Tender For Repair/Maintenance /Servicing Of Voltage Stabalilizers, Dg Sets, Lightening Protection, Water Purifier, Cooling Appliance And Other Connected Works At Pooh And Sumdo Area Under Ge 863 Ews.; 1 Repair / maintenance and servicing of water cooled / air cooled DG Set including replacing engine oil, greasing and oiling, checking of valve & nozzle, changing of diesel filter, oil filter, checking of defective parts complete, re-commissioning and testing complete allas specified and directed by Engineer-in-charge for the following capacities:-(a) 50 KVA - 02 Nos. & 160 KVA - 01 No at Pooh 2 (b) 10 KVA - 01 No. & 30 KVA - 03 Nos. at Sumdo 3 (c) 12 BHP - 01 No. Diesel engine pumpset at SumdoNote :- Spare parts like filters, engine oil and other spares shall be measured and paid separately as supply only under relevant items of Sch A/BOQ.Fixing/ labour charges for replacement of spares deemed to be included in the unit rate quoted. 4 Supply only element diesel filter with gasket of existing size and model DG set capacity mentioned in item No 1 (a) to (c) complete allas specified and directed by Engineer-in-charge . 5 Supply only element oil filter with gasket of existing size and model mentioned in item No 1 (a) to (c) complete allas specified and directed by Engineer-in-charge . 6 Supply only inner and outer air cleaner element of existing size and model mentioned in item No 1 (a) to (c) complete allas specified and directed by Engineer-in-charge . 7 Suppply only element bypass filter with gasket of existing size and model / make mentioned in item No 1 (a) to (c) complete allas specified and directed by Engineer-in-charge . 8 Supply only lubrication oil SAE-40 (20w-40 grade) complete allas specified and directed by Engineer-in-charge .Make : Servo/HP/BPCL/Castrol) 9 Dismantling / In site Cleaning and calibration of the fuel tank of various capacities, by using K oil and remove sludge accumulated inside the tank, replacement of fuel tank strainer, cap and unserviceable fuel indicatior including refixing after repair/ welding the leakage portions complete all as specified and directed by Engr-in-Charge 10 S & F connecting and testing battery lead (Heavy duty) PVC insulated with multi stranded copper conductor single core of size 25 sqmm one side fixed with clamp and other side fixed with brass battery terminal for 2 mtr length suitable colour coding for phase and earth complete allas specified and directed by Engineer-in-charge 11 S & F in replacement of battery maint free type 100Ah complete allas specified and directed by Engineer-in-charge (Make: Exide/Amaron/TATA) 12 Disconnecting & taking out the non-functional voltage stabilizer of any description and in any position & opening of servo operated oil cooled voltage stabilizer of cap 100 KVA , single/three phase, 50 Hz and draining out of transformer oil, replacement of UNSV/defective wiring parts as per existing sizes, dimmerstat, carbon brush, servo motor of existing capacity, control card, etc and complete servicing including filteration & refilling of transformer oil with top-up of new oil if required, reassembling, connecting and testing complete all as specified and directed by Engr-in-Charge 13 All as per item No. 10 here in before but capacity 250 KVA, three phase complete allas specified and directed by Engineer-in-charge.Note for Item No. 10 &11 :- Replacment of spare parts/accessories shall be measured & paid seperately as Supply Only on relevant items complete allas specified and directed by Engineer-in-charge 14 Supply only Dimmerstat as per existing size and make complete allas specified and directed by Engineer-in-charge . 15 Supply only Servo control motor Cap 10 Kgs, 60 RPM & 240 volts for existing voltage stabilizer as per existing size and make complete allas specified and directed by Engineer-in-charge 16 Supply only Push Buttons for adjustment of voltage complete allas specified and directed by Engineer-in-charge . 17 Supply only Carbon brush as per existing size and make complete allas specified and directed by Engineer-in-charge . 18 Supply only voltmeter digital type, 0-500 volts, 96mm x 96mm square size including wiring, suitable for voltage stabilizers complete allas specified and directed by Engineer-in-charge .Make: AE/L&T/Seimens 19 Supply only indicator lamp pilot type (RYB) complete allas specified and directed by Engineer-in-charge . 20 Supply only selector switch suitable for voltmeter, 3 way, ON/OFF type complete allas specified and directed by Engineer-in-charge Make : GEPC/PAAS/Concord/Vaishno/Legrand Lexic 21 Supply only PCB card as per sample complete allas specified and directed by Engineer-in-charge . 22 Supply only Transformer oil EHV conforming to IS-335 of 1983 having high dielectric strength not less than 50KV in drums/barrel complete allas specified and directed by Engineer-in-charge . 23 S&F in replacement of copper strip 20 x 3.15 mm thick with & incl suitable porcelain/FRP insulators, saddle and fixing screws etc for roof conductors and down conductors above ground level complete allas specified and directed by Engineer-in-charge 24 S&F in replacement of aluminium strip 25 x 3.15 mm thick with & incl suitable porcelain/FRP insulators, saddle and fixing screws etc for roof conductors and down conductors above ground level complete allas specified and directed by Engineer-in-charge 25 S&F in repair air termination single pointed Copper rod 12mm dia and 300 mm long incl fixing on roof with MS clamp and nut, bolt and washers etc complete allas specified and directed by Engineer-in-charge 26 S&F in repair air termination single pointed aluminium rod 12mm dia and 300 mm long incl fixing on roofl with MS clamp and nut, bolt and washers etc complete allas specified and directed by Engineer-in-charge 27 S&F in replacement test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete allas specified and directed by Engineer-in-charge 28 M&L Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI earth strip32 x 6 mm dia protected by GI pipe light grade 40mm dia, 20 mm medium grade for watering with funnel including test point up to 7.5 meter from earth pit, common salt, charcoal dust and connected to test point by means of bolts and nuts washers made out of GI all as shown in Electrical plate No 5 of SSR part I includingnecessary earth work and excavation in any type of soil PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type mix cover slab with 6mm dia MS bars at 100mm dia both ways with MS hook 6mm dia MS bars etc complete allas specified and directed by Engineer-in-charge 29 Servicing of Window / Split AC 1.5 / 2 TR capacities any make by opening the indoor/outdoor unit, cleaning the air filter, condenser including complete bodyof the unit with brush and air blower, washing with cleaning detergent & fresh water, greasing fan motor, rectification of loose electric connections and replacement of unserviceable knobs of electrical items complete allas specified and directed by Engineer-in-charge Note : Replacement of spare parts will be measured and paid separately under relevant items of Sch A 30 Supply only starting capacitor 80-100 mfd complete allas specified and directed by Engineer-in-charge 31 Supply only running Capacitor 36 mfd complete allas specified and directed by Engineer-in-charge 32 Supply only starting relay complete allas specified and directed by Engineer-in-charge 33 Supply only Over load protector complete allas specified and directed by Engineer-in-charge 34 Supply only thermostat complete allas specified and directed by Engineer-in-charge 35 Supply only Air Filter complete allas specified and directed by Engineer-in-charge 36 Removing the existing defective / short circuited hermetically sealed compressor unit from the ACs and replace with the same company rewoundsealed compressor unit of appropiate make / model for 1.5 TR AC complete allas specified and directed by Engineer-in-charge . 37 Servicing, maintenance and repairsto Refrigerator / Deep Freezerof capacity 280 to 386 Ltrs of any make and model including periodical cleaningto condenser coil and compresser, Replacement of defective spares will be measured and paid separately under relevant items as under complete allas specified and directed by Engineer-in-charge. Note : Replacement of spare parts will be measured and paid separately under relevant items of Sch A 38 Supply & fix in replacement of Voltage Stabilizer for AC/Deep Freezer automatic operation/single phase AC supply 230 Volt/50 HZ naturally air cooled indoor type designed for input variation between 130 V to 280 Volt with output Voltage stabilizer at 230 V of capoacity 2 to 5 KVA complete allas specified and directed by Engineer-in-charge . 39 Supply only Starting Relay complete allas specified and directed by Engineer-in-charge. 40 Removing the existing defective / short circuited hermetically sealed compressor unit from the Refrigerator, Replacement of the same with company rewoundsealed compressor unit of appropriate make / model for Refrigerator cap: 280 to 380 ltrs complete allas specified and directed by Engineer-in-charge 41 Gas charging with refrigerantto ACs/water cooler/Deep freezer /Refrigerator including arresting of existing leakage by brazing work complete allas specified and directed by Engineer-in-charge 42 S & F in replacement of solar street light fitting 12 watt having high efficiency Mono Crystalline Solar PV Module, Lithium Ferro Phosphate battery with in-built BMS technology, High Efficacy LED, MPPT Solar Charge Controller and Aluminium Extruded body & specially programmed to automatically control the dimming and brightness of light, which increases the backup time, etc including fixing on existing pole complete allas specified and directed by Engineer-in-charge 43 M&L for servicing, cleaning of water purifier 8/10 LPH, any make & model complete allas specified and directed by Engineer-in-charge Note: Replacement of following items shall be measured & paid separately as Supply only 44 Supply only Sediment filter complete allas specified and directed by Engineer-in-charge . 45 Supply only Carbon filter complete allas specified and directed by Engineer-in-charge 46 Supply only UV filter complete allas specified and directed by Engineer-in-charge 47 Supply only Membrane complete allas specified and directed by Engineer-in-charge 48 Supply only Pre-filter candle complete allas specified and directed by Engineer-in-charge 49 M&L for servicing, cleaning of Industrial type RO plant 50 to 100 LPH, any make & model complete allas specified and directed by Engineer-in-charge .Note: Replacement of following items shall be measured & paid separately as Supply only 50 Supply only pressure regulator complete allas specified and directed by Engineer-in-charge . 51 Supply only Sediment Pre-filter complete allas specified and directed by Engineer-in-charge. 52 Supply only Carbon filter complete allas specified and directed by Engineer-in-charge . 53 Supply only RO membrane complete allas specified and directed by Engineer-in-charge. 54 Supply only Post Caron inline filter complete allas specified and directed by Engineer-in-charge 55 Supply only Pressure pump booster complete allas specified and directed by Engineer-in-charge . 56 Schedule of Credit