| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing tiles and rubbish off the premises complete all as specified and directed. |
| 2 | M&L for glazed coloured ceramic tiles of size 300x200x6-7mm thick in vertical surface of walls like skirting/ dado etc , set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles over & including 10mm thick rendering in CM 1:3 on other then fair faces of brick work wall finished rough to fix tiles complete all as specified and directed. |
| 3 | M&L for glazed coloured ceramic tiles of size 450x300x7mm thick in vertical surface of walls, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles over & including 10mm thick rendering in CM 1:3 on other then fair faces of brick work wall finished rough to fix tiles complete all as specified and directed. |
| 4 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square or rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed. |
| 5 | Ditto- all as per Item No.13 above but as in skirting including 10 mm thick rendering in CM 1:3complete all as specified and directed. |
| 6 | Dismantling of Stone slabsof any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete complete all as specified and directed. . |
| 7 | M&L for 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 8 | M&L for mirror polished machine cut kota stone slab flooring 20-22 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing over and including 20 mm thick screed bed in cement mortar (1:4) complete all as specified and as directedNote:- The size of kota stone slab not less than 550mmx550mm (cut size except the location where balanced.) |
| 9 | M&L for mirror polished machine cut kota stone slab flooring 18-22 mm thick over cement screed base in risers of steps, skirting, dado and pillars laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing over and including 15 mm thick screed bed in cement mortar (1:4) complete all as specified and as directed. |
| 10 | M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand: 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified (Payment for providing grooves shall be made separately). |
| 11 | M&L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge |
| 12 | M&L for scraping out loose motar/concrete by chiseling/ wire brushing complete and applying rust removing solution (rebaklene solution) to exposed corroded reinforcement and applying a coat of epoxy primer (Nitozink primer from M/S Fosroc or equivalent as approved by GE) as per manufacture instructions providing and fixing of wire mesh of weight 2.5 Kg per Sqm and apply 25mm average thickness in CM (1:4) mixed with liquid integral water proofing compound (complast \"X\" recommended by the manufacture with guiting machine at a pressure not less than 5Kg/Sqcm finally rendering 10mm thick plaster in CM (1:4) using liquid integral water proofing compound (complast \"X\" 421 i.e. from M/S Fosroc and nitobound AR from M/S Fosroc or equivalent as approved by GE) in the proportion recommended by the manfacture complete all as specifed and directed. |
| 13 | M&L for rendering 5 mm thick on fair faces of brick work or concrete surface of ceiling in cement mortar 1:3finished even & smooth (without using extra cement) complete all as specified and directed |
| 14 | M&L for preperation of newly plastered concrete surface of ceiling & applying three coat of white wash on ceiling surface complete all as specified and directed. |
| 15 | Taking down existing roof treatment of any type and any thickness including mud Phuska/Brick tiles in roofs, plastering, leeping plaster of any thickness cutting & uprooting trees roots/Vegetation growth & removing the debris from the premises upto 500m from the ADRDE land complete all as specified and directed. |
| 16 | M&L for 10mm thick screed bed with cement mortar 1:4 in roof surface including WPC @2% by wt of cement complete all a specified and directed. (Note-Integral water proofing compound shall be measured and paid under this item) |
| 17 | M & L for providing and laying in situ five course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric memberane overroof with following procedure complete all as specified and directed:-(a)Cleaning existing surface properly.(b)Applying First coat of bitumen primer @ 0.30 litre/sqm on prepared surface.(c)2nd & 4th courses of bonding material @ 1.20 kg/sqm, which shallconsist of blown type bitumen of grade 85/25 conforming to IS : 702(d) 3rd course of Laying roofing membraneAPP modified Polymeric membrane using butane torch by torch application with 10cm side laps and 15cm end lap. Physical property of membrane shall be as under :- (i)Membrane thickness minimum-3 mm(ii)Membrane weight minimum- 3.00 Kg/Sqm.(iii)Non woven polyester weight not less than 150 gsm/Sqm. (e) 5th course, the top most layer shall be finished with PCC tiles laid with cement mortar 1:4mixed with 5% integral water proofing compound by weight of cement over a 20 mm layer of cement mortar 1:4 and finished neat complete all as specified and directed ( Note : item of laying PCC tiles with 20 mm thick screed shall be paid separately under respective item). |
| 18 | M&L for 30cm X 30cm X 20mm thick PCC tiles, machine pressed factory made as per IS-1237-1980 (ISI marked) laid over 20mm thick screed bedding in CM (1:4) mixed with water proofing compound @ 5% by weight of cement and tiles joints shall be filled with polymer based cement proof joint filler manufactured by approved company complete all as specified and directed. (Note-Integral water proofing compound deemed to be include in this item) |
| 19 | M&L for cutting grooves in brick parapet walls, 75mm wide and 65mm deep and shaping horizontal face of groove for inserting APP membrane and sealed complete all as specified and directed |
| 20 | M&L for repair of All visible hairline cracks on concrete roof / screed more than 0.50 mm and not giving hollow sound, should be cut and widen in V shape with mechanical cutter in the size (10mm W x 6mm D). Fill cracks withPU sealant / Hybrid Sealant with suitable gun and smoothed with a putty knife or trowel. Allow sealant to cure a minimum (72 Hrs.) 3 days etc complete all as specified & director. |
| 21 | M&L for Remove loose and damaged concrete roof screed in pockets with mechanical cutter. Clean the concrete screed with high pressure water jet to remove dirt and loose particles. Brush apply a bond coat ofPidicrete URP mix in the ratio of 1:1 (URP 1: Cement 1) by volume to make it lump free slurry when applied on in the pre wet surface. Laid to fall roof screed in correct slope and gradient. Mix Dr. Fixit Pidicrete URP 10% by weight of cement in (M20) concrete in ratio of 1:1.5:3 i.e., one bag of 50kg cements: 1.5 times volume of sand: 3 times volume of aggregates: 25L water. Level the repair mortar and finish with trowel. Moist cure should be done for 7days. Air cure screed for 7days, before application of roof top coat coating system etc complete all as specified & directed. |
| 22 | M&L for Apply one coat ofCipoxy 16D primer in the ratio 1:1 spreading at the rate of 0.200 kg-0.250 kg /sqm in complete dry condition where moisture contain below 7% (should be checked with moisture meter)Allow the primer coat to dry for 6 to 8 hours. Apply 1st coat ofRoofseal Classic without dilution spreading at the rate of 0.70/litre/Sq.mt/Coat until all surface is covered. Lay a 45 GSM Fibre glass mesh as a reinforcing material which is incorporated in the coating when the first coat is still in wet condition. Allow the first coat to dry for approximately 4 to 6 hours. Apply the second of chemical with the same application coverage, but in a direction perpendicular to that of the first and second coats. Allow each coat to air cure for a minimum of 4-6 hours after application. Check to see no void surface is left untreated / uncoated.Allow the system to air cure for 7 days minimum etc complete all as specified & directed. |
| 23 | Taking down of cement or cement lime plaster of any description on brick work or stone walls etc including racking out joints, hacking for key scrubbing down with water etc including removal of debris complete all as specified and directed. |
| 24 | M&L for rendering 15 mm thick in cement mortar 1:4 mixed with WPCon fair faces of brick work finishedthe surface even and smooth without using extra cement complete as specified and directed.(Rate of WPC included in this item) |
| 25 | M&L for rendering 15 mm thick in cement mortar 1:6 on other than fair faces of brick wall or concrete surface including finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 26 | M&L for Dubbing out with CM 1:4 average 10mm thick on irregular face of walls/ceiling complete all as specified and directed. |
| 27 | M&L for rendering 5 mm thick on fair faces of brick work or concrete surface of ceiling in cement mortar 1:3finished even & smooth (without using extra cement) complete all as specified and directed |
| 28 | M&L for providing and applying minimum 1mm thick wall care putty over prepared surface including sanding of the putty surface after drying to achieve even and smooth finish for painting complete all as specified and directed. |
| 29 | M&L for preparation of newly plastered wall surfaces and applying Two coat of Cement Base paint including priming coat of primer on new surface complete all as specified and directed.. |
| 30 | M&L for Preparation of newly plastered wall surfaces and applying Two coat of Oil Bound Distemper over a coat of primer using roller complete all as specified and directed |
| 31 | M&L for Preparation of newly plastered ceiling surfaces and applying Two coat of Oil Bound Distemper over a coat of primer using roller complete all as specified and directed |
| 32 | Demolition of un reinforced cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 33 | M & L for water proofing treatment to sunken roof with APP based polymeric membrane, 3 mm thick (minimum), weighing 3.5 Kg/Sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/sqm) shall be applied over and including applying one coat of hot blown bitumin grade 85/25 confirming to IS- 702 @ 1.2 Kg per Sqm over a coat of bituminous primer @ 0.3 litre per sqm surface, application of APP modified membrane joint shall be by torch application. The overlaps shall be minimum 100 mm on the transverse direction and 75 mm longitudinal direction complete all as specified and directed.Make : (i)SUPER THERMOLAY manufactrued by M/s STP limited.(ii) IWL (HYPERPLAS POLYSTER) manufactured by M/s IWL India Ltd.(iii) Pidilite Industries.(iv) M/S Sikka industries WP Shield |
| 34 | M&L for Cement concrete type E-2 1:5:10 (using 40mm thick graded stone aggregates as in foundations, sunken portion filling and mass-concrete complete all as specified and directed. |
| 35 | M & L for providing cement concrete (1:2:4) type B-0 in roof kerbs /lintels upto 1.5m clear spanl cills, steps; seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height, copings, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 36 | M&L for rendering 15mm thick in two layers of 10+5mm in CM 1:4 mixed with Pidi proof 101 LW(+) or Dr fixit or equivalent intergral water proofing admixture:- @ 200ml/bag over two coats of super latex 302 of Dr fixit or equivalent in the ratio (1:4:7) (One part super latex, 4 part water and 7 parts of cement) @ 1.50 Kg of homogenious mixture/sqm in two coats and finish the surface even and smooth (without using extra cement) for external walls complete all as specified and directed.Note:Pidi proof 101 and super latex 302 to be measured and paid separately. |
| 37 | M&L for rendering 15mm thick in two layers of 10+5mm in CM 1:6 mixed with Pidi proof 101 LW(+) or Dr fixit or equivalent intergral water proofing admixture:- @ 200ml/bag over two coats of super latex 302 of Dr fixit or equivalent in the ratio (1:4:7) (One part super latex, 4 part water and 7 parts of cement) @ 1.50 Kg of homogenious mixture/sqm in two coats and finish the surface even and smooth (without using extra cement) for internal walls complete all as specified and directed.Note:Pidi proof 101 and super latex 302 to be measured and paid separately. |
| 38 | Supply only Pidi proof 101 LW (+) |
| 39 | Supply only super latex 302 |
| 40 | M&L for brick work with fly ash bricks, old size, class designation 75, straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar 1:6 including demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work & precast concrete articles complete all as specified and directed. |
| 41 | M&L forcomplete removal of existing treatment on wall/roof projections including facia, cornices, etc by scrapping with mechanical sander (having mechnical vaccum mechanism ) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc by skilled labour complete all as specified and directed by Engr-in-charge. |
| 42 | M&L for providing and applying minimum 1mm thick wall care putty over prepared surface including sanding of the putty surface after drying to achieve even and smooth finish for painintg complete all as specified and directed. |
| 43 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on newly prepared surface of brick (plastered or un-plastered) or concrete surface complete all as specified and directed.Note: Exterior Primer & Acrylic emulsion paint to be applied on wall surfaces with airlessspraymachine (Mechanical means) as approved by Engr-in-Charge .Apply 2nd coat after 1st coat is dry approximately 6-8 hrs between two coats. |
| 44 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm onold prepared surfaces of brick (plastered or un-plastered) or concrete surface complete all as specified and directed.Note: Exterior Primer & Acrylic emulsion paint to be applied on wall surfaces with airlessspraymachine (Mechanical means) as approved by Engr-in-Charge .Apply 2nd coat after 1st coat is dry approximately 6-8 hrs between two coats. |
| 45 | M&L for preperation of old decorated plastered suface of walls & applying One coat of Cement Base paint complete all as specified & directed. |
| 46 | M&L for preperation of old decorated plastered suface of walls & applying Two coat of Cement Base paint after removal of existing treatment complete all as specified & directed. |
| 47 | M&L for preperation of old decorated plastered surface of walls & applying Two coat of Oil Bound Distemper using roller after removal of existing treatment complete all as specified & directed. |
| 48 | M&L for preperation of old decorated plastered surface of walls & applying One coat of Oil Bound Distemper using roller after removal of existing treatment complete all as specified & directed. |
| 49 | M&L for Preparation of old decorated surfaces of ceiling and applying Two coats of White Wash complete all as specified & directed. . |
| 50 | M&L for preparation of old treated wooden or wood based surfaces of any description exceeding 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 51 | M&L for preparation of old treated steel surface of any description exceeding 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 52 | M&L for 75mm thick cement concrete type C2 1:3:6 (using 40 mm stone graded crushed stone aggregate) as in plinth protection surface finished even and fair including forming construction (dummy) joints 6 mm wide & 10 mm deep and filled with filler at an interval not exceeding 3 metre and at change of direction complete all as specified and directed. |
| 53 | M&L for Writing letters or figures (Block, Roman,Italic or Indian) n exc 30cm high complete all as specified and directed. |
| 54 | Demolition and breaking up rain water pipe(PVC, AC, or re-inforced concrete ) of size 100mm bore complete all as specified and directed. |
| 55 | S&F of PVC SWR pipes 110mm bore single socketed in any length with rubber ging joints fixed to wall complete all as specified and directed. |
| 56 | Fixing only PVC SWR pipes 100mm bore single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed. |
| 57 | S&F PVC (SWR) vent cowl 110mm bore complete all as specified and directed. |
| 58 | S&F110 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 59 | S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, includingbolts and nuts andsecuring ends of stays to wall or roof suitable for 100mm bore pipecomplete all as specified and directed. |
| 60 | Removal of plants/trees//Shrubs from roof tops/sides, external walls of bldg, chajjas, wall junctions of rains water/CI soil /waste pipe junctions including taking out the roots entered in wall/slab surfaces and making good the disturbed surface using (1:2:4) type B-O or cement mortar (1:2)including repairing the GI/CI/PVC pipe joints which were damged during cutting/taking out process to match with the existing and finishing the disturbed surface tomatch with existing including necessary scaffolding/staging upto a height of 15 .00 M from the ground level complete all as specified and directed. |
| 61 | M&L for preparation of old painted surfaces of steel/iron/CI pipes of any description exceeding 10cm width or girth and applying one coat of black bituminous paint complete all as specified and directed. |
| 62 | Hacking out old broken glass any thickness size,quality or description from wooden frame glazed with putty or fixed with beads complete all as specified and directed. |
| 63 | Supply and fixing for 3mm thick ordinary sheet glass of ordinary quality and glazing with aluminium rubber brush strip/fillet or beads, nut bolts or with rivets/pins or oil putty in square exc 0.5 Sqm in each pane complete all as specified and directed. |
| 64 | S&F 3 mm thick figured glass pin head type and glazing with oil putty or wooden beads in squares n exc 0.50 sqm each pane complete all as specified and directed. |
| 65 | S&F in repair wire cloth 0.56mm nominal dia of wire and avg width of aperature 1.18mm complete allas specified and directed.Note for above Items :(i) Any CI/AC/PVC pipes or pipefitting damaged during the process of work shall be replaced by new one without any extra cost to the department. The decision of the GE in this regard shall be final and binding.(ii)The debris including vegetation plant/trees shall be disposed off to a distance exc 0.5 Km and n exc 1.00 Km all as directed by Engineer -in -charge.(iii) For deciding the girth of the plant/tree the height shall be taken at 30cm above the slab/wall. (iv) The labour employed by the contractor for carring out the work shall be provided with safety equipment and quoted rate shall be deemed to include the same. (v) All window, joineries, mirrors, fittings, doors etc, shall be covered before painting the surface and the same shall be cleaned including cleaning of floor as directed by the the Engineer-in-charge.(vi) Work to be carried out upto 15.00m height with necessary MS scaffolding including all other safety precautions and quoted rate shall be deemed to include the same. |
| 66 | S&F in repair for solar cat eye aluminum alloy shall (100% water proofing design) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/0.3 watt one NI-ed rechargeable battery (1.2V/1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc. all as specified and directed |
| 67 | M&L for preparation of existing bituminous surfaces, removing, dust, dirt grease and other foreign matters etc to receive thermo plastic (Reflective) line marking having 2.0 mm thickness (average) of uniform surface finish conforming to BS3262 (Part 1) 1989 read in conjunction with the MORTHspecification 803 clause 4.2.2 on bituminous surfaces in white/yellow colour and super imposed with glass beads confirming to BS 6088 read in conjuction with and MORTH specification 803 clause 4.3.3 complete all as specified and directed.Note - MORTH specification 803 shall be followed strictly for execution of work&suitable machine shall beused for the marking as approved by the GE. Shape & size/ patterns ofmarking shall be as approved by the GE. |
| 68 | S&F in repair road studs made of polycarbonate moulded plastic body of single shank of size 100x100x26mm of min weight of 140gms with electronically welded micro prismatic lense on both side of colour- Yellow/Red/Amber for maximum retro reflection in wet and dry conditions and to be fixed on road with shank as road sign complete all as per manufacturer instructions and specified as directed. |
| 69 | S&F for road side convex mirror of size 800mm dia(material polycarbonate) mountedon MS pipe of 2.10mtr long and dia of pipe is 80 mm embedded with PCCtype B-1,1:2:4 (20mm graded aggregate) including RFR, removal andtwo coat of synthetic enamel paint over a coat of zinc chrome primer in MS pipe including necessary excavation and earth work in any type of soil for fixing and embeding the delineator on ground with hold fast using PCC (1:2:4) type B1(using 20mm graded stone agregate) (minimum PCC block size 300mmx300mmx300mm) for proper grouting complete. |
| 70 | M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 71 | M&L for preparation of new concrete surface and applying two coats of synthetic enamel paint over a priming paint plaster coat complete all as specified and directed by Engineer-in-charge. |
| 72 | M&L for removing old enamel paint and cleaning with scrapers, any number of coats any width or girth and applying two coats of synthetic enamel paint over on brick/concrete/AC surface complete all as specified and directed by Engineer-in-charge. |
| 73 | S&F in repair delineators made out of 75 mm dia, heavy duty mild steel powder coated pipe of length 1200 mm with ABS round body fitted with 2 Nos 100 mm dia highly reflective reflectors made out of PMMA mounted on it with anti rust and anti theft steel net having weight approx 1760grms, Including necessary excavation and earth work in any type of soil for fixing and embeding the delineator on ground with hold fast using PCC (1:2:4) type B1(using 20mm graded stone agregate) (minimum PCC block size 300mmx300mmx300mm) for proper grouting complete all as specified and directed. |
| 74 | Surface dressing n exc 15 cm deep & averaging 7.5 cm deep & getting out soft/loose soil. Note: To be executed in selected streches as per requirement and directed. |
| 75 | M&L for repair to pot holesexc 30mm depth and n.exc 1 Sqm each including sweeping free from dust and mud, or water, scoring sunken surface in roads, paths, etc cutting around edges to at least 25mm in depth and making good by applying tack coat @ 5 Kgs per 10 Sqm, putting in premixed bituminous macadam, well rammed and sealed with paving bitumen VG-30 grade@ 9.8 Kgs per 10 Sqm blended with 0.09 cum of stone chipping of size 6.3mm and again well rolled with 8 to 12 tonne power roller (Iincluding supply of pre-mixed macadam, binder and chipping) complete all as specified and directed. |
| 76 | M&L preparing existing black top surface or bituminous macadam surfaces by brushing with wire brushes for removing caked mud etcsweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all loose dirt etc on back top / concrete surfaces then applying evenly a priming / tack coat with paving bituminous primer VG-10 penetration over the prepared surface by mechanical sprayer@ 5 Kgs/10 Sqm of surface area complete all as specified and directed. |
| 77 | M&L applying bituminous premix asphaltic dense concrete (DAC), 30mm thick (consolidated thickness) with 6% binder content of paving bitumen any penetration VG-30 grade by weight of total mix including cement filler, on surfaces rolled compacted with using 8 to 12 tonne capacity power roller to achieve the required compactness, camber and gradent mixed in hot mix plant using design mix and laid by mechanical paver finisher complete all as specified and directed. |
| 78 | M&L premix bituminous macadam laid, rolled (with using 8-12 tonne power roller) and compacted to required gradient and camber in n.exc 75mm thickness (consolidated thickness) with binder content of 4% by weight of total mix, content of paving bitumen VG-30, mixed in hot mix plant and laid by mechnical paver finisher complete all as specified and directed. |