}

Tender For Supply, Installation, Testing And Commissioning Of Electrical Installation Work Of Library And Computer It Building At Coep Technological University, Pune., pune-Maharashtra

COEP technological University has published Tender For Supply, Installation, Testing And Commissioning Of Electrical Installation Work Of Library And Computer It Building At Coep Technological University, Pune.. Submission Date for this Tender is 28-08-2025. Electrical Maintenance Tenders in pune Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

50799832
Tender For Supply, Installation, Testing And Commissioning Of Electrical Installation Work Of Library And Computer It Building At Coep Technological University, Pune.
Tender
Indian
Maharashtra
Pune
28-08-2025

Tender Details

Supply, Installation, Testing And Commissioning Of Electrical Installation Work Of Library And Computer It Building At Coep Technological University, Pune.= 1 ELECTRICAL ITEMS 2 Supply,Installation,Testing & Commissioning of 8-Way VTPNDB with Provision for MCCB as Incomer with Door 1.2mm thickness Surface Mounted IP-43 Protection on Iron/GI Frame ( Vertical Bus Bar Type). 3 SWITCHGEAR MCCBS 4 Providing & erecting 4 Pole MCCB, 415V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 5 Supplying and erecting terminal spreaders suitable for 4 pole, above 100A up to 100A MCCB (Set of 8) 6 Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 100A MCCB. 7 Supply & Erecting of 40A FP RCBO 30mA.For Main UPS DB Incomer . 8 Supply & Erecting of 1-Phase Metal IK-08 16A Industrial Plug & Socket . 9 Supply & Erecting of 3-Phase Metal IK-0832A Industrial Plug & Socket. 10 Supply & Erecting of readymade hot dip GI perforated type trays of following size with 75 mm depth. 11 Supply & Erecting of readymade hot dip GI perforated type trays of 150 mm perforated tray 16 SWGsize with 75 mm depth. 12 Supply & Erecting of readymade hot dip GI perforated type trays of 300 mm perforated tray 16 SWGsize with 75 mm depth. 13 Supply & Erecting of readymade hot dip GI perforated type trays of 450x75 mm perforated tray 16 SWGsize with 75 mm depth. 14 Supply & Erecting of readymade hot dip GI. Ladder type tray, shall have 75mm C shape channel and rungs at 200 mm CC. 15 450 mm ladder tray 16 SWG. 16 Supplying, erecting, testing and commissioning of 15kVA capacitywith Golden / Unique Features of 15 KVA DXRT UPS. 1️ Common Battery Bank :- DXRT UPS models can share a common battery bank, offering flexibility for installations.2️ Hot Sync Feature for Parallel Redundancy :- Eliminates single points of failure between two or more UPS systems, even if the parallel cable is damaged or cut (e.g., by rodents). 3️ ABM Charging Method:- Advanced Battery Management (ABM) optimizes the cyclic charging process (charge, float, and rest). It reduces overcharging, prevents batteries from becoming bulky, and extends battery life by over 50%.4️ Flexible DC/Charging Current:-Eaton UPS systems adjust their charging capacity based on load requirements. When the load decreases, the UPS increases its charging capacity, enhancing battery performance, saving energy, and extending battery life.5️ Cybersecurity :-Communication cards are certified with UL 2900-1 and IEC 62443-4-2 standards, ensuring robust protection against cyber threats.with 0.9 to unity output pf, 3 phase input & 3 phase output complete with all protections as per specification no. AP-UPSRated input voltage3 phase 380/400/415V 3 Input voltage range 160V~300V full load 100~160V liner derating 4 Rated input frequency 50Hz/60Hz 5 Input frequency range 40 Hz– 70 Hz 6 Input frequency phase lock range 45 Hz– 55 Hz 54 Hz – 66 Hz 7 System compatibility TN-S / IT 8 Earth leakage current ≤7mA 9 Input power factor(PF)>0.995 .3 phase 10 Line break time without transfer to battery mode 4ms 11 Input voltage surge rating L-N: 405J L/N-GND: 445J 12 ≤3% linear load 13 ≤5% non-linear load 14 Input wiringL1+L2+L3+N+G 3 phase 15 Input connection Terminal block 16 Generator Set 2 times of UPS Rated Power Output 17 Phase connection Input-output3-3, 18 Rated output voltage. 3 phase 380/400/415V 19 Rated output frequency 50Hz/60Hz 20 Rated output appearance power 15KVA 21 Rated output active power 15KW 22 Max PF 1 23 Voltage variation ±1% 24 Frequency Variation ±0.1Hz 25 ≤1% linear load 26 ≤3% non-linear load 27 Performance classification VFI-SS-111 (not include ECO mode to inverter mode) 28 Load crest ratio ≥3:1 29 Break time 0ms (ESS mode to inverter mode 2ms, ECO to inverter mode 10ms) 30 Output voltage DC offset(Phase to Neutral) ±100 mV 31 Output voltage unbalance ≤3% 32 Output wiringL1+L2+L3+N+G 3 phase 33 Output connection Terminal block 34 105%<Load≤125%: 10min 35 125%<Load≤150%: 1min >150% :0.5s 36 105%<Load≤125%: 1min 125%<Load≤150%: 30s >150% :0.5s Detail Specification sheet for Eaton DXRT THDi THDV Overload capacity line mode (at rated voltage) Overload capacity battery mode (at rated voltage) 37 105%<Load≤125%: constant 125%<Load≤150%: 30s >150% :0.5s 38 Output short clearance capacity 22.7A±2A@10s Battery and charger 39 EBM UPS without build in battery. 2 EBM default. 40 EBM number maximum 6*2 41 Battery voltage ±192VDC default (±192V~±240V adjust) ANZ model ±240VDC default 42 Battery capacity 9AH 43 Backup time 2.8min/3.8min(±192V/±240V) at full load 44 Charging current 2A(0~13A adjust by LCD or USB/RS232) 45 Charging methord ABM 46 Temperature compensation 20mv/pcs/ ℃ 47 Battery ripple current (RMS) 17 Supplying and erecting of Double D-Hook,Fastners,Fan Rod upto-6ft & Fan Clamp etc. 18 Supply, installation, testing & commissioning ofOutdoor type ( IP-65/66),Guage 2mm Main HVAC Distribution Panel as described as aboveand as per specification complete in all respects.[NON CSR]HVAC MAIN DISTRIBUTION PANEL at TerraceIncoming from 630A Main LT Panel Feeder.One No. 630A FP MCCB, 36kA along with requires quantity of NO/NC contact terminal for PLC signal with an arrangement for cable connection on one side & bus-bars connection on other side. MCCBs shall be completed with all the in built protections and as required.( U/V,O/C,S/C,E/F etc ) Each Incoming Breaker Should be installed withDigital flush type class - I accuracy multifunction meter with 3 Nos. current transformers of 630/5 ratio, 10 VA Class 1.0 metering.6 nos NO/NC contacts for remote opening & closing.Red/Green/Amber ON/OFF/TRIP indicating lamps with 2A SP MCB backup protection.1 set of three phase indicating lamps along with 2A SP MCB backup protection.Spring charge & DC supply healthy indicating lamp with 2A SP MCB backup protection.Motor wound spring closing mechanism.Suitable arrangement to receive incoming cables.T-N-C Breaker control switch & RESET push button.Control fuses, control terminals & wiring as required.1 no.auto/manual selector switch.Bus Bars1sets of 800 AmpsTPN Aluminium Bus Bars of suitable length. Bus bars shall be colour coded and insulated by heat shrinkable sleeves & clip on shrouds for joints. Bus-Bars should be sized for a current carrying capacity of 1.0A/ sqmm.Outgoing FeedersEach Outgoing ACB/MCCB with standard protections shall be provided with the following :1 Sets of 3 Nos. phase indicating lamps suitable for 230 V/AC fittings with individually 6 A TP MCB back up.All outgoing feeders shall be provided with ON/OFF,Trip indicating lamps with 6 A DP MCB protection1 Nos. multi function meter with required CTs / PTs 3 Nos. phase indicating lamps suitable for 110 VAC fittings with 6 A DP MCB backup.630 A FP,415V, MCCB,36KA with Thermal Based release umit,O/L,S/C,U/V Protection -01 Nos.250 A FP 415V, MCCB,36KA with Thermal Based release umit,O/L,S/C,U/V Protection -01 Nos.Supply, installation, testing & commissioning ofOutdoor type ( IP-65/66) Main HVAC Distribution Panel as described as aboveand as per specification complete in all respects.[NON CSR] 19 Supplying and erecting PVC insulated PVC round sheathed 1.0 sq.mm (30 no. x0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 Kv. 20 Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 Kv. 21 Supplying and erecting integrated LED flood light fitting Max. 195W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. 22 Supply & Erecting of 36W, 6000k Linear 6-ft SuspendedLED Light Fitting Having Following technical Specification Nominal Wattages-36w,Rated Input Voltage-240Vac, Operating Votage Range-120-300Vac,Power Factor ->0.95,ITHD-<10%,Input Frequency -50Hz.Hi Pot Protection-1.5KVac,Driver Efficiency->88%,Surge Protection-4KV,High Voltage Cut Off ->310Vac-+10V,Over Voltage Prortection,Short Circuit Protection,Thermal Protection,Operating Mode-Constant Current,Luminux Flux Tolerance(-+10%)-3780,Beam Angle-110,Body atrial-Extruded Aluminium,Operating Temp.Range--10 to +40.Type ofProtection ( IP Rating) -IP-20. 23 Supply & Erecting of 20W,4000k Linear 4-ft SuspendedLED Light Fitting Having Following technical Specification Nominal Wattages-36w,Rated Input Voltage-240Vac, Operating Votage Range-120-300Vac,Power Factor ->0.95,ITHD-<10%,Input Frequency -50Hz.Hi Pot Protection-1.5KVac,Driver Efficiency->88%,Surge Protection-4KV,High Voltage Cut Off ->310Vac-+10V,Over Voltage Prortection,Short Circuit Protection,Thermal Protection,Operating Mode-Constant Current,Luminux Flux Tolerance(-+10%)-3780,Beam Angle-110,Body atrial-Extruded Aluminium,Operating Temp.Range--10 to +40.Type ofProtection ( IP Rating) -IP-20. 24 Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 3mm40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. 25 Supplying, erecting, testing and commissioning ofSPN D.B. with 40 Amp FP MCB - 1 no. as incoming and 40 Amp 300mAmp FP RCCB- 1no., 25 Amp 30mAmp DP RCCB- 1 no., 25 Amp DP MCB- 1no., 6 Amp DP MCB- 2 nos. as outgoing (i.e. 16 way SPN D.B.). -Lift DB. 26 Supply, installation, testing of set of Bulkhead fixture with 9 W LED Fittingand 1 No. 6/16A, 3 pin socket + 2 Nos switch on common good quality board in lift pit. 27 Supply, installation, testing of Two way light Point at Lift Pit.. 28 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU for LIft LIghting. 29 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU For Lift Power. 30 Supply, installation, testing of Cu.Earthing Bus Bar. 31 Supply,Installation Testing & Commissikoning of ACB 1250A 50KA FP EDO MP Based O/C,.S/C,/E/F protection make schneider.In the Existing Main IncomingPanel with necessary Followup /Coordination as Shutdown Work.CTs CL-1.0,15VA,Resin Cast 1250/5A.Multifunction Meter CT Short Links.R,Y,B,ON,OFF,TRIP Indication Lamp.CT Short Links.Control Glass fuse with base.Control Wiring.Copper Bus Bar EC Grade .Hardware.

Key Value

Document Fees
INR 1000 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail