|
| 1 | M&L for preparation of old bituminous surfaces including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and road marking 2.5mm thick centre lines, stop lines, dashes, arrows etc. and the like on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed. |
| 2 | Demolition of brick masonry built in cement mortar complete all as specified and directed. |
| 3 | M&L for old size brick work with sub class \"B\" bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 4 | Excavation in trenches not exc 1.5 mtr wide and n.exc. 1.50m deep as in foundation of drain n.exc. 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed. |
| 5 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15cm thickness complete all as specified and directed. |
| 6 | M&L for cement concrete type C2 (1:3:6 ) using 40 mm grade graded coarse agg. in floor, foundations, filling and mass concrete etc. complete all as specified and directed. |
| 7 | Removing excavated material exc. 50 m andupto a total distance of 250 m. of soil, complete all as specified and directed. |
| 8 | Demolition of lime concrete/hardcore (un-reinforced) in ground floors and pavings n exc 15cm thickness complete all as specified and directed. |
| 9 | M&L broken stone hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed. |
| 10 | M&L 75 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate, including necessary formwork and finishing the surface of cone, even & rough to recieve the topping layer complete all as specified and directed. |
| 11 | M&L 150 mm thick cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using400 kg of cement per cubic metre, including necessary use & wasteof formwork for laying pavement of hardstanding in bays between joints & contraction, expantion joints or between the two contraction jointscomplete all as specified and directed. |
| 12 | Finishing surface of concrete, by brooming, complete all as specified and directed. |
| 13 | Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ of thickness of concrete slab in 150 mm, complete all as specified and directed. |
| 14 | Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade A, complete all as specified and directed. |
| 15 | Dismantling stone slab floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish offpremises etccomplete all as specified and directed. |
| 16 | M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over and including 20mm thick screed bed or bedding layer in CM(1:6) complete all as specified and directed. |
| 17 | M&L Granite (of any type) tiles 20mm thick machine cut, in skirting bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over and including 15 mm thick backing coat in CM(1:3) complete all as specified and directed. |
| 18 | Cleaning of drain of deposited soil by excavation in trenches not exc 1.5mtr wide and n.exc. 1.50m deep as indrain n.exc. 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed. |
| 19 | Removing excavated material n. exc. 50 mof soil, complete all as specified and directed. |
| 20 | Demolition bricks (laid flat or on edge) or brick tiles laid bedded and pointed in any mortar as in floors, channels, kerbs, aprons, etc. (each layer) complete all as specified and directed. |
| 21 | M&L for bricks, sub class B, laid flat, in floors, old size bricks laid bedded and jointed in cement mortar in 1:6 and pointed in CM 1:3 complete all as specified and directed. |
| 22 | M&L for bricks, sub class B, laid on edge, in floors, old size bricks laid bedded and jointed in cement mortar in 1:6 and pointed in CM 1:3 complete all as specified and directed. |
| 23 | Taking down cement plaster on brick/stone surface of wall built in cement mortar including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 24 | M&L for rendering 15 mm thick on fair face of brick walls or concrete surface in CM 1:4 complete finished even and smooth without using extra cement complete all as specified and directed. |
| 25 | M&L preparation of new surface and applying two coats of cement based paint over a coat of primer complete all as specified and directed. |
| 26 | M&L for preparation of old surface and applying two coats of cement based paint complete all as specified and directed. |
| 27 | M&L for preparation of walls and applying one coat of 100% premium acrylic emulsion paint having VOC less than 25gm/ltr and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon aditives at 1.43 ltr/20sqm complete all as specified and directed. |
| 28 | Returning & filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 CM thick in soft/ loose soil, complete all as specified and directed. |
| 29 | M&L for sand cushioning (dry sand) to under ground cable for cable protection with layer of 8 cm deep before laying the cable and 15 cm depth after laying the cable, complete all as specified. Note: Punned thickness of sand layers shall be measured and paid contractor. |
| 30 | Supply and laying bricks for protection of cables using sub class \"B\" bricks laid dry flat across length of the cable with width equal to the length of brics complete all as specified and directed. |
| 31 | Supply and Laying in trenches / fixed to wall/ drawn in pipe/ duct/laid in floor XLPE insulated screened, PVC bedded and sheathed and steel wire/strip armoured cable 1100V grade with stranded aluminum conductor of cross sectional area 10 Sqmm 2 core complete all as specified and directed. |
| 32 | Supply and fixing new generation energy saving & environmental friendly long life LED flood light 100 watt 230 V AC outdoor type with high pressure die cast aluminium housing with toughened glass and heat resistant and individual high power LED\"s, high efficiency >120 lm/W with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including making electric connection with three core copper cable with all accessories complete all as specified and directed. |
| 33 | S&F LT cable junction box dust and whether proof made out of PVC non metallic sheet FRP type, factory made out of PVC non metalic sheet FRP type, factory made, size of box 250mm x 200 mm x 100 mm deep with swivelling cover and locking clamp, MS clamps and nuts, bolts, for fixing the box, consisting of aluminium bus bar strip 150mm x 30 mm x 3 mm - 04 nos and provision of incoming and outgoing PVC insulated cable with grommets including inbuilt 6 Amp MCBSP 10 KA-01 No complete all as specified and directed. |
| 34 | M&L for boring of holes under road, pavement, hard standing, boring manually or by machine for insertion of GIpipe of size upto 40 mm dia suitable complete all as specified and directed. |
| 35 | S&F GI pipe 40 mm light grade with all fitting fixed to electric pole and laid in road crossing/along the pole for cable protection with suitable size clamp, nut bolt and washers all as directed. |