}

Tender For Supply Of Material And Work Sechudle For Strengthening Of132kv Sgpgi Ckt-I &Iibay At 220 Kv Substation Bijnaurand 132Kv Bijnaur Ckt-I &Iibay At 132 Kv Substation Sgpgi For Replacement Of Panther Conductor With Htls Of 132Kv Bijnaur -Sgpgi Ckt-I, lucknow-Uttar Pradesh

Uttar Pradesh Power Transmission Corporation Limited has published Tender For Supply Of Material And Work Sechudle For Strengthening Of132kv Sgpgi Ckt-I &Iibay At 220 Kv Substation Bijnaurand 132Kv Bijnaur Ckt-I &Iibay At 132 Kv Substation Sgpgi For Replacement Of Panther Conductor With Htls Of 132Kv Bijnaur -Sgpgi Ckt-I. Submission Date for this Tender is 15-09-2025. Substation Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

50840428
Tender For Supply Of Material And Work Sechudle For Strengthening Of132kv Sgpgi Ckt-I &Iibay At 220 Kv Substation Bijnaurand 132Kv Bijnaur Ckt-I &Iibay At 132 Kv Substation Sgpgi For Replacement Of Panther Conductor With Htls Of 132Kv Bijnaur -Sgpgi Ckt-I
Tender
Indian
Uttar Pradesh
Lucknow
15-09-2025

Tender Details

Tender For Supply Of Material And Work Sechudle For Strengthening Of132kv Sgpgi Ckt-I &Iibay At 220 Kv Substation Bijnaurand 132Kv Bijnaur Ckt-I &Iibay At 132 Kv Substation Sgpgi For Replacement Of Panther Conductor With Htls Of 132Kv Bijnaur -Sgpgi Ckt-I &Ii Transmission Lines - P.G Clamp ACSR Panther to Panther conductor 3 P.G Clamp ACSR Moose to Panther conductor 4 P.G Clamp ACSR Moose to Moose conductor 5 Spacer for Twin Moose Conductor 02 Bolts, 100 mm spacing made of Aluminium alloy LM-6 complete with nuts,bolts & washers confirming to BIS:5561 6 Spacer for Twin Panther Conductor 02 Bolts, 100 mm spacing made of Aluminium alloy LM-6 complete with nuts,bolts & washers confirming to BIS:5561 7 Spacer for Twin Moose Conductor 02 Bolts, 250 mm spacing made of Aluminium alloy LM-6 complete with nuts,bolts & washers confirming to BIS:5561 8 Bolted type Tension fitting for Twin Moose conductor w/o Turn buckle for 132 KV Main Bus Bar suitable for 70 KN Disc Insulator string with 02 No. Tension Clamps made of Al. Alloy LM-6 Yoke Plate,D-Shackle,D-Socket etc. made from Forged Steel etc. 9 132 kV/220kV Suspension Insulator string and associated hardware fittings with drop clamp suitable for twin moose conductor. 10 20 MM GI U-Bolt of MS rod having thread on both side complete with washer and spring washer 04 nos. sample confirming to BIS:5561 11 132 KV P.T Clamp/Connector duly made of Aluminium Alloy (LM-6) Suitable forACSR Panther Conductor complete with bolts, nuts & Washers as per sample Conferming to BIS:5561. 12 132 KV Isolator Clamp/Connector duly made of Aluminium Alloy (LM-6) Suitable for Twin ACSR Panther Conductor complete with bolts, nuts & Washers as per sample . 13 132 KV IsolatorClamp/Connector duly made of Aluminium Alloy (LM-6) Suitable forACSR Moose Conductor complete with bolts, nuts & Washers as per sample . 14 132 KV C.B Clamp/Connector duly made of Aluminium Alloy (LM-6) Suitable forACSR Moose Conductor complete with bolts, nuts & Washers as per sample (Heptacare Make) 15 132 KV L.A Clamp/Connector duly made of Aluminium Alloy (LM-6) Suitable forACSR Moose Conductor complete with bolts, nuts & Washers as per sample Conferming to BIS:5561. 16 P.G Clamp ACSR Panther to Panther conductor 17 P.G Clamp ACSR Moose to Panther conductor 18 P.G Clamp ACSR Moose to Moose conductor 19 Supply and installationin Complete respect 2 Tonne Split ACfive star (Hitachi/O genral,Daikin or Eq make) with all Accessories and Stabliser( Not Less Than 05 KV Capacity) 20 132 KV P.T Clamp duly made of Aluminium Alloy (LM-6) Suitable forACSR Panther Conductor complete with bolts, nuts & Washers as per sample Conferming to BIS:5561. 21 132 KV Isolator Clamp duly made of Aluminium Alloy (LM-6) Suitable forACSR Moose Conductor complete with bolts, nuts & Washers as per sample . 22 132 KV C.B Clamp duly made of Aluminium Alloy (LM-6) Suitable for ACSR Moose Conductor complete with bolts, nuts & Washers as per sample (Heptacare Make) 23 132 KV L.A Clamp duly made of Aluminium Alloy (LM-6) Suitable forACSR Moose Conductor complete with bolts, nuts & Washers as per sample Conferming to BIS:5561. 24 5 KVDigital Insulation Tester (Megger) 25 Digital Multimeter (4 1/2 Digit) (Motwane Make or equivalent) 26 Clamp on meter (Digital) (0-300-600 A) 27 Work 28 Opening of existing jumpers of Twin/Single ACSR Panther/Zebra conductors ( 03 phase ) between 132KVMain Bus -Ito 04 No. Line Isolator,02 No. T/F,02 No. P.T,02 No.to Main Bus-I (01 Job for each Bay). 29 Opening of existing jumpers of Twin/Single ACSR Panther/Zebra conductors ( 03 phase ) between 132KV Main Bus -II to 04 No. Line Isolator,02 No. T/F,02 No. P.T,02 No.to Main Bus-II (01 Job for each bay). 30 De-Stringing & Dismantling of existing 132 KV Main Bus-Iof Single ACSR Zebra conductors after opening of Disc Insulator string & Tension Fitting from Gantry,lowering the Bus Bar conductors including shifting of the old conductor from switchyard to substation store and stacking/placing of same at suitable place at the stores (01 Job for each phase of each section of Bus Bar) 31 De-Stringing & Dismantling of existing 132 KV Main Bus -II of Single ACSR Zebra conductors after opening of Disc Insulator string & Tension Fitting from Gantry,lowering the Bus Bar conductors including shifting of the old conductor from switchyard to substation store and stacking/placing of same at suitable place at the stores (01 Job for each phase of each section of Bus Bar) 32 Laying & Re-Stringing of132 KV Main Bus -I of Twin ACSR Moose Conductors including Hoisting of Disc Insulator string & Tension Fitting etc. including shifting of the conductors/Materials from store to switchyard(01 Job for each phase of each section of Bus Bar) 33 Laying & Re-Stringing of132 KV Main Bus -IIof Twin ACSR Moose Conductors including Hoisting of Disc Insulator string & Tension Fitting etc. including shifting of the conductors/Materials from store to switchyard(01 Job for each phase of each section of Bus Bar) 34 Preparing the jumpers of Twin ACSR Panther/Moose conductors (03 phase) and connecting the same between newly laid 132 KV Main Bus Bar to 05 No. Line Isolator,03 No. T/F,02 No. P.T,01 No. Section Isolator bay to Main Bus -1(01 Job for each bayr). 35 Preparing the jumpers of Twin ACSR Panther/Moose conductors (03 phase) and connecting the same between newly laid 132 KV Main Bus Bar to 05 No. Line Isolator,03 No. T/F,02 No. P.T,01 No. Section Isolator bay to Main Bus-2 (01 Job for each bayr). 36 Jointing Section of 132 KV Main Bus by U shaped Twin Jumpers between adjacent bus Section with the help of suitable double P.G Clamp (01 Job for each bay) 37 Opening of existing jumpers of Twin/Single ACSR Panther/Zebra conductors ( 03 phase ) between Main Bus to 03 No. Line Isolator,03 No. CT,03 No. P.T,03 No. Bus Isolator bay to Main Bus (01 Job for each Jumper).for 132KV Bijnaur bay at 132KV S/S SGPGI 38 Opening of existing jumpers of Twin/Single ACSR Panther/Zebra conductors ( 03 phase ) between Main Bus to 03 No. Line Isolator,03 No. CT,03 No. P.T,03 No. Bus Isolator bay to Main Bus (01 Job for each Jumper).for 132KV Sarojini Nagr -2bay at 132KV S/S SGPGI 39 Preparing the jumpers of Twin ACSR Panther/Moose conductors (03 phase) and connecting the same between132 KV Main Bus Bar to 03 No. Line Isolator,03 No. CT,03 No. P.T,03 No. Bus Isolatorto Main Bus (01 Job for each Jumper)..for 132KV Bijnaur baty at 132KV S/S SGPGI 40 Preparing the jumpers of Twin ACSR Panther/Moose conductors (03 phase) and connecting the same between132 KV Main Bus Bar to 03 No. Line Isolator,03 No. CT,03 No. P.T,03 No. Bus Isolatorto Main Bus (01 Job for each Jumper)..for 132KV Sarojini Nagrbay-2 at 132KV S/S SGPGI 41 Dismantling of 145 KV 400-200/1A C.T 42 Errection of 145 KV 800-400-200/1A C.T 43 Dismantling of Old Protection Panel 44 Errection of New Protection Panel 45 Laying of following size control cables in Trench from C&R Pannel to various equipment. 46 2CX2.5Sqmm 47 4CX2.5Sqmm 48 6CX2.5Sqmm 49 Interconnection and Termination of Various Size control Cable between Feeder and C&R pannel/DPP to various equipments. 50 Dismantling of 120 KV Old LA 51 Erection of 120 KV New LA 52 Dismantling of 145 KV New P.T 53 Errection of 145 KV New P.T 54 Erection of 132 KV PT Junction Box

Key Value

Document Fees
INR 1770 /-
EMD
INR 47000.0 /-
Tender Value
INR 47 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail