| 1 | Supplying and drawing of CAT-6, 4 Pair UTP 23 AWG Cablein the existing surface /recessed PVC conduit /casing caping etc as required.. Make:CP Plus Model CP-EUT-6TGL23-100 or equivalent as per the direction of EIC |
| 2 | Supplying and fixing of RJ-45 CAT-6 Information Outlet Socket. Make: Anchor or equivalent as per the direction of EIC |
| 3 | Supplying and fixing of 2-Module Surface PVC Modular Box Make: Anchor or equivalent as per the direction of EIC |
| 4 | Supplying and fixing CAT-6 Patch Cord ,UTP,Stranded 24 AWG (2 Meter length) Make: CP Plus or equivalent as per the direction of EIC |
| 5 | Supplying, Installing, testing and commissioning of 16-Port Gigabit Ethernet Switch Make: Digisol or equivalent as per the direction of EIC |
| 6 | Supplying, Installing, testing and commissioning ofGigabit Ethernet Switch Make: Digisol or equivalent as per the direction of EIC |
| 7 | 8-Port Gigabit Ethernet Switch |
| 8 | 5-Port Gigabit Ethernet Switch |
| 9 | Supplying and installation of Wall mount modular rack 2U Size with acrylic fiber glass door Lock n key (450 mm x 350 mm) Make CP Plus Model CP-HA-RK4535VM-2U or its equivalent |
| 10 | Supplying and fixing of following size of ISI medium class PVC conduit/casing caping along with all accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 11 | 25 mm |
| 12 | Supplying, Installation, Testing and Commissioning of3 KVA Online UPS Make- Numeric Model- Valura Single Phase with Battery type SMF 12 Volt 100 AH - 08 Nos , Make ExideModel EP100-12 with LED/LCD Display Indications with suitable steel rack for placing the battery or any equivalent make as per the specifications |
| 13 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 14 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 15 | 2 X 4.0 sq. mm + 1 X 4.0 sq. mm earth wire |
| 16 | 2 X 6.0 sq. mm + 1 X 6.0 sq. mm earth wire |
| 17 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 18 | 8-way Double Door |
| 19 | 6-way Double Door |
| 20 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 21 | 40 Amps |
| 22 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 23 | Single Pole |
| 24 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |