Tender For Electrical Works In Improvement And Upgradation Of Medicine Wards At Govt. Smhs Hospital Srinagar, srinagar-Jammu And Kashmir

Public Works Department has published Tender For Electrical Works In Improvement And Upgradation Of Medicine Wards At Govt. Smhs Hospital Srinagar. Submission Date for this Tender is 28-08-2025. Electrical Maintenance Tenders in srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

50764011
Tender For Electrical Works In Improvement And Upgradation Of Medicine Wards At Govt. Smhs Hospital Srinagar
Tender
Indian
Jammu And Kashmir
Srinagar
28-08-2025

Tender Details

Tender For Electrical Works In Improvement And Upgradation Of Medicine Wards At Govt. Smhs Hospital Srinagar- 1 Wiring for light point/ fan point/ exhaust fan point/ call bell pointwith1.5sq.mm FRLSPVC insulatedcopper conductor singlecorecableinsurface/recessedmediumclassPVC conduit, with modular switch, modular plate, suitable GI box andearthingthepointwith1.5sq.mmFRLSPVCinsulated copper conductor single core cable etc. as required as per IS Standard. 2 Group‐B (Primary point ) 3 Wiring for group controlled (looped) light point/ fan point/ exhaust fan point/ call bell point (without independent Switch etc.)with1.5sq.mm FRLSPVC insulatedcopper conductor singlecorecableinsurface/recessedmediumclassPVC conduitandearthingthepointwith1.5sq.mmFRLSPVCinsulated copper conductor single core cable etc.as per IS Standard. 4 Group‐B 5 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 6 Group‐B 7 Supplyingandfixingmodularblankingplateontheexisting modularplate&switchbox excludingmodular plateas requiredas per IS standard 8 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing andfixing3pin5/6Amodularsocketoutletand5/6A modular switch, connections etc. as required. 9 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). 10 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6& 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.as per IS standard 11 Supplying and fixing following modular switch/ socket on the existingmodularplate&switchboxincludingconnections but excluding modular plate etc. as required. 12 3 pin 5/6 A socket outlet 13 5/6 A switch 14 6 pin 15/16 A socket outlet 15 15/16 A switch 16 Supplying and fixing following piano type switch/ socket on theexisting switch box/ cover including connections etc. as required 17 5/6 amps switch 18 2 way 5/6 A switch 19 15/16 A switch 20 3 pin 5/6 A socket outlet 21 6 pin 15/16 A socket outlet 22 5/6A2 Pin TOP 23 5/6A3 Pin TOP 24 16 A TOP 25 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, singlecorecableinsurface/recessedmediumclassPVC conduit as required (partially laid Conduit in slab)as per IS Standard. 26 2X1.5sq.mm+1X1.5sq.mmearthwire. 27 2X2.5sq.mm+1X2.5sq.mmearthwire. 28 2 X 4 sq. mm + 1 X 4 sq. mm earth wire For 16A Power Circuit Point 29 4X10sq.mm+2X6sq.mmearthwireForDBSubmain wire 30 4X16sq.mm+2X6sq.mmearthwireForDBSubmain wire 31 Supplying and fixing two module stepped type electronic fanregulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 32 Supplying and fixing following Modular base & cover plate onexisting modular metal boxes etc. as required. 33 6 Module 34 8 Module 35 12 Module 36 Supplyingandfixingfollowingsize/ modules,Gl box along withmodularbase&coverplateformodularswitches in recess etc. as required 37 1 or 2 Module (75mm X 75mm) 38 3 Module (100 mmX75 mm) 39 SUB-HEAD-II: DISTRIBUTION BOARDS 40 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 41 8 way (4 + 24), Double door 42 12 way (4 + 36), Double door 43 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 44 Single pole 45 Supplying and fixing following rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 46 32A (DP) 47 40A (DP) 48 40A (TPN) 49 63A (TPN) 50 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 51 Supply, Installation, Testing and Commissioning of Surface Mount Round Led Downlighter consuming a system wattage of 18-22 W (±10%)& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing: Die Cast Aluminium. IP20 , Optics:PMMA/Polystyrene Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 10% & PF ≥ 0.95, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be easily available in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer along with Photo Biological Safety Standard (commercial Series). 52 Supply, Installation, Testing and Commissioning of 4ftLinear LED luminaire delivering an initial system lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm / W. The luminaire Housing shall be made of CRCA & the diffuser shall be of polycarbonate/PMMA. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 10% & PF ≥ 0.95 , 50,000 Hrs LED Life with L70 Criteria, IP20. The LED Driver shall be easily available in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacture along with Photo Biological Safety Standard.em lumens 1500.Similar to 15W WH RD or equivalent as per IS standard approved list of make. 53 Supply, Installation, Testing and Commissioning of 2ftLinear LED luminaire (Mirror light) delivering an initial system lumen of 903 lumens & the luminaire shall be with system efficacy ≥ 90 lm / W. The luminaire Housing shall be made of PC & the diffuser shall be of polycarbonate/PMMA. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 20% & PF ≥ 0.95 , 50,000 Hrs LED Life with L70 Criteria, IP20. The LED Driver shall be easily available in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacture along with Photo Biological Safety Standard. ( equivalent as per IS standard. (approved list of make) 54 Supply, Installation, Testing and Commissioning of 300mm dia sweep PVC body, 900±10% RPM Exhaust fan with guard and mounting arrangement. Commercial series

Key Value

Document Fees
INR 200 /-
Tender Value
INR 1.54 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail