}

Tender For Thumpoly St.Thomas Poomkavu Church,Pilgrimtourism,Alappuzha - Civil Works-Ground Floor 2 2.31 Clearing Jungle Including Uprooting Of Rank Vegetation, Grass, Brush Wood, Trees And Saplings Of Girth Up To 30 Cm Measured At A Height Of 1 M Above, pathirappally-Kerala

Kerala State Nirmithi Kendra has published Tender For Thumpoly St.Thomas Poomkavu Church,Pilgrimtourism,Alappuzha - Civil Works-Ground Floor 2 2.31 Clearing Jungle Including Uprooting Of Rank Vegetation, Grass, Brush Wood, Trees And Saplings Of Girth Up To 30 Cm Measured At A Height Of 1 M Above. Submission Date for this Tender is 08-09-2025. Copper Cable Tenders in pathirappally Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

50802277
Tender For Thumpoly St.Thomas Poomkavu Church,Pilgrimtourism,Alappuzha - Civil Works-Ground Floor 2 2.31 Clearing Jungle Including Uprooting Of Rank Vegetation, Grass, Brush Wood, Trees And Saplings Of Girth Up To 30 Cm Measured At A Height Of 1 M Above
Tender
Indian
Kerala
Pathirappally
08-09-2025

Tender Details

Tender For Thumpoly St.Thomas Poomkavu Church,Pilgrimtourism,Alappuzha - CIVIL WORKS-GROUND FLOOR 2 2.31 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 3 2.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soi 4 4.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) 5 5.9.1Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete 6 5.9.2Centering and shuttering including strutting, etc. and removal of form for:Walls (anythickness) including attached pilasters, butteresses, plinth and string courses etc. 7 5.9.3Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform 8 5.9.5Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers 9 5.9.6Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts 10 5.9.7Centering and shuttering including strutting, etc. and removal of form for:Stairs,(excluding landings ) except spiral - staircases) 11 5.9.19Centering and shuttering including strutting, etc. and removal of form for:Weathershade, Chajjas, corbels etc., including edges 12 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more 13 5.33.1.1Providing and laying in position ready mixed or site batched design mix cementconcrete for reinforced cement concrete work; using coarse aggregate and fineaggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 toaccelerate / retard setting of concrete, to improve durability and workability withoutimpairing strength; including pumping of concrete to site of laying, curing, carriagefor all leads; but excluding the cost of centering, shuttering, finishing andreinforcement as per direction of the engineer-in-charge; for the following grades ofconcrete. Note: Extra cement up to 10% of the minimum specified cement content indesign mix shall be payable separately. In case the cement content in design mix ismore than 110% of the specified minimum cement content, the contractor shall havediscretion to either re-design the mix or bear the cost of extra cementAll work upto plinth levelConcrete of M25 grade with minimum cement content of330 kg /cum 14 5.33.2Providing and laying in position machine batched and machine mixed design mix M25 grade cement concrete for reinforced cement concrete work, using cement contentas per approved design mix, including pumping of concrete to site of laying butexcluding the cost of centering, shuttering, finishing and reinforcement, includingadmixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as perdirection of Engineer - in-charge. Note:- Cement content considered in this item is @330 kg/ cum. Excess or less cement used as per design mix is payable or recoverableseparately.All work above plinth level upto floor V leve 15 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 16 50.2.25.1Filling with contractors own earth ( excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per directionof site Engineer-in-charge 17 50.6.1.5Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cmor nearest available size confirming to IS 2185 Part I of 1979 for super structure up tofloor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etccomplete 18 50.6.2.2Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm ornearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etccomplete 19 9.1.1Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paid forseparately).Second class teak wood 20 9.5.1.1Providing and fixing panelled or panelled and glazed shutters for shutters for doors,windows and clerestory windows, including ISI marked M.S. pressed butt hingesbright finished of required size with necessery screws, excluding panelling which willbe paid for separately, all complete as per direction of Engineer - in-charge.Second class teak wood35 mm thick shutters 21 9.7.1 Providing and fixing panelling or panelling and glazing in panelled or panelled andglazed shutters for doors, windows and clerestory windows (Area of opening forpanel inserts excluding portion inside grooves or rebates to be measured), Panellingfor panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teakwood 22 50.9.1.1Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paid forseparately), using good quality Anjili wood /jack wood 23 50.9.2.1Providing and fixing paneled and glazed shutters for doors, windows and clerestorywindows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges brightfinished of required size with necessary screws, excluding panelling which will bepaid for separately, all complete as per direction of Engineerin - charge using Anjili/Jack wood 24 50.9.4.1Providing and fixing paneling or paneling and glazing in paneled or paneled andglazed shutters for doors, windows and clerestory windows (Area of opening forpanel inserts excluding portion inside grooves or rebates to be measured) paneling forpaneled or paneled and glazed shutters 25 mm to 40 mm thick using good qualityAnjili/ Jack wood 25 50.9.5.1Providing and fixing glazed shutters for doors, windows and clerestory windowsusing 4 mm thick float glass panes including ISI marked M.S pressed butt hingesbright finished of required size with necessary screws. Using Anjili wood/ jack wood35 mm thick shutters. 26 21.1.1.2Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron) 27 21.3.2Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 5.50mm thickness (weight not less than 12.50 kg/sqm) 28 9.48.2Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 29 9.123Providing and fixing factory made door frame (single rebate) made out of single pieceextruded solid PVC foam profile with homogeneous fine cellular structure havingsmooth outer integral skin having 62 mm width & 32 mm thickness, frame will bemitred & jointed with self driven self tapping screws of size 38 mm x 4 mm & PVCsolvent cement, including fixing the frame to wall with suitable dia & length anchorfastener as per manufacturers specification and direction of Engineer-in-charge. 30 9.124.1Providing and fixing factory made 30 mm thick door shutter made of solid PVC foamprofile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5mm. The styles, top & bottom rails shall have one side wall thickness of 15 mmintegrally extruded on the hinge side of the profile for better screw holding power.The styles and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mm x 1mm, painted with primer, all four corners of reinforcement to be welded or sealed.Solid PVC extruded bidding (Push fit type) will be set inside the styles and the railswith a cavity, to receive single piece extruded 5 mm PVC sheet as panel. The stylesand rails will be mitred cut and joint with the help of PVC solvent cement & selfdriven self tapping screws. Single piece extruded solid PVC lock rails of sixe 100mmx 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of thelock rail & fixed with styles with the help of PVC solvent cement & self driven selftapping screws of size 100 mm x 8 mm complete as per manufacturers specificationsand direction of Engineer -in-charge.Non decorative finis 31 9.74.1Providing and fixing bright finished brass tower bolts (barrel type) with necessaryscrews etc. complete:250x10 mm 32 9.88Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6levers and a pair of lever handles of approved quality with necessary screws etc.complete. 33 10.2Structural steel work riveted, bolted or welded in built up sections, trusses and framedwork, including cutting, hoisting, fixing in position and applying a priming coat ofapproved steel primer all complete. 34 12.50Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coatedthickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade,5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoidscratches during transportation and should be supplied in single length upto 12 metreor as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/selftapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch inhorizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters andtrusses and including cutting to size and shape wherever required. 35 10.6.1Supplying and fixing rolling shutters of approved make, made of required size M.S.laths, interlocked together through their entire length and jointed together at the endby end locks, mounted on specially designed pipe shaft with brackets, side guides andarrangements for inside and outside locking with push and pull operation complete,including the cost of providing and fixing necessary 27.5 cm long wire springsmanufactured from high tensile steel wire of adequate strength conforming to IS:4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25mm M.S. laths with 1.25 mm thick top cover 36 10.7Providing and fixing ball bearing for rolling shutters. 37 12.4.1Providing ridges or hips width 60 cm overall width plain G.S. sheet fixed withpolymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumenwashers complete.0.80 mm thick with zinc coating not less than 275 gm/m2 38 11.39Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm ormore (thickness to be specified by the manufacturer), of 1st quality conforming to IS:15622, of approved make in colours White, Ivory, Grey, fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 cement : 4 Coarse sand), including grouting the jointswith white cement and matching pigments etc., complete. 39 11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm. 40 11.36Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer -inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm,including pointing in white cement mixed with pigment of matching shade complete 41 13.5.115 mm cement plaster on rough side of single or half brick wall of mix:1:4 ( 1Cement : 4 coarse sand) 42 13.7.112 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1cement : 3 fine sand)N 43 13.7.212 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1cement : 4 fine sand) 44 13.43.1Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface:Water thinnable cement primer 45 13.47.1Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additivesof required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over andincluding priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 46 13.60.1Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work 47 13.61.1Painting with synthetic enamel paint of approved brand and manufacture to give aneven shade:Two or more coats on new work 48 22.5Providing and laying water proofing treatment in sunken portion of WCs, bathroometc., by applying cement slurry mixed with water proofing cement compoundconsisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed withwater proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to aircure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed withwater proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to aircure for 4 hours followed with water curing for 48 hours. The rate includespreparation of surface, treatment and sealing of all joints, corners, junctions of pipesand masonry with polymer mixed slurry 49 10.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same with necessary stainless steel nutsand bolts complete, i/c fixing the railing with necessary accessories & stainless steeldash fasteners, stainless steel bolts etc., of required size on the top of the floor or theside of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.) 50 OD26981/2025-2026Providing and fixing 200mm solid SS finished handles with necessary screwsincluding cost conveyance fixing charge etc. complete: 51 11.16.1Precast terrazo tiles 22 mm thick with graded marble chips of size upto 12mm, laid infloors, and landings, jointed with neat cement slurry mixed with pigment to match theshade of the tiles including rubbing and polishing complete, on 20 mm thick bed ofcement mortar 1:4 (1 cement : 4 coarse sand) :Light shade pigment using whitecement 52 8.2.2.2Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded andprepolished, machine cut for kitchen platforms, vanity counters, window sills, faciasand similar locations, of required size, approved shade, colour and texture laid over20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated withwhite cement, mixed with matching pigment, epoxy touch ups, including rubbing,curing, moulding and polishing to edges to give high gloss finish etc. complete at alllevels.Area of slab over 0.50 sqm 53 16.21Engraving letters in hard stone 54 CIVIL WORKS- FIRST FLOOR 55 5.9.5Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers 56 5.9.6Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts 57 5.33.2Providing and laying in position machine batched and machine mixed design mix M25 grade cement concrete for reinforced cement concrete work, using cement contentas per approved design mix, including pumping of concrete to site of laying butexcluding the cost of centering, shuttering, finishing and reinforcement, includingadmixtures in recommended proportions as per IS: 9103 to accelerate, retard settingof concrete, improve workability without impairing strength and durability as perdirection of Engineer - in-charge. Note:- Cement content considered in this item is @330 kg/ cum. Excess or less cement used as per design mix is payable or recoverableseparately.All work above plinth level upto floor V level 58 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more 59 50.6.1.5Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cmor nearest available size confirming to IS 2185 Part I of 1979 for super structure up tofloor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etccomplete 60 50.9.1.1Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paid forseparately), using good quality Anjili wood /jack wood 61 50.9.2.1Providing and fixing paneled and glazed shutters for doors, windows and clerestorywindows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges brightfinished of required size with necessary screws, excluding panelling which will bepaid for separately, all complete as per direction of Engineerin - charge using Anjili/Jack wood 62 50.9.4.1Providing and fixing paneling or paneling and glazing in paneled or paneled andglazed shutters for doors, windows and clerestory windows (Area of opening forpanel inserts excluding portion inside grooves or rebates to be measured) paneling forpaneled or paneled and glazed shutters 25 mm to 40 mm thick using good qualityAnjili/ Jack wood 63 13.7.212 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1cement : 4 fine sand) 64 13.43.1Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface:Water thinnable cement primer 65 13.47.1Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additivesof required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over andincluding priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 66 13.60.1Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work 67 13.61.1Painting with synthetic enamel paint of approved brand and manufacture to give aneven shade:Two or more coats on new work 68 50.6.2.2Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm ornearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etccomplete 69 9.74.1Providing and fixing bright finished brass tower bolts (barrel type) with necessaryscrews etc. complete:250x10 mm 70 9.88Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6levers and a pair of lever handles of approved quality with necessary screws etc.complete. 71 PLUMBING WORKS 72 17.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983with C.I. brackets and stainless steel plug 40 mm, including painting of fittings andbrackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm 73 17.16AProviding and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre longwith S.S. triangular plate to Eureopean type W.C. of quality and make as approved byEngineer - in - charge 74 17.2.1Providing and fixing white vitreous china pedestal type water closet (European typeW.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, includingflush pipe, with manually controlled device (handle lever), conforming to IS : 7231,with all fittings and fixtures complete, including cutting and making good the wallsand floors wherever required:W.C. pan with ISI marked white solid plastic seat andlid 75 17.22AProviding and fixing CP Brass 32mm size Bottle trap of approved quality & makeand as per the direction of Engineer in charge. 76 17.4.2Providing and fixing white vitreous china flat back or wall corner type lipped fronturinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively withautomatic flushing cistern with standard flush pipe and C.P. brass spreaders withbrass unions and G.I. clamps complete, including painting of fittings and brackets,cutting and making good the walls and floors wherever required:Range of two urinalbasins with 5 litre white P.V.C. automatic flushing cistern 77 17.73.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleatswith CP brass screws with concealed fitting arrangement of approved quality andcolour600 mm long towel rail with total length of 645 mm, width 78 mm andeffective height of 88 mm, weighting not less than 190 gms 78 17.28.1.2Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC.waste fittings complete.Semi rigid pipe40 mm dia 79 17.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approvedquality) complete with 6 mm thick hard board ground fixed to wooden cleats withC.P. brass screws and washers complete. 80 17.7.4Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Flat backwash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 81 17.71Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and112 mm distance from wall of standard shape with bracket of the same materials withsnap fittings of approved quality and colour, weighing not less than 105 gms 82 17.72Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm widewith minimum distances of 37 mm from wall face with concealed fittingsarrangement of approved quality and colour, weighing not less than 88 gms 83 18.17.1Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end) :25 mm nominal bore 84 18.17.1AProviding and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end) :20 mm nominal bore 85 18.17.2 Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end) :32 mm nominal bore 86 18.17.4Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end) :50 mm nominal bore 87 18.17.5Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end) :65 mm nominal bore 88 18.17.6Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end) :80 mm nominal bore 89 18.49.1Providing and fixing C.P brass bib cock of approved quality conforming to IS:8931.15 mm nominal bore 90 18.53.1Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore 91 18.7.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings including fixing the pipe with clamps at 1.00 m spacing. This includesjointing of pipes & fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20mm nominal dia pipes 92 18.7.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings including fixing the pipe with clamps at 1.00 m spacing. This includesjointing of pipes & fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25mm nominal dia pipes 93 18.7.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includesjointing of pipes & fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32mm nominal dia pipes 94 18.7.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings including fixing the pipe with clamps at 1.00 m spacing. This includesjointing of pipes & fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40mm nominal dia pipes 95 18.7.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings including fixing the pipe with clamps at 1.00 m spacing. This includesjointing of pipes & fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50mm nominal dia pipes 96 18.8.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.15 mm nominal dia pipes 97 18.8.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.20 mm nominal dia pipes 98 18.8.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal dia pipes 99 18.8.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.32 mm nominal dia pipes 100 18.9.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply including all CPVC plain & brass threadedfittings. This includes jointing of pipes & fittings with one step CPVC solventcement, trenching , refilling & testing of joints complete as per direction of Engineerin-Charge. External work50 mm nominal dia pipes 101 18.9.8Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply including all CPVC plain & brass threadedfittings. This includes jointing of pipes & fittings with one step CPVC solventcement, trenching , refilling & testing of joints complete as per direction of Engineerin-Charge. External work80 mm nominal dia pipes 102 18.9.9Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply including all CPVC plain & brass threadedfittings. This includes jointing of pipes & fittings with one step CPVC solventcement, trenching , refilling & testing of joints complete as per direction of Engineerin-Charge. External work100 mm nominal dia pipes 103 18.19.3.1Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontal 104 18.19.4.1Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal 105 18.19.5.1Providing and fixing gun metal non-return valve of approved quality (screwed end):65 mm nominal boreHorizontal 106 18.31.1.2Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubberinsertion etc. (the tail pieces if required will be paid separately):100 mm diameterClass II 107 18.48Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank. 108 2.10.1.1Excavating trenches of required width for pipes, cables, etc including excavation forsockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, includinggetting out the excavated soil. and then returning the soil as required, in layers notexceeding 20 cm in depth, including consolidating each deposited layer by ramming,watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50m:All kinds of soilPipes, cables etc, not exceeding 80 mm di 109 2.10.1.2Excavating trenches of required width for pipes, cables, etc including excavation forsockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, includinggetting out the excavated soil. and then returning the soil as required, in layers notexceeding 20 cm in depth, including consolidating each deposited layer by ramming,watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50m:All kinds of soilPipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia 110 19.30.1.1Constructing brick masonry chamber for underground C.I. inpection chamber andbends with bricks in cement mortar 1:4 ( 1 cement: 4 coarse sand) C.I.cover withframe (light duty) 455x610 mm internal dimensions, total weight of cover with frameto be not less than 38 kg (weight of cover 23kg and weight of frame 15 kg), R.C.C topslab with 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mmnominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stoneaggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement onwalls and bed concrete etc. complete as per standard design:With common burnt clayF.P.S. (non modular) bricks of class designation 7.5 111 19.7.1.1Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand)with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick withcement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neatcement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size ) finished with a floating coat of neatcement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty)455x610 mm internal dimensions, total weight of cover and frame to be not less than38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clayF.P.S. (non modular) bricks of class designation 7.5 112 19.8.1.1Extra for depth for manholesSize 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of classdesignation 7.5 113 OD26986/2025-2026Providing and fixing Grab bar 450mm Long Also available (Cera / Approved make) 114 OD26998/2025-2026Supplying and fixing approved make C.P. twin robe hook with C.P. screws etc.,complete. Fixed on the toilet door (Cera / Approved make) 115 OD26995/2025-2026Supplying & fixing of approved make 15mm CP two way bib cock withnecessary CP wall flanges etc., complete. (Cera / Approved make) 116 OD26996/2025-2026Supplying and providing 1hp pump with foot valve and all accessories includinglabour charges conveyance etc. complete 117 OD26987/2025-2026Supply and fixing 160 mm GI flange 118 OD26993/2025-2026Supplying, laying, jointing, testing and comissioning of approved make PVCmultifloor trap with cp grating, necessary PVC puddle flanges for floor trap insidetoilet & required concrete encasing all around, complete 119 OD26984/2025-2026Providing and fixing 75mm dia PVC vent cowl to pipe already fixed as directed by Engineer in charge at all levels 120 OD26983/2025-2026Providing and fixing 110mm dia PVC vent cowl to pipe already fixed as directed byEngineer in charge at all levels 121 OD26989/2025-2026Supplying, laying, jointing, testing and commissioning approved make 40mm diaUPVC pipes class III 6 Kg/cm2 with solvent cement joints confirming to IS 4985 forWash basin, Sink, Washing machine & Urinal outlets. The quoted rate shall includenecessary chisling in walls making goodthe same in C.M. 1:4, encasing the pipes in toilet sunken and under ground in M-15 asper specifications 100 mm thk. all around with necessary shuttering arrangement,necessary fittings viz.,elbows,tees etc.complete. 122 OD26990/2025-2026Supplying, laying, jointing, testing and commissioning approved make 50mm diaUPVC pipes class III 6 Kg/cm2 with solvent cement joints confirming to IS 4985 forWash basin, Sink, Washing machine & Urinal outlets. The quoted rate shallinclude necessary chisling in walls making goodthe same in C.M. 1:4, encasing the pipes in toilet sunken and under ground in M-15 asper specifications 100 mm thk. all around with necessary shuttering arrangement,necessary fittings viz.,elbows,tees etc.complete 123 OD26982/2025-2026Supplying, laying and jointing hard 75 mm dia (4kg / sq.cm) PVC pipes with PVCspecials such as tees, bends, door bend, door tee, elbow, unions, etc. with clamptesting the lines rectifying any leakages or defects etc. complete as directed by theEngineer in charge for soil, waste, vent pipe, etc. concealed or open at all levelsincluding cost conveyance of all materials , labour charges, sundries etc. complete forinternal work exposed on walls as directed by the Engineer in charge. 124 OD26991/2025-2026Supplying, laying and jointing hard 75 mm dia (6kg / sq.cm) PVC pipes with PVCspecials such as tees, bends, door bend, door tee, elbow, unions, etc. with clamptesting the lines rectifying any leakages or defects etc. complete as directed by theEngineer in charge for soil, waste, vent pipe, etc. concealed or open at all levelsincluding cost conveyance of all materials , labour charges, sundries etc. complete forinternal work exposed on walls as directed by the Engineer in charge. 125 OD26988/2025-2026Supplying, laying and jointing hard 110mm dia (6kg / sq.cm) PVC pipes with PVCspecials such as tees, bends, door bend, door tee, elbow, unions, etc. with clamptesting the lines rectifying any leakages or defects etc. complete as directed by theEngineer in charge for soil, waste, vent pipe, etc. concealed or open at all levels including cost conveyance of all materials , labour charges, sundries etc. complete forinternal work exposed on walls as directed by the Engineer in charge 126 OD26992/2025-2026Providing and fixing 100 mm dia gun metal gate valve with C.I. wheel ofapproved quality (screwed end) 127 OD26997/2025-2026Supplying and fixing of open well submerssible pump, with CI construction, CIimpeller complete with motor, base plate, foundation bolt, nuts, pressure guage andall accessories. And working with 415V, 3ph and 50hz frequency including costconveyance of all materials labour charge etc. complete as directed by the Engineer incharge at all levels Capacity 11.38m3/hr Head 11m 128 OD26994/2025-2026:Supply and fixing 160 mm sluice valve ( cast iron) 129 18.17.3Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end) :40 mm nominal bore 130 18.51.1Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore 131 ELECTRICAL WORKS 132 1.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C 133 1.11Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copperconductor single core cable in surface / recessed medium class PVC conduit, 2 waymodular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 134 1.17.12Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x2.5 sq. mm 135 1.17.21Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x4 sq. mm 136 1.17.3Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X1.5 sq.mm 137 1.17.30Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x6 sq. mm 138 1.17.31Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x6 sq. mm 139 1.21.1Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm 140 1.21.2Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.25 mm 141 1.24.1Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.5/6amps switch 142 1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch 143 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.3pin 5/6 amp socket outlet 144 1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.6pin 15/16 amp socket outlet 145 1.25Supplying and fixing two module stepped type electronic fan regulator on the existingmodular plate switch box including connections but excluding modular plate etc. asrequired. 146 1.26Supplying and fixing modular blanking plate on the existing modular plate & switchbox excluding modular plate as required. 147 1.27.2Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) 148 1.27.4Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) 149 1.28.2Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.3 Module 150 1.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ woodenblock including connection etc as required. 151 1.55.1Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. asrequired.Group A 152 1.55.2Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bellpoint ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. asrequired.Group B 153 1.55.3Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bellpoint ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. asrequired.Group C 154 90.10.1.3Supply & Fixing the following types/ sizes of boxes suitable for modular accessoriesin surface/ recess including making good the damages, colour washing etc as required(RoHS compliant )3 module moulded plastic box on surface 155 90.11.1.10Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth busand DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good thedamages, colour washing etc. as required4 way (8+12) - three phase double cover (IP42/43) 156 90.11.1.12Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth busand DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good thedamages, colour washing etc. as required8 way (8+24) - three phase double cover (IP42/43) 157 90.11.1.14Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth busand DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN verticalDB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/TP MCB as outgoing (IP 42/43) 158 90.11.1.18Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth busand DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good thedamages, colour washing etc. as required4 way (8+12) - double cover TPN verticalDB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP42/43) 159 90.12.1.28Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in ground includingexcavation of trench of size 35 x 75 cm, refilling the trench etc. as required butexcluding sand cushioning and protective covering (in ordinary soil).3.5 core 35 sqmm 160 90.12.1.36Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in ground includingexcavation of trench of size 35 x 75 cm, refilling the trench etc. as required butexcluding sand cushioning and protective covering (in ordinary soil).3.5 core 300 sqmm 161 90.12.1.40Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in ground includingexcavation of trench of size 35 x 75 cm, refilling the trench etc. as required butexcluding sand cushioning and protective covering (in ordinary soil).4 core 10 sq mm 162 90.12.1.41Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in ground includingexcavation of trench of size 35 x 75 cm, refilling the trench etc. as required butexcluding sand cushioning and protective covering (in ordinary soil).4 core 16 sq mm 163 90.12.7.28Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3.5 core 35 sq mm with factory madeclamp 164 90.12.7.30Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3.5 core 70 sq mm 165 90.12.7.32Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3.5 core 120 sq mm 166 90.12.7.34Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3.5 core 185 sq mm 167 90.12.7.35Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3.5 core 240 sq mm 168 90.12.7.36Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3.5 core 300 sq mm 169 90.12.7.40Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 170 90.12.7.41Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 171 90.4.5.4Supply, Installation, testing and commissioning of ceiling fan of following sizesincluding wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mmFRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cubmeter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper windingsuitable for 230V/240V single phase AC supply 172 1.50.1Installation of exhaust fan in the existing opening, including making good the damageconnection testing, commissioning etc. as required.Upto 450 mm sweep 173 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, C curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole 174 2.10.4Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, C curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole 175 2.3.3Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door 176 2.11Supplying and fixing single pole blanking plate in the existing MCB DB completeetc. as required. 177 2.13.2Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.63amps 178 9.1.21Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2X 35 sq. mm (32mm) 179 9.1.23Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.3 1/2X 70 sq. mm (38mm) 180 9.1.25Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.3 1/2 X 120 sq. mm (45mm) 181 9.1.27Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.3 1/2X 185 sq. mm (57mm) 182 9.1.29Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.3 1/2X 240 sq. mm (62mm) 183 9.1.30Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.3 1/2X 300 sq. mm (70mm) 184 9.1.32Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.4 X 10 sq. mm (25mm) 185 9.1.33Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.4 X 16 sq. mm (28mm) 186 OD27015/2025-2026Supplying and fixing of 240/415 V RCBOs suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.25A DP RCBO 30mA 187 OD27023/2025-2026Supplying and fixing of 240/415 V RCBOs suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.25A DP RCBO 25mA 188 OD27003/2025-2026Supplying and fixing of 240/415 V RCBOs suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.25A DP RCBO 100mA 189 OD27011/2025-2026Supplying and fixing of 415 V MCCBs suitable for inductive loadof following poles in the existing MCCB DB complete with connections,testing and commissioning etc. as required. 63A 16 KA FP MCCB 190 OD27013/2025-2026Supplying and fixing 4MD plexo box on surface/ recess IP 65 rated for fixing415V Isolator complete with connections, testing and commissioning etc. asrequired. 191 OD27007/2025-2026Supply of Steel-fabrication and installation for supporting electrical works / cabletrays etc., the quoted rate shall include two coats of primer and two coatsof enamel paint 192 OD27014/2025-2026Supply, fabrication & installation of following sizes of galvanized Perforatedtype cable trays from 2 mm thick GI sheets continuously connected includinghorizontal and vertical bends, reducers, tees and other accessories and duly suspended from the ceiling with min 12mm dia vertical GI threaded rods supported by 40mm x40mm x 5 mm Slotted frame etc. (or installed on wall supported on suitable bracketsas required) complete as per specifications, as required. 300 mm width X 60 mmdepth X 0.9 mm thickness 193 OD27008/2025-2026Supply, fabrication & installation of following sizes of galvanized Perforatedtype cable trays from 2 mm thick GI sheets continuously connected includinghorizontal and vertical bends, reducers, tees and other accessories and duly suspendedfrom the ceiling with min 12mm dia vertical GI threaded rods supported by 40mm x40mm x 5 mm Slotted frame etc. (or installed on wall supported on suitable bracketsas required) complete as per specifications, as required. 150 mm width X 60 mmdepth X 3000 mm cable tray 0.7 mm thickness 194 OD27019/2025-2026Supplying and fixing of 1.2m x 1.2m x 12.5mm CI Plate earth station inconformity with IS 3043. The earth resistance shall be less than 1 ohms.Additional earth stations/earth electrode if required to achieve the specifiedearth resistance value, the contractor shall provide the same with in the scopeof work. all works shall be carried out in conformaity with the specificationsand codes as required, approved and directed. 195 OD27025/2025-2026Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required. 3.15 mm copper conductor(10 SWG) 196 OD27017/2025-2026Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required.25 mm X 3 mm CU. Strip 197 OD27016/2025-2026Supply of LED surface mounted square down lighter housing made of diecast aluminium suitable for indoor applications with control gear and 18W LEDfixture with 1527 lm output having colour temperature of 5700 K , includingall connections as required.(Make - Wipro iris Slim LED or eq) 198 OD27002/2025-2026Supply of 18 / 20 Watt LED, Linear, Tube type Luminaire complete includingDriver complete as required. 199 OD26999/2025-2026Supply of LED surface mounted round down lighter housing made of diecast aluminium suitable for indoor applications with control gear and 12W LEDfixture with 1000 lm output having colour temperature of 5700 K , includingall connections as required.(Make - Wipro iris Slim LED or eq) 200 OD27006/2025-2026Supply of recess mounted LED light fixture of size 60x60 cm, housing made ofdie cast aluminium, suitable for indoor applications with control gear and 36WLED ,having colour temperature of 4000 K, 3640l m output , high efficiencydriver ,including all connections etc as required.(Make - Wipro Elate or eq) 201 OD27012/2025-2026Supply installation testing and commissioning of 80W LED Flood light made ofdie cast aluminium with high efficiency driver, IP 66 Protection, 8000 lumenoutput, colour temperature of 5700 K etc as required.(Wipro Alpha LED or eq) 202 OD27005/2025-2026Supply of 10W LED bulkhead light fitting housing made of Al Die castHousing powder coated, Polycarbonate opal diffuser, High efficiency, long life,LEDs, Dome with silicon gasket for IP65 Protection, IP65 - Dust, water andinsect proof. with duly wired up for use on 230 V AC. The fittings shall bedirectly on ceiling/ wall, including all accessories etc. as required. Make -Wipro LW07-141-XXX-57- XX or equivalent. 203 OD27004/2025-2026Supply of 10W LED mirror light, housing made of Co-extruded channelin thermally conductive material with plastic with IP 20 protection, have 900lumen output and 4700K colour temperature, operating frequency 50 ± 3%Hz, Beam angle 120 Deg, Efficiency of driver 85%, with duly wired up for useon 230 V AC etc. as required. Make - Wipro Trim LED neo or equivalent.. 204 OD27018/2025-2026Supply of following Exhaust fan in plastic frame working on 230 V A/C etcas required. 250 mm light duty exhaust in plastic frame.New 205 OD27022/2025-2026Metering Panel Fabrication, supply & installation of dust and verminproof, wall/ floor mounting cubicle construction made from 2 mm CRCA sheet,providing necessary supports made from the same gauge CRCA sheet to fixmeters, fuse units, CT, MCCBs etc, hinged door construction for the front sidewith compartments, knock out for cable entry and exit, painting the entireboard with 2 coats of synthetic enamel paint over a coat of zinc chromateprimer etc as required including fixing it on wall/floor, making good thedamages colour washing etc. as required. Comprising the following. 125ATPN SFU with Fuse, 125A COF and provision for Three phase metering withCTs ,(Rate of Energy meters and its CTs are not included in the estimate) 206 OD27026/2025-2026SSB Fabrication, supply & installation of dust and vermin proof, wall/floor mounting cubicle construction made from 2 mm CRCA sheet, providingnecessary supports made from the same gauge CRCA sheet to fix meters,fuse units, CT, MCCBs etc, hinged door construction for the front side withcompartments, knock out for cable entry and exit, painting the entire boardwith 2 coats of synthetic enamel paint over a coat of zinc chromate primer etcas required including fixing it on wall/floor, making good the damages colourwashing etc. as required. Comprising the following: Incomer : 125A 4PMCCB, Thermal Magnetic type. 25kA -1No Meters and indication lamps :RYB indication & MFM with control fuses, and CTs -1 Set, TVSS with controlfuses-1Set. Busbar : 25x10 mm Al busbars for 3 phases and 25x6mm Albusbar for Neutral. Outgoings : 63A TPN MCCB 16kA- 2Nos, 100ATPN MCCB 16kA -1No 40A TPN MCCB 16kA-2 Nos 207 OD27009/2025-2026AC Panel-1 Fabrication, supply & installation of dust and vermin proof,wall/ floor mounting cubicle construction made from 2 mm CRCA sheet,providing necessary supports made from the same gauge CRCA sheet to fixmeters, fuse units, CT, MCCBs etc, hinged door construction for the front sidewith compartments, knock out for cable entry and exit, painting the entireboard with 2 coats of synthetic enamel paint over a coat of zinc chromateprimer etc as required including fixing it on wall/floor, making good thedamages colour washing etc. as required. Comprising the following: Incomer : 200A 4P MCCB, Thermal Magnetic type. 25kA -1No Meters and indication lamps : RYB indication & MFM with controlfuses, and CTs -1 Set Busbar : 25x10 mm Al busbars for 3 phases and25x6mm Al busbar for Neutral. Outgoings : 63A TPN MCB 10kA9Nos 40A TPN MCB 10kA- 1No 208 OD27010/2025-2026AC Panel - 2 Fabrication, supply & installation of dust and vermin proof,wall/ floor mounting cubicle construction made from 2 mm CRCA sheet,providing necessary supports made from the same gauge CRCA sheet to fixmeters, fuse units, CT, MCCBs etc, hinged door construction for the front sidewith compartments, knock out for cable entry and exit, painting the entireboard with 2 coats of synthetic enamel paint over a coat of zinc chromateprimer etc as required including fixing it on wall/floor, making good thedamages colour washing etc. as required. Comprising the following: Incomer : 160A 4P MCCB, Thermal Magnetic type 25kA -1No Metersand indication lamps : RYB indication & MFM with control fuses, and CTs -1Set Busbar : 25x10 mm Al busbars for 3 phases and 25x6mm Al busbarfor Neutral. Outgoings : 63A TPN MCB 10kA- 9Nos 209 Utility Panel Fabrication, supply & installation of dust and vermin proof,wall/ floor mounting cubicle construction made from 2 mm CRCA sheet,providing necessary supports made from the same gauge CRCA sheet to fixmeters, fuse units, CT, MCCBs etc, hinged door construction for the front sidewith compartments, knock out for cable entry and exit, OD27001/2025-2026 painting the entireboard with 2 coats of synthetic enamel paint over a coat of zinc chromateprimer etc as required including fixing it on wall/floor, making good thedamages colour washing etc. as required. Comprising the following: Incomer : 100A 4P MCCB, Thermal Magnetic type 25kA -1No Metersand indication lamps : RYB indication & MFM with control fuses, and CTs -1Set Busbar : 25x6 mm Al busbars for 3 phases and 25x6mm Al busbar forNeutral. Outgoings : 63A TPN MCCB 16kA- 2Nos 40A TPN MCCB16kA- 4Nos 63A TPN Isolator 210 OD27020/2025-2026Supply, Installation, Testing and commissioning of 125A four polemotorized change over switch with controller including all connections etc asrequired. Make Socomec, L&T or equivalent. 211 OD27024/2025-2026Preparation of all drawings, submitting and getting approval fromElectrical Inspectorate, submitting of completion certificates and arranginginspection, getting sanction and energisation certificates from ElectricalInspectorate and commissioning of the whole installation in the premises. Allstatutory payments will be reimbursed on production of the original receipts.< 212 OD27021/2025-2026Preparation of all drawings, submitting and getting approval, arranginginspection<br>from KSEB, obtaining power allocation & permanentpowerconnection, etc. and<br>commissioning of the whole installation in thepremises.All statutory payments<br>will be reimbursed on production of the originalreceipts

Key Value

Document Fees
INR 5000 /-
EMD
INR 50000.0 /-
Tender Value
INR 1.60 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail