Tender For Special Repair To Main Gate, Duty Jco Room And Guard Posts Of 509 Abw Under Ge (East) Agra; 1 Dismantling of Plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings etc complete all as specified and directed. 2 S&F of Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. 3 S&F of Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. 4 S&F Pre-painted, galvanized, pre-fabricated PPGI sheeting 1.00 mm thick in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 including all fixing arrangement etc. complete all as specified and directed 5 M&L for Cutting grooves in brick wall, 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 etc complete all as specified and directed. 6 Dismantling timber scantlings 40 sq. cm and over in section, in any position etc complete all as specified and directed. 7 M&L for2nd class hardwood in scantling clean sawn and framed for roof truss etc completeall as specified and directed. 8 M&L for Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coat of Creosote oil all as specified and directed. 9 S&F of Rooftrusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, wind tie,channel,pipe or flat sections) including distance pieces, welding, cutting , cleats and connecting boltsetc Fe 410 -W (GdeE- 250) qualityA complete all as specified and directed. 10 M&L for preparation of new steel surfaces of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zincchrome primer complete all as specified and directed. 11 Dismantling wall and ceiling board or insulation board /slabs/blanket any thickness including cover fillets etc complete all as specified & directed. 12 S&F in repair 605x605mm snap grid of powder coated galvanized iron of angle of size 23mm x 23mm of 30 gauge (Perimeter), T section of size 23mm x35mm main and 23mm x 27 mm (intermediate) of 30 gaugesuitable for false ceiling including GI wire 4 mm thick @ 1200 mm centre to centre both ways for hanging arragement coplete all as specified and directed. 13 M&L for 4 mm thick non asbestos fibre cement building board designer as in ceiling of size 600 x 600mm fixed to GI snap grid frame workcomplete all as specified & directed. 14 M&L for refixing of 4 mm thick non asbestos fibre cement building board designer as in ceiling of size 600 x 600mm fixed to GI snap grid frame workcomplete all as specified & directed. 15 Taking down chowkats or frame with shutter (without taking off shutters from the frame) not exc 1.5 Sqm each complete all as specified and directed. 16 All as per item No 15 before but exc 1.5 Sqm and not exc 4.00 Sqm each complete all as specified and directed. 17 S&F Powder coated / anodized aluminium door & frame 0.55 Kg/m incl- 5.00mm thick tinted glass in half portion andin other half portion 6 mm thick ACP sheet of approved colour complete and fixed withaluminium snap beading, glazing clips, joining clips, screws and 02 Nos of aluminium handle on each door shutter, aluminium anodized tower bolt 200 mm long 02 Nos on each shutter and mortice lock device complete with double keys for each lock, 01 No hydraulic door closure for each shutter complete all as specified and directed with following specifications:- (a) Aluminium door frame = 101.50x44.45mm(b)Aluminium style/top & middle rails of shutter = 83.5x44.45mm(c) Aluminium bottom rail of shutter = 114.50x44.45mm(d) Aluminium door frame with shutters shall be fixed in position in brick wall opening as required according to site conditions including all fastening arrangements & making good of existing surface with obd/whitewash over plaster after fixing door etc complete all as specified and directed 18 S & F powder coatedaluminium window and ventilator shutters including frame,aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws,plain glass on shutters ,anodised aluminium fittings such as peg stays 150 mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) & and aluminium deco grill fixed to outerside of aluminiumframe in suitable type of aluminium beading complete all as specifiedand directed by Engr-in-Charge. 19 Providing & fixing ofwindowsmade of pre-painted steel (Base steel as per IS 513 of 0.58mm thick “D” Quality galvanized as per IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72x55mm, centre mullion should be of 72x50mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 52 x 25mm. Outer frame & mullion sections to have rebate for glazed shutters, fly mesh and 20 mm provision for guard bars/ grills fly mesh shutter section should be of 20x40mm. The sections are to be cut to length mitre joined with corner bracket. Centre mullions to be fixed with mullion cap. Elixir or equivalent stay, handles 2nos of heavy-duty stain less steel pivot hinges shall be provided per shutter. The windows should be panelled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade). Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self-expanding, screws. Including 10mm square guard bars with 6” (152.4mm) pitchincluding making good of existing surface with obd/whitewash over plaster after fixing window etc complete for finished item of work including of all taxes etc as specified and directed. 20 S&F tubular steel framed work as in chowkhat / frame for single door frame of size 100 x 50 mm & thickness of tubular sectionll be 2.5 mm for doors with one or more rebates including necessary fixing lugs, lock, strike plate,hold fast etc completecomplete all as specified and directed.(Wt. of section should be exc 4.5 Kg/Rm) 21 S&F tubular steel framed work as in chowkhat / frame for double door frame of size 130 x 65 mm & thickness of tubular sectionll be 2.5 mmfor doors with one or more rebates including necessary fixing lugs, lock, strike plate,hold fast etc complete all as specified and directed. (Wt. of section should be exc 6 Kg /Rm) 22 S&F forMild steel framed work as in chowkhat / frame of doors or gates of angle or other section with gusset plates, rails, braces,hold fast etc., complete all as specified and directed., drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete, quality conforming grade Fe- 290 or E- 165 complete all as specified and directed. 23 S&F Factory made flush shutter 30 mm thick solid core construction with block board core and plywood face panels commercial type complete all as specified & directed. 24 S&F for 1.6 mm thick mild steel black sheet as in steel gate and similar works cut to size, holes punched including round headed screw welded etc complete as specified and as directed. 25 S & F 30 mm thick, factory made , llnd class hard wood (Sal) glazed and skeleton shutter open rebated and prepared to receive glass, gauze, etc. (with out sash bars), edges of framing plain, charmfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part l, section 8 clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed. 26 S & FStainless steel wire cloth. 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc complete all as specified and directed 27 S&F Aluminium alloy, anodised, 250 mm sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. 28 S&F 200 mm long aluminium anodized barrel tower bolt of extruded section complete all as specified & directed. 29 S&F Mild steel butt hinge medium weight cold rolled of size 100 mm long and fixed with screw/ welding complete all as specified and directed. 30 S&F 150 mm long aluminium anodized handle cast type complete all as specified and directed. 31 S&F of factory made soild PVC door frame of size 50mmx47mm made out of 5mm thick single side prelam PVC sheet reinforced with mild steel square tube , supplying & fixing in opening as per specification and drawing complete all as specified & directed.. 32 S & F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2 mm thick Moulded PVC Sheet on the front face & 2 mm plain colour PVC sheet on back face with particle board core, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. 33 S&F 150 mm long aluminium anodized barrel tower bolt of extruded section complete all as specified & directed. 34 S&F 100 mm long stainless steel hinges type B-12 and fixed with screw/ welding complete all as specified and directed. 35 M&L 100 mm long aluminium anodized handle cast type complete all as specified and directed. 36 M&L for one coats of synthetic enamel paint (Ordinary tint)including preparation of old surfaces of steel of any description not otherwise described over 10cm in width or girth complete all as specified and directed. 37 M&L for Two coats of synthetic enamel paint (Ordinary tint) over a coat of pink primer including preparation of new or previously untreated surfaces of wood of any description not otherwise described over 10cm in width or girth complete all as specified. 38 S&F in repair aluminium powder coated partition of specified aluminium section as per required size & Wt. of section can not be less than 0.55 Kg / Rm including aluminium beads, rubber gasket and 5 mm thick Plain glass in upper portion and 6 mm thick ACP sheet of approved colour etc complete all as specified and directed. 39 Taking down cement or cement lime plaster of any discription on bricks or stone walls/ceiling etc including racking out joints, hacking for kay, scrubbing down with water. 40 M & L for washed stone grit plaster on exterior walls in two layers , under layer 12 mm thick cement plaster 1:4 ( 1 cemant : 4 coarse sand ) furrowing the under layer with scratching tool , applying cement slurry on the under layer @3 Kg of cement per sqm , top layer 15 mm th cement plaster1 :1 / 2 :2 ( 1 cement : 1/2 coarse sand : 2 stone chipping 10 mm nominal size ) in panels with groove all arround as per approved pattern incl. scrubbing and washing the top layer with brushes and water to expose the stone shipping complete all as specified etc 41 Forming groove of uniform size 15 mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens nailed to the under layer incl. removal of wooden battens , repair to the edges of panels and finishing the groove complete all as specified & directed. 42 M&L for 10 to 12 mm thick smart careready mixplaster with high quality polymer additives and well graded sand and fillerswhich can be used for plastering (as per manufacturer instructions) over exteriorsurface of walletccomplete all as specified & directed. (Note : Coverage for smart care ready mix plasterll be 24 - 28 kg / sqm) 43 Material & Labour for preparation of new plastered surface and applying one coat of silane siloxane primer @ 0.12 kg / sqm over two coat of apex ultima paint (silicon additive ) @ 10 sqm / litre in each coat over priming coat of exterior primer applied @ 0.90 litre/ 10 sqm etc complete all as specified and directed. 44 M&L for 10 to 12 mm thick smart careready mix repair plaster with high quality polymer additives and well graded sand and fillerswhich can be used for plastering (as per manufacturer instructions) over interior surface of walletccomplete all as specified & directed. (Note : Coverage for smart care ready mix plasterll be 24 - 28 kg / sqm) 45 M&L for two coats ofdistemper oil emulsion over a coat of average 2 mm thick wall care puttyon new plastered surfaces complete all as specified and directed. 46 M & L for applying bonding agent for bonding old to new concrete surface likes chajja/ beams/ celings/ columns/ faciaetcby high performance modified Styrene- Butadiene Rubber ( SBR ) base binder . Applying ofbinder isas 10 sqm/ per litetccomplete all as specified & directed. 47 M&L for single component polymer modifiedrepair mortar upto 30 mm thickness in double coatfor repair of RCC members likes beams, columns, chajja and facia/Ceiling, mortar having good compressive strength and shrinkage resistance etccomplete all as specified & directed. 48 Material & labour for preparation of new plastered surfaces of ceiling and applying three coats of white wash to match the existing as required, complete all as specified & directed. 49 M&L for brick work with subclass B bricks old size straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 including dismantling of brick work complete all as specified and directed. 50 M&L for preparing old plastered or unplastered surfaces of walls by brooming down or by steel wire brushing scraping down smoke soot, moulds moss and efflorescent salts and applying two coats of distemper oil emulsion over 2 mm thick wall care putty complete all as specified and directed. 51 Material & Labour for preparation of old plastered surface including removal of existing treatment and applying one coat of silane siloxane primer @ 0.12 kg / sqm over one coat of apex ultima paint (silicon additive ) @ 10 sqm / litreover priming coat of exterior primer applied @ 0.90 litre/ 10 sqm etc complete all as specified and directed. 52 M&L for 2 mm thick wall care putty on wall surface etc complete all as specified & directed. 53 Material and Labour for preparation of old plastered surfaces of ceiling etc by brooming down by steel wire brushing, scrapping down smoke Soot, moulds, moss and trading oil and greasy spots etc and apply two coatof white wash complete as specified and directed. 54 Dismantling stone slabs and tiles of any description or thickness in floors / dados, etc laid bedded and pointed in any mortar complete all as specified and directed by the Engineer-in-charge 55 M&L forVirifiedtiles of any shade 8 to 10 mm thick (square/ rectangular) polished, area of each tiles n exc 0.36 sqminfloors etc white cement and coloured pigment to match the tiles over 15 mm thick screed bed in CM 1:6complete all as specified and directed. 56 All as per item no. 55 but in skirting over 10 mm thick rendering in CM 1:4 etc complete all as specified and directed. 57 Demolition of concrete in any description and in any position (unreinforced) complete all as specified and directed. 58 Material and labour plain cementconcrete type B-0, 1:2:4 (12.50mm graded aggregate) 25mm thick as in sub floor, sub base, to receivetiles omplete all as specified and directed. 59 M&L for non skid ceramic coloured tiles (Premium quality) (squre/ rectangular) area of each tiles exc 0.11 sqm but n. exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles over 15 mm thick screed bed in CM 1:6 etc complete all as specified and directed. 60 M&L for glazed ceramic coloured tiles of size450x300x7mm thick fixed on vertical surfaces such as skirting, dados and risers to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick rendering in CM 1:4 including two coats of fosroc brushbond aqua protect or equivalent which is applied on wall surface before rendering etccomplete all as specified and directed. 61 M&L for 75 mm thick Cement concrete type D-2 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing finishing surface even and rough using broomfinish complete all as specified and directed. 62 M&L for 80 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath,parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50 mm thick compacted bed of coarse sand,compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified & directed. 63 M & L for18-20 mm thick black granite oflength and width as required including fixing, necessary cutting including 10 mm thick CM 1:4 Plaster etc complete all as specified & directed. 64 Taking up or down 15 mm bore steel tubing including fittings and connections, including cleaning for Refixing or removal to store complete all as specified and directed. 65 S&F 15 mm bore Galvanized Steel tubes, medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. 66 Taking up or down 20 mm bore steel tubing/ PPR pipe including fitting and connections, including cleaning for Refixing or removal to store complete all as specified and directed. 67 S&F 20 mm bore Galvanized Steel tubes, medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. 68 S&F 500 litres capacity Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PVC float valve complete all as specified in SSR Part I including dismantling of storage tank. 69 S&F20 mm diaGun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified & directed. 70 S&F in repairs 5 mm thick bevelled edge mirror of selected quality glass of required size and shape with 50x20 mm teak woodpolished beading mounted on 6 mm thick commercial ply wood / ACP / PVCand fixed to wooden plugs with chromium plated brass screw and cup washers complete all as specified and directed. 71 S&F in repairs Vitreous China wash hand basin counter type white of size 550x440 mm including32 mm CP waste coupling and rigid pvcwaste pipe 800 mm long fixed overblack granite etc complete all as specified and directed. 72 S&FPillar taps long bodycast copper alloy fancy typewith capstan heads chromium plated scrwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for 15 mm dia iron pipe complete all as specified and directed. 73 S&F in repairs 10 litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets & taking out of old unserviceable connections etc, connecting up new and making good disturbe portion complete all as specified and directed. 74 S & F in repairsPVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed by the Engineer-in-charge. 75 S&F in repairs 15 mm bore CP stop cock/angle cock, cast copper alloy fancy type, screwed down high pressure, screwed for iron pipe or for unions and fixed complete all as specified and directed by the Engineer-in-charge. 76 Supply & fixing in repair CP tubular towel rail, 60 cm long, 20mm bore, chromium plated complete all as specified & directed. 77 S & F in repair CI floor trap, plain including jointing with solvent cement (Diameter of outlet 75mm), jointing to waste pipe and fixed in cement concrete 1:2: 4 (type B1) mixed with water proofing liquid @ 200ml in 50 kg cement, inlcuding taking out of old unserviceable connections etc, connecting up new and making good disturbe portion complete all as specified and directed. 78 S&F in repair vitreous china wash down water closed pan (Pedestal pattern) with CI P or S trap including connection to trap and cistern and flush pipe (excl flusingh cistern ) and making good to disturbed surface of floor allfixed as in repairall as specified and directed. 79 S & F in repair of plastic WC seat cover and mild steel chromium plated or aluminised hinging device asetc complete all as specified and directed. 80 S & F in repairs Flushing Health Faucet for pedestal pattern WC incl .flexible pipe and brass chromium plated nuts and bolts and water pipe of size 1150 mm long between dia & fixed completed all as specified and directed. 81 S & FFlushing jet for pedestal pattern WC incl. flexible pipe and Brass Chromium Plated nuts and blotsandwater pipe of size 1150 mm long between dia & fixed complete all as specified and directed. 82 S&F in repairbib taps long bodycast copper alloy, fancy type, chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule orto GI socket or PPR pipe etc making good disturbed portion complete all as specified and directed. 83 Supply & fixing in repairs C.P. grating 100/125 mm dia with or without centre hole etc all as reqd at site complete all as directed. 84 S&F in repairs CP Soap dish 100 mm dia fixed with cp screws etc complete all as specified and directed by the Engineer-in-charge. 85 S&F in repairs Vitreous China Urinal, full stall type complete including providing and fixing plugs bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60 mmlong brass screws pointing arounds urinal back in cement , fixing of nozzles for discharge of water flushing pipe andgrating and union for discharge pipes etc complete all as specified & directed. 86 Taking down Rain water pipe of any size or pattern ( CI / pvc / AC pipe ) including all fittings etc complete all as specified & directed. 87 S&F100 mm bore cast iron soil, waste vent sand cast pipes in any length with or without ears, with cement joints fixed to walls including making good disturbe portion to match the existing complete all as specified and directed by the Engineer-in-charge. 88 S&F 100 mm bore cast iron soil, waste vent sand cast pipes in any length with or without ears, with cement joints laid in floor or in trenches including making good disturbe portion to match the existing complete all as specified and directed. 89 S&F 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access doors and cement joint including making good disturbe portion to match the existing complete all as specified and directed. 90 S&F 100 mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors and cement joint including making good disturbe portion to match the existing complete all as specified and directed by the Engineer-in-charge. 91 S&Fclamps out of 50 mm by 5 mm flat iron fixed with suitable bolt / screws securing ends of stays to wall or roof for PVC (SWR) / CI Pipe for 100 mm bore pipe complete all as specified & directed. 92 S&F PVC (SWR) pipes single socketed 150 mm bore Pipe incl bend,shose, Tee, Y as required, etc in any length with rubber ring joints fixed to walls with MS clamp all as specified and directed. 93 S & F in110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall/floorincluding clamp complete all as specified and directed. 94 S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed. 95 S&F 110 mm PVC (SWR) junction single,(Single T) equal or unequal complete all as specified & directed. 96 M&L 75 mm thick PCC (1:3:6) type C1 using 40 mm graded stone agg as in plinth protection / Path / pavingsurface even and smoothand and exposed edges fair or rounding or chamfering laid in panels with and including all necessary form work and filling the joints with mastic filling of one part of hot bitumen 85/25 grade and three part of fine sand (all by weight) complete all as specified and directed. 97 M&L for PCC 1:2:4 Type B1 ( using 20 mm graded stone aggregate), in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in eight, copings, kneelers, apex stones bed plates, kerbs chajjas , water troughs, bed blocks and the like including weathering, slightly rounded or chamfered angles and throating, fixing of chain link fencing etc all as directed incl necessary formwork etc complete all as specified and directed. 98 Dismantling of wooden wall panelling incl. frame and making good the surface etc all as specified and directed. 99 S&F solid PVC Wall Lining for wall panellingconsisting of 5 mm thick wood grainprintedcolour PVC sheet inclusivefixing with all accessoriesat site as per specifications and drawing complete all as specified and directed. 100 M&L for 5 mm thick PVC sheet fillet of width 35 mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specified & directed. 101 M&L for ATT points of contact of wood work by chemical emulsion (Imidacloprid 30.5% SC odorless chemical) in oil or kerosene based solution @ 0.5 litre/hole by drilling 6 mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same and making good as existing surfaces complete all as specified and directed. 102 M&L for treatment of voids in masonry using chemical (Imidacloprid 30.5% SC odorless chemical) emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors andetc complete all as specified and directed. (No extra payment shall be claimed on this account) 103 Taking down of all loose and de-bonded concrete/ screed, loose particles, dirt etc & Debris should be removed from Bldg. Roof substrate must be pressure-washed with watertoremove all dirt, dust, chalking and waste products. Remove algae, mold by using bleach solution or biowash etc complete all as specified & directed. 104 M&L for repair of all visible hairline cracks on concrete roof / screed more than 0.50 mm and not giving hollow sound, should be cut and widen in V shape with mechanical cutter in the size (10mm W x 6mm D). Fill cracks withPU sealant / Hybrid Sealant with suitable gun and smoothed with a putty knife or trowel. Allow sealant to cure a minimum (72 Hrs.) 3 days etc complete all as specified & director. 105 M&L forClean the concrete screed with high pressure water jet to remove dirt and loose particles. Brush apply a bond coat ofPidicrete URP mix in the ratio of 1:1 (URP 1: Cement 1) by volume to make it lump free slurry when applied on in the pre wet surface. Laid to fall roof screed in correct slope and gradient. Mix Pidicrete URP 10 % by weight of cement in concrete in ratio of 1(cement) :1.5 (sand) :3(12.5 mm aggregate) & avg thickness of concrete should be 25 mm.Level the repair concrete and finish with trowel. Moist cure should be done for 7days. Air cure screed for 7days, before application of roof top coat coating system etc complete all as specified & directed. 106 M&L for Apply one coat ofCipoxy 16D primer in the ratio 1:1 spreading at the rate of 0.200 kg-0.250 kg /sqm in complete dry condition where moisture contain below 7% (should be checked with moisture meter)Allow the primer coat to dry for 6 to 8 hours. Apply 1st coat ofRoofseal Classic without dilution spreading at the rate of 0.70/litre/Sq.mt/Coat until all surface is covered. Lay a 45 GSM Fibre glass mesh as a reinforcing material which is incorporated in the coating when the first coat is still in wet condition. Allow the first coat to dry for approximately 4 to 6 hours. Apply the second of chemical with the same application coverage, but in a direction perpendicular to that of the first and second coats. Allow each coat to air cure for a minimum of 4-6 hours after application. Check to see no void surface is left untreated / uncoated.Allow the system to air cure for 7 days minimum etc complete all as specified & directed. 107 Dismantling of structural steel work incl. doors , gates etc complete all as specified & directed. 108 S&F ornamental Framed and hung as in doors or gates of angle or other section with gusset plates, rails, braces incl. pintle hinges , stops hand made sliding boltsetc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging; also fastening and fixing complete all as specified and directed. Note:-Weight of gate decided by BOO which will be conveyed by GE before fixing and necessary arrangements for weighing of steel gate by the contractor on his own expense. 109 S & f in repair 25 mmpre cast decorative designerRCC jallies fixed in 100mm x100mm decorative designer post consists with precast concretetype B 0 1:2:4 ( 12.5 mm graded stone aggt ) set in cement mortar 1:4 etc including two coat of weather proof paint etccomplete all as specified & directed. 110 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, fan regulators, sockets, lamp holders, bell push, call bell, LED bulbs, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete and all as specified. 111 M&L point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts.grade FRLS PVC insulated unsheathed cable with proper colour codingdrawn in includingPVC conduit medium grade not less than 20 mm dia with all accessoriesandFRLS PVC insulated 1.5 Sqmm multi standard unsheathed copper wire for continues earth, sunk in cast iron/Pressed steel terminal boxes 60 mm deep & 1.6 mm thick duly painted with aluminum inside and anticorrosive paint out side, including 3 mm thick plastic laminatedsheet for mounting switches, sockets, fan regulators etcconnecting earthand making good to the disturbed surfaceof wall/floor and matching with existing specifications.Connections of cable with MCBs or bus bar shall be done through proper size copper/brassthimbles.Note :Conduit shall be fixed on surface of roof /Trece with necessary saddles where concealing of conduitis not feasible at no extra cost for the following :-(a) One light /fan point controlled by one switch 112 (b)One 5 pin socket outlet5 Amps on same board 113 (c) One 5 pin socket outlet 5 Amps on independent board 114 All as per item No 111 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLS PVC insulated sheathed cable with FRLS PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent boardcomplete all as specified and directed. 115 Supply and fix switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body complete all as specified and directed. 116 Supply and fix Switch piano flush button single pole one way 15 amps 230 Voltswith polycarbonate body complete all as specified and directed. 117 Supply and fixsocket 5 amps 5 pin flush type, 240 volts. with polycarbonate body. Complete all as specified and directed. 118 Supply and fixsocket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts with polycarbonate body complete all as specified and directed. 119 Supply and fixstepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd,complete all as specified and directed. 120 Supply and fixceiling rose , PVC/polycarbonate, insulated body surface Bakelite 65mm dia three terminals complete all as specified and directed. 121 Supply and fixing in repair ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) . 122 Supply and fix in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m incl taking down the old unsv. 123 Supply and fixing in repair LED luminaire in replacement 595 mm x 595 mm, 40 watt, 220 V AC, 6500 K recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver and connecting the same to electric source with & using PVC sheathed and insulated three core copper conductor cable of size 0.75 Sqmm and fixing arrangements for fixing the light fitting completeall as specified and directed. 124 Supply and fixing in repairLED light fittingwith high out put diffuser 4 feet, 20 watt 220 V AC, LUMEN < 2000 with lumen efficacy 120 lumen/watt, basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 125 Supply and fixing in repair LED building security light fitting 35 Watt 230 V AC out-door type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection,fixed to pole or wall of building with and including suitableBracket made out of25 mm dia GIlightgrade pipe, 1.00 m long bent to shape by cutting & weldingas required & directed and fixed withtwo Nos of FI clamps 35x6 mm to be tightened with suitable size of bolts, nut and washers and including painted withtwo coat of aluminium paint over a coat of red oxide primer, and including connecting the fittingto electric sourcewith & including twin twisted copper flexible wire of size 0.75 sqmm three core with suitable size flexible PVC conduitincluding all accessories and fixing arrangements for fixing the light fitting and writing the date of fixing on security light with permt marker complete all as specified and directed. 126 S & F in repair Wall mounting BLDCfanwith remote control, electric driven single phase, oscillating type 400 mm sweep,plastic ABS body with noise level 55 db,1500 RPM speed including all necessary parts reqd for its installation complete all as per specified and directed incl taking down the old unsv . 127 Supply and fixing in repairMCB SP 5 to 32 Amp rating 240V, 10KA C curve and current carrying capacity in the MCB DB complete with connection testing and commissioning.Complete all as specified and directed. 128 Supply and fixing in repair MCB SPN 40 to 63 Amp rating 240V, 10KA C curve and current carrying capacity in the MCB DB complete with connection testing and commissioning. Complete all as specified and directed. 129 Supply & fixing in repairof sheet metal enclosure Vertical TPN DB 4 Way double door, Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar for each phase with 2 Neutral bar, 2 Earthbar and Cable ties for Cable management, fully insulated busbar & shrouded Neutral bars, Improved Pan assembly for ease of installation, Prefitted masking sheet, Reversible Door for IP 43 DBs, With provision for 160 Amp MCCB as incomer and SP/TP MCBs as outgoingincl cutting/chasing of wall and make in good to the disturbed surface complete all as specified and as directed. 130 Supply & fixing in repairsheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 12 way with IP-54 protection double door complete with appropriate size bus bar and neutral link incl cutting/ chasing of wall and make in good to the disturbed surface complete all as specified and as directed. 131 Supply & fixing in repairsheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 8 way with IP-54 protection double door complete with appropriate size bus bar and neutral link incl cutting/chasing of wall and make in good to the disturbed surface complete all as specified and as directed. 132 Supply & fixing in repair sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 4 way with IP-54 protection double door complete with appropriate size bus bar and neutral link incl cutting/chasing of wall and make in good to the disturbed surface complete all as specified and as directed. 133 S&F in repairsub Main Wiring with two single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x6 sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 1x4 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in PVC Conduit medium grade not less than 25mm dia including dismantling of old unsv submain wiring complete all as specified and directed by Engineer-in-charge including taking down of existing un serviceable sub main wiring complete. 134 M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire 4mm dia as earth lead soldered and rivetedto earth plate by means of nuts, bolts, check nuts & washers, of galvanizediron or steelwith connected to test point and testing on completion including 15mm GI light grade pipe for earth leadprotection from earth point to earth plate, including provnadequate quantity of charcoal dust mixed with35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth platewith 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire meshwith and includingall necessary excavation& earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. . 135 Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 25sq mm 4 core incl taking down the old unservisible cable complete all as specifed and directed. 136 Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 16sq mm 2 core incl taking down the old unservisible cable complete all as specifed and directed. 137 Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 10 sq mm 2 core incl taking down the old unservisible cable complete all as specifed and directed. 138 Excavation in trenches in soft/loose soil N. exc 1.5 Mtr wide and not exc. 1.5 Meter deep and getting out including forming bottom surface for laying of cable complete all as specified and directed . 139 Returning filling including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified. 140 Removing surplus soil to a distance n.exc 50 Mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point all as specified. 141 M&L for drilling suitable dia horizontal bore holes below/under existing road surfaces / floors at a level not less than 0.60 mtr etc with using mechanical/ or manual devices as required at site including making good the disturbed surfaces to match with the existing after laying pipes complete all as specified and directed by Engineer-in-Charge. Note : Cost of equipment, tools and plant material (horizontal boring rig machine) required for boring shall be arranged by contractor at no extra cost to the Govt. 142 S & F of double wall corrugated pipe 75/63 mm dia with all fitting laid in bore holes/trenches/drain or fixed along with pole/wall includingFI clamps, nut, bolts etc. complete all as directed. 143 Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. 144 Supply and fixing MCCB 4 pole, 160 Amps, 50 Hz, Icu=35 KA at 415 volts with thermal magneticalongwith adjustable magnetic protection for current setting Icu=Ics = 100% with adjustable over load setting (minimum 70% to 100%) value from 10 to 15 times of related capacity standard complete all as specified anddirected.