Construction Of Faecal Sludge Treatment Plant Fstp Of Capacity 5Kld At Chouldari Under Aeii, Cdiii, Apwd, Prothrapur.Re Call- 1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2 All kinds of soil. 3 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 4 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 5 Clearing jungleincludinguprootingof rank vegetation,grass,brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 6 Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : 7 1:2:4 (1cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 8 1:4:8 (1Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) 9 Centering and shuttering including strutting, propping etc. and removal of form work for: 10 Foundations, footings, bases for columns 11 Centering and shuttering including strutting, propping etc. and removal of form for 12 Foundations,footings,basesof columns,etc.formass concrete 13 Walls (anythickness)includingattachedpilasters, butteresses, plinth and string courses etc. 14 Suspended floors,roofs,landings,balconies and access platform 15 Lintels,beams,plinthbeams,girders,bressumersand cantilevers 16 Columns, Pillars, Piers, Abutments, Posts and Struts 17 Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level. 18 Thermo-Mechanically Treatedbars of gradeFe-500D or more. 19 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforcedcement concrete work;usingcoarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /PortlandSlag cement,admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete,toimprovedurabilityandworkabilitywithoutimpairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 20 All works upto plinth level 21 Concrete of M30 grade with minimum cement content of 350 kg /cum 22 All works above plinth level upto floor V level 23 Concrete of M30 grade with minimum cement content of 350 kg /cum 24 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 25 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 26 Hot finished welded type tubes 27 Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. 28 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 29 G.I. pipes 30 Cement concrete flooring 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 31 40 mm thick with 20 mm nominal size stone aggregate 32 Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : 33 Ridges plain (500- 600mm) 34 12 mm cement plaster of mix: 35 1:4(1 cement: 4 fine sand) 36 12 mm cement plaster finished with a floating coat of neat cement of mix: 37 1:4(1 cement: 4 fine sand) 38 Finishing walls with Acrylic Smooth exterior paint of required shade: 39 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 40 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 41 Two or more coats on new work 42 Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: 43 Two or more coats on new work 44 Providingandlaying 60mmthickfaciorymadecementconcrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 45 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in- charge. 46 Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade 47 Providing and laying hollow cement concrete block walling 200mm thick consisting of hollow block size 400x200x200mm of mix 1:3:6 (1cement: 3 coarse sans : 6 graded stone aggregate 20mm nominal and down size) lain in cement mortar 1:6 (1 cement : 6 coarse sand). 48 Providing and fixing precoated galvalume(PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel everest industries Ltd.,JSW steel lts. Jundal India Lts. or equevalent(size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with aluminium zinc coating 150 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping luminium screws (Xylan) of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 49 Providing filter media with 2 to 12mm stone chips laid for sludge drying bed including carriage, filling all complete. 50 Construction of Faecal sludge treatment plant (FSTP) of capacity 5KLD at Chouldari under AE-II, CD-III, APWD, Prothrapur.Sub Work:- Providign IEI, EEI, machinery & equipments and DG set. 51 AbstractC Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. a) Group C 52 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 53 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.a)2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 54 b)2 X 6 sq. mm + 1 X 6 sq. mm earth wire 55 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required 56 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required 57 Supplying, Installation, Testing and Commissioning of 28W BLDCCeiling Fan (1200 mm), SweepISI Marked without regulator with all accessories etc as required,Make: Havells Model No. Efficiencia DX BLDC or its equivalent etc., as required. 58 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 59 Supplying of Exhaust Fan (Non Metallic Type) 250 mm sweepwith accessories etc as equivalent to Havells Model Venti Air DX or its equivalent as required 60 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.a) Upto 450 mm sweep 61 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block includingonnections etc. as required. 62 Supplying and fixing PVC batten/ angle holder including connections etc. as required. 63 Supplying of LED 9W Bulbin the existing Batten Holder LED 9W Bulb as Similar to Philips Cat : 85395200 or its equivalent make as required. 64 Supplying, Installation, Testing and Commissioning of CRCA housing Box type Luminaries suitable for T8 LED Tube (1 x 18 / 20W) as equivalent to Bajaj Model No. BLRB - DB 118 or its equivalent make as required 65 Supplying of 20 W LED Tube light with polycarbonate housing designed for high performance as equivalent to Bajaj: Model No. BLRB 20W LED or its equivalent make as required. 66 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts,10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as requireda) Single Pole 67 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40 A 68 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)a)8 way, Double Door 69 Providing earthing with safe earthing electrode of galvanization 80 to 100 microns, length 2 mtr, outer dia 50 mm, inner dia 19 mm and inner space be filled with crystalline conductive mixture including filling -up with electrolite (Back fill compound) as required for safe earth electrode and providing masonary enclosure with cover plate having locking arrangement etc. as required. (Ashlok)Note:Proof / Test Certificate should be enclosed) 70 Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. 71 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 72 AbstractD Supplying of 65mm DiaB Class G.I Pipe ofLength 6 Mtrs (Standardlegnth) having welded 40mm Dia B class G.I Bend pipe at the top to fix Street light fittingand 1 No. 300mm x 300mm x 6 mmbase plate at the botton for grouting in thecontrete foundation including providing of cable entry pipe of size 50mm dia B classG.I pipe etc. as required 73 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. (a) Above 4.5 metre and upto 6.5 metre 74 Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted) 75 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 2 x 1.5 sq. mm 76 Supplying and fixing of SMC Junction Box of Size 140 mm x 140mm x 95mm ( inside ) suitabily embeded on the cement concrete collarand providing and fixing 1 No. 63 amps Four pole heavy duty SMC connector and 6 Amps SP MCB inside the SMC boxincluding connection etc as required. 77 Supplying and fixing of 30w LED street light fitting similar to Luker make product codeLSTE-30on the existing street light pole i/c connection etc as required. 78 Supplyingand Laying of following one Number Double walled corrugated high density polyethylene pipe having corrugation on the outer wall and plain surface inner wall conforming to IS: No. 14930 Part I & II complete with necessary HDPE fitting for protection of 1.1 KV grade directly in ground at the depthof 50 cm i/c excavation & refilling the trench etc as required. a)50mm outer dia and 38 mm inner dia 79 Supplyingand Laying of following one Number Double walled corrugated high density polyethylene pipe having corrugation on the outer wall and plain surface inner wall conforming to IS: No. 14930 Part I & II complete with necessary HDPE fitting for protection of 1.1 KV grade directly in ground /clamping on wall surfaceetc as required. a)50mm outer dia and 38 mm inner dia 80 Supplying of following sizes of XLPE insulated Heavy duty armoured aluminium conductor UG Cable of 1.1 KV Grade conforming to IS: 7098 (part-I) and IS No. 1554 (part-I) 1988 as applicable Make: CCI/ GLOSTER/ Havells/ Polycab/ Finolex.a) 16 Sqmm x 4 Core (M.S) 81 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL or DWC pipe as required. 82 a) Upto 35 sq. mm 83 b) 25 Sqmmx 3 .5Core 84 Supplying and making end termination aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 85 a)4 x 16 Sqmm ( 28 mm) 86 b) 3.5x 25 Sqmm ( 28 mm) 87 Provision for Externalservice connection from the electricity department 88 AbstractESupply,installation,testingandcommissioningofNon clogSubmersibleRawSewageTr.pumpingsetwithCI body & impeller, connected to a motor suitable for 415 +/ 10%volts, 3 phase 50 cycles A.C supply as required and directed by Engineer-in-charge( Make: Steron Pumps3 Hp, 3 Phase or Equivalent) 89 Raw Sewage Transfer Pump- Make: Kirloskar/Lubi or Equivalent 90 (PumpstobesuitabletohandleSolidhandlingcapacity upto 28 mm size) WITH ALL FITTINGS 91 No. ofpumps : 02 Nos.(1 Working + 1 Standby) 92 Capacity - 2.50 M3/Hr 93 Head - 8.0-10 Mtr. 94 Supply, installation, testing & commissioning of Twin lobe rotary type Air blower& suitable motor of 415 ± 10% volts, 3 phase, 50 cycles A/C supply as required and directed by Engineer-in-charge 95 No. ofBlower : 02 no. (1 Working + 1 Standby) Make: blowvacc/KPT or Equivalent 96 Capacity - As per OEM calculation 97 Head - 3.0- 3.5 Mtr. 98 pressur 0.3 ccm 99 Supply,installation,testing&commissioningof EPDM TubulertypefinebubblediffusershavingLengthof 1000/600mmanddia willbe63mmwithdiffusion capacity 5-8 m3/hr for MBBR reactors .( Make: Scogen/EDI/OTT or Equivalent) as 1 Lot= 60 Pieces 100 Supply,installation,testing&commissioningof Lateral & Header typeCoarse bubblediffussion system having diffusion capacity 3-5 m3/hr for equilisation tank, Anoxic tank & Sludge Holding tank .( Make: As per OEM) as 1 Lot= 60 Pieces 101 Supply,installation,testing&commissioningof Lateral &Headertypesewagedistributiongridforupflow Anaerobic bacteria, ecogiya. ( Make: As per OEM) 102 Supply,installation,testingandcommissioningof floating /Fixed upflow Anaerobic filtermedia made of PVC/HDPE having surface area of 100-125 m2/m3 . ( Make: Guddi /Airfin or Equivalent) 103 Type : Floating Ring/Fixed 104 Fins: Internal 105 Surface Arae : 100-125 m2/m3 106 Color : Black 107 Treatment : UV sterlized 108 MOC : HDPE 109 Supply,installation,testingandcommissioningofhigh surfaceareafloatingMBBR media made ofPVC/HDPE havingsurfaceareaof400m2/m3tobeusedinMBBR Reactor .( Make: Guddi /Airfin or Equivalent) 110 Type : Floating Ring 111 Fins: Internal 112 Surface Arae : 400 m2/m3 113 Color : Black 114 Treatment : UV sterlized 115 MOC : HDPE 116 Supply,installation,testingandcommissioning of OZONATER 5 gm as required and directed by Engineer-in-Charge ( Make: Guddi /Airfin or Equivalent) 117 Supply,installation,testingandcommissioningoffilter feedpumpofhorizontalcentrifugalpumpingsetof suitable horsepower as required withCI body & impeller, shaft of Carbon steel and C.I. base & head with mechanical seal, connected to a TEFC induction motor suitable for 415+/-10%volts, 3 phase 50 cycles A.C supply including suction and delivery headers with G.I as required and directed by Engineer-in-Charge( Make: Kirloskar/Shakti2 HP 3PhaseMonobloc Pump KDI-225++ or Equivalent) 118 Filter Feed Pumps- 119 No. ofpumps : 02 Nos.(1 Working + 1 Standby ) 120 Capacity- 2.5 m3/hr 121 Head - 25.0-30 Mtr. 122 Supplying,installation,testing&commissioningof MSEP/FRPvesselfilterwithfrontalpipingand Valves with all the required accessories. Filter shallinclude media,standardfittingslike,samplingcock,rinsedrain etc as required and directed by Engineer-in-Charge 123 Mulitgrade Filter 124 Capacity - 2.5 m3/hr 125 Filtration rate -12000lph/sqm 126 Filter dia approx. -400 mm 127 Working pressure: 2.5 Kg/sqcm. 128 Test pressure : 4. 5 Kg/sq cm 129 Supplying,installation,testing&commissioningof Activated Carbon Filter as required and directed by Engineer-in-charge( Make: Aventura/Starlit or Equivalent) 130 Capacity - 2.5 m3/hr 131 Filtration rate -12000lph/sqm 132 Filter dia approx. - 400 mm 133 Working pressure: 2.5-3.0 Kg/sqcm. 134 Test pressure : 4. 5 Kg/sq cm 135 Hypo Dosing System 136 Supplying, Installation, testing and commissioning of floclationagent/settlingagentdosingsystemcomprising ofSintexTankwithinlet/outletconnection,pipingand valves along with metering pump & Tank for dosing. 137 Flow rate (each)= 0-6 LPH 138 Head = 3-4 mtr 139 No. of Pumps: 02 Nos. ( 1 working + 1 Stand by ) 140 Tank Capacity : 100 Ltrs 141 Supply,installation,testing&commissioningofMSFRP tanks,Thesetankshouldbefabricatedfrom4/5mm thick for side wall & bottom respectively along with 1 mm FRP liningcomplete in all respects for making the system complete. 142 lameela clarifier for 20 min. detetion time 01 no. 143 MBBR Tank : 2 hours detetion time 02 Nos. 144 lamella tyep Settler : 20 min. detetion time 01 no 145 holding sump 2-3 cum 146 Supply, installation, testing & commissioning of all pipings (asdescribedbelow)andisolationcontrolvalves including all necessary fittings and clamps, supports, hangers as required i/c cutting and making good the walls wherever required complete in all respects for making the system complete. ( Make: TATA/Jindal/su preme or Equivalent) 147 uPVC : Submerged air piping 148 MSEpoxy/uPVC :Airpiping&pumpedeffluentriser (non-submerged) 149 Supplying, Installation,testingandcommissioningofmotorcontrol centre fabricated out of 14 gauge CRCA sheet steel. Cable glandplatesshallbeprovidedontopaswellasatthe bottomofthepanels.Panelsshallbetreatedwithall anticorrosive process before painting as per specificationswith2coatsofredoxideprimerandfinal approvedshadeofpowdercoatedpaint.2Nos.earthing terminalsshallbeprovidedfor3phase,4wire,50Hz supply system. Lifting hooks shall also be provided in case oflargepanels.Approvalshallbetakenforeachpanel before fabrication. Quoted rates shall be inclusive of cables (in accordance to specification) with earthing from paneltoeachmotor/equipmentandInstrumentationas required 150 AbstractCMotor Control Centre 151 Necessarycablealleys,internal/cabling,wiring,cabling from MCC to various pumps/equipment and interlocking, earthing for all equipment shall also included All motor & pumps shall be provided with Automatic level controller elctric panel for atuomation system with all respect 152 Supplying, Installation, Testing and Commissioning of 10 KVA Diesel Generator Set with Water Cooled, Electric Start Diesel engine directly coupled with AC alternator 03 Phase, 415 Volts, 50 Hz @ 0.8 p.f, self excited, self regulated designed to run at 1500 rpm mounted on common base frame, standard control panel, integral fuel tank with 12V, 100 AH Battery and leads and accessories in all respect with CPCB approved acoustic enclosure similar to Generator Set of Make Ley poweretc., as required. 153 Supplying, installation, testing and Commisssioning of 10KVA Capacity AMF panel including connections etc as required., 154 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 155 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required 156 Supplying and fixing of 63A Four pole onload Changeover switch with side handle in Sheet SteelEnclosure complete as required 157 O &M cost are considering energy cost consumable of fuel and repairs @ 5% cost of electro mechanical part & repairs in O & M cost is considered @ 5% oftotal electric mechanical cost for 3years on (C+D+F)