Water Resources and Irrigation Government Departments Closing in 0 days TDR #50772324

Tender For Construction Of 02 Class Room In Gps Bhogpurdam Jaspur

Issued by Government Departments · jaspur, Uttarakhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
04 Sep 2025
0 days left
EMD
55200
Bank guarantee accepted
Document Fee
2360
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
jaspur → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of 02 Class Room In Gps Bhogpurdam Jaspur

BOQ

dk;Z dk uke%&jk0 izk0 fo0 HkksxiqjMke&tliqj esa 02 d{kk&d{k fuekZ.k
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
2Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
3Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
4Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
5Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
6Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
7Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
8Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb
9Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
10Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides
11Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
12Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
13Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
14Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
15Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
16Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
1712 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
1815 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand)
19Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
20Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
21Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
22Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
23Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
24Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
25Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
26Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
27Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
28Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
29Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
30Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Coupler110 mm
31Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :For 100 mm dia Pipe
32S/F of sign board including all cost.
33WGHTLPT Point wiring in PVC conduit, with modular type switch. Wiring for light point/ fan point/ exhaust fan point/ call bel point with 1.5 sq.mm FRLS PVC insulated copper conductor singlecorecableinsurface/recessedmediumclassPVC conduit, withmodularswitch,modularplate,suitableGIbox and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
34WGSTTLPP2 Powr plug wiring in pvc conduit (2x4sq.mm) Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
35WGSTLSB Circuit/ submain wiring in pvc conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/ recessed steel conduit required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.
36PVCCON S/F PVC CONDUIT: Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 25 mm
37PTSWEB S/F Modular type switch/ socket : Supplying and fixing following modular switch/ socket on the existingmodular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
38PTSWEB S/F Modular type switch/ socket : Supplying and fixing following modular switch/ socket on the existingmodular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outle
39MODFREB S/F modular type electronic fan regulator : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
40LPACCPT S/F light plug point modular type accessories : Supplying and fixing suitable size GI box with modular plate and Supplying and fixing suitable size GI box with modular plate and switch, connections etc. as required.
41PPACCPT S/F power plug point modular type accessories : Supplying and fixing suitable size GI box with modular plate and Supplying and fixing suitable size GI box with modular plate and switch, connections etc. as required.
42CREB S/F ceiling rose : Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
43BRHOLD S/F brass Holder : Supplyingandfixingbrassbatten/angle holderincluding connection etc. as required.
44ITCFFSUR ITCfluorescent fitting Directly on surface : Installation, testing and commissioningof pre wired, fluorescentfitting/compactfluorescentfittingofalltypes,completewithallaccessoriesandtube/lampetc.directlyonceiling/ wall, including connections with 1.5 sq. mm FRLS PVCinsulated, copper conductor, single core cable and earthing etc.as required.
45ITCCFFC ITC ceiling fan with cover on fan box : Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor,single core cable, includingprovidingandfixingphenoliclaminated includingprovidingandfixingphenoliclaminated sheet cover on the fan box etc. as required.
46MCBC S/F \"C\" Curve, SP MCB Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve,miniature circuitbreakersuitableforinductiveloadoffollowingpolesintheexistingMCBDBcompletewithconnections, testing and commissioning etc. as required. Single pole
47Supply of AC 230/250 Volts, 50 Hzenergy efficient ceiling fan with Standard down rod, blades,3 nos.caps Model- ES 50 (1200 MM Sweep) etc. complete, in all aspects as per direction of Engineer in charge. 1200 mm Sweep
48Supply and fixing on LED Tube light 1200 mm 20 W 865 T8 IP20, Lumen Output-1600, 3000,4000, 6500K ceiling mounted LED batten (E-Lite LED TRIYACA) extruded aluminium heat sink provided for efficient heat deissipation 7 & integrated electronic driver ( 1x20 W LED Double 6500K) complete in all aspects as per direction of Engineer in charge.
49SUPPLY OF LED Glass Bulb B22, 15 W, 600K / 4000K/3000K, 230/250 volt, 50 HZ etc. complete in all aspects as per direction of Engineer in charge.

AI Tender Summary

OUR REF NO 50772324
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 04-09-2025
Authority
Authority Name Irrigation Department
Work Description Construction Of 02 Class Room In Gps Bhogpurdam Jaspur
Basic Detail
Tender No 373/EE/MI/2025-26 dated 19/8/2025
Bidding Type Tender
Location
City jaspur
State Uttarakhand
Key Dates
Publish Date 20 Aug 2025
Submission Date 04 Sep 2025
Open Date 04 Sep 2025
Finance
Tender Value Ref. Documents
Tender Fee 2360
EMD 55200
Exemption Not Available
Document List
b5e53dfe-8ab1-405b-bc42-d3462f3f2489.html
BOQ_102563.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 20, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 04, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 04, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

b5e53dfe-8ab1-405b-bc42-d3462f3f2489.html

xls

BOQ_102563.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders