| Sl. No. | Item Description |
| 1 | CONSTRUCTION OF FRM CENTRE BUILDING |
| 2 | Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and rammingof bottomsand disposalof surplusexcavated earthas directedby theEngineer i/c with in a lead of 50m. |
| 3 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form-work,in foundation and floors. |
| 4 | Sand filling in plinth under floors includingwatering, ramming,consolidating and dressing complete including lead up to 50m and lift upto 1.5m and including costof sand. |
| 5 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measuredasperI.S.6313(PartII1981)Alderineemulsifiableconcentrateorany other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary&foundation5literspersqm.(2)Backfillinimmediatecontactwith foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatmentjunctionofwallandthefloor7.5liters/sqm(5)Treatmentofsoil alongexternalperimeterofbuilding7.5liters/sqm.(6)Treatmentofsoilunder apronalongexternalperimter5liters/sqm.(Aspermanufacturer\"sstandarddilution) |
| 6 | R.C.C.workwithcementapprovedcoarsesandand20mm.guageapproved stonegritimtheproportionof1:1.5:3inlintelsofdoorsandwindowsexcluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wireandincludingnecessarycenteringandshutteringetc.andalsoincluding supplyofallmaterials,labourandtoolsandplantsetc,requiredforproper completion of the works. strength of the concrete shall not beless than M-200. for thelighterbeams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) |
| 7 | Sameasabovebutforthe lighterbeami.e.havingspansupto6m.(Using 1:1.5:3 Mix concrete) |
| 8 | As in item 6 abovebut inR.C.C. Raft foundation and footing withapproved stone ballast.(Using1:1.5:3Mix concrete) |
| 9 | Asinitem6above butin Columnwith approvedstoneballast.(Using 1:1.5:3 Mix concrete). |
| 10 | ClassM-150brickworkin1:6cementcoarsesand(of2.25finenessmodulus)mortarin foundation&plinthincludingsupply ofallmaterials,labour,tools and plants etc. required for proper completion of the work. |
| 11 | Class-150 brick work in 1:6 cementand Coarse sandmortar in Super structureincluding supply of all materials, labour tools and plants, etc. required for proper completetion of the work. |
| 12 | Class-150 HALFbrick work in1:4 cementand COARSEsandmortar in SUPERSTRUCTUREincludingsupplyofallmaterials,labourtoolsandplants,etc. Required for proper completetion of the work. |
| 13 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work(whennotincludedinoverallrates)wroughttorequiredshapeas necessaryincludingbendingforpropercompletionoftheworkandincluding supplyofsteelitswastagebendhooksandauthorisedoverlappingshallbemeasured upto floor two level. |
| 14 | 12 mm cement plaster in single coat on rough side of single or half brick wall for interiorplasteringuptofloortwolevelincludinginternalroundedanglesnot exceeding80mmingirthandfinshedevenandsmooth.(1)1cement:6finesand. |
| 15 | 15mm Cement plaster in single coat of Rough side of single of half brick wall for exterior plastering upto floor two level including internal rounded angles chamfers, and/orroundedanglesnotexceeding80mm.Ingirthandfinishedevenandsmooth No. extra for mixing any additive. 1 cement : 6 fine sand |
| 16 | Cementconcreteflooring1:2:4(1cement:2coarsesand:4gradedstone aggregate12-20mmnominalsizelaidinonelayerneatcement(40mmthickfloor). |
| 17 | P/F Glass strip 5mm thick 35mm Wide |
| 18 | Steelworkinbuiltuptubular(round,squareorrectangularhollowtubesetc.) trussesetc.,includingcutting,hoisting,fixinginpositionandapplyingapriming coatofapproved steelprimer, includingwelding andbolted withspecial shaped washers etc. complete.Electric resistance or induction butt welded tubes |
| 19 | ProvidingcorrugatedG.S.sheetroofingincludingvertical/curvedsurfacefixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen andG.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheetscomplete(uptoanypitchinhorizontal/verticalorcurvedsurfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shapewhereverrequired.0.63mmthickwithzinccoatingnotlessthan275gm/m² |
| 20 | Painting two coat over priming coat (but includingcost ofpriming coat)on steel andothermetalsurfacesupto10cm.widthorgirthorsmallarticlesnot exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi- glossapcolitesuperlac,DULUXspecifiedbrushingtogiveanevenshadeand includingcleaningthesurfaceofalldirt,dustandotherforeignmattersand paperingand stopingincluding costof allmaterials, labour tools andplants etc. required for proper completion of the work. For Steel Surface. |
| 21 | Painting two coat over priming coat (but includingcost ofpriming coat)on steel andothermetalsurfacesupto10cm.widthorgirthorsmallarticlesnot exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi- glossapcolitesuperlac,DULUXspecifiedbrushingtogiveanevenshadeand includingcleaningthesurfaceofalldirt,dustandotherforeignmattersand paperingand stopingincluding costof allmaterials, labour tools andplants etc. required for proper completion of the work. For Wooden Surface. |
| 22 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work(whennotincludedinoverallrates)wroughttorequiredshapeas necessaryincludingbendingforpropercompletionoftheworkandincluding supplyofsteelitswastagebendhooksandauthorisedoverlappingshallbemeasured upto floor two level. |
| 23 | ProvidingandfixingG.I.chainlinkfabric fencingof requiredwidth inmesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wireof dia 4 mm |
| 24 | M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work. Angle iron doorchaukhats 40*40*5 |
| 25 | Fixing of Door, windows/ventilators chaukhats in position. (a) Door chaukhats |
| 26 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 27 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters(a) 30 mm thick including ISI marked Stainless Steel butt hinges with necessaryscrews single leaf |
| 28 | Providing and fixing S/S sliding door bolts, ISI marked anodised (anodic coating notlessthangradeAC10asperIS:1868),transparentordyedtorequiredcolour or shade, with nuts and screws etc. complete : 250x16 mm |
| 29 | ProvidingandfixingS/Stowerbolts,ISImarked,anodised(anodiccoatingnot less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :(a) 250 mm x 10mm |
| 30 | Providing and fixing S/S handles, ISI marked, anodised (anodic coating not lessthangradeAC10asperIS:1868)transparentordyedtorequiredcolouror shade, with necessary screws etc. complete : 125mm |
| 31 | Finishingwallswith water-proofing on cementpaint of approvedmakesuch as super snowcem, durrocem, robiacem, guttucem supercem qualityandof required shade on undecorated wall surfaces (two coat) overone and including one coat whiteafterthoroughlybrushingthesurfacetopowderedmaterialsincluding curing and cost of all materials. |
| 32 | ProvidingandfixingonwallfaceunplasticisedRigidPVCrainwaterpipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gapfor thermalexpansion, (i)Single socketedpipes. 75mm diameter |
| 33 | Supply and fixing of recess mounting CFL down light speciall designed for SATINFINISH aluminium reflector, copper ballast suitable for & with 2 Nos. 18 watt CFL complete in all respect. |
| 34 | Supply and burying of 40mm dia x 4.5meters long G.I. pipe, vertically for earthing having12mmdia.Holesspaced75mmapartdrilledupto2metersfromthe bottomcompletewithearthingleadofno6to8SWGGIwireinGIpipeupto appron (and from appron to switch board the cost of G.I. pipe and G.I. wire will be extra)uptoswitchboard,30cm.squareC.I.box withhingedcover,masonary enclosue, funnel at top, alternate layers/of charcoal/ coke and salt at least 150mmthick alround etc. complete in all respects. |
| 35 | Supply&fixingofonenumber8SWGG.I.wirein15mmdia.G.I.pipe for earthing,laidinwalldulyconcealedincludingthecostofcement,sand,labour,T&P other material required for proper completion of the wirk as directed at site. |
| 36 | Supply and fixing of 240 volts \"L\" series miniature circuit breaker 9 K.A / 10 K.A.inexisting MCB, DB complete with connections as required. 5 - 32 amps. |
| 37 | Supplyfixingand makingconnection offollowing FPMCBScomplete inallrespects as per direction and satisfaction of engineer-in-charge. |
| 38 | Supplyandfixingofflush/surfacemountingdistributionboardscompleteinallrespects. 8 Way SPN |
| 39 | Supply and fixing Single Pole MCBS Blanking Plate complete in all respects. |
| 40 | Providing and Laying unplastisized rigid PVC pipe conforming to IS:13592 type A including jointing, cuttingand making good the walls & floors as per requirement.150mm |
| 41 | Supply and erection of AC 1200mm Sweep, 230/250 Volts, 50 Hz ceilling fan withregulater standar down rod, blades including connection etc. complete as required |
| 42 | ADD EXTRA FOR 6 WATER TAPS IN WASHING UNIT |
| 43 | construction of Fencing Wall |
| 44 | Excavation for all types and sizes of foundations, trenches and drains of for any other purpose including disposal of excavated stuff up to 1.5m lift and lead up to 50m (At least 5m away from the excavated area), including dressing and leavingof pits. |
| 45 | Providing and laying nominal mix cement concrete with crushed stone aggregate usingconcretemixerinfoundation,plinthandatgroundlevelexcludingcostof formwork.1:4:8(1cement:4coarsesand:8gradedstoneaggregate40mmnominal size) |
| 46 | Brick work with modular fly-ash lime bricks (FLAG Bricks) confirming to IS: 12894-2002 of class designation35 in foundation and plinth in: |
| 47 | Providing and laying dampproofcourse40mmthickwithDSR4.10-cement concrete 1:2:4 (1 cement : 2 coarse sand (zone- III): 4 graded stone aggregate. |
| 48 | Providingandplacinginpositionangleironpostandstrutofrequiredsize includingbottomtobesplitandbentatrightangleinoppositedirectionfor requiredlengthanddrillingholesupto10mmdia.asperrequirementincluding primingcoatwithredoxidezincchromateprimerandplacingthepost/strutincement concrete block. |
| 49 | Providingandlayingnominalmixplaincementconcretewithcrushedstone aggregateusingconcretemixerinallworks.1:2:4(1cement:2coarsesand4graded stone aggregate 20mm nominal size) |
| 50 | 12mm thick cement plaster of mix: In cement Mortar 1:6 (1 cement :6 fine sand) |
| 51 | 12mm thick cement plaster of mix: In Cement mortar 1:6 (1 cement:6 fine sand) |
| 52 | Finishing walls with water proofing cement paint of required shade to give an evenshade. On New work (Two or more coats [email protected]/10sqm) |
| 53 | INTERLOCKING TILE |
| 54 | Excavation infoundation inordinary Soil ( Loam clay or sand ) including lift upto1.5mleadupto30.0m &includingfillingwatering andramming ofexcavated earth into the space between the building & sides offoundation trenches or into the plinth and removal& disposal surplus earthas directed by the engineer I/C within a lead of 30 m.from foundation trenches. |
| 55 | Class-150brickworkin 1:6 cement andcoarse sand mortar in foundation and plinth including supply of all materials, labour tools and plants, etc. Required forproper completetion of the work. |
| 56 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominalsize) |
| 57 | Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8graded stoneballast40mm.nominalsize)includingsupply ofallmaterials,labour and T&Petc.requiredforpropercompletionoftheworkandcuringcomplete,alsoincluding cost of formwork in foundation. |
| 58 | Sand filling in plinth under floors includingwatering, ramming,consolidating and dressing complete including lead up to 50m and lift upto 1.5m and including costof sand. |
| 59 | 12mmcementplasteronroughsideofsingleorhalfbrickwallofmix:1:6(1 cement: 6 coarse sand |
| 60 | ProvidingandlayingfactorymadechamferededgeCementConcretepaver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness&size/shape,madebytablevibratorymethodusingPU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compactingandproperembedding/layingofinterlockingpaverblocksintothe sand bedding layer through vibratory compaction by using plate vibrator, filling the jointswithsandandcuttingofpaverblocksasperrequiredsizeandpattern, finishingandsweepingextrasand.completeallasperdirectionofEngineer-in- Charge. 60mmthick cementconcrete paverblock ofM-35 gradewith approved colour, design & pattern. |
| 61 | TOILET BLOCK |
| 62 | Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meterandleadupto30meterandincludingfilling,wateringandrammingof excavatedearthintothetrenchesorintothespacebetweenthebuildingand sidesoffoundationtrenchesorintotheplinthandremovaland disposalof sur- plusearthasdirectedbytheEngineerinchargeuptoadistanceof30metersfrom the foundation trenches. |
| 63 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & Prtcrequiredforpropercompletionoftheworkandcuringcompletealsoincluding cost of formwork in foundation & floors. |
| 64 | Sand filling in plinth including supply ofnecessaryquantityofsandfroma distancenotexceeding8kms.fromthesiteofworkandincludingwatering, dressingetcratetoincludecostofallmaterialslabourT&Petcrequiredforproper completion of work. |
| 65 | (4)Treatmentjunctionofwallandthefloor7.5liters/sqm(5)Treatmentofsoil alongexternalperimeterofbuilding7.5liters/sqm(6)Treatmentofsoilunder apronalongexternalperimter5liters/sqm.(Aspermanufacturer\"sstandarddilution) |
| 66 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and alsoincluding supply of all materials, labour and tools and plants etc, required for proper completion of the works.includingcostofbindingwire.Therateexcludesmakingofdripcourse which shall be paid extra. Ground Floor |
| 67 | As in item no. 6 above but for slabs (Using 1:1.5:3 Mix concrete) Ground Floor |
| 68 | M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus)mortarin foundation&plinthincludingsupplyofallmaterials,labourand T & P etc required for proper completion of the work. |
| 69 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominalsize) |
| 70 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approvedqualityusing1.7kgpersquaremetreondampproofcourseafter cleaning the surface with brushes and finally with a piece of cloth lightly soaked inkerosene oil. |
| 71 | SameasinitemNo.11above but insuper-structureaboveplinthlevelupto floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand). Ground Floor |
| 72 | Same as above item no. but in1:4 cement and coarse sand mortar insuperstructure for wall thickness 12 cms & below brick work. Ground Floor |
| 73 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work(whennotincludedinoverallrates)wroughttorequiredshapeas necessaryincludingbendingforpropercompletionoftheworkandincluding supplyofsteelitswastagebendhooksandauthorisedoverlappingshallbemeasured upto floor two level.Ground Floor |
| 74 | 15mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M. |
| 75 | 12 mm cement plaster in single coat on rough side of single or half brick wall for interiorplasteringuptofloortwolevelincludinginternalroundedanglesnot exceeding80mmingirthandfinshedevenandsmooth.(1)1cement:6finesand Ground Floor |
| 76 | 12mmcementplasterinsinglecoatonfairsideofsingleorhalfbrickwallfor exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 finesand. GroundFloor |
| 77 | Making grooves 10 to 12 X 12mm and upto 25 X 15 mm deep in plaster of thewalls or in ceiling vertically or horizontally as required. |
| 78 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to bespecifiedbythemanufacturer)of1stqualityconformingtoIS:15622of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20mmthickcementmortar1:4(1Cement:4Coarsesand),jointingwithgrey [email protected]/sqmincludingpointingthejointswithwhitecementandmatching pigment etc., complete.. Ground Floor |
| 79 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3(1cement:3coarsesand)[email protected] per sqm, including pointing in white cement mixed with pigment of matchingshade complete. Ground Floor |
| 80 | Cementconcreteflooring1:2:4(1cement:2coarsesand:4gradedstone aggregate12-20mmnominalsizelaidinonelayerneatcement(25mmthickfloor). |
| 81 | ProvidingandfixingofFlushdoorscommercialqualityconformingtoI.S.2202 part-I(1983) includingfixingofwoodencleatsandstoppersandincludingfixing and adjustment of hinges, bolts locks, handles spring fitting with necessary screwsto be supplied departmentally. 30 mm thick |
| 82 | M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastageetcandfixingrequiredforpropercompletionofthework.Providing&fixing of hold fast for chaukhatsof doors and windows. |
| 83 | Providing & fixing of door / windows grill. |
| 84 | Z-Section steel windows (openable) |
| 85 | Angle iron door chaukhats 40*40*5 |
| 86 | Fixing of Door, windows/ventilators chaukhats in position. |
| 87 | (a) Door chaukhats |
| 88 | (c) Ventilator chaukhats |
| 89 | Distempering (Two coat) with oil bounddistemperofapprovedbrand and manufacture & of required shadeon undecorated wall surface to give an even shade over & including a priming coat with cement primer of approvedbrand&manufacturesuchasBerger,J&N,Shalimar,Asianpaints after thoroughly brushing the surface free from mortar droppings & other foreign matters&alsoincludingpreparingthesurfaceevenwithplasterofparisor approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface) |
| 90 | FinishingwallswithAcrylicsmoothexteriorpaintofrequiredshade: -New work(Two or more coat applied @ 1.67 Ltr./10 Sqmover andincluding basecoat of water proofing cement paint applied @ 2.20 kg/10 Sqm. |
| 91 | Distempering (Two coat) with oil bounddistemperofapprovedbrand and manufacture & of required shadeon undecorated wall surface to give an even shade over & including a priming coat with cement primer of approvedbrand&manufacturesuchasBerger,J&N,Shalimar,Asianpaints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing thesurface even with plaster of paris or approved synthetic material & sand paperedsmooth including cost ofall materials. |
| 92 | Providingandapplyingwhitecement based putty of average thickness 1 mm, ofapprovedbrandandmanufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 93 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 94 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coatingnotlessthangradeAC10asperIS:1868)transparentordyedto required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
| 95 | Providingandfixingstainlesssteeltowerbolts(barrel type) with necessaryscrewsetc. complete |
| 96 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm. |
| 97 | (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed andspecified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 98 | Painting two coat over priming coat (but includingcost ofpriming coat)on steel andothermetalsurfacesupto10cm.widthorgirthorsmallarticlesnot exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi- glossapcolitesuperlac,DULUXspecifiedbrushingtogiveanevenshadeand includingcleaningthesurfaceofalldirt,dustandotherforeignmattersand paperingand stopingincluding costof allmaterials, labour tools andplants etc.required for proper completion of the work. |
| 99 | Same as item above but on new wood surface. |
| 100 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 101 | Providingandfixingwaterclosetsquattingpan(IndiantypeW.C.pan)with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern withmanuallycontrolleddevice(handlelever)conformingtoIS:7231, Parryware/Hindware/Seabird/Orient(Coral)withallfittingsandfixturescomplete including cutting and making good the walls and floors wherever required. |
| 102 | Providing and fixing whitevitreous china flat back half stallurinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps(all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the wallsand floors wherever required: |
| 103 | Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cmdeepand1.8cmthickfixedinUrinalpartitionsbycuttingachaseof appropriatewidthwithchasecutterandembeddingthestoneinthechase with epoxygroutorwithcementconcrete1:2:4(1cement:2coarsesand:4graded stoneaggregate6mmnominalsize)asperdirectionofEngineer-in-chargeandfinished smooth. |
| 104 | Providing and fixing unplasticised PVC connection pipe with brass unions 15 mmnominal bore |
| 105 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931a) 15 mm nominal bore |
| 106 | Providingandlayingcementconcrete1:5:10(1cement:5coarsesand:10 graded stone aggregate 20mm nominal size)around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) |
| 107 | 110 mm dia |
| 108 | 90 mm dia |
| 109 | Providing andfixingonwallfaceunplasticised-RigidPVCrain waterpipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 110 mm. |
| 110 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories forunplasticisedRigidPVCrainwaterpipesconformingtoIS:13592 TypeA includingjointingwithsealringconformingtoIS:5382leaving10mmgapforthermal expansion. |
| 111 | 110 mm Bend |
| 112 | 110 mm Shoe |
| 113 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cmdiameter and weighing not less than 440 grams. |
| 114 | Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc.complete. 110 mm. |
| 115 | Makingkhurras45x45cmwithaverageminimumthicknessof5cmcement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominalsize)overPVCsheet1mx1mx400micron,finishedwith12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 116 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stabilityforhot&coldwatersupplyincludingallCPVCplain&brassthreaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction ofEngineer in Charge. |
| 117 | 20mm dia nominal outer dia pipes |
| 118 | 25mm dia nominal outer dia pipes |
| 119 | Providing and fixingGI pipes complete with GI fittings and clamps,including cutting and making good walls etc. (internal work). |
| 120 | 20mm dianominal bore |
| 121 | 25mm dia nominal outer dia pipes |
| 122 | Painting GI pipes and fittings with SYNTHETIC enamel paint over a ready mixed priming coat, both of approved quality for new work.20mm dia nominal bore |
| 123 | 25mm dia nominal outer dia pipes |
| 124 | Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work). 20mm dia nominal bore |
| 125 | Providing and fixing gun metal gate valve with wheel of approved quality. |
| 126 | Providingandplacingonterrace(atallfloorlevels)polyethylenewaterstorage tankISI:12701markedindicatingtheBISLicenseNo.withcoverandsuitable lockingarrangementandmakingnecessaryholesforinlet,outletandoverflow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotusor equivalent having valid ISI license]. |
| 127 | Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, withina lead of 50m. |
| 128 | Providing, laying and jointing glazed stoneware pipes grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing ofjoints etc. complete. 100mm diameter |
| 129 | Providingandlayingcementconcrete1:5:10(1cement:5coarsesand:10graded stone aggregate 40mm nominal size) all roundS.W. pipes including bed concrete as per standard design. 100mm dia SW pipe |
| 130 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement: 2 fine sand ) including testing of joints etc. complete. |
| 131 | Providingandlayingcementconcrete1:5:10(1cement:5coarsesand:10graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design |
| 132 | Providingandfixingsquare-mouthS.W.gullytrapgrade‘A’completewithC.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design With Sewer bricks conforming to IS :4885 |
| 133 | ProvidingandfixingonwallfaceunplasticisedRigidPVCsoilandwastewater pipes conforming to IS : 13592 Type B including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. |
| 134 | a) 110mm dia P.V.C. pipe |
| 135 | b) 90mm dia P.V.C. pipe |
| 136 | Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince). P-Trap type Floor Trap 110 x110mm. |
| 137 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mmgap for thermal expansion. |
| 138 | 110mm bend |
| 139 | 90 mm bend |
| 140 | Coupler 110mm |
| 141 | Coupler 90mm |
| 142 | Providing & fixing Soap Dispenser with Metallic bottle JAQUAR ACN-CHR- 1137N |
| 143 | Providing and fixing pvcInlet fitting with 2 inlets 80 mm size fabricated from 110 mm dia PVC pipes(approx. length=150mm to 300mm) and fixed to PVC trap with joint and set in cement concrete as per standard drawing complete. |
| 144 | SOAK PIT : Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm drybrickhoney combshaftwithbricksofclassdesignation 75and S.W.drain pipe 100 mm diameter, 1.8m long complete as per standard design. |
| 145 | Wiringpointsforlightwith1sqmm.FRLSHPVCinsulatedsinglecorecopper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FRLSH PVCinsulatedmultistrandcopperconductorcableasearthcontinuitywireandpiano type switch etc. complete in all respects. |
| 146 | Same as above item but for fan and lightduty exhaust fan. |
| 147 | Erectionandtestingexhaustfanontheexhistingholewithsuitablesizeofragbolts nuts and washers etc. complete in all respects. |
| 148 | Supply & fixing of fancy type round ceiling fitting made of polycarbonate suitable for and with 1x15/18 watt CFL complete in all respect. |
| 149 | Supply&fixingofindustrialbulkheadfittingwithpolycarbonatebaseguard,prismatic reflector silicon gasket suitable for and with 1 x 18 Watt CFL complete in all respect |
| 150 | Supplyandfixingofflush/surfacemountingdistributionboardscompleteinallrespects. 8 Way SPN |
| 151 | Supply and fixing of 6Amp to 32 Amp(10 KA) MCB in existing MCB, DB completewith connections as required. |
| 152 | Supplyfixingand makingconnection offollowing FPMCBScomplete inallrespects as per direction and satisfaction of engineer-in-charge. |
| 153 | Supply and fixing Single Pole MCBS Blanking Plate complete in all respects. |
| 154 | Supply and erection of AC 230/250 Volts,50Hzexhaustfansincludingprovidingnuts,bolts,mountingframeandother accessories including connections etc. complete as required |
| 155 | M.S. GATE |
| 156 | Mild steel or iron work in heavy sizes such as trusses built up gates, door frames, recordracks,roofworkgatesetc.wroughttorequiredfromincludingsupplyof steelanditswastageincludingcostofbolts,nutsifrequiredforandwelding, grindingandmakingholesasrequiredcompletionofworkfabricationofholesdoors, chaukhats nosing. |
| 157 | Painting one coat over priming coat (but including cost of priming coat) on steel andothermetalsurfacesupto10cm.widthorgirthorsmallarticlesnot exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi- glossapcolitesuperlac,DULUXspecifiedbrushingtogiveanevenshadeand includingcleaningthesurfaceofalldirt,dustandotherforeignmattersand paperingand stopingincluding costof allmaterials, labour tools andplants etc.required for proper completion of the work. |
| 158 | 4.5 M WIDE ROAD |
| 159 | Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and rammingof bottomsand disposalof surplusexcavated earthas directedby theEngineer i/c with in a lead of 50m. |
| 160 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacityafterexcavatingearthtoanaverageof22.5cmdepth,dressingto camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50metres. |
| 161 | Construction of granular sub-base by providing close graded Material conforming tospecifications,mixinginamechanicalmixplantatOMC,carriageofmixed material byippers to work site, for all leads & lifts, spreading in uniform layers of specifiedthicknesswithmotorgraderonpreparedsurfaceandcompactingwith vibratory power roller to achieve the desired density, complete as per pecificationsanddirectionsofEngineerin-ChargeWithmaterialconformingto Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 162 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batchingplant.Theready mixedconcreteshallbe laidand finishedwith screed boardvibrator,vacuumdewateringprocessandfinallyfinishedbyfloating, broomingwithwirebrushetc.completeasperspecificationsanddirectionsof Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note: Cementcontentconsideredinthisitemis@330kg/cum.Excess/lesscement used as per design mix is payable/ recoverable separately). |
| 163 | External W/S arrangement, T.W. boring of 150mm dia with 100mm dia P.V.C. pipe assembly, 1.5 H.P. submersible pump including supply of allaccessories starter, panel etc. & pipe arrangement etc. |
| 164 | 6\" PVC casing pipe of ISI mark. |
| 165 | P/ F 2\" GI pipe (B) class. |
| 166 | Nylon mesh for filter. |
| 167 | Plastic dori. |
| 168 | Solvent cement. |
| 169 | 6\" End cap. |
| 170 | 6\" Submersible cap. |
| 171 | 2\" MS clamp (Heavy). |
| 172 | 2\" GI elbow. |
| 173 | 2\": X 6\" GI nipple. |
| 174 | 2 HP 9 Stage submersible pump of ISI mark with automatic panel. |
| 175 | 2.5 sqm. Submersible cable. |
| 176 | Drilling charges for 6\" dia tubewell. |
| 177 | Pea Gravel. |