| 1 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings Complete all as specified and as directed by Engr-in-charge. |
| 2 | M& L Prepainted galvanume aluminium zine coating GI based corrugated steel sheeting 0.50 mm thick any colour having tensile strenght 550Mpa in roof coverings fixed with self tapping screws Complete all as specified and as directed by Engr-in-charge. |
| 3 | M & L Prepainted galvanume aluminium zine coating GI based plain steel sheeting 0.50 mm thick any colour having tensile strenght 550Mpa in roof coverings fixed with self tapping screws Complete all as specified and as directed by Engr-in-charge. |
| 4 | Dismantling of wall andceiling boards (fibre, pulp, insulationetc.) or insulation boards/ slabs/ blankets, any thickness including cover filletscomplete all as specified and as directed . |
| 5 | S&FGl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mmthick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clipsacross the intermediate channel at 457 mm centre to centre. size of grid 605mm X605mm complete all as specified and directed. |
| 6 | S&F 6 mm thick non asbestos fiber cement building board (Designer ceiling board), fixed to aluminium or MS galvanised snap grid frame work with screw in ceiling complete all as specified. |
| 7 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc complete all as specified and directed. |
| 8 | M&L for precast cement concrete 1:3:6 type C1 (Using 20 mm graded granite stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed. |
| 9 | Taking down cement plaster any description from stone wall, brick wall, parapets including raking out joints hacking for key and scrubbing down with water etc complete all as specified . |
| 10 | M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM1:4 and finish the surface even and smooth without using extra cementall as spd anddirected. |
| 11 | Demolition ofcement concrete in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level) complete all as specified and directed by engr in charge. |
| 12 | M&L for 50mm thick cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing & finished the surface even & fair all as specified. |
| 13 | M & L for machine cut Kota stone slab flooring 20 to 25 mm thick over Screed bed or bedding layer of cement mortar 1:6, 20 mm thick base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed |
| 14 | M & L for Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid overincluding 15mm thick rendering as in backing coat in CM 1:4and jointed withgrey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed |
| 15 | M&L 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm gradedstone aggregate) in plinth protections, finished even and smooth w/o using extra cementincluding necessary joints all as specified and directed |
| 16 | Taking down Chowkats or frames not exceeding 1.5 Sq. M each (Without taking off shutters from the frames) complete all as specified and directed. |
| 17 | Supply and fix steel windows with side hungshutters including box type hinges with steel handle and steel peg stay complete with glazing bars for glazed shutters, dovetailed or welded complete all as directed by Engineer-in-charge. |
| 18 | Supply & fixing for galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm & fixed with tinned tacks, or galvanised wire staples. & directed. |
| 19 | S&F plain sheet glass of 4 mm thick in squares not exceeding 0.50 Sqm in each pane with oil putty and clips complete all as directed. |
| 20 | Dismantling structural steel work including doors, gates but excluding framed of trussesor similar work etc. complete all as specified and as directed. |
| 21 | Material and labour for framed work as in steel doors of gates of angles or other section with gusset plates, rails, braces, etc. Complete,conforming to Fe-410W (Gde-E-250) quality \"B\", drilled for fixing of steel sheeting or other covering. doors etc to be prepared hanging or sliding with and including either hooks and hinges or steelhangingdoor fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing completecomplete all as specified and as directed. |
| 22 | Material and labour for mild steel, plain, black sheet 1.60mm thick in steel gates, wall cladding and similar works, cut to size, holes punched, includinground headed screws clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams including bending or turining up, mitred angles etc, as requiredcomplete all as specified and as directed. |
| 23 | M&L for 100mm thick cement concrete 1:2:4 type B-2 using (40 mm graded stone aggregate) in two layers and laid in alternate bays as inhard standing & finished the surface even & fair without using extra cement complete all as specified and directed. |
| 24 | Forming Construction joint 30mm deep x10mm wide including filledwith sealing compound (1part of bitumen and 3 part of sand) and complete all as specified and directed. |
| 25 | M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing & finished the surface even & fair all as specified. |
| 26 | M & L for 15mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough complete all as specified and directed. |
| 27 | M&L for chequered cement concrete tiles25CM x25CMx25MMthick with grey cement and pigment set and jointed in neat cement slurry and pointed in white or coloured cementcomplete all as specified. |
| 28 | M & L for providing cement concrete cas in situ 1:2:4, type B1 (using 20mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edge including use of formwork complete all as specified and directed by engr in charge. |
| 29 | M&L for preparing new plastered surfaces and applying two coats of cement base paint on surfaces of walls over one coat of alkali resistant primer complete all as spd and as directed . |
| 30 | M & L forold decorative surfaces, preparation of wall and applying two coats of cement base paint complete all as specified and as directed. |
| 31 | M&L for prepare old decorative surface and applying two coats of oil bound distemper on walls etc complete all as specified and as directed |
| 32 | M & L for preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat synthetic enamel paintcomplete all as specified. |
| 33 | Ditto- all as per item 32 above but one coat of synthetic enamel paint on old steel surfaces of any description complete all as specified and directed. |
| 34 | M&L for walling of random rubble masonry uncourced well bonded bedded and solidly hearted built in CM 1:6complete all as specified and directed by Engr-in-Charge. |
| 35 | M & L forcementconcrete type B-1 1:2:4 (using 20 mm graded stone aggregate), as incopings,lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 36 | M& L for two coats of preparation of new surfaces of wall and applyinhg two coats of Cement based paint over a coat of primercomplete all as specified and as directed. |
| 37 | M&L for mild steel work as in posts or struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc ,and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 38 | Dismantling offencing wire mesh, anytype any description from RCC/steel fencing post complete all as specified & directed. |
| 39 | S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard tails straining bolts, including, securingor tying at crossing with and provision of galvanised mild steel wire, staples or steel pins etc as directed (each line wire to be measured) |
| 40 | Taking down carefully copper/aluminium point wiring from existing points (light, fan, socket or power) alongwith compete fittings such as switches ,ceiling rose, pendent holder, sketch fitting & regulator etc. includingmaking good to the disturbed surfaces of wall, roofand floor etc. to match with the existing surfaces complete all as specified and directed by Engineer-in-Charge. |
| 41 | M&L for point wiring using approved colour coding as per IS with using approved colour coding as per IS 1.5 Sqmm multistranded,1100 volt grade copper conductor cable of PVC insulated and unsheathed type alongwith 1.5 Sqmm PVC insulatedstranded copper conductor cable for continuous earthing in & incl PVC Casing capeing/ PVC condut as per directedwith accessories having ISI mark fixed on wall surfaces / ceilingincluding provision PCV Box on top for fixing switches sockets((separate conduits/caring & capings for individual conduit casing caping circuits) etc. all as specified for one light point/ fan /Bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge. |
| 42 | All as per Srl item No 41 here-in-before but controlled with one 5 pin socket outlet 5 Amp on same board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 43 | All as per Srl item No 41 here-in-before but controlled with one 5 pin socket outlet 5 Amp, independent board withcable 1.5 sqmm including provision of 1.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 44 | All as per Srl item No 41 here-in-before but controlled with one 5 pin socket outlet 15 Amp, independent board withcable 2.5 sqmm including provision of 2.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 45 | Supply and fix in replacement ofswitch piano type 15 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 46 | Supply and fix in replacement of socket outlet 5 pin 15 Amp 2-in-one230 Volt flush typecomplete all as specified and directed by Engineer -in-Charge. |
| 47 | Supply and fix in replacement of socket outlet 5 pin 5 Amp 2-in-one230 Volt flush typecomplete all as specified and directed by Engineer -in-Charge. |
| 48 | Supply and fix in replacement of switch piano type 5 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 49 | Supply and fix in replacement of Ceiling rose, 3 terminal with ISI markall as specified and directed by Engr-In-Charge. |
| 50 | Supply and fix in replacement of surface & wall mounted LED 20W tube light fitting 4 feet with high quality material and design, extruded aluminium housing enhances safety. High quality PC diffuser, reliable and robust housing structure, maximize the endurance over the life time slim integrated design, easy to install efficacy 125 limen/ watt all accessories as specified and directed by Engg-in-Charge. |
| 51 | Supply and fix in replacement of lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings. |
| 52 | Supply and fix in replacement ofLED lamp 12W energy saving upto 80%, BEE ratedwith all accessories all as specified and directed by Engg-in-Charge. |
| 53 | Supply and fix in replacement of 9 watts LED backup lamp of 4 hours backup, with auto switch on mechanism in case of power failure, works as regular 9w lamp in normal mode and a 4w lamp in backup mode all as specified and directed by Engg-in-Charge. |
| 54 | Supply and fix in replacement of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc.all as specified and directed by Engg-in-Charge. |
| 55 | Supply and fix in replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 56 | Supply and fix in replacement of bulk head light with 10 W LED Lamp complete. |
| 57 | Supply and fix in replacement ofsheet metal enclosure double door for DBs single pole and neutral for 12 way 240 volt complete all as specified and directed by Engineer-in-Charge. |
| 58 | Supply and fix in replacement of MCBSPN 63Amp,10 KA all as specified and directed by Engineer-in-Charge |
| 59 | Supply and fix in replacement of MCB SP 16 Amp, 10 KA. all as specified and directed by Engineer-in-Charge. |
| 60 | Supply and fix in replacement of ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amps. |
| 61 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the ground level with top edge of the plate not less than 1.5 mtr below the normal ground level connected to the galvanised earth wire 4 mm dia by means of bolts, nuts hook nuts and washers of galvanization of steel all as shown in electrical plate no 3connected to earthing testing pointall as specified or indicated including testing on completions. |
| 62 | Supplying and fixing 1100 volts grade heavy duty, XLPE aluminium cable, in service connections,twin core 10 Sqmm Circural cabel, complete all as per specified and directed by Engineer-in-Charge. |
| 63 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in hard/dense soil for laying/jointing kit/repair of cable and erection of poles complete all as specified and directed |
| 64 | Returning and filling in two parts (i) using riddled soil obtained from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil complete all as specified and directed. Note- (i)Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS - 1255-1983 and refilling in trenches as in cable cushioning. (ii) Surplus soil if any shall not be removed but left proud over the trench |
| 65 | Supply and lay well burntclass ‘B’ bricks as mechanicalprotection to under ground cables laying with length of the bricks equal to the width of the trench all as specified and directed |
| 66 | M&L for taking out old unserviceable and supply, laying, fixing Double walled corrugated HDPE duct pipe of 25 mm outer dia confirming to IS-14930 (Part-II) of approved colour with fittings for cable protection complete all as directed. |
| 67 | Schedule of Credit |