Tender For Construction Of Indore Mini Stadium At Govertment Inter College Lalitpur - Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 3.0 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.(1.50 to 3.00 M) 3 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 4.50 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m..(3.00to 4.50 M) 4 Excavating, supplying stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 5 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. 6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 7 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 8 Brick work with (non modular) bricks of class designation 150 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) 9 Brick work with brick of class designation 150 in foundation and plinth in cement mortar 1:4 (1 cement : 4 coarse sand) 10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 11 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 12 Brick work with (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) 13 Half brick masonry with (non modular) bricks of class designation150 in superstructure above plinth level up to floor V level. 14 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 15 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) raft foundation 16 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 17 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortarof mix 1:4 (1 cement :4 coarse sand) admixed with waterproofing compound conforming to IS : 2645 and approved byEngineer-in-charge including laying glass fibre cloth ofapproved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge. With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 18 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : :300 mm dia piles 19 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Single pile upto 50 tonne Safe capacity Initial test (Test Load 2.5 times the Safe capacity) 20 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Single pile upto 50 tonne Safe capacity Routine test (Test Load 1.5 times the Safe capacity) 21 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 22 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand) 23 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) 24 12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) 25 Forming groove of uniform size from 12x12 mm and upto 25x15 mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of appropriate size and thickness (not less than 2 mm), nailed to the under layer with rust proof screws and nails and finishing the groove complete as per specifications and direction of the Engineer-in-Charge. 26 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 27 Making drain along with the apron 150x150 28 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. 29 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm. 30 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with greycement slurry mixed with pigment to match the shade of the slab, including rubbing andpolishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick 31 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cementslurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 32 Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.complete. 33 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shade complete. 34 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level ,1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources). (100 mm C.C. Floor with Trimixing) 35 Supplying & laying of Surface pattern : Rain drop Flooring width 1.8M length; 18/21M thickness 7mm including all necessary T&P complete in direction of engineer in charge. 36 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate 37 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screw 38 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screw. Extra for cutting rebate in flush door shutters. 39 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On Both side only 40 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 41 Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 42 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 43 Fixing of Door, windows/ventilators chaukhats in position.(a) Door chaukhats 44 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 45 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre . 46 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 47 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. 48 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes (weights not less than 10 kg/ sqm). 49 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides 50 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 51 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete(a) 250 mm x 10mm 52 Providing and fixing stainless steel handles with screws etc. complete (a) 150 mm 53 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. 54 Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail.Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing. 30 mm thick plain PVC door shutters 55 Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturers specification and direction of engineerin- charge. 56 Providing and fixing self supporting steel roofing system for a hall or alike made up of structural grade steel sheet of912 millimeter width (tolerance+/-2millimeter), moulded at site using mechanical press dies to the desired curve and shape to form 605 millimeter wide interlocking panels.The interlocking panels shall be pressed to close the seam forming watertight joints for a span of 18.00 meter having archriseas 3.6 meter,archlength 29.00meter The base material made up of imported galvalume steel complying to ASTMA792 having base metal thickness of 1.20 millimeter (tolerace+/-0.02 millimeter) with alloy coating AZ150 and paint coating of regular modified polyster ,top coat 25micron and bottom coat12 micron as per approved colour ,including fixinghangers,clamps etc. as may benecessary of Proflex standard,including fixing skylight of 2 millimeter thick polycarbonate sheet of size 2x14 and turbo ventilator of 24 diameter to be installed a tevery 30 feet along the length of roof including finishing , testing and cleaning etc. complete. 57 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge. 58 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Light shade pigment using white cement. 59 Centering and shuttering including strutting, propping etc. and removal of form for all heights :Foundations, footings, bases of columns, etc. for mass concrete. 60 Centering and shuttering including strutting, propping etc. and removal of form for all heights :Suspended floors, roofs, landings, balconies and access platform. 61 Centering and shuttering including strutting, propping etc. and removal of form for all heights :Lintels, beams, plinth beams, girders, bressumers and cantilevers. 62 Centering and shuttering including strutting, propping etc. and removal of form for all heights :Columns,Pillars, Piers, Abutments, Posts and Struts. 63 Edges of slabs and breaks in floors and walls Under 20 cm wide. 64 Providing, fabricating and fixing / erection of 4-5 mm SS plate / MS Sheet Powder coated in approved shade at desired location as per approved shade at desired location as per approved drawinghaving Helvtica Font with 72mm size also including cost of providing and fixing of fasteners complete in all respects as per Engineer in Charge . 65 Providing supplying designing fabricating and fixing of signage and information board with Text and illustrations as per approved location and drawing & designingProviding & Fixing 450 x900 powder coated 4-6 mm MS Sheet and 25 mm corian Signage at desired locations with letters (in english, hindi and Braile) and illustrations thorough cut infilled or painted also including the cost of design. Fabrication onsite installation with all necessary accesories 66 Providing & Fixing 200 x 450 powder coated 2-4 mm MS / Aluminium Signage at desired locations with letters (in english, hindi and Braile) and illustrations thorough cut infilled or painted also including the cost of design. Fabrication onsite installation with all necessary accesories 67 Finishing wall with thematic artistic paint for graphics representing sports colourful combination in approveddesignproper completion of work at site asper E/I. 68 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 69 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 70 Providing & fixing 75mm dia vent pipes. 71 Providing & fixing of 75mm dia cast iron terminal guard. 72 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.M.D. -10- Circular shape 500mm internal diameter 73 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.M.D. -2.5- Circular shape 450mm internal diameter 74 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. 75 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid 76 Providing & fixing toilet paper holder C.P. brass 77 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 78 Providing and fixing Jaquar Make Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook of quality and make as approved by Engineer - in - charge. 79 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap 80 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 81 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 82 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 83 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 84 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern & jet)15 mm nominal bore 85 Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length15 mm nominal bore 86 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15mm nominal bore 87 Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. 88 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (Including C.I. trap for standard urinal with vent arm with operating and other couplings in C.P.brass: 50 mm dia) 89 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as perdirection of Engineer-in-charge and finished smooth.Granite Stone of approved shade 90 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.For Internal 15 mm nominal outer dia Pipes 91 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.For Internal 20 mm nominal outer dia Pipes 92 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.For Internal 25 mm nominal outer dia Pipes 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.For Internal 32 mm nominal outer dia Pipes 94 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall20 mm nominal bore 95 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall25 mm nominal bore 96 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall32 mm nominal bore 97 Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall 40 mm nominal bore 98 Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall 50 mm nominal bore 99 Painting G.I. pipes and fittings with two coats of anti corrosive bitumasticpaint of approved quality :40mm diameter pipe 100 Painting G.I. pipes and fittings with two coats of anti corrosive bitumasticpaint of approved quality :50mm diameter pipe 101 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :40mm diameter pipe 102 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :50mm diameter pipe 103 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore 104 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25mm nominal bore 105 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32mm nominal bore 106 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40mm nominal bore 107 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50mm nominal bore 108 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :25 to 40 mm nominal bore 109 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :50 to 80 mm nominal bore 110 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./H.P.H.D. plastic ball.40 mm nominal bore, 206 mm long, weighing not less than 690 gms 111 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 112 Supply, fixing, testing and commissioning of following Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve - IP65CB - 230VAC, as per specifications:-Lehry Make Automatic OHT Level Control System Consist of Following Items1) LEHRY Make On-Off Type Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve with CI Body & SS Disc 2) Level Float Switch- 5M 3) Control Box (a) IP 65 Finishing(250 x 160 x 115)mm (b) LED Lamps: Tank FULL, Tank EMPTY, Power (c) Power supply toggle switch (d) Accepts 230V Single Phase power supply and provides 24VAC to float switch and 230VAC to valve coil. (e) Accepts NO/NC feedback from float switch.40mm 113 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm dia (for rain water) 114 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion.Single Push Fit Coupler 110 mm dia 115 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion Single tee with door 110x110x110 mm 116 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansionPlain bend 87.5 deg 110 mm dia 117 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm dia 118 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 119 Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m² 120 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design:100mm dia SWpipe 121 Providing, fixing, jointing and testing,UPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes.75 mm 122 Providing, fixing, jointing and testing,UPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes.110 mm 123 Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge.110mm x 75mm x 50mm/40mm 124 Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge.110mm x 75mm 125 Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) 126 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :150 x 100mm size P-typeWith common burnt clay F.P.S. (non modular) bricks of class designation 150 127 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete:100 mm diameter 128 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).With common burnt clay FPS (non modular) bricks of class designation 150(i) For Sewer Line 129 Extra for depth for manholes: Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 150 130 Providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 131 Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work)40mm nominal bore. 132 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40mm nominal bore. 133 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (horizontal) 134 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick,finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 150 135 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group - C 136 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 137 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 138 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire 139 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 4 sq. mm earth wire 140 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 x 10 sq.mm + 2 x 6 sq.mm. earth wire 141 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 x 16 sq.mm + 2 x 6sq.mm. earth wire 142 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. 143 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 144 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). 145 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 146 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required 147 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required 148 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 149 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 150 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 151 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep 152 Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. 153 Supply of Surface mounting 2x2 feet 36W to 42W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 154 Supply of LED 4ft 40W LED Tube light with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 3000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 42W (including driver). 155 Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 21W (including driver). 156 Supply of Surface mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 157 Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.Including connection with 1.5 sqmm FRLS PVC insulated copper conductor as required. 158 Supplying of LED mirror light luminaire with 10Wwatt complete with electronic ballast, lamp including connection etc. complete as required, Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. 159 Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 1100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect, 160 Supply of LED Flood light 350 Watt , suitable for 24Hr Continuous peration, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect, 161 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan 162 Supplying, erection, connecting, testing and commissioning of 400 mm Wall Fancomplete in all respect. 163 Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.300mm EXHAUST FAN 164 Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double Door 165 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way Double door 166 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way Double door 167 Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 amps 4P MCB 168 Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 amps 4P MCB 169 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required.25 amps 170 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required.40 amps 171 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 172 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole 173 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 174 Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.0mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCBs to be used.All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports.The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. The minimum clearances between bus bars shall be as follows :Phase to phase - minimum 20mm Phase to neutral-minimum 15mm MAIN LT PANEL Incoming :1 No 160 Amp. 4P MCCB of 25KABreaking capacity 1 No 160 Amp. 4P ATS Metering :1 Set of CTs one of 160/ 5Amp ratio for Multifunction Meter 1 Set of Phase Indication Lamp.Bus Bar :1 No. 200 Amp.TPN aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.2 No. 63 Amp 4PMCCB 6 No. 40 Amp 4PMCCB 3 No. 32 Amp 4PMCCB SPARE & SPACE- 2 No Panel described as above 175 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each 176 Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. 177 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 178 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 179 Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. 180 Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes: 2 Pair (4 core) 181 Providing, laying, connecting and testing of multi-core telephone armoured cable of conductor size 0.5mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable along wall or ceiling or through existing pipe.10 Pair telephone cable 182 Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted.10 pair tag block 183 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20mm dia PVC conduit 184 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm dia PVC conduit 185 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.32mm dia PVC conduit 186 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required1 or 2 Module (75mmX75mm) 187 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as requiredTelephone socket outlet 188 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as requiredRJ-45 Data Socket outlet 189 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable 190 Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq.mm. and upto 185 sq.mm. 191 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Up to 35 sq.mm. 192 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Above 95 sq.mm. and upto 185 sq.mm. 193 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle 194 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp 195 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 150 sq.mm 196 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 4 x 6 sq.mm 197 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.2 X 6 sq. mm (19mm) 198 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.3½ X 150 sq. mm (50mm) 199 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.100mm dia 200 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal) 201 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm wide x 50 mm depth x 1.6 mm thickness. 202 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm wide x 50 mm depth x 1.6 mm thickness. 203 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in 1S: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 300 MM Dia 204 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in 1S: 2800 (part 1), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 300 MM Dia 205 Supplying, assembling, lowering and fixing in vertical position in borewell, unplasticized PVC medium well casing (CM) pipe of required dia,conforming to IS: 12818, including required hire and labour charges,fittings & accessories etc. all complete, for all depths, as per direction ofEngineer -in-charge.150 MM Nominal size dia 206 Supplying, assembling, lowering and fixing in vertical position in bore wellunplasticized PVC medium well screen (RMS) pipes with ribs, conformingto IS: 12818, including hire & labour charges, fittings & accessories etc. allcomplete, for all depths, as per direction of Engineer-in-charge. 207 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 208 Development of tube well in accordance with 1S : 2800 (part I) and IS: 11189, to establish maximum rate of useable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, including disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories efc., all as per requirement and direction of Engineer-in-charge. 209 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:150 mm dia 210 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.150 mm clamp 211 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per 1S:2800 (part I). 212 Supply of 3 HPKSB make submersible pump set model BPD 302/4+6UMA1/G 150/6/22 (SD) suitable for tube well capable of pumping clear and cold water free from chemical and directly coupled with KSB electric motor operating of 415 volts suitable for 3 phase 50 cycle A.C. Supply of following duty condition 3 HP 2 stage pipe.A-Discharge of water in LPM 860 Approx size of discharge outlet in 40mm.B-Total Head of pump set 45M 213 Supply and fixing of nylon jali around the slotted pipes complete as required 214 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts,rubber insertions etc. (the tail pieces if required will be paid separately)100 mm diameter 215 Providing laying testing & commisioning of column pipe of class c both heavy duty G.I. pipe conforming to IS 1239 including welding fitting like elbow tees flanges tapers nutes boltes gasketes etc. and fixing the pipe on the wall ceilling with suitable clamp supported frame and painting with tow or more coates of sysnthetic enamel paint ofrequired shades complete as required 50 mm dia nominal bore50mm dia nominal bore 216 S/L of aluminium conductor PVC insulated armoured served sheated cable 1100 voltes grade at a depth of 750 mm below ground level over a cusion of 75 mm thick sand all around and protected with burnt brick on sides and on top . On surface the cable run shall be fixed on M.S CLAMPSE ETC OF SUITABLE etc..16 sqmm 4 core