,Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories Area not exceeding 2.00 sqm each complete all as specified and directed.(Note:The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.) |
| 25 | Supply and fixing factory made uPVC door frame made of uPVC . Extryded sections having an overall dimension (extruded section profile) 48x40 mm (tolerance + 1mm), with wall thickness 2.0mm (+ 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded.The hinge side vertical of the frames reinforced by galvanized M.S tube of size 19x19mm and 1mm (+ 0.1 mm) wall thicknes and 3 Nos. stainless steel hinges fixed to the frame complete all as specified by the manufacturer and as per direction. complete all as specified & as directed. |
| 26 | Providing and fixing factory made uPVC white colour casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with mitlti chamber, fram (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling ol holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm long fasteners.Hardware:[casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild sleel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) [and 5mm thick glazing with selected quality glass.complete all as specified & as directed.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose). |
| 27 | S&F 4.80 mmthick sheet glass ,ordinary quality, sheet galss is ground or obscured or frosted on one side, size of each pane exc 0.50 Sqmand fixed to door/window shutter and partition wall by means of glazing clips rubber strips etc complete all as specified & as directed. |
| 28 | S&F Galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanized wire staples complete all as specified and directed . |
| 29 | M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia or securing with clips.complete all as specified and directed . |
| 30 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia or securing with clips.complete all as specified and directed . |
| 31 | M&L for TMT bars 06 to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia or securing with clips.complete all as specified and directed . |
| 32 | M&L for reinforced cement concrete (nominal mix)1:2:4, Type- B1, (using 20mm graded crushed stone aggregate) as inbeams, cantilevers, bressumers, lintels over 1.5 m span etc.complete all as specified and as directed. |
| 33 | M&L for reinforced cement concrete (nominal mix) 1:2:4, Type- B1, (using 20mm graded crushed stone aggregate) as inChajjas complete all as specified and as directed. |
| 34 | M & L for reinforced cement concrete (nominal mix) 1:2:4, Type- B1, (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 35 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed. |
| 36 | Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed. |
| 37 | M & L for 75 mm thick cement concrete type D- 2, 1:4:8 (40mm graded aggregate) as in sub base to floor complete all as specified and directed. |
| 38 | M & L for 25 mm thick Cementconcrete type B-0, 1:2:4 (20mm graded aggregate) as in topping layer to receive the floor tiles complete all as specified and directed. |
| 39 | M & L for screed bed or bedding layer of mortar 15 mm thick for laying floor finishes etc in Cement Mortar 1:6 complete all as specified and directed. |
| 40 | M&L non skid ceramic tiles 7-8mm thick coloured (Square/rectangular) area of each tiles exceeding 0.18 sqm but n exc 0.36 sqmin floors set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed. |
| 41 | M&L for Cutting holes in brick walls exc half brick but not exc one brick built in cementmortar or cementlime mortar and stone walls built in lime mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed. |
| 42 | M & L for Granite 16-18 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. complete all as specified and directed. |
| 43 | Drilling and tapping cast iron water mains (in position) for branch connections of the 20 mm internal dia complete all as specified and directed |
| 44 | M&L Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified. |
| 45 | Supply and fixing tubes \"medium grade\" galvanised, 15 mm bore, ISI marked with all fitting such as bends, tees,elbows, unions,short pieces, connectors, back nuts etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed. |
| 46 | Supply and fixing tubes \"medium grade\" galvanised,20 mm bore, ISI marked with all fitting such as bends, tees,elbows, unions,short pieces, connectors, back nuts etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed. |
| 47 | S&FVitreous China, wash basin white, flat back , size 550mmx400 including brackets of any size, including cutting for and pinning in ends of brackets or erecting stand including fixing and supply of waste pipe of 32 mm dia, waste coupling of chromium plated brass.complete all as specified and as directed. |
| 48 | S & FPVC (SWR)Nahani trap 75 mm dia with grating including jointingwith solvent cement |
| 49 | Supply and fixing UPVC (SWR)type B pipes 75 mm bore single socketed in any length with rubber ringjoints, laid in trenches orin floors, complete all as specified and as directed. |
| 50 | Supply and fixing, UPVC (SWR) , bends for75 mm bore , complete all as specified and as directed. |
| 51 | S&F15mm bore angle valve with wall flange , cast copper alloy, chromium plated fancy type screwedfor 15 mm iron pipe, complete all as specified. |
| 52 | S&F 15mm bore brass CP basin mixer single lover for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 53 | S & F PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified. |
| 54 | M&L point wiring with 1.5 Sqmm (nominal Area), 650 /1100 Volts grade, PVC insulated FRLS multi stranded unsheathed copper conductor cable, in and including ERW rigid stove enamelled steel heavy duty conduit not less than 20mm dia, ISI marked with all flame proof conduit fittings, accessories and junction boxes as per site requirement for one light point/buzzer point controlled by one switch complete all as specified and directed. |
| 55 | M&L for flame proof weather proof rotary switch, single pole, on & off, with cable termination box in LM 6 of 16 Amps rating 250 volt complete all as specified and directed. |
| 56 | Supply and fixing FPWP LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.complete all as specified and directed. |
| 57 | M&Lfor flame proof weather proof distribution board,4 way duct and vermin proof IP-65, LM-6 body, appropriate size with epoxy powder coating, suitable for the following scheme :-(a) Incoming : MCB 32 Amps, DP, 10 KA, - 01 Nos, (b)Outgoing: (i) MCB,SP, 6/10 Amps, 10 KA - 02 Nos,(ii)Make of DB :Syaam or equivalent in Make Flexpro or Sudhir.complete all as specified and directed |
| 58 | Supply and fix FPWP exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep with, blades, and frame and louvers complete all as specified and directed |
| 59 | M&L FP weather Junction box entry size4 way junction box 100 mm Dia Make :shyam Cat part No: SSPL/JB/105 complete all as specified and directed |
| 60 | M&L for earthing complete with galvanized steel earth plate electrode of size60cm x 60cm x 6mm thick burried directly in ground vertically at a depth not less than 2.25 metredeep below normal ground level with top edge of the plate not lessthan1.5 metre below normal groundlevel surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using galvanized iron earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron or steel and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1: 2: 4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 3 of SSR Part I (2010)incl dismanteling of esisting unserviceable erth pitall as specified and directed by Engr-in-Charge. |