Tender For Work Of Electrification Of Divisional Level Office Building In District Jalaun Orai - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C 2 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 3 Group C 4 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire 5 Wiring for light/ Power plug with 2X4 sq. mm FRLS PVC insuleted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1Nos. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthingas required. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 x 10 sq.mm. + 1 x 6 sq.mm. earth wire 6 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 x 16 sq.mm. + 2 x 6 sq.mm. earth wire 7 Supply and wiring of 4 numbers, 25 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 50 mm dia heavy guage rigid steel couduit on surface, with 2 nos 10 SWG copper earth continuity wire etc, complete in all respect 8 Add for Invertor Wiring in wiring Point for light/ Fan/ Plugwith 1.5 mm Cu Wire 9 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 10 Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 5/6 amps switch 11 Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 2 Way 5/6 amps switch 12 Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 3 pin 5/6 amp socket outlet 13 Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 6 pin 15/16 amp socket outlet Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 14 TV socket outlet 15 Telephone socket outlet 16 Supplying and drawing 4 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. Supply & fixing of following white RJ 45 cat 6 data outlet / information outlet ETL verified to meet exceed TIA / ETA 17 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 18 1 or 2 Module (75mmX75mm) Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 19 25 mm Dia 20 40 mm dia G.I Pipe (Medium class) 21 Supply & Installation of Safety Signage 22 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM(tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 23 Supply and fixing hexagonal Round G.P.fan box approved make made up of 1.0 mm thickISI Marked G.P.sheet spot welded Four to Eightholes for pipe entryof the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed. Fixing with wiring conduit laid in the R.C.C. roof before concretingalongwith supply of all material, labour, T&P etc. required for proper completion of the work. 24 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 25 Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT AAA 26 Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect. CAT AAA 27 Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in all respect CAT AA 28 Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. CAT-AAA 29 Supplying and fixing PVC batten/ angle holder including connections etc. as required. 30 Installation ,Testing, Commissioning of wall bracket /ceilingfittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 31 Supply and fixing of Mirror Light 10 Watt LED. complete in all respect(only for estimation) Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 32 Upto 450 mm sweep 33 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. Supply of AC 230/250 Volts, 50 Hz 180 w 1440 rpm Heavy duity Wall Fan including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required. 600 mm sweep.-Make: USHA Cat No. Dominaire600 mm sweep.-Make: USHA Cat No. Dominaire Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) 4 way (4 + 12), Double door 34 8 way (4 + 24), Double door 35 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole Supplying and fixingof 63 Amp. 4 pole MCB(10 KA) C Curve Supplying and fixingof 40 Amp. 4 pole MCB (10 KA)CAT A CAT A 36 Supplying and fixin of 40 Amp. DP MCB (10 KA) C CurveCAT A 37 Supplying and fixingof 63 Amp. DP MCB (10 KA) CAT A 38 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. Supply & Erracetion of factory fabricated & wiredmetal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheetwith a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only Incomming : One (1) No. 400 Amp. MCCB - 1 No 39 Ooutgoing 200 Amp. MCCB-2 Nos,100 Amp MCCB- 1 No, & 63 Amp MCCB-1 No Cat. A Pannel Cubicle Type Cat. B.Pannel Cubicle Type 100 Amp.MCCB-3Nos. & 63 Amp.MCCB-2Nos. 40 Cat. A Pannel Cubicle Type Cat. B.Pannel Cubicle Type 41 Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. 42 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 43 Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30cm square C.I. frame with hinged cover & masonry housing.Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. 44 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 45 Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. 46 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor and external lighting complete as required. (For Horizontal run) 47 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run) 48 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 49 Supply & installation of CCTV / Suvillance system. (Honeywell 40 channel NVR full HD IP based- 01 nos, IP Honeywell dome camera 2MP with night vision- 12 nos., IP Honeywell 2 MP HD Bullet camera with night vision- 30 nos.)work should be completed asper standard drg anddirection and satisfaction of engineer incharge. 50 Supply & Structure Computer networking system, work should be completed asper standard drg anddirection and satisfaction of engineer incharge. 51 Supply Installation, testing & Commissioning of LG make indoor & Out door unit with electronic expansion valve. 1.5 TR HI-WALLwork should be completed asper standard drg anddirection and satisfaction of engineer incharge. 52 WIRED/WIRELESSREMOTE 53 Indoor Y Joints. 54 Outdoor Y Joints. 55 SITC of Interconnecting refrigerant pipe work with (19mm/13 mmthick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger Pipe Size (O.D.) 53.98 mm ( 25mm Thickness ofInsulation)work should be completed asper standard drg anddirection and satisfaction of engineer incharge. 56 Drain Piping Rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation. 25 MM 57 MS Stand 58 Control & Transmission Wiring Providing and fixing control cum transmission wiring of 2 core X 1.5 sq.mm Coppershieldedbetween indoors & Outdoor running thru suitable size ofPVC Condutes work should be completed asper standard drg anddirection and satisfaction of engineer incharge. 59 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cablerun shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc 25 sq. mm 3-1/2 core 60 35 sq. mm 3-1/2 core 61 50 sq. mm 3-1/2 core 62 70 sq. mm 3-1/2 core 63 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer Incharge. 25 sq. mm 3-1/2 core 64 35 sq. mm 3-1/2 core 65 50 sq. mm 3-1/2 core 66 70 sq. mm 3-1/2 core 67 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12 mm thik) having 3mm thikness with Single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect. 68 Supply and fixing of LED street light fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 watt. Confirming to IP 66 and above protection complete in all respect. 69 Supply and fixing of 20 Amp DP MCB (10KA) (C curve) for poles 70 Supply and fixing of Bakelite sheet 3 mm thick of suitable size & connector 71 Wiring for light/ Power plug with 2X4 sq. mm FRLS PVC insuleted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1Nos. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthingas required. 72 Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. 73 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 74 ProvidingandfixingMV danger notice plate of 200 mm x 150 mm made of mild steel at least 2mmthick &vitreousenamelledwhiteon bothsides and withinscription insignalred colouronfront side as required. 75 ProvidingandfixingHT danger notice plate 250 mm x 200 mm made of mild steel at least 2mmthick &vitreousenamelledwhiteon bothsides and withinscription insignalred colouronfront side as required. 76 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge 77 Supplying & Layingof 1800 mm x 900 mm X 12 mm thick chequered rubber matting of tested quality 78 Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules. (only for estimation) 79 S/F of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T & Pfor proper completion of work. 80 Providing & fixing in position 1000 mm wide, Electrical Insulating Mats, 2mm thick, suitable upto 1.1 KV grade including cutting to required length complete as required per specifications or upto the satisfaction of engineer-in-charge. (only for estimation) 81 Supplying and Laying of Rubber mat 1000 mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652-2006 etc. as reqd. (only for estimation) 82 SUPPLY OF TOOL & FIRST AID BOX WITH ALL NECESSARY TOOLS FOR MATINTENANCE OF ELETRICAL INSTALLATION & FIRST AID ONLY FOR ESTIMATION 83 DG SET 62.5 KV Make Sudhir, Johson, nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM(tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.23 Supply and fixing hexagonal Round G.P.fan box approved make made up of 1.0 mm thickISI Marked G.P.sheet spot welded Four to Eightholes for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover dully screwed. Fixing with wiring conduit laid in the R.C.C. roof before concretingalongwith supply of all material, labour, T&P etc. required for proper completion of the work.24 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.25 Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminum housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT AAA26 Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect. CAT AAA27 Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection. complete in all respect CAT AA28 Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminum housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. CAT-AAA29 Supplying and fixing PVC batten/ angle holder including connections etc. as required.30 Installation ,Testing, Commissioning of wall bracket /ceilingfittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.31 Supply and fixing of Mirror Light 10 Watt LED. complete in all respect(only for estimation) Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.32 Upto 450 mm sweep33 Extra for fixing the louvers/ shutters complete with frame for an exhaust fan of all sizes. Supply of AC 230/250 Volts, 50 Hz 180 w 1440 rpm Heavy duty Wall Fan including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required. 600 mm sweep.-Make: USHA Cat No. Dominaire600 mm sweep.-Make: USHA Cat No. Dominaire Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/isolator) 4 way (4 + 12), Double door34 8 way (4 + 24), Double door35 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole Supplying and fixing of 63 Amp. 4 pole MCB(10 KA) C Curve Supplying and fixing of 40 Amp. 4 pole MCB (10 KA) CAT A CAT A36 Supplying and fixing of 40 Amp. DP MCB (10 KA) C CurveCAT A37 Supplying and fixing of 63 Amp. DP MCB (10 KA) CAT A38 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. Supply & Erracetion of factory fabricated & wiredmetal clad dust and vermin proof floor mounting, M.S. The panel board shall have The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounding of the board as per directions of Engineer-in-charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only Incoming : One (1) No. 400 Amp. MCCB - 1 No.39 Outgoing 200 Amp. MCCB-2 Nos,100 Amp MCCB- 1 No, & 63 Amp MCCB-1 No Cat. A Panel Cubicle Type Cat. B.Pannel Cubicle Type 100 Amp.MCCB-3Nos. & 63 Amp.MCCB-2Nos.40 Cat. A Panel Cubicle Type Cat. B.Panel Cubicle Type41 Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.42 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.43 Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30cm square C.I. frame with hinged cover & masonry housing.Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.44 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.45 Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.46 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor and external lighting complete as required. (For horizontal run)47 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run)48 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.49 Supply & installation of CCTV / Surveillance system. (Honeywell 40 channel NVR full HD IP based- 01 nos, IP Honeywell dome camera 2MP with night vision- 12 nos., IP Honeywell 2 MP HD Bullet camera with night vision- 30 nos.)work should be completed asper standard drg anddirection and satisfaction of engineer in charge.50 Supply & Structure Computer networking system, work should be completed as per standard drg and direction and satisfaction of engineer in charge.51 Supply Installation, testing & Commissioning of LG make indoor & Out door unit with electronic expansion valve. 1.5 TR HI-WALLwork should be completed asper standard drg anddirection and satisfaction of engineer in charge.52 WIRED/WIRELESSREMOTE53 Indoor Y Joints.54 Outdoor Y Joints.55 SITC of Interconnecting refrigerant pipe work with (19mm/13 mmthick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger Pipe Size (O.D.) 53.98 mm ( 25mm Thickness ofInsulation)work should be completed asper standard drg anddirection and satisfaction of engineer in charge.56 Drain Piping Rigid PVC piping complete with fittings, supports as per specifications and dually insulated with 6 mm thick closed cell nitrile rubber insulation. 25mm57 MS Stand58 Control & Transmission Wiring Providing and fixing control cum transmission wiring of 2 core59 Supply and laying of aluminum conductor PVC insulated armored served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-In-Charge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc 25 sq. mm 3-1/2 core60 35 sq. mm 3-1/2 core61 50 sq. mm 3-1/2 core62 70 sq. mm 3-1/2 core63 Supply and fixing of brass nickel plated compression gland for PVC insulated & armored served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer Incharge. 25 sq. mm 3-1/2 core64 35 sq. mm 3-1/2 core65 50 sq. mm 3-1/2 core66 70 sq. mm 3-1/2 core67 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12 mm thick) having 3mm thickness with Single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect.68 Supply and fixing of LED street light fitting having die cast aluminum body and diffuser with driver set suitable for 45 watt to 50 watt. Confirming to IP 66 and above protection complete in all respect.69 Supply and fixing of 20 Amp DP MCB (10KA) (C curve) for poles70 Supply and fixing of Bakelite sheet 3 mm thick of suitable size & connector71 Wiring for light/ Power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1Nos. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthingas required.72 Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.73 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.74 ProvidingandfixingMV danger notice plate of 200 mm x 150 mm made of mild steel at least 2mmthick &vitreousenamelledwhiteon bothsides and withinscription insignalred colouronfront side as required.75 ProvidingandfixingHT danger notice plate 250 mm x 200 mm made of mild steel at least 2mmthick &vitreousenamelledwhiteon bothsides and withinscription insignalred colouronfront side as required.76 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 liters capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge77 Supplying & Laying of 1800 mm x 900 mm X 12 mm thick checkered rubber matting of tested quality78 Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules. (only for estimate)79 S/F of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labor T & Pfor proper completion of work.80 Providing & fixing in position 1000 mm wide, Electrical Insulating Mats, 2mm thick, suitable upto 1.1 KV grade including cutting to required length complete as required per specifications or upto the satisfaction of engineer-in-charge. (only for estimate)81 Supplying and Laying of Rubber mat 1000 mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652-2006 etc. as reqd. (only for estimate)82 SUPPLY OF TOOL & FIRST AID BOX WITH ALL NECESSARY TOOLS FOR MATINTENANCE OF ELECTRICAL INSTALLATION & FIRST AID ONLY FOR ESTIMATION83 DG SET 62.5 KV Make Sudhir, Johson,