Tender For Repair Replacement Of Ber Lifts In Kolkata Mil Station.; 1 NOTE (Applicable for all items) :-(i) The bidders/contractorsare advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.SCHEDULE A PART-I (B/R PORTION) 2 Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and directed 3 All as per item No. 1.001 above but 5 storey to 8 storey 4 All as per item No. 1.001 above but 9 storey to 12 storey 5 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.(upto 4 storey) 6 All as per item No. 1.004 above but 5 storey to 8 storey 7 All as per item No. 1.004 above but 9 storey to 12 storey 8 Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water complete all as specified and as directed.( upto 4 storey) 9 All as per item No. 1.007 above but 5 storey to 8 storey 10 All as per item No. 1.007 above but 9 storey to 12 storey 11 Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) area exc 1.5 sqm but not exc 4 sqm eachcomplete all as specified and directed (up to 4 storey high building). 12 All as per item No. 1.010 above but 5 storey to 8 storey 13 All as per item No. 1.010 above but 9 storey to 12 storey 14 Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) area n exc 1.5 sqm complete all as specified and directed (up to 4 storey high building). 15 Material and labour for 10 mm thick screed bed in cement mortar 1:4 mixed with Water Proofing Compound as per manufactures instructions and top surface finished even and smooth to recieve water proofing treatment complete all as specified and as directed .Note : Water Proofing Compound shall be measured and paid separately. 16 Material and labour for 18-20 mm thck machine cut Kota Stone slab flooring set and jointed with grey cement slurry mixed withpigment to match the shade of the slab including rubbing and polishing, laid over and including 15 mm thick screed bed in cement mortar (1:4) complete all as specified and as directed(upto 4 storey) 17 All as per item No. 1.015 above but 5 storey to 8 storey 18 All as per item No. 1.015 above but 9 storey to 12 storey 19 Material and labour for coloured non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match in floors etc. set and jointed in neat cement slurry over a bedding layer of scread bed 15 mm thick in CM 1:4 and pointed in white/colour cement to match.(upto 4 storey) 20 All as per item No. 1.018 above but 5 storey to 8 storey 21 All as per item No. 1.018 above but 9 storey to 12 storey 22 Material and labour for Granite (of any type) tiles 20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing in wall, jambs , pillars etc complete with 10 mm cement plaster 1:4 all as spdand directed EIC.(upto 4 storey) 23 All as per item No.1.021 above but 5 storey to 8 storey 24 All as per item No.1.021 above but 9 storey to 12 storey 25 Chipping of unsound /weak concrete materials from slabs , beams, columns ,lintel,chajja, fin , facia etc. by any meansincluding tapering all edges, making square shoulders of cavities air or sand blasting etc and cleaning of exposed concrete surface of lightly picking materials by air blasting or sand blasting incl foreign matrials , loose concrete/aggregate etcand disposal of all debris out of MOD land and complete all as specifiedandas directedby Engr-in-Charge. for 50mm average thickness for slabs/Chajja/beams 26 All as per item No.24 above but 5 storey to 8 storey 27 All as per item No.24 above but 9 storey to 12 storey 28 Removing of concrete all around reinforcement including from behind the reinforcing bars to give an average 25mm (but not less than 15mm clear air gap) by manual methods (using wire brushing, chiselling etc) and applying alkaline rust removing chemical followed by removing rust including from behind the reinforcing bars by emery paper and cleaning the area throughly by water and allow it to dry all as per manufacturer,s instruction to give it a totally rust free finished steel surfaceupto 4 storey complete all as specified and directed. 29 All as per item No 1.027 above but 5 storey to 8 storey 30 All as per item No 1.027 above but 9 storey to 12 storey 31 Material and labour for providing single coat of epoxy bond adhesive of prepared non metallic surface (existing surface) and applying by brush all as per manufactures instruction/specification. The bonding agent shall have minimum compressive strength of 40 N/Sqmm upto 4 storey complete all as specified and directed. 32 All as per item No1.030 above but 5 storey to 8 storey 33 All as per item No 1.030 above but 9 storey to 12 storey 34 Supply and application of Epoxy Zinc rich primer on the prepared steel surface by brush the primer shall have a minimium specific gravity 1.75 minimum weight film thickness/coat 40 microns and minimum adhesive bond strength with steel is 1.5N/mm2upto 4 storey High complete all as specified and directed by Engr-in-charge. 35 All as per item No 1.033 above but 5 storey to 8 storey 36 All as per item No 1.033 above but 9 storey to 12 storey 37 Material and labourfor providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-50 to the effected beam, column etc. The micro concrete shall have a minimium 1 day compressive strength of 10 Mpa and 28 days strength of 50 Mpa, minimum tensile strength 5N/mm2 @ 28 days, minimium flextural strength 5N/mm2 @ 28days and complete all as specified and directed by Engr-in-Charge ofColumn, upto 4 storey High. 38 All as per item No 1.036 above but 5 storey to 8 storey 39 Supply, mixing and application two component structural grade polymer modified reinstatement morter, where local spalling has taken place or shuttering is not possible. The morter can be applying in layers not exceeding 6mm thick in each layer in and upto any thickness in smaller vertical pockets and upto any thickness in horizontal applications. The mortar should have a minimium compressive strength 12N/mm2 in 1 day and 45N/mm2 in 28 days. Minimum flexural strength should be 8N/mm2 in 28 days. A modified styrene butadience emulsion for use as a bonding aid and gauging liquid for cementious system to be mixed with cement slurry before the application of modified polymer mortar to be used @ 6 ltr/bag of cement. The bonding agent should have minimium compressive strength 24N/mm2. Minimum tensile strength 3.5N/mm2, minimium flexural strength 6.5N/mm2 complete all as specified and directedby the Engr-in-charge upto 25 mm average thickness and upto 4 storey High. Make :- Sika/Fosroc NOTE :- Cement and sand morter in proportion of 1:2 graded coarse sand with polymer admixed in proportions approved by Engr-in-charge. 40 All as per item No 1.038 above but 5 storey to 8 storey 41 All as per item No 1.038 above but 9 storey to 12 storey 42 Material and labour for applying polymer modified cement mortar rendering 15 mm thick in CM 1:3 on wall duly mixing polymer modifier Nitobond SBR of M/s Forsoc Chemical India (Pvt) Ltd or Hind Styrene BR of Hindcon Chemical Ltd or equivalent make of M/s Pidilite Industries @ 7 Litre per bag of cementcomplete finished even and smooth without using extra cement complete all as specified and as per manufacturers specification. 43 All as per item No.1.041 above but 5 storey to 8 storey 44 All as per item No.1.041 above but 9 storey to 12 storey 45 Material and labour for introducing new reinforcement bars for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc all as specified and directed by Engr-in-charge. upto 12 mm dia bar upto 4 storey High. 46 All as per item No 1.044 above but 5 storey to 8 storey 47 All as per item No 1.044 above but 9 storey to 12 storey 48 Material and labour for applying curing compound over concrete surfaces as per manufactures instruction complete all as specified and directed by Engr-in-charge upto 4 storey High. 49 All as per item No 1.047 above but 5 storey to 8 storey 50 All as per item No 1.047 above but 9 storey to 12 storey 51 Supply and fixingpowder coated anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified 52 Supply and fixing powder coated anodised aluminium window and ventilator shutters, side hung type with sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays hinges and handles (2 no.) etc with 4mm thick tinted/frosted glass ordinary quality as per manufactures instruction complete all as specified 53 Supply and fixingAnodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. 54 Material and labour for 25mm thick cement concrete type B-0, 1:2:4 using 12.5mm graded aggregate in sub bases of floors complete all as specified and directed. 55 Material and labour for Water Proofing Treatment on existing cleaned RCC Roof with the following Specifications and Manufacturers instructions, complete all as specified and as directed:-(a) Preparing fully dried plastered surface as per IS:3067-1966, for further treatment.(b) Applying Bitumen Primer conforming to IS-3384-1986, over the Cleaned Plastered Surface @ 0.3 Litre per Sqm.(c) Applying a layer of APP based Polymeric Membrance; 3.0mm thick (minimum) weighing 3.50 Kilogram per Square Meter (reinfored) with Polyster Non Woven Fabric weighing not less than 160 Grams per Square Metre by Torch application. The overlaps shall be minimum 100mm on the Transverse direction and 75mm on Longitudinal direction.(d) Applying one coat of Aluminium Paint @ 0.10 Litre per Sqm over APP based Polymeric Membrane. 56 Supply only integral water proofing compound (ISIgrade only) 57 Material and labour forcutting out cracks to V section in existing roofs of terracing cleaning out, wetting, grouting, with cement sand slurry 1:3 complete all as specified and as directed 58 Material and labour forTMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.(upto 04 storey) 59 All as per item No. 1.057above but 5 storey to 8 storey 60 All as per item No. 1.057 above but 9 storey to 12 storey 61 All as per item No. 1.057 above but 6 to 8mm dia n stirrups, spacers and binders complete all as specified and as directed. (upto 04 storey) 62 All as per item No. 1.060 above but 5 storey to 8 storey 63 All as per item No. 1.060 above but 9 storey to 12 storey 64 Material and labour brick work with fly ash brick straight or curved on plan exc. 6m mean radius, built in cement mortar (1:6) completeall as specified and directed by Engineer-in-Charge. 65 All as per item No. 1.063 above but 5 storey to 8 storey 66 All as per item No. 1.063 above but 9 storey to 12 storey 67 M & L for brick work with fly ash bricks old size, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed. 68 All as per item No. 1.066 above but 5 storey to 8 storey 69 All as per item No. 1.066 above but 9 storey to 12 storey 70 Demolition of PCC in ground floorand pavings not exc 15 cm thickness below or above ground level complete all as specified and directed. 71 All as per item No. 1.069 above but 5 storey to 8 storey 72 All as per item No. 1.069 above but 9 storey to 12 storey 73 Demolition of cement concrete (reinforced) in ground floor and paving not exceeding 15 cm thick (below or above G.L) all as specified and directed 74 All as per item No. 1.072 above but 5 storey to 8 storey 75 All as per item No. 1.072 above but 9 storey to 12 storey 76 Material and labour for Any thick PCC (1:3:6) type C2(20 mm graded stone agg) as in flooring, finished even and smooth with using extra cementcomplete all as specified and directed. 77 All as per item No. 1.075 above but 5 storey to 8 storey 78 All as per item No. 1.075 above but 9 storey to 12 storey 79 Material and labour for10 mm thick rendering in cement mortar (1:6) to brick or concrete wall surfaces, finished even and smooth without using extra cement all as specified and as directed by the Engineer-in-Charge. 80 Material and labour for Rendering on ceiling 5 mm thick in cement mortar (1:3) onof concrete surface finished even and smooth with out using extra cement complete all as specified and directed. 81 All as per item No. 1.079 above but 5 storey to 8 storey 82 All as per item No. 1.079 above but 9 storey to 12 storey 83 Material and labour for 15mm thick plastering on fair face of brick wall and concrete surface in CM (1:4) surface finished even and fair complete all as specified and directed. 84 All as per item No. 1.082 above but 5 storey to 8 storey 85 All as per item No. 1.082 above but 9 storey to 12 storey 86 Material and labour for Complete removal of existing treatment of old surface and applying two coat of OBD incl 1mm thick birla white putty etc all as specified and directed complete all as specified and directed 87 All as per item No. 1.085 above but 5 storey to 8 storey 88 All as per item No. 1.085 above but 9 storey to 12 storey 89 Material and labour for prepration of new plasterd surface and applying two coat of oil Emulsion distamper etc complete all as specified and directed. 90 Material and labour for one coat of white wash on old decorated surface of internal walls incl preparation complete all as specified and directed by Engr-in-Chargeupto 4 storey bldg. 91 All as per item No. 1.089 above but 5 storey to 8 storey 92 All as per item No. 1.089 above but 9 storey to 12 storey 93 Material and labour for one coat of white wash on old decorated surface of ceiling incl preparation complete all as specified and directed by Engr-in-Chargeupto 4 storey bldg. 94 All as per item No. 1.092 above but 5 storey to 8 storey 95 All as per item No. 1.092 above but 9 storey to 12 storey 96 Material and labour for three coat of white wash on new decorated surface of internal walls incl preparation complete all as specified and directed by Engr-in-Charge upto 4 storey bldg. 97 All as per item No. 1.095 above but 5 storey to 8 storey 98 All as per item No. 1.095 above but 9 storey to 12 storey 99 Material and labour for three coat of white wash on new decorated surface of ceiling incl preparation complete all as specified and directed by Engr-in-Charge. 100 All as per item No. 1.098 above but 5 storey to 8 storey 101 All as per item No. 1.098 above but 9 storey to 12 storey 102 Taking out/Stripping of old Roof treatment membranes/Tar felt incl layer ofcement mortar of any type carefully from roof surfaces (without damaging roof ) and incl preparation of old roof surfaces by picking, sweeping, cleaning and washing down with water to remove dust & receive new treatment complete all as specified and directed. 103 Material and labour for 100mm thick PCC 1:2:4 type B-1 using 20 mm graded aggregate finished even and smooth finishing cement concrete surface even and smooth without using extra cement complete all as specified. 104 Supply and fixing in repair 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial typecomplete all as spd and directed. (Upto 4 storey bldg) 105 All as per item No. 1.103 above but 5 storey to 8 storey 106 All as per item No. 1.103 above but 9 storey to 12 storey 107 Dismantling wrough iron or mild steel work of any description not otherwise provided for complete all as directed. 108 Supply and fixing in repairs Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete Gauzed with glazing bars, dovetailed or welded complete including taking down old steel window all as specified and as directed by Engineer-in-charge. (Upto 4 storey bldg) 109 All as per item No. 1.107 above but 9 storey to 12 storey 110 Supply and fixingin repairs Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete Gauzed without glazing bars, dovetailed or welded complete including taking down old steel window all as specified and as directed by Engineer-in-charge. 111 Supply and fixing in repair framed work such as grills, gratings, etc. with ends of bars shouldered and /or riveted or forged into spikes, framed guard bars barred iron doors; ladders framed alusters; wald ways; railings; framework of water tanks and similar work confrming to Fe-290 Gde -E 165. 112 Supply and fixing in repair framed work such as grills, gratings, etc. with ends of bars shouldered and /or riveted or forged into spikes, framed guard bars barred iron doors; ladders framed alusters; wald ways; railings; framework of water tanks and similar work confrming to Fe-290 Gde -E 165.(9 storey to 12 storey) 113 Supply and fixing hard drawn steel wire fabric weight exceeding 4.0 Kg/Sqm cut to lengths, bent to shape required and welded to angle /channel complete all as specified and directed by Engineer-in-Charge. 114 Supply and fixing 100 mm long butt hinges medium weight, cold rolled mild steel and fixed complete complete all as spd and directed.(Upto 4 storey bldg) 115 Supply and fixing aluminium anodised handles cast type, anodised 150mm long complete all as spd and directed.(Upto 4 storey bldg) 116 All as per item No. 1.114 above but 5 storey to 8 storey 117 All as per item No. 1.114 above but 9 storey to 12 storey 118 Supply and fixing aluminium anodised tower bolt cast type, anodised 200 mm long complete all as spd and directed.(Upto 4 storey bldg) 119 All as per item No. 1.117 above but 5 storey to 8 storey 120 All as per item No. 1.117 above but 9 storey to 12 storey 121 Supply and fixing 300mm long sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bots and sliding bolts of extruded or cast aluminium alloy (Upto 4 storey bldg) 122 All as per item No. 1.120 above but 5 storey to 8 storey 123 All as per item No. 1.120 above but 9 storey to 12 storey 124 Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc, upto 4 storey bldg all as spd and directedby the Engr-in-charge 125 All as per item No. 1.123 above but 5 storey to 8 storey 126 All as per item No. 1.123 above but 9 storey to 12 storey 127 Material and labour for Green / White marble work 18 to 20 mm thick (table rubbed and polished ) in steps, jambs, piller, window cills, cooking platform and including 15mm screedbed of cement mortar (1:4) including pointing with white cement (1:2) using marble dust with admixture pigment to match with marble shade complete all as specified and directed. 128 All as per item No. 1.126 above but 5 storey to 8 storey 129 All as per item No. 1.126 above but 9 storey to 12 storey 130 Supply and fixing 4mmplain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area of glass not exc 0.5 sqm each pane. (Upto 4 storey bldg) 131 All as per item No. 1.129 above but 5 storey to 8 storey 132 All as per item No. 1.129 above but 9 storey to 12 storey 133 Hacking out old brokenglass (any thickness, size, quality or description) from wooden frames/steel/aluminiumframes glazed with putty or fixed with beads complete. 134 Supply and fixingstainless steel wire cloth, 0.36 mm dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanized wire staples incl of dismentling all as directed by Engr in charge.(Upto 4 storey bldg) 135 All as per item No. 1.133 above but 5 storey to 8 storey 136 All as per item No. 1.133 above but 9 storey to 12 storey 137 Material and labour for Pressed steel frames for doors with one or more rebates size of frame 105 x 60 mm including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed.Note:- Pressed Steel Frame should be filled with PCC 1:3:6 Type C-0 (Using 12.50mm graded stone aggregate) and cost of PCC shall be deemed included in quoted rate 138 All as per item No. 1.136 above but 5 storey to 8 storey 139 All as per item No. 1.136 above but 9 storey to 12 storey 140 M&L for PCC 1:3:6type C-1 using 20mm graded stone agg as in bedblocks/hold fast complete all as specified and directed 141 All as per item No. 1.139 above but 5 storey to 8 storey 142 All as per item No. 1.139 above but 9 storey to 12 storey 143 Demolition of brick work or stone masonary built in cement mortor including all quoins & jambs etc. complete all as specified and directed 144 All as per item No. 1.142 above but 5 storey to 8 storey 145 All as per item No. 1.142 above but 9 storey to 12 storey 146 Cutting opening in cement concrete walls (any description)With or without reinforcementfor door, window and other openings(with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, etc.(upto 4 storey) 147 All as per item No. 1.145 above but 5 storey to 8 storey 148 All as per item No. 1.145 above but 9 storey to 12 storey 149 Cutting opening in cement concrete walls (any description) With cut of reinforcement for door, window and other openings(with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, etc.(upto 04 storey) 150 All as per item No. 1.148 above but 5 storey to 8 storey 151 All as per item No. 1.148 above but 9 storey to 12 storey 152 M&L for RCC(Nominal Mix) in type-A1 1:1.5:3 (20mm graded aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specfified and directed 153 All as per item No. 1.151 above but 5 storey to 8 storey 154 All as per item No. 1.151 above but 9 storey to 12 storey 155 Use and waste formwork square, rectangular or ploygonal fair finished surfaces to slides of pillars, post, struts, piers, columns and stanchions complete all as specified. 156 All as per item No. 1.154 above but 5 storey to 8 storey 157 All as per item No. 1.154 above but 9 storey to 12 storey 158 Use and waste for formwork to side and soffits of floor or roof beams, beam haunching, girders, bressummers, lintel, cantilevers, shelves incl support overhangs etc also splays between floors and beams etc all as sped & directed for rough finished surfaces including edges complete all as specified and directed. 159 M&L for two coats of synthetic enamel paint over a coat of pink primer areaexc.10cm width or girthover new wooden surfacesincluding preparationof surface complete complete in all respect as spd 160 All as per item No. 1.158 above but 5 storey to 8 storey 161 All as per item No. 1.158 above but 9 storey to 12 storey 162 M&L for one coat of synthetic enamel paint on oldwooden surfacesincluding preparationof surface complete complete in all respect as specified (up 9 to 12storey High of building) 163 Material & labour preparation of new steeland iron surfaces of any description areaexc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat ofred oxide and zinc chrome primer,complete in all respect as specified. 164 All as per item No.1.162 above but 5 storey to 8 storey 165 All as per item No.1.162 above but 9 storey to 12 storey 166 Material and labour forPreparing new plastering Surfaces of wall applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces all as specified and directed. 167 Material and labour for complete removal of old Surfaces of wall applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces all as specified and directed. 168 All as per item No.1.166 above but 5 storey to 8 storey 169 All as per item No.1.166 above but 9 storey to 12 storey 170 Supply and fixing Joist, channel, angle, or tee sections,fixed independently, without connecting plates, etc. Fe 410 W (Gde-E-250) quality A etc all as sped & directed 171 All as per item No.1.169 above but 5 storey to 8 storey 172 All as per item No.1.169 above but 9 storey to 12 storey 173 Supply and fixing Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment (upto 04 storey) 174 All as per item No. 1.172 above but 5 storey to 8 storey 175 All as per item No. 1.172 above but 9 storey to 12 storey 176 Material & labour for preparation of old steeland iron surfaces of any description areaexc 10 cm width or girth and applying one coat of synthetic enamel paint complete in all respect as specified. 177 All as per item No. 1.175 above but 5 storey to 8 storey 178 All as per item No. 1.175 above but 9 storey to 12 storey 179 SCHEDULE A PART-II ( E/M PORTION) 180 Dismantling and taking down carefully all electrical and mechanical components, assemblies, sub systems such as drives, machine, control panels, lift car, ropes, guides, counterweights, rails, beams and doors, electrrical wirings, control wiring etc. complete of existing beyond economical repairs (BER) lifts including taking down all steel work and components from machine room, lift shaft, lift pit and stacking neatly all retrieved components deposit to departmental store for safe custody and for persual of BOO and making good the disturbed surface in machine room at all landings and in lift door faces to mactch with existing surfaces, all as directed at site by Engr in charge for the foloowing lifts :( Making good to disturbed surfaces will be paid under relevant items listed in B/R works here in after) 181 Dismantling of the old 13 passenger lift machine ( G+12) and all connected accessories and depositing in the mes store yard complete all as specified and directed(Bldg- Hooghly View) 182 Dismantling of the old 10 passenger lift machine ( G+12) and all connected accessories and depositing in the mes store yard completeall as specified and directed(Bldg T V -16) 183 Dismantling of the old 13 passenger lift machine ( G+10) and all connected accessories and depositing in the mes store yard completeall as specified and directed (Bldg- P-197 & 198 BMC) 184 Dismantling of the old 08 passenger lift machine ( G+10) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg no P-197-02, P-198-02 (BMC), Map A-01, Map B -01(Vijay Durg) 185 Dismantling of the old 06 passenger lift machine ( G+10) and all connected accessories and depositing in the mes store yard completeall as specified and directed (Bldg No TV-18) 186 Dismantling of the old 08 passenger lift machine ( G+9) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg No- JSA I & II , Vijay Durg) 187 Dismantling of the old 8 passenger lift machine ( G+7) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg - P-173 BMC) 188 Dismantling of the old 13 passenger lift machine ( G+6) and all connected accessories and depositing in the mes store yard completeall as specified and directed (Bldg No - P-127 (BMC) 189 Dismantling of the old 8 passenger lift machine ( G+6) and all connected accessories and depositing in the mes store yard completeall as specified and directed (Bldg No - Map C (Vijay Durg), T V - 15) 190 Dismantling of the old 6 passenger lift machine ( G+5) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg No - TV 13 and TV-14) 191 Dismantling of the old 8 passenger lift machine ( G+5) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg No - P-1 (Vijay Durg) 192 Dismantling of the old 6 passenger lift machine ( G+4) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg No - O-32 IGS) 193 Dismantling of the old 8 passenger lift machine ( G+2) and all connected accessories and depositing in the mes store yard completeall as specified and directed (Bldg No - MES IB (Vijay Durg) 194 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+12 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 13 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :Hoogly View) 195 (a) Type & capacity: 13 Passenger, 884 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+12 floor (h) Serving :G+ 12 upper floors- (13 Stops, 13 landings, 13 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 196 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 197 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 198 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4,5,6,7,8,9,10,11,12(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 199 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 200 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 201 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+12 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 10 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :TV 16) 202 (a) Type & capacity: 10 Passenger, 680 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+12 floor (h) Serving :G+ 12 upper floors- (13 Stops, 13 landings, 13 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 203 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 204 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 205 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4,5,6,7,8,9,10,11,12(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 206 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 207 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 208 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+10 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 13 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :P197-1BMC, P198-1 BMC) 209 (a) Type & capacity: 13 Passenger, 884 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+10 floor (h) Serving :G+ 10 upper floors- (11 Stops, 11 landings, 11 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 210 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 211 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 212 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4,5,6,7,8,9,10(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 213 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 214 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 215 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+10 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :P197-2 BMC, P198-2 BMC, MAP A-1 VD, MAP B-1 VD) 216 (a) Type & capacity: 8 Passenger, 544 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+10 floor (h) Serving :G+ 10 upper floors- (11 Stops, 11 landings, 11 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 217 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 218 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 219 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4,5,6,7,8,9,10(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 220 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 221 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 222 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+10 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 6 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :TV18 ALIPORE) 223 (a) Type & capacity: 6 Passenger, 408 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+10 floor (h) Serving :G+ 10 upper floors- (11 Stops, 11 landings, 11 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 224 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 225 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 226 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4,5,6,7,8,9,10(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 227 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 228 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 229 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+9 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :JSA ENCLAVE BLOCK1 AND BLOCK 2- 02 NOS) 230 (a) Type & capacity: 8 Passenger, 544 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+9 floor (h) Serving :G+ 9 upper floors- (10 Stops, 10 landings, 10 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 231 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 232 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 233 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4,5,6,7,8,9(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 234 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 235 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 236 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+7 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :P173 BMC-01) 237 (a) Type & capacity: 8 Passenger, 544 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+7 floor (h) Serving :G+ 7 upper floors- (8 Stops, 8 landings, 8 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 238 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 239 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 240 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4,5,6,7(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 241 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 242 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 243 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+6 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 13 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :P127 BMC-01) 244 (a) Type & capacity: 13 Passenger, 884 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+6 floor (h) Serving :G+ 6 upper floors- (7 Stops, 7 landings, 7 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 245 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 246 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 247 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4,5,6(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 248 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 249 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 250 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+6 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :MAPC VD-01, TV15 ALIPORE -01) 251 (a) Type & capacity: 8 Passenger, 544 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+6 floor (h) Serving :G+ 6 upper floors- (7 Stops, 7 landings, 7 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 252 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 253 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 254 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4,5,6(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 255 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 256 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 257 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+5 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :P/1 VD-03 NOS) 258 (a) Type & capacity: 8 Passenger, 544 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+5 floor (h) Serving :G+ 5 upper floors- (6 Stops, 6 landings, 6 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 259 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 260 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 261 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4,5(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 262 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 263 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 264 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+4 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 6 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :O32 IGS- 01) 265 (a) Type & capacity: 6 Passenger, 408 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+4 floor (h) Serving :G+ 4 upper floors- (5 Stops, 5 landings, 5 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 266 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 267 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 268 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 269 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 270 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 271 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+5 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 6 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :TV13 ALIPORE-01, TV14 ALIPORE-01) 272 (a) Type & capacity: 6 Passenger, 408 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+5 floor (h) Serving :G+ 5 upper floors- (6 Stops, 6 landings, 6 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 273 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 274 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 275 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2,3,4, 5(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 276 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 277 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 278 Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+2 upper floors with ACVariable Voltage Variable Frequency (VVVF) Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the carto announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given belowcomplete all as specified and directed:-(Location of lift :MES IB VD-01) 279 (a) Type & capacity: 8 Passenger, 544 Kgs - Gearless (b) Speed:1.5 M/Sec (c) Type of Drive:VVVF Regenerative (Closed Loop)(d) Type of control :Microprocessor based Simplex full Collective control (e) Location of Machine Room:Top of Building (As existing) (f)Machine : Gearless Machine(g) Travel :As per existing site to serve G+2 floor (h) Serving :G+ 2 upper floors- (3 Stops, 3 landings, 3 openings) (j)Existing Well size:As existing at site (as per Appx `A attached) 280 (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. 281 (l) Head Room : As per existing site. (m) Power supply :415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule.(p)Car Enclosure :Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code.(q)Car Size : As per NBC 2016 or other relevant BIS code of latest edition..(r) Flooring:18-20mm thick granite flooring. (s) No of Entrance :One location - Front. 282 (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finishDoor.(v) Clear opening for door : As per existing site.(w) Floor Designation : 0,1,2(x)Indicators : Car & Landings: Direction & Position Indicator/ call registration LEDs(y)Roping : Lift rope shall be provided as perNBC-2016 andIS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square andfactor of safety shall be 8.6(z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided.(ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad)Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be providedfor elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. 283 (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided.(af)Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag)Micro- Stroke illuminated push buttons shall be provided.(ah) All landing door shall be one hour fire rated.(aj) Car door lock shall be provided.(ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided.(al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finishedstainless steel (1.5mm) panel to be provided on all side above hand rails.(am) MS Pit Ladder shall be provided.(an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline).(ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. 284 (ar) Hall fixtures face plate : Stainless steel (Hairline).(as) Hall button arrangement :Hall button with FPI.(at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Firemans service. Emergency car light unit,Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised withcar door opening/closing system.(au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where requiredshall be provided by the contractor(av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car. 285 Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtrdeep below ground level with top edge of the plate notless than 1.5 m below ground level connetced withgalvanised strip of size 25 x 4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed by the Engr-in-Charge. 286 Supply and fixing in repair for earth continuity conductor or main earthing lead fixed to wall onporcelain insulator or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for wall/ roof etc. as required by 25X4mm galvanised iron strip complete all as specified and directed. 287 Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 25 Sqmm 3.5 core in trench/duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge. 288 Supply and fixingMCB TPN DB made up with sheet metal double door, phosphorised, power coated, neutral link, earth bar and din rail, 4 way TPN with 200 amps rated bus bar, 415 volts complete all as specified and as directed. 289 Supply and fixing isolator 40 Amps 415 Volts FP with rapturing capacity 10KAincluding taking down of old one complete all as specified. 290 Supply and fixingMCB 5 to 32 amps single polecomplete all as specified. 291 Supply and fixing MCB DP 40 to 63 amps 240 volts 10KA breaking capacitycomplete all as specified.