Tender For Repair/Maintenance Of Fans, Geysers, Solar Water Heater And Connected Works Under Ge Alwar; 1 Taking down carefully existing unserviceable water storage type electric geyser 25 litre capacity of any type & make from the wall after disconnecting water & electric connections and re-installation at the same location and testing, complete all as directed. Note : (i) The repair/replacement of unserviceable accessories/parts & painting shall be measured and paid for separately under the relevant items here-in-after.(ii) Tradesman with helper to be detailed by the contractor for collection of complaints from MES complain cell/ Service Centre Water supply daily in the morning and completion to be given after rectification of defect/repairs of geyser in the evening on same day to Engineer-in-Charge.(iii) Delay in rectification of the defects, will be panalised for every day from date of intimation of complaint to the contractor at Rs 500 per day. 2 S&F in repair apparatus plate (ISI marked) made of brass for water storage type electric geyser 25/50 litre capacity complete all as specified and directed. 3 S&F in repairindicator lamp green and red colour, square /round type as per existing with connection wire complete suitable for 25/50 ltr capacity geysers working on 230 volt AC supply, including Glass wool complete all as specified and directed. 4 S&F in repairwater vessel as per existing size and oval shape made of 22 SWG stainless steel sheet complete with flange for apparatus plate and vent pipe connection for 25 litre geyser, including Glass woolcomplete all as specified and directed. 5 S&F in repairwater vessel as per existing size and cylindrical shape made of 22 SWG stainless steel sheet complete with flange for apparatus plate and vent pipe connection for 25 litre geyser, including Glass wool complete all as specified and directed. 6 S&F in repairthermostatic switch (ISI marked) of range 0˚C to 75˚C suitable for 25/50 Litre capacity geyser complete all as specified and directed. Note- shape of heating element will be as per site requirenment. 7 S&F in repairheating element (round /triangula r/threaded/ hole type) of capacity 1.5 KW including rubber washer, bolts, clamps etc for geysers of 25/50 Litre capacity complete all as specified and directed. Note- shape of heating element will be as per site requirenment 8 S&F in repair heating element (round / triangular / threaded/ hole type) of capacity 2 KW including rubber washer, bolts, clamps etc for geysers of 25/50 Litre capacity complete all as specified and directed. Note- shape of heating element will be as per site requirenment 9 S&F in repair heating element (long sized, inbuilt in fiber body type) of capacity 1.5 KW including rubber washer, bolts, clamps etc for geysers of 25/50 Litre capacity complete all as specified and directed. Note- shape of heating element will be as per site requirenment. 10 S&F in repair heating element (long sized, inbuilt in fiber body type) of capacity 2 KW including rubber washer, bolts, clamps etc for geysers of 25/50 ltr capacity complete all as specified and directed.Make : Marc/Orient/Racold or equivalent. 11 S&F in repair pressure release valve/safety plug (spring loaded) brass chromium plated (ISI marked) for geysers of 25/50 Litre capacity complete all as specified and directed. 12 S&F in repairnon return valve brass chromium plated 15mm bore horizontal/vertical type (ISI marked) suitable for 25/50 Litre capacity geysers complete all as specified and directed.Note : The quoted rate shall deemed to include for opening of existing GI fitting and cutting and threading if required of existing pipe line for fixing of NRV. 13 S&F in repairPVC braided connection pipe 450 mm long suitable for 15 mm bore GI pipe including 2 Nos CP nuts & washers on both sides complete, suitable for hot water complete all as specified and directed. 14 S&F in repairPVC braided connection pipe 600 mm long suitable for 15 mm bore GI pipe including 2 Nos CP nuts & washers on both sides complete, suitable for cold water complete all as specified and directed. 15 S&F in repairbase (bottom) plate made of mild steel sheet as per existing pattern suitable for 25/50 Litre capacity geyser complete complete all as specified and directed. 16 M&L in repairs for galvanized steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. 17 M&L for removing unserviceable grouted Anchor type bolt & nuts from the wall and S&F new ‘Anchor’ type bolts & nuts (Set of 4 bolts of 10mm dia 150mm long with nuts & washers) into the wall grouted properly to hold the water storage type electric geyser of 25/50 litre capacity and making good the disturbed surface as original all as directed. 18 S&F in repair 15mm bore new stop valve fancy type of cast copper alloy chromium plated screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union complete all as specified and directed. 19 S&F in repair plug top 3 pin 15/16 Amp 230 volt AC, ISI marked, complete all as specified and directed. 20 S&F in repair new metal clad plug top and socket 3 pin 15/16 Amp 230 volt AC, ISI marked, complete all as specified and directed. 21 S&F in repair new plug top Single pole including neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 25 Amp, 240 Volt, complete all as specified and directed. 22 S&F in repairMCB, 32 Amps, Single Pole, 240 Volts, 10 KA complete all as specified and directed. 23 M&L Painting of Geysers after scraping & rubbing old surface and apply two coat of synthetic enamel paint of approved shade/tint on all steel surfaces all as directed by Engineer-in-charge. 24 S&F in repairs new outer cover of25 Litre Capacity geyser of suitable thickness includingtop & bottom cover and necessary accessories etc including oval or cylindrical shape as required on site complete all as specified anddirected. 25 S&F in repair PVC insulated flexible copper conductor cable 3 core of size 2.5 Sqmm (ISI marked), 1100 Volts, complete, complete all as specified and directed. 26 M&L for removal of blockage, choke ups of geyser of any capacity by removal of soild particles, corrosion/florides etc from the inlet/outlet/appratus plate complete with cleaning agent and testing including taking down geyser and refixing the sameat original position all as directed by Engineer-in-charge. 27 Taking down unserviceable geyser from existing place and deposite to MES E/M store and fixing only Geyser (water storage type) of capacity 25/50 litre vertical type including S&F ‘Anchor’ type /fastener type bolts & nuts (Set of 4 bolts of 10mm dia 150mm long with nuts &washers) into the wall grouted properly to hold the geyser and making good the disturbed surface as original all as per manufacturer’s instructions & as directed. 28 labour only for assembling all parts of geyser in a single body including outer cover and testing after assembling complete all as specified and directed 29 M&L for dismantling of unsv solar complete of any capacity with all connecting accessories and safely deposit to MES storeall as specified and directed. 30 S&F in repairs solar collector (Tube type) suitable for solar water heating system 200 LPD complete with collector box, absorber, sheet for absorber, collector box insulation, gasket, grommets and all other required connecting accessories and testing after completion all as specified and directed. 31 S&F in repairs solar collector (Tube type) suitable for solar water heating system 100 LPD complete with collector box, absorber, sheet for absorber, collector box insulation, gasket, grommets and all other required connecting accessories and testing after completion complete all as specified and directed. 32 M&L for PCC (1:3:6) type C1 using 40mm grade stone aggregate in foundation and mass concrete including necessary form work complete all as specified and directed by Engg in charge. 33 Material & labour for framed work, fabricated from structural steel sections including welding, bending, cold or hot, drilling holes for bolts, in any shape or size and as indicated or directed having MS angle on top for placing the collector panels/ water tank/supporting hot water pipes /ladders for approch etcinclusive of two coats of synthetic enamel paint over a coat of red oxide primer and fixing in walls/roof etc complete all as specified and directed by Engr-in-Charge. Note: Cost of taking down/dismantling is deemed to be included in quoted rates by contractor. 34 Servicing of complete solar flat plate collector/tube type collector. The detail scope of work consists of the following(i) Cleaning of solar flat plate collector with detergent and after that with coline solution and removing all type of grease/mud etc and cleaned as per direction.(ii) Cleaning of complete copper tubing system of solar flate plate collector incl necessary brazing welding if required/repair to leakage and tested as per OEM direction. (iii) Cleaning of hot water MS tank with cleaning agent and necessary gas welding/brazing if required to stope minor leakage. Note: Hose pipe clamps, nut, bolt, washer etc for replacement shall be measured and paid seprately under relevent item of this schedule. 35 Supply and fix in repair hose pipe clamps as per existing provncomplete all as specified and directed. 36 Supply and fix in repair Nut, M6 (Stainless steel) as per matching/ existing complete all as specified and directed. 37 Supply and fix in repair Bolt, M6 x 25, Hex Head (Stainless steel) as per matching/ existing complete all as specified and directed. 38 Supply and fix in repair washers, M6 x 25, Hex Head (Stainless steel) as per matching/ existing complete all as specified and directed. 39 Supply and fix in repairCollector Screws (Stainless Steel.) as per matching/ existing complete all as specified and directed. 40 Supply and fix in repair flat plate collector Gasket as per matching/ existing complete all as specified and directed. 41 S&F providing Glass wool insulation with cup wire mesh 100mm thick insulated covered by cladding of aluminium sheet 24 SWG on warm GI water line of 15/20mm size incl taking down old unserviceable material complete all as specified & as directed. 42 S&F in replacement of unserviceable 3KW heating element cum thermostat including connecting with electrical connections, for solar water heater complete all as specified and as directed. 43 S&F in replacement of unserviceable 2KW heating element cum thermostat including connecting with electrical connections, for solar water heater complete all as specified and as directed. 44 Supply and fixing in replacement of old flat plate solar collectors toughned GLASS for 100/200 LPDas per matching existing type, including all fixing accessories complete all as specified and as directed. 45 Supply and fixing in replacement of old flat plate solar collectors frame BOX 100/200 LPD, including all fixing accessories complete all as specified and as directed. 46 Supply and fixing in replacement of old flat plate solar collectors copper tubes absorber 100/200 LPD, including all fixing accessories complete all as specified and as directed. 47 Supply and fixing in replacement of flat plate solar collectors of suitable 100/200 LPD complete puff insulated collector accessories complete all as specified and as directed. 48 Supply, Installation, testing and commissioningin replacement of insulated hot water storage tank of stainless steel SS 304 tank 100 ltr 3 mm thick capacity heat exchanger type duly 100mm thick glass wool insulated covered by cladding of aluminium sheet 24 SWG including connecting all GI connections to the new SS tank with collector panels and MS stand of suitable thickness including heat exchanger water pot mounted on the top including taking out old U/S one complete all as specified and as directed by Engr-in-charge.Make: Surya shakti India Pvt Ltd or equivalent ISI marked. Note :-(a)The rate for taking downis deemed to fit in the quoted rate, no extra payment made on this account. (b) Any damage to the building while installing hot water storage tank should repaired in quoted amount, no extra payment made on this account. 49 Supply, Installation, testing and commissioningin replacement of insulated hot water storage tank of stainless steel SS 304 tank 200 ltr 3 mm thick capacity heat exchanger type duly 100mm thick glass wool insulated covered by cladding of aluminium sheet 24 SWG including connecting all GI connections to the new SS tank with collector panels and MS stand of suitable thickness including heat exchanger water pot mounted on the top including taking out old U/S one complete all as specified and as directed by Engr-in-charge.Make: Surya shakti India Pvt Ltd or equivalent ISI marked. Note :-(a)The rate for taking downis deemed to fit in the quoted rate, no extra payment made on this account. (b) Any damage to the building while installing hot water storage tank should repaired in quoted amount, no extra payment made on this account. 50 Supply, Installation, testing and commissioningin replacement of insulated hot water storage tank of stainless steel SS 304 tank 500 ltr 3 mm thick capacity heat exchanger type duly 100mm thick glass wool insulated covered by cladding of aluminium sheet 24 SWG including connecting all GI connections to the new SS tank with collector panels and MS stand of suitable thickness including heat exchanger water pot mounted on the top including taking out old U/S one complete all as specified and as directed by Engr-in-charge. Make: Surya shakti India Pvt Ltd or equivalent ISI marked. Note :-(a)The rate for taking downis deemed to fit in the quoted rate, no extra payment made on this account. (b) Any damage to the building while installing hot water storage tank should repaired in quoted amount, no extra payment made on this account. 51 M&L in replacement for rotational moulded polyethylene water storage tanks 500 litres (cylindrical vertical with closed top) hoisted and fixed in position with float valve all as specified in SSR Part I etc complete all as specified & directed. 52 Supply and fix push button (set of 4) of electric chimney complete all as specified and directed 53 Supply and fix blower of electric chimney complete all as specified and directed 54 Supply and fix LED light of 3 watt for electric chimney complete all as specified and directed 55 Material and labour for servicing of electric chimney incl cleaning of pipe,loose connection of blower etc copmlete all as specified and directed 56 Supply and fixing in repair1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overll PVC sheathed weather proof service connections one twin core cable flat or circular of aluminium, conductors size 10 Sqmm, stranded conductors. 57 S&F in repair sub main wiring on and includingpassing through in existing conduit pipe 1100 Volts grade with PVC flexible cable copper conductor unsheathed multistranded single core of size 6 sqmm and continuous earth with PVC flexible cable copper conductorunsheathed multistranded single core of size 6 sqmm of green colour confirming to IS 694/1990 including taking down existing U/S sub main wiring. (Note:Two runs of cable with one run of earth wire shouldmeasured as one length) 58 Supply, installation, testing and commissioning of solar water heating system suitable for inlet water with chlorine and fluoride content up to 100 PPM and comprising of solar flat plate collector ,collector stand assembly, stainless steel insulated hot water storage tank with heat exchanger of 200 liters per day capacitywith electric back up ,with collector A size aluminium box collector including solar flat plate collector,cover plate,hot water storage tank of 200 ltr incl stand of more than 10 feet height with MS frame and incl electrical backup of 3 KW heating element complete all as specified and directed 59 Taking down ceiling fan, any sweep including disconnection of electric connection and dismantling the blades and transporting and depositing to AGE E/M store yard for repair, maintenance, servicing, paintings etc. complete all as specified and as directed. 60 Collecting repaired, reconditioned, rectified etc. ceiling fan at AGE E/M store yard and transporting to the site and hanging ceiling fan and connecting up including provision of cable from ceiling rose, connectors to fan complete all as specified and as directed. 61 Taking down exhaust fan, any sweep including disconnection of electric connection and dismantling the blades and transporting and depositing to AGE E/M store yard for repair, maintenance, servicing, paintings etc. complete all as specified and as directed. 62 Collecting repaired, reconditioned, rectified etc. exhaust fan at AGE E/M store yard and transporting to the site and hanging exhaust fan and connecting up including provision of cable from ceiling rose, connectors to fan complete all as specified and as directed. 63 Taking down wall mounting fan, any sweep including disconnection of electric connection and dismantling the blades and transporting and depositing to AGE E/M store yard for repair, maintenance, servicing, paintings etc. complete all as specified and as directed. 64 Collecting repaired, reconditioned, rectified etc. wall mounting fan at AGE E/M store yard and transporting to the site and hanging wall mounting fan and connecting up including provision of cable from ceiling rose, connectors to fan complete all as specified and as directed. 65 Disassembling carefully ceiling fan (any make) of 1200 mm sweep and M & L for rewinding, overhauling and servicing of ceiling fan 230 volt, 50 Hz, AC by taking out existing stator, removing of burnt winding from stator and rewinding the same with new super enamelled copper wire of suitable size / gauge having class A insulation and weight not less than 275 gms including varnishing of winding, oiling of bushes, including lathe work and greasing of bearings repair the fan including necessary minor spares/items like PVC insulated copper wire of required size, screws, nuts, bolts, spring washer etc and reassembling, cleaning and testing complete all as specified and as directed. Note: spare part to be replaced shall be paid under respective items as S & F in repair. 66 Disassembling carefully exhaust fan (any make) of 300 mm sweep and M & L for rewinding, overhauling and servicing of exhaust fan 230 volt, 50 Hz, AC by taking out existing stator, removing of burnt winding from stator and rewinding the same with new super enamelled copper wire of suitable size / gauge having class A insulation including varnishing of winding, oiling of bushes, including lathe work and greasing of bearings repair the fan including necessary minor spares/items like PVC insulated copper wire of required size, screws, nuts, bolts, spring washer etc and reassembling, cleaning and testing complete all as specified and as directed. Note: spare part to be replaced shall be paid under respective items as S & F in repair. 67 Disassembling carefully exhaust fan (any make) of 450 mm sweep and M & L for rewinding, overhauling and servicing of exhaust fan 230 volt, 50 Hz, AC by taking out existing stator, removing of burnt winding from stator and rewinding the same with new super enamelled copper wire of suitable size / gauge having class A insulation including varnishing of winding, oiling of bushes, including lathe work and greasing of bearings repair the fan including necessary minor spares/items like PVC insulated copper wire of required size, screws, nuts, bolts, spring washer etc and reassembling, cleaning and testing complete all as specified and as directed. Note: spare part to be replaced shall be paid under respective items as S & F in repair. 68 Disassembling carefully wall mounted fan (any make) of 450 mm sweep and M & L for rewinding, overhauling and servicing of wall mounted fan 230 volt, 50 Hz, AC by taking out existing stator, removing of burnt winding from stator and rewinding the same with new super enamelled copper wire of suitable size / gauge having class A insulation including varnishing of winding, oiling of bushes, including lathe work and greasing of bearings repair the fan including necessary minor spares/items like PVC insulated copper wire of required size, screws, nuts, bolts, spring washer etc and reassembling, cleaning and testing complete all as specified and as directed. Note: spare part to be replaced shall be paid under respective items as S & F in repair. 69 S & F in repairs capacitor 2.5 mfd to 3.15 mfd dry type with PVC clamp for ceiling fan complete all as specified and as directed.Make-Epcos/Havells/Tibcon 70 S & F in repairs Ball Bearing No 112/6201 for ceiling fan/exhaust fans/ wall mounted fans complete all as specified and as directed.Make- NBC or equivalent in make SKF/FAG/TATA. 71 S & F in repairs Ball Bearing No 115/6202 for ceiling fan/exhaust fans/ wall mounted fans complete all as specified and as directed.Make- NBC or equivalent in make SKF/FAG/TATA. 72 S & F in repairs Ball Bearing No 117/6203 for ceiling fan/exhaust fans/ wall mounted fans complete all as specified and as directed.Make- NBC or equivalent in make SKF/FAG/TATA. 73 S & F in repairs Ball Bearing No 117/6204 for ceiling fan/exhaust fans/ wall mounted fans complete all as specified and as directed.Make- NBC or equivalent in make SKF/FAG/TATA. 74 S & F in repairs step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed.Make : Havells/Anchor/Orient 75 S & F in repairs heavy duty H clamp complete with rubber real, bolt nut, split pin complete all as specified and as directed. 76 S & F in repairs PVC canopy set (upper & lower) for ceiling fans of any sweep and make and fixing in position complete all as specified and as directed. 77 S & F in repairs mild steel blades of ceiling fan of sweep 1200 mm including nuts and bolts for fixing blades complete all as specified and as directed. 78 Supply and fixing as in repair Down Rod from Hanging Point to Ceiling Fan base upto length 600 mm suitable for 48/56 sweep ceiling fan (As per Sample/site reqmt) 79 S & F in repairs motor of exhaust fan PVC body of 200 mm sweep, 230 Volt, 50 Hz complete all as specified and as directed.Make : Havells/Bajaj/Crompton 80 S & F in repairs steel shaft suitable for ceiling fan/exhaust fan/wall mounted fan of any sweep and any make/model with necessary works (cutting, grouting, lathing finishing etc) complete all as specified and as directed. 81 S & F in repairs nut and bolts of any size, type complete all as specified and as directed. 82 S & F in repairs ceiling fan mild steel body set (upper & lower) for ceiling fans of any sweep and make and fixing in position including nuts and bolts for fixing blades complete all as specified and as directed.Make :-Orient/Bajaj/Khaitan/Usha 83 S & F in repairs ceiling fan rotor of 1200 mm sweep complete with copper winding wire complete all as specified and as directed.Make :-Orient/Bajaj/Khaitan/Usha 84 S & F in repairs magnetic ring of ceiling fan of 1200 mm sweep complete all as specified and as directed.Make :-Orient/Bajaj/Khaitan/Usha 85 S & F in repairs motor of exhaust fan (metal body) of 450 mm mm sweep complete all as specified and as directed.Make : Havells/Bajaj/Crompton 86 S & F in repairs motor of exhaust fan (metal body) of 300 mm mm sweep complete all as specified and as directed.Make : Havells/Bajaj/Crompton 87 S & F in repairs motor of exhaust fan (metal body) of 230 mm mm sweep complete all as specified and as directed.Make : Havells/Bajaj/Crompton 88 S & F in repairs mild steel blades of exhaust fan of sweep 450 mm including nuts and bolts for fixing blades complete all as specified and as directed.Make : Havells/Bajaj/Crompton 89 S & F in repairs mild steel blades of exhaust fan of sweep 300 mm including nuts and bolts for fixing blades complete all as specified and as directed.Make : Havells/Bajaj/Crompton 90 S & F in repairs mild steel blades of exhaust fan of sweep 230 mm including nuts and bolts for fixing blades complete all as specified and as directed.Make : Havells/Bajaj/Crompton 91 S & F in repairs mild steel frame of exhaust fan of sweep 450 mm complete all as specified and as directed. 92 S & F in repairs mild steel frame of exhaust fan of sweep 300 mm complete all as specified and as directed. 93 S & F in repairs mild steel frame of exhaust fan of sweep 230 mm complete all as specified and as directed. 94 S & F in repairs leg set including nut bolts & rubber washer of exhaust fan(metal body) of sweep 450 mm complete all as specified and as directed. 95 S & F in repairs leg set including nut bolts & rubber washer of exhaust fan(metal body) of sweep 300 mm complete all as specified and as directed. 96 S & F in repairs leg set including nut bolts & rubber washer of exhaust fan(metal body) of sweep 230 mm complete all as specified and as directed. 97 S & F in repairs louvers/shutters suitable for existing exhaust fan(metal body) of sweep 450 mm complete all as specified and as directed. 98 S & F in repairs louvers/shutters suitable for existing exhaust fan(metal body) of sweep 300 mm complete all as specified and as directed. 99 S & F in repairs louvers/shutters suitable for existing exhaust fan(metal body) of sweep 230 mm complete all as specified and as directed. 100 S & F in repairs motor of exhaust fan(plastic/ PVC body) of sweep 250 mm complete all as specified and as directed.Make : Havells/Bajaj/Crompton 101 S & F in repairs fan blade of exhaust fan PVC body of 250 mm sweep, 230 Volt, 50 Hz complete all as specified and as directed. 102 S & F in repairs frame with leg set of exhaust fan PVC body of 250 mm sweep, 230 Volt, 50 Hz complete all as specified and as directed. 103 S & F in repairs louvers of exhaust fan PVC body of 250 mm sweep, 230 Volt, complete all as specified and as directed. 104 S & F in repairs fan blade of exhaust fan PVC body of 200 mm sweep, 230 Volt, complete all as specified and as directed. 105 S & F in repairs frame with leg set of exhaust fan PVC body of 200 mm sweep, 230 Volt, complete all as specified and as directed. 106 S & F in repairs louvers of exhaust fan PVC body of 200 mm sweep, 230 Volt, complete all as specified and as directed. 107 S & F in repairs motor of wall mounted fan including motor housing, rear motor cover and shaft of 300 mm sweep, 230 Volt, complete all as specified and directed.Make : Havells/Bajaj/Crompton 108 S & F in repairs wall mount bracket of wall mounted fan including motor housing, rear motor cover and shaft of 300 mm sweep, 230 Volt, complete all as specified and directed 109 S & F in repairs speed control knob, speed control pull and oscillation control pull of wall mounted fan including motor housing, rear motor cover and shaft of 300 mm sweep, 230 Volt, complete all as specified and directed 110 S & F in repairs front & rear grill including lock nut, ring clip, screw etc. of wall mounted fan including motor housing, rear motor cover and shaft of 300 mm sweep, 230 Volt, complete all as specified and directed 111 S & F in repairs fan blade of wall mounted fan including motor housing, rear motor cover and shaft of 300 mm sweep, 230 Volt, complete all as specified and directed 112 S & F in repairs Modular fan regulator, 120 W, 2 modules complete all as specified and as directed.Make- Havells/Anchor/Orient