Tender For Addn/Altn To Bldg No P-782At Chandimandir; 1 Taking down chowkhats or framen.exc 1.5 Sqm with shutter (without taking off shutters from the frame) and removal from site complete all as specified & directed. 2 Taking down chowkats or frame exc. 1.5 Sqm and n exc 4 Square metre with shutters, without taking off shutters from the frame,complete all as specified and directed. 3 Powder coated aluminum sections as inframes/ shutter of doors/window/ventilators /partitions,(Sliding / openable)including joinging cleats, glazing clips, rubber neoprene beading, powder coated aluminim snap beading, screws etc. complete all as specified and directedNote : (i) Minimum thickness of power coating shall not be less than 50 micron.(ii) Weight of aluminum section only shall be measuerd and paid.(iii) Aluminum doors/windows /ventilators to be fixed to jambs with chromium plated screws .(iv) The rate shall be inclusive of neoprene beadings, snap beading, screws etc and in case of sliding shutters locking arrangement and rollers in sliding shutters. Weight of fitting fixtures will not be measured for arriving the weight of aluminum section.(v) Glass /wooden panel/ACP sheet shall be measured and paid separately under respective items.(vi) Design as directed by Engineer in charge. 4 5.00mm thick selected quality tinted glass,fixed to aluminum frame work ,in panelsexc 0.5 Sqm in each pane, complete all as specified & directed. 5 Galvanised mild steel wire cloth 0.56 mm nominal dia of wire & avg width of aperture 1.18 mm in fixed with stainless steel wire staples, complete all as specified and directed. 6 4mm thick aluminium composite panel sheet (ACP) fixed with aluminium beading with rubber gasket including all necessary clips and fittings colour as approved byEngr-in-Charge all as specified and directed. 7 150mm long aluminium handles, cast type anodised type,complete all as specified and directed. 8 150 mm size aluminium, barrel tower bolt of extruded section complete all as specified and directed. 9 Aluminum alloy, anodized, sliding door bolt 250mm long hasp , staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed, complete all as specified and directed. 10 Floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, fixed in floor (140mm size),complete all as specified and directed. 11 4mm thick False ceiling fibre cement board, white in colour , 595mm x 595mm in size, fire and moisture resistance, fixed with and including standard GI snap grid framing (Powder coated) and suspended not exceeding 900mm below from ceiling with 3mm dia wire including clips and misc fittings etc in pattern as approved by GE, fixed as in repair (size of panel shall be of 605 x 605mm and GI snap grid framing shall be of 1mm thick standard section i.e. channels, angles, tee etc),complete all as specified and directed. 12 PVC lining coloured or selective pattern, PVC lining of hollow profile not less than 5mm thick and not less than 250mm wide intelocking type system as in wall/celing linings including end and intermediet U or L PVC sections as per manufacturer instructions, complete all as specified and directed(Note : Colour/design and pattern shall be as decided by the GE) 13 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish of the premisses, complete all as specified and directed. 14 Coloured vitrified ceramic tiles, light shade,8-9mm thick (square / rectangular) , area of each tiles n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. 15 Non skid ceramic coloured tiles7 to 8 mm thicksquare/rectangular) area of each tile exc 0.11 sqm but not exceeding 0.18 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 15 mm thick bedding layer in CM 1:6, complete all as specified and directed. 16 Glazed ceramic tiles, coloured in vertical surface 300mmx450mmx 7mm thick, joint free, first quality, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over 10mm thick rendering in cement mortar 1:4, complete all as specified and directed. 17 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub base finished fair and even without using extra cement, complete all as specified and directed. 18 Taking down existing plaster of any description on brick wall/ concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete, all as specified and directed. 19 15mm thick rendering on concrete / brick surfaces inclduing flashings and junction of parapets etc finished even and fair in cement mortar 1:6 using water proofing compound as per manufacturers instruction after brushing cement slurry complete all as specified and directed 20 Supply only integral water proofing compound complete all as specified & directed. 21 Applying Wall care putty (average thickness2mm as required for desired smoothness and leveling of surfaces in two or more layers) and sand papering for making the surfaces even and smooth complete all as specified and directed. 22 Preparation ofnew surfaces of any description of walls,facia, ceiling, RCCetc and applying two coats of oil bound distemper over one coat ofwall primer complete all as specified and directed. 23 Preparation of old decorated wall surfaces and applying one coat of oil bound distemper complete all as specified and directed. 24 Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid,bedded or laid bedded pointed in anymortar, all as specified. 25 Kota Stone Slab flooring, 20-25mm thick, best quality over and including cement screed bed 15mm thick in cement mortar 1:6, laid and jointed with grey cement slurry and pointed with grey cement mixed with pigment to match the shade of the slab including cutting, rubbing, grinding and polishing (Mirror finish) complete all as specified and directed. 26 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft and loose soil all as specified & directed by Engineer-in-Charge. 27 Excavation in trenches not exceeding 1.5m wide and not exceeding 3m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft and loose soil all as specified & directed by Engineer-in-Charge. 28 Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth , complete all as specified and directed. 29 Removal excavated soil to a distance exceeding 50 metrebut n.exc 250 metre and depositingwhere directed at a level not exceeding 1.5 metreabove the starting point complete all as specified & directed. 30 providing cement concrete type D2, 1:4:8 using 40 mm graded stone aggregate,as in foundations, filling and mass concrete etc., complete all as specified and as directed 31 Brick work with sub class ‘B’ bricks , straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified & directed. 32 Precast cement concrete type B-1, 1:2:4 using (20 mm graded crushed stone aggregate) as in man hole cover, drain cover, duct cover etcand setting in cement mortar 1:4 complete with joints to match includig the use of forms, moulds or machine moulds with plain faces nd provision of lifting where required rested over bricks or iron framescomplete all as specified and directed. (Precast cement concrete item shall be reinforced, where ordered. Reinforcement shall be measured and paid separately). 33 Mild steel hight stength deformedTMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bendingspirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified & directed. 34 Mild steel TMT bars6 to 8mm dia and over upto and including 10mm dia in stirrups, spacers and binding , cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified. 35 Vitreous China Urinal, half stall type, white,including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screwscomplete all as specified and directed. 36 Single piece EWC (one piece), minimum size 715 x 335 x 715mm, , snow white colour, S-trap with integraed flusing cistern, including slim soft close seat cover, fixed as in repair complete all as specified and directed. 37 Wash hand basin, vitreous china, flat back , white , ofsize580X400mm, angle brackets waste coupling, angle bracket 35mm x 35mmx 4mm (450mm long) and waste pipe, complete all as specified and directed. 38 Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect, complete all as specified and directed. 39 Angular stop cock, fancy type, cast copper alloy chromium plated, screwed down,screwed both and for iron pipe or for union, suitable for 15mm bore pipe, complete all as specified and directed. 40 15mm bore pillar tap, fancy type,cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, fancy type complete all as specified and directed. 41 Bib tap brass, fancy type, long body with wall flange, standard chromium plated, cast copper alloy, screwed down for iron pipe or for brass ferrule, suitable for 15mm bore pipe, fixed as in repairs complete all as specified and directed. 42 PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed. 43 15 mm bore Galvanized Steel tubes, medium grade including all fittings for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors , complete all as specified and directed. 44 Beveled edge looking mirror, 5.5mm thick of selected quality glass, including wood finish PVC mouldingmounted on 6mm thick ply or of PVC frame fixed to wall with screw and rawl plugs, complete all as specified and directed. 45 PVC(SWR) pipe, 110mm bore, single socketed in any length with rubber ring joints, having minimum density 6 Kg/cm2, laid in floors in trenches, complete all as specified and directed. 46 110mm bore PVC (SWR) bends any radius, complete all as specified and directed 47 Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in plain cement concrete 1:2:4 type B1 smooth finished,and reforming benching as required,internal dia of pipe 110mm all as specified and directed. 48 Providing and injecting chemical emulsion for post construction anti-treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed. 49 25mm dia stainless steelcurtain rod including fixing fancy types brackets, stops, rollers etc., as in repairs complete all as specified and directed. 50 Demolition of brick work built in cement mortar including all quoins, arches, pillar etc complete all as specified and directed. 51 Reinforced cement concrete,type A-1, 1:1½:3(nominal mix), using 20mm graded crushed stone aggregate) as in beams, lintels over 1.5 metre span and the like complete all as specified and directed (reinforcement shall be measured and paid for separately). 52 Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed. 53 Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. 54 Preparation of oldsurfaces of walls and applying two coats of cement base paint, complete all as specified and directed 55 Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate cast in situ in lintels up to 1.5 m clear span, cills, steps, seismic and other similar bands, hold fast, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straigth or curved) complete all as specified & directed by Engineer-in-charge. - NOTE : (i) The unit rate include for use of form work (straight or curved). (ii) Reinforcement if any shall be measured and paid separately. 56 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. 57 Material and labour forpoint wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account.Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. 58 All as per serial item 57 herein before but for socket outlet 3 pin 6Amps on same board complete all as specified and directed 59 All as per serial item 57 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed 60 All as per serial item 57 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area) cable as earth continuity conductor 61 Switch modular type (ISI marked), single pole, one way 6 Amps, one module(ISI marked), complete all as specified & directed. 62 Switch modular type (ISI marked), single pole, one way 16 Amps, one module(ISI marked), complete all as specified & directed. 63 Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed. 64 Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. 65 Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. 66 Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specifiedand directed by Engineer-in-charge. 67 Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed. 68 LED lamp9 watts, B-22 type complete all as specified . 69 Disconnecting the power supplyand taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCBs ,MCBs etcand removing from site, Complete all as specified and directed . 70 MCCB, 125 Amps, four pole, 3 phase , 16KA, 415 volt with adjustable thermal andmaganetic release, with proper thimble complete all as specified and directed 71 Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 125 Amps & outgoing 4 way having IP 43 protection Complete all as specified and directed . 72 MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting,12 way SPN with 200 Amps busbar 240V completed all as specified and directed. 73 MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V completed all as specified and directed. 74 MCB, SPN , 240 volt,32Amps, 10 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 75 MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 76 MCB, SP , 240 volt,40Amps, 10 KA , B series including connection with suitable size aluminium / copper lugs complete all as specified and directed 77 Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amp MCB complete all as speicified and directed. 78 LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable sizefixed as in repair complete all as specified and directed. 79 Slim LED lights fitting, 4 feet,1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed. 80 Slim LED lights fitting, 2 feet,1x 10W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed. 81 Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed. 82 Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 1.5 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 1.5 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughsteel conduit, cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. 83 Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. 84 Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.NOTE FOR SERIAL ITEM NO 82, 83 & 84(i)Two runs of cable, one run of earth wireshall be considered as one running metre(ii) Cutting chases will be measured and paid separtely(iii) colour code shall be Red for phase, Black for neutral and green for earth 85 Supply and fixing sub main wiring with Four singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.Note : (i)Four runs of cable, one run of earth wireshall be considered as one running metre(ii)Cutting chases will be measured and paid separtely(iii) colour code shall be Red for phase, Black for neutral and green for earth 86 Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth Complete all as specified and directed . 87 LED panel surface mounted2x2 - 36 watts , cool day, ceiling light, aluminum extruded housing with milky diffuser, heat exchanger unit, LED driver, surge protection complete suitable for perfect lighting cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fittingcomplee all as specified and directed. 88 Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) compelte all as specified and directed. 89 Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mmand provision of flexible copper cable 3 core from ceiling rose to exhaust fan complete all as specified and directed. 90 Detectors Complying with and type certified to EN - 45 Addressable type multisensor detector with heat and smoke combination Photoelectric /Optical with base with self built intelligence as per IS: 11360 fixed at location as per direction of Engineer-in-Charge complete all as specified and directed. 91 Fire Alarm 500 mtrs range sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DBfixed at location as per direction of Engineer-in-Charge complete all as specified and directed. 92 Fire alarm control panel complying with BS EN 54 single loop panel of capacity from 30 detectors & 30 modules supply, installation, testing & commissioning of addressable control panel 40 devices /2 Zone Microprocessor based Addressable Main fire alarm digital display panel input AC power supply, automatic battery charger, display panel input AC power supply, automatic battery charger 12 volts sealed maintenance free lead acid batteries sufficient for 08 hours normal working and capable of operating the system for 60 minutes during emergency conditions complete with log facility complete all as specified and directed. 93 Manual call point for fire alarm system including all commissioning and testing as per direction of Engineer-in-Charge complete all as specified and directed. 94 Supply Installation, commissioning & testing LT Panel indoor type made out of 3.15mm thick steel and angel iron supports complete factor made plinth mounted, cubical type, dust and vermin proof, front back and sides openable duly provided with bus bar chamber, cables entry chamber, cabinets of suitable size for housing MCCBs metering cabinet for fixing voltmeter, ammeter and indicators lamp and painted with two coats of synthetic enamel paint (Powder coated )over one coat of red oxide primer and using copper bus bar of 250 Amps rating for phase and half of the rating of neutral duly fixed with suitable insulators and nuts and bolts comprising of the following incoming and outgoing feeder control complete all as specified and directed.(A) INCOMING :-(a)MCCB 250 Amps, 4 Pole, 36 KA -01 Nos(b)Voltmeter digital type 0 to 500 volts with selector switch – 01 No(c) Ampere Meter digital type 0 to 100 front operated Amp with selector switch – 01 No(d)Change over switch off load type 4 pole, 250 Amp – 01 No(B)OUTGOING(a)MCCB 200 Amps 4 pole 35 KA- 01 No(b)MCCB TPN, 25 KA, 160 Amp -01 No(c)MCB SPN 40 amp – 01 No 95 Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mmburried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe of20mm dia, GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. 96 Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mmburried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including galvanised iron strip 32 x 6mm as earthing leadby means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe of20mm dia, GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. 97 LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,includinglamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, including taking down old street lght complete all as specified and directed. 98 Supplying, installing and commissioning of split type air conditionerwith coolingfunction EER 3.2 of capacity 1.5TR, 05 star rated with cordless remote control unit and in built air ioniser, plasma filter for better indoor air quality, suitable for wall mounted, single phase, 230/250 volt AC including breaking necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing finishes after commissioning,PVC pipe medium duty 25 mm dia for draining out condensed water,all as required including necessary electric connections, complete all as specified and directed. 99 Supplying, installing and commissioning of split type air conditionerwith coolingfunction EER 3.2 of capacity 2TR, 05 star rated with cordless remote control unit and in built air ioniser, plasma filter for better indoor air quality, suitable for wall mounted, single phase, 230/250 volt AC including breaking necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing finishes after commissioning,PVC pipe medium duty 25 mm dia for draining out condensed water,all as required including necessary electric connections, complete all as specified and directed.NOTE FOR SERIAL ITEM NO 105 & 106 (i) Quoted rates shall deem to include the cost ofdrain pipe, copper tubing of requisite length and 4 sqmm multi standard copper cable, brackets, etc.(ii)Installation and commissioning to be done through OEM / itsauthorised service centre / agency. 100 Supply and installed voltage stabilizer automatic digital display type, single phase naturally air cooled indoor type & designed for input variation between 170V to 250 Volt with output voltage stabilized at 230 Volt +/- 2.5% of capacity 5.0 KVA complete all as specified and directed. 101 Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 flat , size 300mm x 180mm x 40mm complete all as specified and directed. 102 Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 flat , size 250mm x 150mm x 40mm complete all as specified and directed. 103 Dry sand cushioning to underground cables with 8cm thick layer before laying of cables and 15cm thick after laying and stretching of cable complete all as specified and directed. 104 XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm, 3.5 core, laid in trenches , sleeving through pipes of fixed on poles & wall or laid under floors inlcuding jointing with suitable size of alumunium lugs as specified and directed. 105 XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sqmm, 3 core laid in trenches , sleeving through pipes of fixed on poles & wall or laid under floors inlcuding jointing with suitable size of alumunium lugs as specified and directed. 106 Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed 107 Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed 108 Shifting of 63/100 KVA transformer from MES yard to building No P-782 (Map Depot) proposed Four pole structure using hydrA / crane etc of suitable size, including necessary connections / disconnections complete all as specified and directed. 109 Steel tubular swaged poles complete with cmild steel base plate, closed at top as specified, type 410 SP-55 (11 metre long) including painting with two coats of black bituminous paint externally up to th planted depth internally through out and remaining external portion with two coats of aluminium paint, over a coat of red oxide primer complete all as specified and directed.NOTE : Excavation & earth work, foundation concrete will be measured and paid seperately under respective item(s). 110 Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed. 111 Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, of red oxideone under coat and one finishing coat of aluminium paint complete all as specified and directed 112 Pin type, porcelain, vitreous, white/browninsulator including one galvanised mild steel spindle, two galvanised iron washers of size 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed 113 Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 25x20cm size complete all as specified and directed 114 Jumpers in red/ yellow/blue colour for HT lines / connections made from aluminium conductor single core PVC insulated cable of suitable size complete including winding wires, aluminum tape etc complete all as specified and directed 115 Supply Installation, commissioning & testing LT Panel outdoor type double door suitable for floor mounting, with locking arrangement fabricated out of 3.15mm thick CRCA sheet ISMC 75 for base frame powder coated,dust/water and vermin proof suitable for 415 volts3 phase 50 Hz, complete with and including following accessories :-(a)MCCB 250 Amps, 4 Pole, 36 KA 415 volt, adjustable thermal and fixed magnetic (incoming)(b)Aluminium strip bus bars sleeve insulated and mounted on epoxy insulators, 400 Amp Capacity, TPN-01 set(c) Three pole MCCB 100 Amps 25 KA 415 volts with adjustable thermal and fixed magnetic release and Ics=100% of Icu-03 Nos(d)LED type indicators RYB-01 set(e)LT CTS 250/5 Amps -03 Nos(f)Multifunctional meter 96mm x 96mm, flush mounting, digital type-01 No(g)Earthing terminals-02 Nos(h)Danger notice plate dully riveted/fixed on front door- 01 No(j)internal wiring of the panel board circuits with copper conductor PVC insulated single core cable of suitable dia including control MCB SP in each circuit 116 Lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 KA 11000volts complete all as specified and directed. 117 Gang operated air break switches with vertical islation complete with drop out fuse unit triple pole, 12 insulator type, manually operated, mounted on insulators and steel frame, with operating mechanism worked from ground level for rating 200 Amps, 11000 volts complete with GE operating pipe of heavy duty grade of suitable length compelte all as specified and directed 118 Cuttingof road/ hardstanding for passing cables in pipes and making the surface good by doing necessary PCC work complete all as specified and directed. 119 GI tube 100mm bore light grade for cable protection on poles/walls/under road/culvert etc complete all as specified and directed. 120 Supply, install, testing and commissioning of diesel Engine driven generating set of min 82.5 KVAcapacity 3 phase, 4 wire, 415 V, 1500 RPM conforming to relevant IS Codes, AC power supply with power factor 0.8 coupled directly to alternator mounted on a common MS base frame with sturdy design complete with AMF panel, integral acoustic enclosure-sound proof canopy (should have silent features as per CPCB -IV+ norms), fuel tank with draw-out/drag-out facility for easy cleaning, SMPS power supply unit of relevant Amperage and Voltage for Battery Charging in case of non-operation for long periods,long life in all weather conditions & for outdoor application/installation, incl battery & standard accessories, and 5 Years Comprehensive Annual Maintenance Package by OEM/Manufacturer including consumables and unlimited visits by service engineer all as specified and as directed with following specification :-(A) ENGINE :Liquid Cooled, electric start, 4 Stroke, min 4 cylinders cold starting, TCI aspirated, compression ignition, totally enclosed diesel engine conformimg to present CPCB IV+ norms at 1500 RPM developing suitable BHP capacity to match not less than 82.5 KVA alternator under NTP conditions as per ISO 8528 Part-I with provision of 10% over load for 1 hour in every 12 hours running confirming to IS: 10000/ISO 3046/ BS: 649/ BS: 554 amended up to date, the Engine shall consist of the following :- (i) Dynamically balanced fly wheel or as per manufacturers standard. (ii) Coolant cooling system complete. (iii) Air cleaner as per manufacturers standard. (iv) Fuel injectors and fuel pump as per manufacturers standard. (v) Electronic/ mechanical governor as per manufacturers standard to maintain engine speed at all conditions of load. (vi) Fuel service tank of minimum 185 Ltr capacity fabricated from MS sheet with draw-out/drag-out facility, inlet outlet connections air vent tap, level indiactor, MS fuel piping from tank to engine with valves, unions, reducers, flexible hose connections, mounting pedestals, fuel filters incl all as per manufacturers design.(vii) Dry exhaust manifold with suitable exhaust residential grade silencer to reduce noise level as per CPCB -IV+ norms(viii) Battery charging alternator unit along-with SMPS PSUand voltage regulator, suitable for starting. 121 (ix) Gear driven oil pump for lubricating oil, priming of engine bearing, as well as fuel systems as per manufacturers recommendation. (x) Natually aspirated/turbo charger as per manufacturers standard.(xi) Lubricaton oil coolers and filters with replaceableelements as per manufacturers standard (xii) Crank case heater with manufacturers recommendation. (xiii) All moving parts of the engine shall be mechanically guarded in such a manner that a human finger cannot touch any moving part (xiv) Radiator as per manufacturers standard. (xv) Engine control panel having digital display complete with :- (aa) Start/stop key switch (ab) Lubricating oil pressure indication (ac) Lubricating oil temperature indication (ad) Water temperature indication (ae) RPM indication (af) Engine hours indication (ag) Battery charging indication (ah) Low lub oil trip indication (aj) High water temp indication (ak) Over speed indication (xvi) Any other item not included/specified but is a standard design of the manufacturer.(B) ALTERNATOR (i) Alternator of capacity 82.5 KVA at 1500 RPM, 0.8 lagging power factor, 3Ph, 415 V, 50 Hz, H Class insulated winding, IP-23 protection, Close-direct-coupled, self-excited and self-regulated type, screen protected, mounted on rigid MS sheet channel base frame,alternator shall be confirming to IS: 13364, IS: 4722, BS-5000, IEC: 34 and suitable for tropical condition. 122 (ii) Type : Self exited self regulated with automatic voltage regulator (electronic type) (iii) Rating : 62.5 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition. (iv) Speed : 1500 RPM (v) System : 415 Volt +/- 5 % AC 3 phase 4 wire 50 Hz. (vi) Connection : 4 wire star connected. (vii) Enclosure : Screen protected drip proof. (viii) Ventilation : Self ventilated (ix) Anti friction bearings (x) AVR output voltage within +/- 1%(C) CONTROL PANELThe control panel is to be inside canopy and fabricated out of 1.6mm thick CRCA sheet cubicle type totally enclosed, powder coated, IP-53 protection, equipped with MCCB of suitable capacity, voltage metering & safety, frequency meter metering & safety, ampere metering & safety, fuel level gauge in % metering , Lub oil pressure metering, high water temp metering, engine RPM metering, Power metering, Power factor metering, set of suitable CTs, toggle switch, idicating LED lamps , incoming and outgoing terminals all as specified by manufacturer and directed by Engr-in-Charge.(D) ONE SET OF ACCESSORIES COMPRISING OF :-(a) Base frame of sturdy design and necessary reinforcement with built-in diesel tank as per manufacturers standard. (i) Fuel tank of sheet metal complete with drain valve, air vent, inlet, outlet connections, and mechanical gauge. (ii) One No battery 12V charged with connecting leads of suitable capacity as per manufacturers standard. (iii) Fuel tank should be of draw-out/drag-out facilityfor easy cleanout.(iv) SMPS PSU for battery charging in case of non-running of DG set for long periods. (v) 5 Years Comprehensive Annual Maintenance Package by OEM/Manufacturer including consumables and unlimited visits by service engineer.(vi) PCC work (1:2:4, M-20 grade) of suitable dimension for foundation of DG setas recommended by the Genset Manufacturer/OEM/OEA shall be deemed to be included in the quoted rate.