}

Tender For Repair Maintenance For Amc Of Transformers, Generator,Pumping Sets, Motors,Irp, Ro Plants, Air Conditioners And Other Em Installation And Equipement For Hq 6 Sector Arand Under Comd Units., Wokha-Nagaland

Assam Rifles has published Tender For Repair Maintenance For Amc Of Transformers, Generator,Pumping Sets, Motors,Irp, Ro Plants, Air Conditioners And Other Em Installation And Equipement For Hq 6 Sector Arand Under Comd Units.. Submission Date for this Tender is 01-09-2025. Transformer Repair Tenders in Wokha Nagaland. Bidders can get complete Tender details and download the document.




Tender Notice

50725077
Tender For Repair Maintenance For Amc Of Transformers, Generator,Pumping Sets, Motors,Irp, Ro Plants, Air Conditioners And Other Em Installation And Equipement For Hq 6 Sector Arand Under Comd Units.
Tender
Indian
Nagaland
Wokha
01-09-2025

Tender Details

Tender For Repair Maintenance For Amc Of Transformers, Generator,Pumping Sets, Motors,Irp, Ro Plants, Air Conditioners And Other Em Installation And Equipement For Hq 6 Sector Arand Under Comd Units.; 1 TRANSFORMER REPAIR AND LT LINE WORK 2 Taking out the sample of transformer oil from each transformer at various locations for checking the dielectric strength and acidity test of oil for the presence of moist presence of moisture, impurities etc afterthe dehydration including de-hydration (Filtration) of transformer oil through mobile filtration plant to be usedto respective locations duly connecting inlet/outlet to the machine by switching off HT power supply and taking all safety precautions so as to achieve dielectric strength not less 36 to 40 KV per minute rupturing capacity and switch on supply, charging of transformer all as directed for transformer . The item inclusive ofTransportation ofmobile filtrationupto work siteandtesting will becarried outafter dehydration and exclusive ofoil topping. Oil topping ofrequiredquantitywillbe paid spearately on measurements as per schedulethis work. 3 Replacement ofbushing insulator (male and female with gasket ) complete set as per samplefor 200/250 KVAtransformer 4 Replacement ofbushing insulator (male and female with gasket ) complete set as per samplefor 500 KVA transformer 5 Removing the existing oil stains by point removers and cleaning with scrapers, preparing the oldtransformerssurfacesincluding subsequent coat ofsynthetic enamelpaint of approved colour with one coatof red oxide zinchrome primer ofthe surface of the transformer of capacity200 KVAby spray gun all as specified and directed at site. 6 Removing the existing oil stains by point removers and cleaning with scrapers, preparing the oldtransformerssurfacesincluding subsequent coat ofsynthetic enamelpaint of approved colour with one coatof red oxide zinchrome primer ofthe surface of the transformer of capacity500 KVAby spray gun all as specified and directed at site. 7 Taking down old UNSV gasket by removing notbolt systemfrom main body of the transformer including replacment of entire gasket completeof cpacity upto 500 KVA all asall as psecified and directed at site. 8 Supply and fix LT OH lines onexisting Steel /PCC poles with Continuous GI earth wire incl earthing of poles cross arms, insulators etcsize 3 of 6/1 x 2.59 mm (Weasel),1 of 6/1 x 2.11mm (Squirrel) (Sect HQ Camp area) 9 Dismantling, Taking down carefully from the installed position and re installing in its original position and testing on completion of proper servicing complete all as directed by the Engineer – in – Charge of1.5 Ton capacity Split type AC. 10 Dismantling, Taking down carefully from the installed position and re installing in its original position and testing on completion of proper servicing complete all as directed by the Engineer – in – Charge of2 Ton capacity Split type AC. 11 M & L for Gas refilling and charging of R-22 refrigerant tothe 1.50Ton capacity Split type AC,including testing of leak the complete system as specified and as per direction of Engineer - in - Charge. 12 M & L for Gas refilling and charging of R- 32 refrigerant tothe 1.5 ton capacity Split Type AC, including testing of leak the complete system as specified and as per direction of Engineer - in - Charge. 13 M & L for Gas refilling and charging of R-32 refrigerant tothe 1.5Ton capacity Window Type AC,including testing of leak the complete system as specified and as per direction of Engineer - in - Charge. 14 M & L for Gas refilling and charging of R- 32 refrigerant tothe 2 ton capacity Split Type AC, including testing of leak the complete system as specified and as per direction of Engineer - in - Charge. 15 Servicing only Split type air conditionersof 1.5/2.00 Ton capacity by cleaning of out door/indoor units,Removal of dust, dirtand debris from filters,coils and fins, Checkingand cleaning of drainage pipes.,Checking of thermostat functionalityand checking of refrigrant pressure levelsetc complete. 16 Disconnect and remove unserviceable main PCB/display PCB and Supply and fixing New main PCB/display PCB suitable for existing modelfor 1.5Ton capacity Split type AC (Display PCB) AC complete all as specified and as per direction of Engineer – in – Charge. 17 Disconnect and remove unserviceable main PCB/display PCB and Supply and fixing New main PCB/display PCB suitable for existing modelfor 1.5Ton capacity Split type AC (Inverter type) AC complete all as specified and as per direction of Engineer – in – Charge. 18 Disconnect and remove unserviceable main PCB/display PCB and Supply and fixing New main PCB/display PCB suitable for existing modelfor 2 Ton capacity Split type AC (Display PCB) AC complete all as specified and as per direction of Engineer – in – Charge. 19 Disconnect and remove unserviceable main PCB/display PCB and Supply and fixing New main PCB/display PCB suitable for existing modelfor 2Ton capacity Split type AC (Inverter type) AC complete all as specified and as per direction of Engineer – in – Charge. 20 Disconnect and remove unserviceable main PCB/display PCB and Supply and fixing New main PCB/display PCB suitable for existing modelfor 1.5 Ton capacity Window Type AC (Display PCB) AC complete all as specified and as per direction of Engineer – in – Charge. 21 Disconnect and repair of main PCB/display PCB and re fixing of repaired main PCB/display PCB suitable for 1.5Ton capacity Split type AC (Display PCB)complete all as specified and as per direction of Engineer – in – Charge 22 Disconnect and repair of main PCB/display PCB and re fixing of repaired main PCB/display PCB suitable for 2Ton capacity Split type AC (Display PCB)complete all as specified and as per direction of Engineer – in – Charge 23 Disconnect and repair of main PCB/display PCB and re fixing of repaired main PCB/display PCB suitable for 1.5Ton capacity Window Type AC (Display PCB)complete all as specified and as per direction of Engineer – in – Charge 24 Installation only Air conidtioner unit of 1.5/2 Ton cacpaicty includes mou nting of indoor unit,installation of out door unit, refrigerant piping and insulation, drain line work and commissioning and testing of entire unit complete.The cost inclusive of 4 mtr copper pipe of 1/2,3/4 size complete. 25 Taking out the burnt fan motor from the 1.50Ton capacity Split type AC and supply and fixing new fan motor suitable for existing model complete all as specified and as per direction of Engineer – in – Charge 26 Taking out the burnt fan motor from the 2Ton capacity Split type AC and supply and fixing new fan motor suitable for existing model complete all as specified and as per direction of Engineer – in – Charge 27 Taking out the burnt fan motor from the 1.50Ton capacity Window Type AC and supply and fixing new fan motor suitable for existing model complete all as specified and as per direction of Engineer – in – Charge 28 Taking down unserviceable blower motor (for Indoor unit) of 1.50Ton capacity Split type AC and supply and fixing new blower motor suitable for existing model of indoor unit of split type AC, including necessary connections and testing on completion complete all as specified and as per direction of Engineer – in – Charge. 29 Taking down unserviceable blower motor (for Indoor unit) of 2Ton capacity Split type AC and supply and fixing new blower motor suitable for existing model of indoor unit of split type AC, including necessary connections and testing on completion complete all as specified and as per direction of Engineer – in – Charge. 30 Taking down unserviceable swing motor of 1.5 ton/2 ton capacities split type AC and supply and fixing new swing motor suitable for existing model of indoor unit of split type AC including necessary connections and testing on completion complete all as specified and as per direction of Engineer – in – Charge. 31 Taking down unserviceable capacitor from Split type/Window type AC and supply and fixing New Capacitor (50/55 MFD) , including testing on completion etc complete all as specified and as per direction of Engineer – in – Charge. 32 Taking down unserviceable capacitor from Split type/Window type AC and supply and fixing New Capacitor (60 MFD) , including testing on completion etc complete all as specified and as per direction of Engineer – in – Charge. 33 Disconnect and remove unserviceable 1.50Ton capacity Split type AC compressor and Supply and fixing of new rotary/reciprocating compressor including brazing the suction/discharge lines suitable for existing model following capacity ACs and testing on all as specified and as per direction of Engineer – in – Charge 34 Supply and fixing on Wall MS factory made pre painted bracket for Out door Unit fixed with Nut bolt/ Screw. 35 Supply and fixing of copper gas pipe ½” nominal bore 36 Supply and fixing of copper liquid pipe ¼ ” nominal bore 37 Providing and fixing of PVC fliexble pipe with connected accessories of 15 mm dia /as per site requirement for external 38 Supply and fix Aflex-Eco Nitrile rubber pipes forinsulation of AC copper pipe for insulation ( dia 6/9/13/19/25 mm) with approved thickness all as per site requirement 39 Servicing/overhauling monoblock pump set of capacity 3HP, 3 Phase, 2880 RPM including carrying outmaintenance check along with following repairs: (a) Dismantling of monoblock motor pump set and display all the parts without Servicing/overhauling monoblock pump set of capacity 3HP, 3 phase , 2880 RPM including carrying outmaintenance check along with following repairs: (a) Dismantling of monoblock motor pump set and display all the parts without damage any portion for inspection of Engineer in Charge to ascertain the serviceability of existing parts. (b) Repair/ replacement of bearing and greasing. (c) Repairs play of impeller and greasing. (d) Assembling motor with old serviceable parts and replacement of unserviceable parts with new as ordered where necessary. (e) Installation of motor by making connection as per existing and testing on load. 40 ditto but 5 HP capacity (Sect HQ) 41 ditto but 10 HP capacity (Sect HQ) 42 Rewinding, Heat Varnishing, Installation, Testing and Commissioning of Centrifugal monoblock motorpump set of capacity 3 HP, working on 3 Phase, 440 volts with bare copper winding of appropriate gauge and as per direction of engineer-in- charge. (Sect HQ) 43 Rewinding, Heat Varnishing, Installation, Testing and Commissioning of Centrifugal monoblock motorpump set of capacity 5 HP, working on 3 Phase, 440 volts with bare copper winding of appropriate gauge and as per direction of engineer-in- charge. (Sect HQ) 44 Rewinding, Heat Varnishing, Installation, Testing and Commissioning of Centrifugal monoblock motorpump set of capacity 10 HP, working on 3 Phase, 440 volts with bare copper winding of appropriate gauge and as per direction of engineer-in- charge. (Sect HQ) 45 Rewinding, Heat Varnishing, Installation, Testing and Commissioning of Centrifugal monoblock motorpump set of capacity 20 HP, working on 3 Phase, 440 volts with bare copper winding of appropriate gauge and as per direction of engineer-in- charge. (Sect HQ) 46 Supply and fixing in replacement motor starter 415V, 50Hz ,phase suitable for motor capacity 5HP relay range 6-10 amps having essential motor protection against over loding single phasing phase sequence reversalabnormality in supply unbalanced current complete all as specified and direct MAKE:- L&T cat no MU-GDOL or equivalent in Simens havells. 47 M & L for opening the existingIron Vessels ofIron Remover Plant 3000 LPH ( Size- 24 dia x 60 height ) including replacement of existing old Catalytic Oxidizing filter media of various sizes including Anthracite and treated filter sand , unserviceable strainers etc complete and deposited to place where directedby Engineer - in - Charge :- (a)Supply and fixing rubber gasket joint for all packing required places of IRP unit- 01 Job (b) External synthetic enamel pinting etc complete. (Sect HQ, Kashiram Basti) 48 M & L for opening the existingIron Vessels ofIron Remover Plant 5000 GPHincluding replacement of existing old Catalytic Oxidizing filter media of various sizes including Anthracite and treated filter sand , unserviceable strainers etc complete and deposited to place where directedby Engineer - in - Charge :- (a)Supply and fixing rubber gasket joint for all packing required places of IRP unit- 01 Job (b)Supply and fixing diaphragm valves of size 80 mm dia -04 Nos (c) Supply and fixing water pressure gaugeduly calibrated of existing size complete 01 Joball as specified and directed. (d) External synthetic enamel pinting etc complete. (d) Replacment of plastic push type strainers of approved qulaityand size whereever required. (e) Replacment of existing MNO2 lumps or antracite lumps foroxidising agentsfor existing oxidation chamber (f) Internal vessels painted with food grade paint. 49 Replacement of 4040 membranes for 500 LPH RO plant including cleaning and minor repair of CPVC pipe line etc complete. 50 Servicing of 1000 LPH RO plant including replacement of 20 Big Blue Cartridge. 51 Replacement of 8040membranes for 1000 LPH RO plant including cleaning and minor repair of CPVC pipe line etc complete. 52 Supply and fill on replacment of carbo fillfor 1000 LPH RO plant (for acivated carbon filter). Granular activated carbon(CAG) with Iodine member of 900mg/gall as per site requirement and as per direction of Engr-In-Charge. 53 Supply and fill on replacment of carbo fillfor 500 LPH RO plant (for acivated carbon filter). Granular activated carbon(CAG) with Iodine member of 900mg/gall as per site requirement and as per direction of Engr-In-Charge. 54 Supply and filling antiscalent ofapproved quality. 55 Servicing of RO Plant including cleaning and maintenance of RO membrane, Roto meters, Filter catridges complete all as specified as per site requirement complete. 56 Supply and fixing offan capacitor of 2.5 MFD capacity (Make: EPCOS/Havells/Concap) 57 Supply and fixing 2 core copper flexible wires of size 7/20 ofapproved quality(Sect HQ) 58 Supply andPVC Casing caping of 25 mm diaincluding replacment of existingPVC condutis of wiring complete 59 Supplying and fixing call bell/ buzzer/Ding Dong/ Required musical soudssuitable for single phase, 230 V, complete as required. 60 Supplying and fixing 25 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A C curve, SP, MCB, in sheet steel enclosure or motor starter, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required for AC connections complete. 61 Servicing only30/35 KVADG set complete including replacement of Fuel filter element -01 Nos, Oil Filter element -01 Nos, Air filter element -01 Nos, Coolant- 05 Ltrs , Engine oil- 12 ltrs and Engine tapet servicesincluding Banjo washers etc complete as per site requierment. 62 Servicing only 62.5KVADG set complete including replacement of Fuel filter element -01 Nos, Oil Filter element -01 Nos, Air filter element -01 Nos, Coolant- 05 Ltrs , Engine oil- 12 ltrs and Engine tapet servicesincluding Banjo washers etc complete as per site requierment. 63 Servicing only 125KVADG set complete including replacement of Fuel filter element -01 Nos, Oil Filter element -01 Nos, Air filter element -01 Nos, Coolant- 05 Ltrs , Engine oil- 12 ltrs and Engine tapet servicesincluding Banjo washers etc complete as per site requierment. 64 Supply, Installation Testing and Commissioning of 30 HP centrifugalpumping set on existing foundation 3 phase, with Suction and delivery size 100mm x80mm with discharge capacity of 20 LPS on60 Mtr Head with provding 30 HP capcitywith necessary connectionby using 16 Sqmm Copper conductor cable and testing all as per ground requirement/ as per direction of Engr-In- Charge.The cost inclusive of one year warrnaty maintenance excluding spares. 65 Supply and fixing automaitc change over switch63 Amps, 240 Volts ac suitable to mount on existing circuit including necessary connection and teting allas specified and directed at site. 66 Material & Labour for overhauling of 35 KVAGenr set(Canopy Type) Model No.4575M, Engine Ser No.V4H10T2970, of Make- Mahindraby taking out all unserviceable spares parts, cleaning by brushing to remove dust including replancing of diesel filters, lub oil filters, checking of all nuts, bolts tightening wherever necy, draining out old engine oil and coolant and filing new engine oil and coolants required at site. Adjustment and replacement of fan belt, tuning of engine, adjustment of speed, alternator voltage, frequecny etc , greasing, oiling and checking for smooth running of DG set including following spare parts. Cost of dismantling work and Site Inspection charges including the scope of work:- 67 (a) Head Gasket 68 (b) Chamber Gasket 69 (c)Tapet Gasket 70 (d) Valve Oil Seal 71 (e) Engine Oil 72 (f)Coolant 73 (g)Valve Intake 74 (h)Valve exhaust 75 (j) Valve seat andIntake & Exhaust 76 (k) Vlave Guide 77 (l)Piston 78 (m) Piston Pin 79 (n)Piston Ring 80 (o) Liner 81 (p) Liner O Ring 82 (r)CR Bearing 83 (t)Thermostat 84 (u)Dyanamo Belt 85 (w) Fan Belt 86 (x) Temparature Switch 87 (y)Hose pipe 88 (z)Oil filter 89 (aa) Air filter 90 (ab) Fuel filter 91 (af)Radiatorservicing 92 (ag) Water pump assembly 93 (ac) Cylinder head seat fitting, cutting & valve guide setting 94 (ad) Nozzle pump repairing work 95 (ae) Head repairing work 96 (af) FIP Nozzle testing & servicing 97 Material & Labour for overhauling of 30 KVA Genr set Model No. HA 494 T, Engine. Ser No. 04.2121/0920036 Make- KOEL by taking out all unserviceable spares parts, cleaning by brushing to remove dust including replancing of diesel filters, lub oil filters, checking of all nuts, bolts tightening wherever necy, draining out old engine oil and coolant and filing new engine oil and coolants required at site. Adjustment and replacement of fan belt, tuning of engine, adjustment of speed, alternator voltage, frequecny etc , greasing, oiling and checking for smooth running of DG set including following spare parts. 98 (a) Valve 99 (b) Valve Guard 100 (c) Valve Seal 101 (d) Valve Oil Seal 102 (d) Linear 103 (e) Piston 104 (f) Piston ring 105 (g) Engine Oil 106 (h) Lub Oil Filter 107 (j) Main Bearing 108 (k) C.R Bearing 109 (l) Thrus Washer 110 (m) Oil Seal 111 (n) Connecting Rod 112 (o) O ring Kit 113 (p) Push rod O ring 114 (q) Oil Pump 115 (r) Head Assembly 116 (s) Head Gasket 117 (t) Connecting shaft assy 118 (u) Dynamo Ring 119 (v) FIP pump repairing & nozzle injector 120 (w) Self assembly 121 (x) Diesel filter 122 (y) Diesel pipe 123 (z) Set of joint 124 (aa) Annerbend 125 (ab) Oil cooler assembly 126 (ac) Oil cooler O Ring 127 (ad) Nozzle Guttka 128 (ae) Head lathe machine charge 129 Material & Labour for overhauling of 35 KVAGenr set(Canopy Type) Model No.4575M, Engine Ser No.V4H10T3481, of Make- Mahindra ( Genr Room , MTSect HQ)by taking out all unserviceable spares parts, cleaning by brushing to remove dust including replacing of diesel filters, lub oil filters, checking of all nuts, bolts tightening wherever necy, draining out old engine oil and coolant and filing new engine oil and coolants required at site. Adjustment and replacement of fan belt, tuning of engine, adjustment of speed, alternator voltage, frequecny etc , greasing, oiling and checking for smooth running of DG set including following spare parts. Cost of dismantling work and Site Inspection charges including the scope of work:- 130 (a) Head Gasket 131 (b) Chamber Gasket 132 (c)Tapet Gasket 133 (d) Valve Oil Seal 134 (e) Engine Oil 135 (f)Coolant 136 (g)Valve Intake 137 (h)Valve exhaust 138 (j) Valve seat andIntake & Exhaust 139 (k) Vlave Guide 140 (l)Piston 141 (m) Piston Pin 142 (n)Piston Ring 143 (o) Liner 144 (p) Liner O Ring 145 (r)CR Bearing 146 (t)Thermostat 147 (u)Dyanamo Belt 148 (w) Fan Belt 149 (x) Temparature Switch 150 (y)Hose pipe 151 (z)Oil filter 152 (aa) Air filter 153 (ab) Fuel filter 154 (af)Radiatorservicing 155 (ag) Water pump assembly 156 (ac) Cylinder head seat fitting, cutting & valve guide setting 157 (ad) Nozzle pump repairing work 158 (ae) Head repairing work 159 (af) FIP Nozzle testing & servicing 160 M/L for dismantling ofAlternator and taking into wksp for rewinding of the same by suitable gauge of copper conductor and varnishing etc including testing in various loadsall as specified including refitting of alternatorandas per site. One year warrnaty will be provided for rewinded alternator to Departmenton completion of work.The cost inclusive of rotor repair works and alignment setting complete. Dismatled UNSV copper material will be the property of contractor 161 Supply and fixing AVR Card complete for Model No.4575M, Engine Ser No.V4H10T3481, of Make- Mahindra and testing complete. 162 Supply, Insallation of 01 HP monoblock centrifugal feeder pump (Slow speed) including all connected items ie. Starter, wiring connection and dismantling of old pumping set all as per sitre requirement complete for pump house filtration system. 163 Supply, Installation and testing and commissioning of Electronic dosing system suitable for 3000 LPH IRP including 100 ltr dosing tank and connected works as per site requirement forAlum and chemical dosing complete. 164 Supply only Sodium bi carbonate 165 Supply only liquid chlorine ( 50 ltr container) 166 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge of 40 mm dia 167 Making connection of G.I/CPVC . distribution branch with G.I./CPVC main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. completeof 40 mm dia. 168 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (cost of repairworks of wall and painting works in patches including making good to the surfaces to match on the existing surfaces. 169 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, 2 way piano type switch,phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 170 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required. 171 Wiring for circuit/ sub main wiring along earth wire with the 2x6 sq mm+1x6 sq mm earth wire of FRPVC insulated copper conductor, single core cable in PVC conduit as required. 172 Wiring for circuit/ sub main wiring along earth wire with the 2x2.5 sq mm+1x2.5 sq mm earth wire of FRPVC insulated copper conductor, single core cable in PVC conduit as required. 173 Supplying and fixing following modules switch/ socket on the existing modules plate & switch box including connections but excluding modules plate etc as required. (a) 5/6 ampssocket out let 174 Supplying and fixing following modules switch/ socket on the existing modules plate & switch box including connections but excluding modules plate etc as required of15/16 amp switch 175 Supply and fixing of 5 pin15/ 16amp socket outlet 176 Supply and fixing ofTelephone socket outlet/TV Antenna 177 Supplying and fixing two modulestepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 178 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required.1 or 2 Module (75mmX75mm) 179 Supply and fixing of3 Module (100mmX75mm) 180 Supply and fixing of6 Module (200mm X75mm) 181 Supply and fixing of8 Module (125mm X125mm) 182 Supply and fixing of12 Module (200mm X 150mm) 183 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required1 or 2 Module 184 Supply and fixing of 3 Module 185 Supply and fixing of6 Module 186 Supply and fixing of8 Module 187 Supply and fixing of12 Module 188 Supply and fixing of calling bell(Ding-dong), single phase, 230 Volt AC of approved quality as per site requirement. 189 Supply and fixing of single phase motor switch for AC(25Amps) of approved brand as per site requirment (Make: Legrand/Havells) ( including necessary civil works for fixing semi concealed) 190 Supply and fixing of mirror light 12 Watt, three colour provision/ as of approvedby user (Make : Philips/ Havells) 191 Supply andfix wall bracketfitting of apporved quality with bulb and accessories complete as approved by user 192 Supply & fix exhaust fans (Slim Air PVC) AC single phase 230/ 240 V of size 300 mm sweep with louver, 193 Supply and fix Ceiling surface type Grid light of 200 mm dia with 18 watts,3000k of approved quality (Make : Philips) 194 Supplying and fixing following way prewired SP&N MCB distribution board of steel sheet for 240 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etcof 6 way SPN with2x double pole MCB63 Amps and 2x40 Amps including providing blanking palte for 2 way complete 195 Supply, Installation, testing and commissioning of LED batten of 18 watts,3000K and connections with1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required (Make: Havells/Bajaj) 196 Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required of size 35 Sqmm to 95 Sqmm Size.The specification of laying cable is confirming to IS -1255.1983 and as per direction ofEngr-In Charge. (Genr line from Genr Room to JCO Club and Main line from Main Pole to JCO line). Providng cable connection to end point by using suitable size of cable lugs all as specified and directed at site. (Sect HQ) 197 Supply, Installation, testing and commisioning of LT Cubical feeder pillar box made of 2 mm thick CRCA Sheet, horizontal and vertica busbar rated 400 Amps copper 25x10 for phase and 200 A25x5 mm for neutral , RAL - 7032 (70 micron) Partially type tested as per IEC 60439, outdoor IP-53 of size 1200 mm (H) (incl 300 mm base x 400 mm width 300 mm (D) with front cable ally and cable entry bottom/top including PCC for cement concrete all as specified and directed by E-I-C.(Sect HQ)

Key Value

Document Fees
INR 1000 /-
EMD
INR 100000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents-1 0 KB
Click here to download tender document Tender Documents-1 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail