Tender For Replacement Of Lt Oh Lines To Ug Cables At Kota Mil Station; 1 Excavation in trenches not exc 1.5m wide and not exc 1.5m depth for laying of cables in and getting out hard/dense soil, complete all as specified and directed. 2 Description all as per Item No 1.00 above but for each additional 1.5 m or part thereof in depth beyond the first 1.5 m for soft/loose soil, complete all as specified and directed. 3 Returning & filling in including spreading, leveling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed. 4 Removing of surplus soil not exc 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed. 5 Supply and Spreading dry river sand for cable cushioning in trenches, complete all as specified and directed.Note : Punned down thickness i.e. 18 cm shall be considered for measurement purpose. . 6 Supply and laying burnt bricks sub class ‘B’ old size laid dry in trenches across the cable protection, complete all as specified and directed. 7 Supply and laying GI tubing, light grade, 80 mm bore as cable protection fixed on walls/poles/laid in trenches complete including dismantlingof old unserviceable pipe, complete all as specified and directed. 8 Supply and laying GI tubing, light grade, 50 mm bore as cable protection fixed on walls/poles/laid in trenches, complete all as specified and directed. 9 Supply and laying GI tubing, light grade, 40 mm bore as cable protection fixed on walls/poles/laid in trenches, complete all as specified and directed. 10 Supply and Laying ,including jointing, testing & commissioning LT under ground cable XLPE insulated screened, heavy duty with multi strandedaluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole etc ofsize 300 Sqmm 3.5 core, complete all as specified and directed. 11 Supply and Laying ,including jointing, testing & commissioning LT under ground cable XLPE insulated screened, heavy duty withmulti strandedaluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole etc ofsize 120 Sqmm 3.5 core, complete all as specified and directed. 12 Supply and Laying ,including jointing, testing & commissioning LT under ground cable XLPE insulated screened, heavy duty withmulti strandedaluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole etc ofsize 95 Sqmm 3.5 core, complete all as specified and directed. 13 Supply and Laying ,including jointing, testing & commissioning LT under ground cable XLPE insulated screened, heavy duty withmulti strandedaluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole etc ofsize 70 Sqmm 3.5 core, complete all as specified and directed. 14 Supply and Laying, including jointing, testing & commissioning LT under ground cable XLPE insulated screened, heavy duty withmulti strandedaluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole etc ofsize 50 Sqmm 3.5 core, complete all as specified and directed. 15 Supply and Laying, including jointing, testing & commissioning LT under ground cable XLPE insulated screened, heavy duty withmulti strandedaluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole etc ofsize 35 Sqmm 3.5 core, complete all as specified and directed. 16 Supply and Laying, including jointing, testing & commissioning LT under ground cable XLPE insulated screened, heavy duty withmulti strandedaluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole etc ofsize 25 Sqmm 4.0 core, complete all as specified and directed. 17 Supply and Laying, including jointing, testing & commissioning LT under ground cable XLPE insulated screened, heavy duty withmulti strandedaluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole etc ofsize16 Sqmm 4core, complete all as specified and directed. 18 Supply and Laying, including, jointing, testing & commissioning LT under ground cable XLPE insulated screened, heavy duty withmulti strandedaluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole etc ofsize10 Sqmm 4core, complete all as specified and directed. 19 Supply and Laying, including jointing, testing & commissioning LT under ground cable XLPE insulated screened, heavy duty withmulti strandedaluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole etc ofsize16 Sqmm 2core, complete all as specified and directed. 20 Supply and Laying, including jointing, testing & commissioning LT under ground cable XLPE insulated screened, heavy duty withmulti strandedaluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole etc ofsize10 Sqmm 2core, complete all as specified and directed. 21 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt, 3 core , drawn through LT steel tubular polesfor connection to street light from junction box, complete all as specified and directed. 22 Material and Labour for street light timer boards (Digital/Analoguetype) 32 Amps, 3 pole, 3 phase, suitable for out door operation, fixed in metallic housing complete with three phase contactor, relay, MCB TPN,etc and including taking down existing unserviceable street light timer, complete all as specified and directed. 23 M&L for Street light/ Road light mounting GI bracked made upto 25/32/40 mm dia (or size to suit the opening of the fitting) GI tubing light grade of minimum 1.5 mtr length bent to 120 degree shape & fixed to pole with 02 Nos mild steel flat iron clamps clamps (02 Nos) including GI nuts, bolts & washers suitable size bent to shape of 120 degree angle, complete all as specified and directed. 24 S&F in replacement terminal/Junction box made of thermoplastic Boxof size 205x255x112 mm, black in colour fixed on pole by means of mild steel clamps with bolt and nuts, provn for cable entry for incoming and outgoing including MCB 5-20 Amp-1 Nos and 4 way connector-1 Nos necessary connection duly fixed with and including cable glands threaded tye IP65 made of polymide with lock nut, complete all as specified and directed. 25 Taking down existing LED street light of any wattaage, placing it aside in a proper MES store and refixing it on poles complete all as specified and as directed. 26 S&F in replacement of old unsv PCC poles with new Steel tubular sewaged poles with cast iron base plate, taper plate, bolts, nuts and screws, as specified type 410 SP-31 9 Mtrs long, complete all as specified and directed.Note : (i) Cost of dismantling of old PCC pole & placing it aside 5 mtr nearby shall be included in the rate quoted. (ii)Earth work shall be measured & paid for separately under respective item of this Schedule. 27 M&L for painting of LT steel tubular poles 7.5 metre height above ground level, preparing surface for painting, applying two coat of aluminium paint upto full height of pole including MS clamps, cross arms, bracings along with Numbering of LT poles serially with letter/number size width and height up to 40 mm in situ with black paint on white back ground, complete all as specified and directed. 28 Material and labour for PCC 1:3:6, type C-2, using 40 mm graded stone aggregates as in foundation of poles, complete all as specified and directed. 29 M&L for PCC 1:2:4, type B-1, using 20 mm graded aggregate as in coping to the poles, complete all as specified and directed. 30 M&L in replacement Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground vertically to depth not less than 2.25m below ground level with top edge of earth plate not less than 1.5 Mtr below ground level connected to galvanized steel strip 25x4 mm dia by means bolts, nuts, washers, check nuts made out of galvanized iron and steel earth strip protected by GI pipe light grade 40mm dia connected to earth plate/test point all as shown in electrical plate No 3 SSR part-I including necessary earth work and PCC (1:3:6) type C-1earth chamber 40mm thick RCC 1:2:4 mix precastcover with 6mm dia normal reinforcement @ 100 mm centre to centre both ways etc, complete all as specified and directed.Note:- Material retrieved from old Earthing shall be deposited in E/M Store yard. 31 Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground vertically to depth not less than 2.25m below ground level with top edge of earth plate not less than 1.5 Mtr below ground level connected to galvanized steel strip 4 MM wire mm dia by means bolts, nuts, washers, check nuts made out of galvanized iron and steel earth strip protected by GI pipe light grade 40mm dia connected to earth plate/test point all as shown in electrical plate No 3 SSR part-I including necessary earth work and PCC (1:3:6) type C-1earth chamber 40mm thick RCC 1:2:4 mix precastcover with 6mm dia normal reinforcement @ 100 mm centre to centre both ways etc, complete all as specified and directed. 32 Dismantling of ACSRfrom the poles, complete all as specified and directed. 33 Dismantling of cross arms of MS channel or angle sections etc, complete all as specified and directed. 34 Dismantling insulators any type any size from LT poles, complete all as specified and directed. 35 Supply , installation testing and commissioning in replacement of old unsvout door type feeder pillar box any size & type factory made openable from front & rear double door type, dust and vermin proof, fabricated out of 3.15 mmthick, indoor compartment 2 mm thick CRCA sheet duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete with 4 Nos heat shrink insulated aluminium bus bar of 300 Amps rating includingall connection with aluminium busbar strip, feeder pillar box shall be provided with danger notice plate with skull & bone sign,making all electrical incoming and out going electrical cable connection with new lugs , glands to be provided at cable entries , including , MS channel frame of ISMC 75 at the base of panel only for grouting purposeand grouted in PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) complete all as specified and directed and comprising following accessories:-Incoming:-(a) MCCB four pole 415 Volts 50 Hz 160 Amps rating with rupturing capacity 25 KA adjustable thermal & adjustable megnetic settings -01 Nos.Out going:-(a) MCCB four pole 415 Volts breaking capacity 25 KA of rating 40 Amps mounted on din rail including connection from mainbus bar to MCCB with aluminium busbar strips of suitable current ratings- 06 Nos.(b) MCB TPN 32 Amps, 16 KA at 50 Hz 415 v- 01(c) Phase indicator lamp RYB complete with copper control wiring-01 set of three(d )AC Amp meter 0-500 amp with selector switch -01 Nos(e )AC Volt meter 0-500 Volts with selector switch -01 Nos 36 Supply , installation testing and commissioning of out door type LT Panel of suitable size factory made openable from front & rear double door type, dust and vermin proof, fabricated out of 3.15mmthick CRCA sheet, indoor compartment 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete with 4 Nos heat shrink insulated aluminium bus bar of 600 Amps rating includingall connection with aluminium busbar strip, feeder pillar box shall be provided with danger notice plate with skull & bone sign,making all electrical incoming and out going electrical cable connection with new lugs , glands to be provided at cable entries , including , MS channel frame of ISMC 75 at the base of panel only for grouting purposeand grouted in PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) complete all as specified and directed and comprising following accessories:-Incoming:-(a) MCCB four pole 415 Volts 50 Hz 400 Amps rating with rupturing capacity 36 KAadjustabletype-01 Nos.(b) Phase indicator lamp RYB complete with copper control wiring-01 set of three(c )AC Amp meter 0-500 amp with selector switch -01 Nos(d )AC Volt meter 0-500 Volts with selector switch -01 Nos(e )CT -03 NosOut going:-(a) MCCB four pole 415 Volts breaking capacity 160 Amps of36 KA - 02 Nos(b)MCCB four pole 415 Volts breaking capacity 40 Amps of36 KA - 06 Nos (c)MCB TPN 32 Amp- 01 No 37 Supply , installation testing and commissioning of out door type LT Panel of suitable size factory made openable from front & rear double door type, dust and vermin proof, fabricated out of 3.15mmthick, indoor compartment 2 mm thick CRCA sheet duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete with 4 Nos heat shrink insulated aluminium bus bar of 300 Amps rating includingall connection with aluminium busbar strip, feeder pillar box shall be provided with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connection with new lugs , glands to be provided at cable entries , including , MS channel frame of ISMC 75 at the base of panel only for grouting purposeand grouted in PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) complete all as specified and directed and comprising following accessories:-Incoming:-(a) MCCB four pole 415 Volts 50 Hz 160Amps rating with rupturing capacity36 KA microprocessor based adjustable-01 Nos.(b) Phase indicator lamp RYB complete with copper control wiring-01 set of three(c )AC Amp meter 0-500 amp with selector switch -01 Nos(d )AC Volt meter 0-500 Volts with selector switch -01 Nos(e )CT -03 NosOut going :- (a) MCCB four pole 415 Volts, 40 Amps of rupturing cap36 KA - 06 Nos(b)MCB TPN 32 Amp- 01 No 38 M&L for trenchless Boring under road / hard standing including making goodas per the exisitng, complete all as specified and directed.Note: Cost GI pipe shall be included in the rate quoted. 39 M&L for heat shrinkable type, outdoor type, cable end termination jointing Kits suitable for 1.1 KV XLPE/PVC Insulated for cables of 16 Sqmm 3.5 / 4 coresizes, complete all as specified and directed. 40 Description all as per Item No 39.00 above but for 25-50 Sqmm, complete all as specified and directed. 41 Description all as per Item No 39.00 above but for70-120 Sqmm, complete all as specified and directed. 42 Description all as per Item No 39.00 above but for 150-185 Sqmm, complete all as specified and directed. 43 M&L for heat shrinkable type, outdoor type, cable staright through jointing Kits suitable for 1.1 kV XLPE/PVC Insulated for cables of 16 Sqmm 3.5 / 4 core sizes, complete all as specified and directed. 44 Description all as per Item No 43.00 above but for 25-50 Sqmm, complete all as specified and directed. 45 Description all as per Item No 43.00 above but for 70-120 Sqmm, complete all as specified and directed. 46 Description all as per Item No 43.00 above but for 150-185 Sqmm, complete all as specified and directed. 47 Description all as per Item No 43.00 above but for 240-300 Sqmm, complete all as specified and directed.