Supply Of Lcp 3.5 Mm Titanium Set,Lateral Titanium Clavicle Plate Set, Lcp-Titanium Distal Humerus, Cannulated Titanium Screws, Lcp Titanium Set For Calcanium, 3.5Mm Lcp Titanium Set For Fracture, Lcp Titanium- Proximal Humerus Fracture, Lcp - Titanium Communited Clavicle Fracturelcp 3.5 Mm Titanium Set,Lateral Titanium Clavicle Plate Set, Lcp-Titanium Distal Humerus, Cannulated Titanium Screws, Lcp Titanium Set For Calcanium, 3.5Mm Lcp Titanium Set For Fracture, Lcp Titanium- Proximal Humerus Fracture, Lcp - Titanium Communited Clavicle Fracture,Srphc401491-Lcp 3.5 Mm Titanium Set For Clavicle Shaft Fracture - Consisting Of On E Precontoured Locking Screw Plate With 6 Locking Screws With Appropriate Sizes And Sides (L Eft Or Right) Of Plates For The Correct Side The Necessary And Correct Instrumentation Must Be Supplied Along With The Set. It Must Be Supplied As And When Required Basis. Unit:Set Items M Ay Be Supplied With Brand Johnson & Johnson/Marquardt/Auxein/Irene Or Similar. [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitted: Ma X 8 Lacs ] ] Achd/Surg.Store/Rh/Per, Sr Tamil Nadu 25.00 Set , Srphc401498-Lateral Titanium Clavicle Plate.Set Consists Of Lateral Clavicle Plate Of Different Sizes With 3.5 Screws Option In Medial Fragment And 2.7 Screw Fixation Laterally With Necessary Sleeves And Instruments. Unit:Set Items May Be Supplied With Brand Johnson & J Ohnson/Marquardt/Auxein/Irene Or Similar. [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitted: Ma X 8 Lacs ] ] Achd/Surg.Store/Rh/Per, Sr Tamil Nadu 5.00 Set , Srphc401494-Lcp-Titanium Distal Humerus Extra Articular Plate 6810 Lcp Combihole S 3.5Mm 7 Locking And 2 Cortex Screws Of Length 12Mm To 60Mm With Flat Rounded Profiles An D Right Left Version Option With Complete Set Of Instrumentations. Unit:Set Items May Be Suppli Ed With Brand Johnson & Johnson/Marquardt/Auxein/Irene Or Similar. [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitted: Ma X 8 Lacs ] ] Acms/Surg.Stores/Rh/Tvc, Sr Kerala 3.00 Set , Srphc401489-Cannulated Titanium Screws For Scaphoid And Distal Humerus Fractu Res Includes 2.4Mm Headless Compression Screws.One Number ( All Possible Lenghts) With Necc Essary And Correct Instrumentations Must Be Suplied Along With The Set. It Must Be Supplied A S And When Required Basis. Unit:Set Items May Be Supplied With Brand Johnson & Johnson/Marqu Ardt/Auxein/Irene Or Similar. [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitted: Ma X 8 Lacs ] ] Achd/Surg.Store/Rh/Per, Sr Tamil Nadu 30.00 Set Acms/Surg.Stores/Rh/Tvc, Sr Kerala 3.00 Set , Srphc401490-Lcp Titanium Set For Calcanium - Consisting Of One Lcp Plate Eight Loc King Screws And Two Cortical Screws With Appropriate Sizes And Sides (Left Or Right) Of Plate S For The Correct Side And Appropriate Screws Of 3.5Mm Diameter. The Necessary And Correct I Nstrumentation Must Be Supplied Along With The Set. It Must Be Supplied As And When Required Basis. Unit:Set Items May Be Supplied With Brand Johnson & Johnson/Marquardt/Auxein/Irene Or Similar. [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitted: Ma X 8 Lacs ] ] , Srphc401493-3.5Mm Lcp Titanium Set For Fracture Both Bones Fore Arm - Consisting Of Two Lcp Plates Six Or Seven Or Eight Combi Holes For Locking Or Cortical Screws And Ten L Ocking Screws And 4 Cortical Screws.The Set Must Be Supplied As And When Required Basis Wit H Appropriate Sizes And Sides (Left Or Right) Of Plates For The Correct Side And Appropriate Lo Cking Screws As And When Required.The Necessary And Correct Instrumentation Must Be Suppl Ied Along With The Set. Unit:Set Items May Be Supplied With Brand Johnson & Johnson/Marquard T/Auxein/Irene Or Similar. [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitted: Ma X 8 Lacs ] ] Achd/Surg.Store/Rh/Per, Sr Tamil Nadu 20.00 Set Acms/Surg.Stores/Rh/Tvc, Sr Kerala 6.00 Set , Srphc401495-Lcp Titanium- Proximal Humerus Fracture-Anatomically Contoured Pl Ate Applied On The Lateral And Anterior Surface Of Proximal And Middle Third Of Humerus With Locking Screws . To Be Supplied As One Plateseven Locking Screws And One Cortical Screw Wit H Appropriate Sizes Of Plates And Screws And The Necessary And Correct Instrumentations. Un It:Set Items May Be Supplied With Brand Johnson & Johnson/Marquardt/Auxein/Irene Or Similar. [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitted: Ma X 8 Lacs ] ] Achd/Surg.Store/Rh/Per, Sr Tamil Nadu 25.00 Set Acms/Surg.Stores/Rh/Tvc, Sr Kerala 2.00 Set , Srphc401497-Lcp - Titanium Communited Clavicle Fracture Including Lateral Commu Nition With Anterosuperior Plate Orientation. To Be Supplied As One Plate Five Locking Screws And One Cortical Screw With Appropriate Sizes Of Plates And Screws And The Necessary And C Orrect Instrumentation. Unit:Set Items May Be Supplied With Brand Johnson & Johnson/Marquar Dt/Auxein/Irene Or Similar. [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitted: Ma X 8 Lacs ] ]