| 1 | NOTE (Applicable for all items):- The bidders/contractorsare advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entrying/quoting the rates.SCHEDULE \"A\" |
| 2 | M & L for surface dressing n.exc 15 cm deep in soft/loose soil, complete all as specified and as directed. |
| 3 | Excavating over areas n.exc 1.5m deep and getting out, complete all as specified and as directed. |
| 4 | Removing excavated material n.exc50 m and depositing where directed at a level n. exc. 1.50 m above the starting point complete all as specified and as directed. (4125.00+503.95) |
| 5 | Rolling and consolidating of formation surfaces in cutting by Power roller exc. 8 tonne and n.exc 12 tonne, complete all as specified and as directed. |
| 6 | M & L for soling (or sub-base) 150 mm spread thickness with broken boulders or quarried stone (size 50mm to 100mm) (granite, trap or basalt), interstices filled, surfaces formed and rolled and consolidated with power roller 8 to 12 tonne to required gradient and camber, complete all as specified and as directed. |
| 7 | M & L 150 mm thick in two layers (each layer of 75mm thick) (compacted thickness) WBM, with Limestone, sand stone, Flint or Quartzite with coarse aggregates of grading 2 (63 to 45 mm size) spread rolled and compacted to required gradient and camber with three wheel power roller of 80 to 120 KN capacity of an equivalent vibratory roller, complete all as specified and as directed. |
| 8 | M & L for preparing of unsrfaced water bound macadam road surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all those dirt etc. Applying evenly a priming/tack coat with bituminous primer at 7.5 Kg per 10 Sqm, complete all as specified and as directed. |
| 9 | M & L for Premix bituminous macadam @ 4% paving bitumen content laid/rolled and compacted to required gradient and camber (consolidated thickness 75mm or less), complete all as specified and as directed. |
| 10 | M & L for preparing BM surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc., applying evenly a priming /rtack coat with bituminous primer at 2.5 Kg per 10 Sq metre, complete all a specifed and as directed. |
| 11 | Bituminous premix asphaltic dense concrete 40 mm consolidated thickness with 5.5% binder content by weight of total mix, rolled and compacted to required camber and gradient, complete all as specifed and as directed. |
| 12 | M & L shingle filling in floors or pavings, laid in layers n.exc 15 cm thick, spread, levelled, and blinded with earth and rammed including watering, complete all as specified and as directed. |
| 13 | Providing and applying 2.5 mm thick road marking strips (retroreflective) of specified shade/colour using hot thermoplastic material by fully/semi-automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank and profile shoe heater, driven by experienced operator on road surfaceincluding cost of material, labour, T& P, cleaning the road surface of all dirt, seats, cil, grease etc., complete all as specified and as directed. |
| 14 | M & L for continuous brick edging/PCC Block with width equal to the depth of the brick, laid dry, on edge with burnt clay bricks of sub-class \"B\" old size bricks, complete all as specified and directed. |
| 15 | Supply and fixing cat eye solar reflective type of metal body alloy of size 100mm x 100mm x 20 mm with PAMA stiplens reflector of model No. DA 972 0 fixed with and including MS stud of suitable size as per manufacturers instructions, complete all as specified and as directed. |
| 16 | Supply and fix solar cat eye aluminium alloy shall (100% water proofing design according to 65) of size 125 mm x 125mm x 25mm (shank 65 mm) of high efficiency Mono rystafie solar panel 2.4V/0.3 Watt one NI-ed rechargeable battery (1.2V/1600 MA) consistingof super bright light LED with 10, 000 to 18,000 mcd completed as per manufacturers instructions etc., complete all as specified and directed. |
| 17 | Supply and fixing metal tubular delineator made out of ABS round body fitted with 2 Nos 65 mm dia hightly reflective reflectors made out of PMMA and mounted on 45/50 mm dia mild steel pipe of 600 mm height duly powder coated and thermo plastic elastomer 3 bands of greeen, red and yellow relfector radium tape of 25 mm wide stripss with anti theft steel net for reflector protection including embedding in PCC (1:2:4) (150x150x300mm) type B1, complete all as specified and as directed. |
| 18 | Forming embankmens including raising (or lowering) earth, spreading in layers n.exc 30cm, thick, watering, ramming/rolling and finishing to required size, shape, etc., n.exc 1.5m high from base, complete all as specified and as directed |
| 19 | Ecavation in trenches n.exc 1.5 m width and n.exc 1.5m in depth and getting out in soft/loose soil for laying /taking out of LT UG cable, complete all as specified and as directed. |
| 20 | Excavation trenches, n.exc 1.5m wide and exceeding 1.5m deep and not exc 3 mtr deep for excavation of poles and getting out in any type of soil, complete all as specified and as directed. |
| 21 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in soil, complete all as specified and as directed. |
| 22 | Removal of surplus soil to a distance n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 m above the starting point. |
| 23 | M & L for sand cushioning using dry and clean tibba sand in two layers, first layers of 80 mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers, complete all as specified and as directed. Note: Puned sand thickness shall only be measured and paid. |
| 24 | Supply and laying well burnt bricks, locally available best quality (sub class \"B\" bricks ) laid in trenches perpendicular to underground cable for cable protection, complete all as specified and as directed. |
| 25 | Supplying, erecting and fixing steel tubular swaged poles with cast iron base plate of size 300 mm x300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-22 (8.5 metres long including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and rarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30 cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and bumbering of poles, in yellow paint over black painted back ground at a height of 2 m from bottom of pole with 5 cm large bold letter 2\" (inch) wide, complete all as specified and as directed. Note: (Excavation, earthwork, PCC in foundation and coping shall be measured and paid for separately under relevant item here-in-after) |
| 26 | M & L for cement concrete type B1 (1:2:4) using 20 mm graded stone aggregate as in foundation, stay concrete etc., complete all as specified and as directed. |
| 27 | M & L for cement concrete type B1 (1:2:4) using 40 mm graded stone aggregate as in foundation, stay concrete etc., complete all as specified and as directed. |
| 28 | M & L for plain cement concrete type C1 (1:3:6) using 20 mm graded stone aggregate as in coping, including necessary formwork and finishing exposed surface/white washing, complete all as specified and as directed. |
| 29 | S & F pole mounted shock and rust proof junction box rectangular shape, 4 way of size 240x130x110 mm outdoor type including fixing with two nos flat iron clamps of suitable size with necessary mild steel nuts and bolts, complete all as specified and as directed. Make:- Cat Part No. GS-JB2817 of Sintex/Hensel or of any equivalent as approved. |
| 30 | S & F LED street light fitting of high-quality group control enabled integrated LED Street Light with minimum system lumen of min 8400 lm and system wattage not less than 60 W with a nominal system efficacy of 140 lumen/watt. The LED used shall bave CCT of 5700K, SDCM ≤ 5 and CRI ≥ 70. The housing should be made of LM6/ADC 12 Alloy, non-corrosive single piece pressure die-cast aluminium, to withstand extreme environments. The spigot shall be part of \"Single Piece Pressure Die-Cast housing\" & shall not be bolted to the luminaire housing to ensure bobust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The Luminaire LED shall have declared lifetime of 50K hours @ L7B50. The product should be designed for continuousoperation (10-12 Hrs per day). The Ingress protection should be minimum IP66 & impact resistant shall be IK10. Control gear compartments shall be top maintanable without accessing/operating the optical compartment. The Luminaire should have a minimum 20 KV/10KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10 KA rating. i.e total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall have operating voltage of 120V to 270V, PF ≥ 0.95 @ full load, THD ≤ 10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs, should have an auto shutdown @ 325V (± 15V) and have an auto recovery feature. The driver shall comply to IEC 61547 & IEC 61000-3-2. |
| 31 | M & L street light bracket made out of 150 cm long, 32mm dia light grade GI pipe with provision of nut and bolts for fixing on top of the pole duly painted with two coats of silver paint over a coat of red oxide primer, complete all as specified and as directed. |
| 32 | S & F (FRLS) PVC insulated and PVC round unsheathed multistranded copper conductor flexible cable of size 1.5 Sqmm x 3 core, complete all as specified and as directed. Make: Havells/Plaza/Finolex. |
| 33 | Supply and laying XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade of size 95 Sqmm x 3.5 core, complete all a specified and as directed. |
| 34 | Supply and laying XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade of size 35 Sqmm x 4 core, complete all a specified and as directed. |
| 35 | Supply and laying XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade of size 25 Sqmm x 3.5 core, complete all a specified and as directed. |
| 36 | Supply and laying XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade of size 16 Sqmm x 3.5 core, complete all a specified and as directed. |
| 37 | Supply and laying of GI tubing light grade, of size 50mm dia bore, in protection of cable at road crossing/hard standing/poleprotection fixed with clamps as per site requirement etc., all as specified and as directed |
| 38 | Supply and laying of GI tubing light grade, of size 40mm dia bore, in protection of cable at road crossing/hard standing/poleprotection fixed with clamps as per site requirement etc., all as specified and as directed |
| 39 | Cutting the existing road/footpath/hard standing/drain straight manually for50/80 mm dia bore, depth not less than 1 metre below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete (1:2:4) (using 20 mm graded stone aggregate), complete all as specified and as directed. |
| 40 | M & L earthing with Galvanised Earth Plate electrode 600x600x6.0 mm thick, burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected with and including GI pipe 15mm bore (dia) light grade,connected to test point upto 7.50 metre away from Earth Electrode situated, Earth plate surrounded by a packed thickness of charcoal or coke dust mixed with common slat in alternate layers of n.exc 150mm thick, PCC pit in cement concrete (1:3:6) (20 mm graded stone aggregate) and precast RCC cover slab of size 350x350x50 mm in cement concrete (1:2:4) (20 mm graded stone aggregate), reinforced with 10mm dia TMT bars @ 100 mm centre to centre in both ways, GI wire mesh, PGI funnel with GI watering pipe 20 mm bore (dia) medium grade including necessary excavation in soft/loose soil, returning, filling in and removal of surplus soil upto a distance of 50 metre and all as shown in Electrical plage No. 3 of MES, Schedule Part-I and testing on completion, complete all as specified and as directed. |
| 41 | Labour for dismantling of ACSR or AAC conductors and keeping aside for further disposal or to issue under Schedule of Credit to the contractor. |
| 42 | Dismantling concrete poles/struts, any size, transporting to store and stacking aside for further issue under schedule of credit to the contractor. |
| 43 | Supply and lay XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade of size 240 Sqmm x 3.5 core, complete all as specified and as directed. |
| 44 | M & L for stay assembly having diameter of stay rod 20 mm, complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately), complete all as specified and as directed.. |
| 45 | Material & Labour for earthing complete with galvanised steel earth plate electrodesize 600x600x6 mm thick burried directly in groundvertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to machinery/equipment etc., andincluding galvanised iron strip 32x6 mm earth lead by means of bolts, nuts, check nuts and washers, protected with and including 50mm dia light grade GI pipe, 20 mm dia GI pipe (Medium grade) for watering, necessary earthwork. PCC (1:3:6) type C1 concrete pit, RCC (1:1½ : 3) type A1 precast cover (54x54x5 cm) duly reinforced with and including 8 mm dia TMT bar @ 150 mm c/c both ways, one lifting handle made of 8mm dia TMT bar, embedded in pre-cast cover slab all asspecified and as shown in electrical plage No.3 of SSR Part-I including testing on completion, complete all as specified and as directed. |
| 46 | Supply and installation CPRI approved LT Electric control panel, cubical type, for outdoor use, double door dust & vermin proof floor mounted made out of CRCA steel sheet of 3.15 mm thick and 2.00 mm thick other parts and angle iron legs of size 50mmx50mmx6mm having front and rear hinged doors with front openable shutters for each MCCB/Change over with spreader & extended rotary handle having hinges on one side and locating arrangements with screws type on other sides completely with fully enclosed bus bar chamber, having electrolytic high conductivity insulated bus bar made out of aluminium strips of rating 200 Amps for 3 Phase, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly painted with two coats of stove enamelled powder coated paint over as coat of redoxide primer complete all as including necessary PCC work of height 45 cm from the ground level, all as specified and directed of suitable size for accomodating following accessories:- INCOMING:(i) MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 25 kA- 01 No. (ii) Digital Ammeter 0-300 Amps CT Operated with selector switch - 01 No. (iii) Digital Voltmeter 0-500 Volts with selector switch - 01 No.(iv) LED indicator lamp in three colour RYB - 01 Set of 3.OUTGOING:(i)MCB 4 Pole, 415, Adjustable tpe, 40 Amps with breaking capacity 16 kA - 02 No (ii) Astronomical timer of suitable rating alongwith contactor, MCB, total switch for Auto/Manual control etc. complete pre-wired - 01 No. |
| 47 | Supply, installation, testing and commissioning complete of manufacturer of OEM manufactured, static silent (Sound proof enclosure) Diesel Engine Driven Generating Set capable of delivering 12 KW (15KVA), 415 Volts (AC three phase, 4 wire system of supply) 50 Hz at power factor 0.8 minimum. The DG set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arranement, exhaust pipe complete and suitable for conditions prevalent at Likabali, Assam (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height)_ or as per OEM\"s recommendation, anti-vibration pads, including all features to comply with latest CPCB-IV guidelines and comprising of followings:- |
| 48 | (i) ENGINE (Prime Mover): Diesel Engine 1500 RPM, direct injection, 6 cylinders, four stroke, radiator cooled, performance class of generator set ISO 8528-5 G2, turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 12 KW (15KVA) at outdoor atmospheric conditions at Dinjan, (Taking all derating factor into consideration), 12/24 Volt (as per manufacturer recommendations) electric battery start including suitable size battery, complete with fly wheel all standard fittings/fixtures as per manufacturer and including suitable panelwith tachometer, lube oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumable etc. |
| 49 | (ii) ALTERNATOR: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire rated for output of 8 KW (10 KVA), Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class \"H\", salient pole, revolving field, sealed bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine. |
| 50 | (iii) BASE PLATE: Made out of structural steel as per manufacturer\"s recommended design/specifications. |
| 51 | (iv) ACCOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB(A) at a distance of 1 M at 75% load under field condition. |
| 52 | (v) FOUNDATION/PLINTH/BASE: Shall be provided as per manufacturer recommendations, however minimum 0.5 m space should be available all around the set and height of plinth shall not be less than 0.5 M. |
| 53 | (vi) DIESEL STORAGE TANK: of capacity adequate for storage of diesel as per manufacturer specification. |
| 54 | (vii) AMF PANEL: Microprocessor/Relay based pedestal mounted indoor use AMF control panel of suitable rating made up of 3 mm thick CRCA sheet steel enclosure with power coated double contactor type for mains and alternator with necessary aluminium bus bar for 3 phase, 4 wire system including necessary relays, timer, fuses, interconnection copper cabling work including fixing on floors by grouting, PCC work complete. (a) MCCB of suitable rating wirh short circuit protections - 1 No.(b) Digital multifunction meter of size 96x96 mm to measure current, voltage, KW, frequency and power factor with built in selector switch and programmable CT ratio with RS 485 port(c) Phase indicating lamps (R-Y-B) - 1 Set.(d) All standard relays, circuits and protection required for automatic operation of Gen set(e)Data logging: Engine hours, Control hours and upto 5 recent fault codes(f) AC Alternator Protection: Over/under Voltage, Over/under frequency, Loss of AC sensing, Over speed, Over current, KW Overlead |
| 55 | (viii) MISC: Tool kit, Operation and maintenance catalogue, spare part list, overhauling manuals, guarantee card etc., shall be provided as per manufacturer standard practices. |
| 56 | (ix) FIRST FILL OF LUBRICANTS, COOOLANT & FUEL:-First fill of oil, coolant as per OEM recommendations and diesel during testing for 12 hrs as per CA provisions.Note: PCC foundation for DG set shall be deemed to be included in the rate quoted for all DG sets:- (a) DHPP for testing purpose shall be supplied by the contractor without any extra cost to the Department. (b) The contractor shall arrange for artifical load (water load/Electrical load) for testing for final testing of DG set at site and the cost is deemed to including in above offer. (c) Testing of sound level should be carried out at the site in presence of Engr-in-Charge.(d) One set of latest spare part catalogue with price, exploded view of parts and user\"s manual are deemed to be included in the offer.(e) All civil works inlcluding foundation for DG set as per mnufacturer\"s drawing/specification, foundation for AMF panel.(f) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level. |
| 57 | M & L for Earthing complete with copper earth plate electrode 600x600x3.15 mm thick, burried directly in ground (earth pit not less than 2.25 mm deep below ground level) with top edge of the plate not less than 1.5 metre deep below normal ground level, connected to machinery equipment etc and including copper strip 20x3 mm dia as earthing lead by means of bolts, nuts, check nutss and washers, protected with and including 50mm dia light grade GI pipe, 20 mm dia GI pipe (medium grade) for watering, necessary earthwork, PCC (1:3:6) type C1 concrete pit, RCC (1:1½ :3) type A-1 pre-cast cover (54x54x5cm) duly reinforced with and including 8mm dia TMT bar @ 150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar, embedded in pre-cast cover slab all as specified and shown in electrical plate No.3 of SSR Part-I including testing on completion complete all as specified and as directed. |