| 1 | S&F in repair 45 W LED street lights, IP 66 & IK07 protected, housing made of powder coated single piece pressure die cast aluminium with heat dissipation housing with toughened glass cover and secondary lens on each LED & should be SMD type. The System Luminaire efficacy >= 120 lm/watt with High power LEDs is to be used and potted driver must be potted & has a unique BISR number with input voltage AC 120 V to 270 V AC with High voltage Cut off @ >= 300 V AC and auto resetting safety Input Frequency 50 Hz ±3% , Power factor > 0.95 driver Efficiency > 85 %, THD (I) < 10 %, humidity 10 % to 90 % RH, CRI >70, Working Temp -10 C to 50 C. The Luminaire shall be BIS certified and T.C certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70 % lumen maintaned and CCT 5700 K+335K. Surge protection shall be min>= 4 KV internal and min 10 KV external complete all as specified and directed.Note-: The manufacture should provide warranty of street light for 2 years. |
| 2 | Taking down old street light from pole for repairing of street light fitting /luminaries of any size/type/make control wiringincluding replacement of LED drivers 45/60/70 W and refixing the same street light on pole after repair,checking the continuity from pole to pole junction boxes all as directed. Note : The LED driver rate deemed to be included on the quoted rate. |
| 3 | S&F 36 W solarstreet light all in one with high efficiency mono crystalline solar PV module LiFePO4battery of capacity 12.8 V, 12 Ah with inbuilt BMS technology, MPPT charge controller, aluminium extruded body IP65 with serviceable battery compartment high efficiency LED for optimising battery autonomy complete all as specified and directed. |
| 4 | S&F thermoplastic cable junction box/enclosure (distribution box) for outdoor installation with knock outs for cable entry suitable for cable size 10-16 Sqm of dimension 300x200x105 mm with cable terminals and 01 no MCB (0-6 Amp) 10 KA , B curve , 230 volts complete fitted on pole with new ms clamp, nut bolt duly painted with synthetic enamelled paintover one coat of red oxide Zink crome primer on clamps complete all as specified and directed. |
| 5 | M&L for replacement of light grade GI bracket made out of 32 mm dia light grade pipe 1.2 mtr long bend to shape as directed fixed to steel tubular pole with two number MS clamp made out of 40x5 mm flat iron duly painted withtwo coats of synthetic enamelled paint over one coat of red oxide Zink crome primer with and including nuts, bolts etc complete all as specified and directed. |
| 6 | S & Fin replacement of digital street light timer programmable every 1 min, with back up of 6 years, 28 memory locations, current capacity 16 A, weekly program, with 1 changeover(C CD), Total for 28 programms all as specified and directed. Make: L&T/IndoAsian/Havells |
| 7 | M&L for painting of steel tubular pole with two coats of aluminium paints including painting to cross arms and clamps etc including preparation of surface by scrubbing and cleaning with wire brush and writing existing numbers of poles in 100 mm dia yellow colour circle with black paint 25mm high including 15 cm wide alternate black & yellow bands upto 1.5 height from ground level of following size complete all as specified and directed:- |
| 8 | 9m long |
| 9 | Taking out unserviceable / serviceable cable /UG cable of any size carefully fromtrenches/poles /ducts /LT panels, OH conductorsat different locations all as specified and directed. |
| 10 | Supply and laying ,fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board,insulated, armoured heavy duty electric cable with aluminium conductor, XLPE , 1100 volts grade, cross-sectional area of size 10 Sqmmsqmm 2 core withall as specified and directed. |
| 11 | Excavating in trenches n\"exc 1.5 m width and depth exc 1.5m but n\"exc 3m for foundation or for shafts, well cesspits, manholes etc / for laying of cable/ pipe etc n\"exc 10 sqm on plan and n\"exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 12 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.complete all as specified and directed. |
| 13 | Removal of surplus soil to a distance n\"exc. 50 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. |
| 14 | M&L for sand cushioning with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and directed.Note:- Punned thickness shall be considered for payment purpose. |
| 15 | M&L for road cutting of size n\"exc 20cm width and n\"exc 60cm depth for laying of cable including through GI pipe and making good the road with PCC (1:2:4) type B1 complete all as specified and directed. |
| 16 | Supply and laying cable protection bricks, common burnt clay sub class \"B\" designation 75 for protection of UG cable laid in trenches with axis of the bricks perpendicular to the axis of the cable complete all as specified and directed. |
| 17 | S&F galvanized steel water tubing(GI Pipe) light grade (ISI marked) with all fittings as in sleeving for cable protection & laid in trenches/ floor or fixed to wall, ceiling and pole of following bore complete as specified and directed :-Note : MS Clamp, nut bolts and washer shall be measured and paid seperatly for fixing with pole etc. |
| 18 | 50mm bore |