| 1 | B & R Portion |
| 2 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50 m depth for foundation etc. and getting out in soft/loose soil. |
| 3 | M & L for PCC (1:5:10) type E-2, using 40mm graded stone aggregates as in foundation filling & mass concrete all as specified |
| 4 | M & L 75mm thick PCC (1:4:8) type D-2, using 40mm graded stone aggregate as in sub base for flooring |
| 5 | M & L Brick work built in CM 1:6 with sub class \"B\" bricks straight or curved on plan exceeding 6 m mean radius. |
| 6 | Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 |
| 7 | M&L for providing RCC M25 design mix as in footings , foundations beams , plinth beams etc complete all as specified and directed by engr in charge |
| 8 | M&L for providing RCC M25 design mix as in columns , pillers , piers , posts and struts completeetc complete all as specified and directed by engr in charge |
| 9 | M & L for providing RCCM 25 using 20 mm graded aggregate in for beams, cantilevers, bressummers, lintels. |
| 10 | M & L for providing RCCM 25 using 20 mm graded aggregate in for slab supported on walls |
| 11 | M&L for form work to sides of foundation sides & sofits of foundation beams plinth beam etc and similar work verticle or batter for rough finished surface of concrete flats complete all as specified and as directed |
| 12 | Use and waste Formwork to sides of pillars, posts, struts, piers,columns, and stanchionsfor fair finished surfaces of concrete , square. |
| 13 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick flat fair finished surfaces of concrete |
| 14 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5cm but n exc 10cm wide |
| 15 | Formwork to sides and soffits of Roof beams,Gable beams & lintel beam rough finished surfaces of concrete. |
| 16 | S&F Mild steel bars TMT 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to Fe - 410 - 0 or Fe - 310 - 0 all as specified and directed. |
| 17 | Same as item above but 8 mm dia stirupps , spacers and binders complete all as specified and as directed |
| 18 | Rendering 15mm thick in cement mortar1:6 on other than fare face of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement |
| 19 | Rendering 15mm thickin cement mortar in 1:4 on fare face of brick work or concrete surfaces even and smoothe without using extra cement & with using integral water proofing compound |
| 20 | M&L for rendering 5 mm thick in cement mortar in (1:3) finishing the surfaces even and smooth on ceiling complete all as specified. |
| 21 | S&F Solid PVc Door Frame of Size 50 mm X 47 mm made out of 5 mm plain colour PVC Sheet reinforced with MS Square tube, suppling and fixing in opening as per specification & drawing and as directed by engineer-in-charge |
| 22 | S&F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail;Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 23 | S&F aluminium anodised 100 mm long butt hinges with galvanised mild steel screws complete |
| 24 | S&F aluminum anodised tower bolts 150 mm long complete |
| 25 | S&F aluminum anodised handles , cast type anodised 125mm long complete |
| 26 | S7F 2nd class HW 35mm thick facotry made panelled shutters with lock rail and panel of 9 mm bwp commercial ply of 12 mm veneered particle board with commercial veneering on both faces . The size of rail and stylr as per IS-1003 (pt-I) klin seasoned and chemically pressure treated complete all as specified . |
| 27 | S&F mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, length of bolt 300 mm. |
| 28 | S&F mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 200mm. |
| 29 | S & F 150 mm mild steel pressed handles, oval type, stove enamelled black. |
| 30 | Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed |
| 31 | S & F 4 mm thick figured glass, pin head type and glazing with oil putty in ventilator complete. |
| 32 | S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and avarage width of aparture 1.18 mm and fixed with tinned tacks ro galvanised wire stapple |
| 33 | M & L hard coreof gauge not exceeding 63 mm deposited spread and levelled in layers not exceeding 15 cm thick watered and rammed to a true surface with broken bricks bats . |
| 34 | M&L for 15 mm thick Screed bed or bedding layer in CM (1:4) set and jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified.Note : Using only course sand in screed bed. |
| 35 | M&L Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but n.exc 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match |
| 36 | M&L for 10 mm thick rendering in cement mortar1:4and finish the surface rough to receive the tile finish etc complete all as specified.Note :- Rendering will be done in course sand (Toka sand) only |
| 37 | S&F glazed ceramic coloured tiles 7mm thick 450 x 300mm size in verticle surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade. etc complete all as specified. |
| 38 | S&Fvitreous china squatting pan Orissa pattern of size 580mm x 440mm with integral foot rest and \"P\" or \"S\" trap including Cementconcrete bedding , connecting flushing pipe and `P\" trap, complete all as specified |
| 39 | S & F 10 litre capacity PVC valve less syphonic action type flushing cistern low level, white, with inlet, ball valve, float and handle including brackets complete |
| 40 | S & F tubes medium grade galvanised with all fittings 15 mm bore and fixed complete to walls and ceiling or laid in floor etc. |
| 41 | S & F tubes medium grade galvanised with all fittings 20 mm bore and fixed complete to walls and ceiling or laid in floor etc. |
| 42 | S&F 500 litres capacity Rotational moulded polyethylene in white colour, three layered, water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position |
| 43 | S & F cast copper fancy type chromium platedalloy bib tap for 15 mm bore of pipe screwed down, screwed for iron pipe or for brass furrel and fixed. |
| 44 | S & F cast copper alloy chromium plated fancy type stop valves for 15 mm bore of pipe screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed. |
| 45 | S & F cast copper alloy chromium plated fancy type stop valves (concealed type) for 15 mm bore of pipe screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed. |
| 46 | S & F Ball brass valves high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed for 20 mm dia bore of pipe. |
| 47 | S & F100 mm bore cast iron (spun) soil, waste and vent pipes, ISI marked in any length with or without ears, with cement joints, fixed to walls with and including suitable size clamps / laid in trenches. |
| 48 | S & F75 mm bore cast iron (spun) soil, waste and vent pipes, ISI marked in any length with or without ears, with cement joints, fixed to walls with and including suitable size clamps / laid in trenches. |
| 49 | S & F 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door. |
| 50 | S & F 75 mm bore cast iron bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door. |
| 51 | S&F 75 mm dia CI floor trap with grating incluing jointing to waste pipe fixed in cement concrete (1:2:4) type B-1, completeall as specified. |
| 52 | S & F 100 mm dia cast iron branch pieces, single (equal or un-equal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete. |
| 53 | S&F 100 mm bore CI cowl complete all as specified and directed |
| 54 | S&F 75 mm bore CI cowl Complete all as specified and directed |
| 55 | M&L for 100 mm dia of CI P trap long with grating incl jointing to waste pipe fixed in cement mortar 1:2:4 type b 1 in repair complete all as specified |
| 56 | S&F pressed steel frames of size 105x60 mm for doors with one or more rebates incl necessary fixing lugs , hinges , lock strike plate etc ( thickness of sheet shall be 1.25 mm) and making good the wall with plaster in CM 1:6 complete all as specified |
| 57 | M&L PCC 1:3:6 type c-1 using 20mm graded stone aggreegates for filling in bed block of hold fast etc complete all as specified and as directed |
| 58 | S&F brass chromium plated shower rose 125 mmsize with or without swivel joints fix to steel pipe or union complete all as specified anddirected |
| 59 | PCC (1:3:6) type C-2 (using 40mm graded agg) 75mm thick as in plinth protection. |
| 60 | M & L preparation of newly plastered surfaces of walls and applying two coats of cement base paint. |
| 61 | M & L preparation of newly plastered surfaces of wallsand applying three coat of white wash on walls. |
| 62 | M&L for prepairing new surfaces of ceiling and applying two coat of white wash etc complete all as specified. |
| 63 | M & L returning filling including spreading levelling watering and well ramming in layers n exc 25 cm in soft/loose soil. |
| 64 | M & L removing excavated material exc 250n exc 500 m and depositing where directed at a level n exc 1.5 m above the starting point. |
| 65 | Supply only liquid integral water proofing compound of approved quality and make confirming to IS. |
| 66 | S & Fvitreous china white wash hand basin white flat back size 450 x 300 mm excluding waste chain and plug on porcelain stopper butt including brackets. |
| 67 | S&F Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) including connections to flushing pipe and out going pipes etc complete all as specified and directed. |
| 68 | S & Fpillar taps cast copper alloy chromium plated fancy type with Capstan Head CP fixed connects with 15mm dia bore of pipe. |
| 69 | S&F brass chromium plated tubular towel rail 20 mm dia D type, 60 cm long between flanges complete all as specified and as directed. |
| 70 | S & F PVC connections 15 mm dia with PTMT Nuts of length for 600 mm Long. |
| 71 | S & F 600 x 450mm bevelled edge selected quality looking mirror. |
| 72 | M&L preparation of newly wooden surface of any description & applying two coats of synthetic enamel paints over ofpin primer includ preparation of surface. |
| 73 | M&L preparation of newly steel surface of any description & applying two coats of synthetic enamel paints over red oxideprimer includ preparation of surface. |
| 74 | S&F urinal spredaer of PTMT any colour for fixing with 15mm dia pipe (minimum weight 60 gms) |
| 75 | Concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested in cement concrete type D-2 1:4:8using 20 mm graded curshed stone aggregates for 150mm bore pipes. |
| 76 | Salt glazed stoneware (SGSW) grade `A\"drain pipes 150mm bore laid and jointed on concrete bed, complete including testing etc all as specified and shown drawings (Concrete bed shall be assured and paid for separately). |
| 77 | M&L for cementconcrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation , filling and mass concrete surface completeall as specified and directed. |
| 78 | S&F Pre-painted galvalume aluminium zinc coating G.I based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering, fixed withself taping screws complete all as specified and directed. |
| 79 | S&F for providing and fixing stainless steel (Grade 304) railing made of hollow tubes channels, plates etc includingwelding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc of required size, on the top of floor or the side of waist slab with suitable arrangementcomplete all as specified and directed. |
| 80 | Surface excavation n.exc 30cm deep and averaging 15cm deep and getting in soft/loose soil complete all as specified and directed. |
| 81 | M&L for brick work with sub class \"B\" brick (Modular Bricks/Tiles) straigth or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 82 | Excavating in Post holes soft/loose soil (or simillar holes ) n exc 0.5 cum getting out returning filling in and reaming earth or broken rubble mixed with earth around , in layers n exc 25 cum watering and removing surplus soil to a distance n. exc. 50 m and making good surface complete all as specified |
| 83 | Removing excavated mtrl n .exc 50 mt & deposited where dirrected at a level n exc 1.5 mtr above the starting point complete all as specified. |
| 84 | M&L for PCC (1:2:4) type B-2 ,using 40mm graded stone aggregate as in foundation filling& mass concrete all as specified |
| 85 | S & F Pre-painted galvalume alumunium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall ,fixed with self tapping screws all as specified |
| 86 | M & L Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified |
| 87 | M& L Steel work in tubular post 10mm Dia including special shaped washer etc complete using ERW or including butt welded tubes conforming to I.S-4923-1979 grade St -2240 including rolled mild steel as in joist channel ,angle,or tee sections fixed independently , without connecting plates , etc (cut to ordinary legth ie within 20mm of tile length indicated of gde Fe 410 -S ,complete all as specified amd directed |
| 88 | Mild steel screw bolts (machine made ) with hexagonal or square heads at one end and screwed the other or screwed both ends ,each screwed end to be fiitted with washer and one hexagonal or square nut length of bolt exc 5 cm but n exc 10cm long complete all as specified amd directed |
| 89 | M&L preparing steel surfaces over 10cm width or girth and applying two coat synthetic enamel paint over a coat of red oxide primer completeall as specified and as directed . |
| 90 | S & F machine pressed precast concrete interlocking paver block any shape and size confirming to SI 15658-2006 of 60 mm thickness, M-35 grade with grey cement and no pigment completeall as specified and as directed . |
| 91 | M&L for 25mm thick sand filling under interlocking tiles including watering and consolidating completeall as specified and as directed . |
| 92 | M&L for PCC (1:4:8) type D-2 ,using 40mm graded stone aggregate as in foundation filling& mass concrete in manholes etc. completeall as specified and as directed . |
| 93 | M&L for PCC (1:2:4) type B-1 ,using graded stone aggregate at manhole bedding & coping completeall as specified and as directed . |
| 94 | M&L for TMT bars 8 mm dia and over cut to length and bent to shape required including cranking, hooking ends and binding with and MS wire not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 95 | M&L for brick work with sub class \"B\" brick (Old size Bricks/Tiles) straigth or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 96 | M&LRCC (1:2:4), type B1 (using 20 mm graded crushed stone aggregate) Precast cement concrete cover slab for manhole and similar article with plain face, set in cement mortar 1:4including demolition complete all as specifed and directed. |
| 97 | M&L for precast factory RCC drain of shape & size as directed by GE alongwith male and female ends for proper jointing made of RCC 1:2:4 type B-1 using 20mm graded aggregate, 75mm thick and reinforced with 8mm TMT bar @ 100mm c/c both ways two numver of sockets for hoisting including necessary formwork etc including hoisting and placing at site, jointed in CM 1:4 to from uniform length and fair finish to drain upto 80 cm girth (width measured @ avg of inner girth and outer girth).Note : Reinforcement shall be measured and paid separately) |
| 98 | S&F Reinforced concrete pipes, class NP2, 300 mm dia laid and jointed including complete demolition of pipes with collars all as specifed and directed. |
| 99 | S&F Reinforced concrete pipes, class NP2, 450 mm dia laid and jointed including complete demolition of pipes with collars all as specifed and directed. |
| 100 | M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate)Concrete bed to 200 mm bore drain pipes including packing under and hauching & Benchingagainst the sides of pipes after they are laid and tested all as specified and directed. Note :- (i) Thickness of bed below the barrel of pipes:15cm for pipes 150mm dia and over.(ii) Width of bed: Outer diameter of drain pipes (not of sockets/collars) plus 30 cm(iii) The rates include for any necessary shuttering and supports to concrete and for laying beds to falls. |
| 101 | S&F Framed work such as grills, gratings coolar stand, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165including dismantling of existing complete all as specified. |
| 102 | E & M Portion |
| 103 | M & L forPoint wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, GI terminal boxes, modular frame & cover plate (suitable for modular switch/sockets) comprising the following: - |
| 104 | One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit complete all as specified and directed. |
| 105 | One Socket outlet three pin, 6 Amp, on the same board, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, complete all as specified and directed. |
| 106 | One socket outlet three pin, 5/15 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor,in and including rigid non metallic PVC heavy duty concealed conduit complete all as specified and directed. |
| 107 | Note for Serial item No. 103.00 to 103.03.1.Switch (es) & socket(s) shall be measured & paid for separately under respective item of schedule \"A\"2.GI boxes shall befixed flush in position with cement mortar (1:4)complete all as specified and directed. |
| 108 | S&F Switch modular type single pole, one way, 6 Amp, one module, complete all as specified. |
| 109 | S&F Switch modular type single pole, one way, 16 Amp, one module, complete all as specified. |
| 110 | S&F Socket outlet modular type, multipurpose, 2/3 pin, single pole one way, 6 Amp,two module, complete all as specified. |
| 111 | S&F Socket outlet modular type, multipurpose, 2/3 pin, single pole one way, 6/16 Amp,two module, complete all as specified. |
| 112 | S&F Ceiling rose, 3 terminal PVC/polycarbonate, suitable for 230 V, AC, 50 Hz supply. |
| 113 | S&F angle Lamp holder PVC/polycarbonate type with back plate complete all as specified |
| 114 | S & F LED 7w Lamp, 6500K, base B-22 efficacy not less than 90 lumen/watt complete all as specified |
| 115 | S&F MCB 6-32 Amp 240V SP 10 KA ‘B’ series complete all as specified |
| 116 | S&F RCBO for earth Leakage, Over Load and short CircuitProtection 415V40 to63 Amp AC Type 10 KA Four Pole 30mA ISI markedcomplete all as specified and directed. |
| 117 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheating of PVC taps and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire, one twin core cable flat or circular of size 10.0 sqmm including 01 x house service brackets made up of 40mm dia medium grade GI pipe bent at 90 angle of length not more than 3.0m complete all as specified and directed. |
| 118 | Supply and Fixing wall mounted extruded Aluminium/polycarbonate integrated LED batten fixture with tube 1.2 m, 20watt, T5 6500K,efficacy not less than 90 lumen/watt worm white, extruded Aluminium/polycarbonate, PC diffusor and integrated inbuilt driver completecomplete including making connection complete all as specified and directed. |
| 119 | S & F wall mountede LED batten fitting 1x10 watt, 6500K, 2ft complete with decorative ultra slim square profile LED lighting fixture with extruded polycarbonate enviroment friendly, energy efficient complete with all light fittings connection complete all as specified. |
| 120 | S&F in replacement sheet metal encloser double door 8 way SPN 230V ISI marked complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed |
| 121 | S&F & testing for storage type water heater (Geyser) electrical operated 230/240 volts 25 ltr capacity, BEE 5 star rated complete including manufactureed recommended multipurpose value, NRV, plug top, flexible pipe of set of two, sheathed cable etc. & including electric/earth connections and carrying out grouthing & complete installations with mounting boths nutscomplete all as specified and directed |
| 122 | S&F Heavy duty metal body exahust fan of 250mmsweep ,240 volt, having RPM not less than 1200,complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVCsheathed copper conductorflexible cable 24/0.2mm from ceiling rose to fan complete including grouting of bolts and making good to distubed wall complete all as specified and directed |
| 123 | S&F LED street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrossion resistant complete with IP 65/66 protection including fixing with GI/MS bracket made out of suitable size of light grade tube upto 1.2 mtr length bent to shape with 02 sets of MS clamps made out of minimum 3 mm MS flat iron with suitable bolt and nuts complete with making connection complete allas specified and directed |
| 124 | M & L for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burriedin ground vertically to earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick eachconnected to and including GI earth wire 4 mm dia by means of nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate to distribution board and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using stone aggregates)for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I andtesting on completion including replacement of old unserviceable.Note:- It is mandatory to paint a sqaure shape notice board of yellow color with legible black color letters of earthing mentioned details as below; Cost incurred deemed to be inlcuded in quoted rate:- |