}

Bids Are Invited For Disposable 20 Ml Syringe With Needle - Single Use. Sterile. No Leakage. Non Traumatic Plunger. Latex Free. Non Toxic. Non Pyrogenic. Bp Iso Isi Ce Standards 20 Ml , Disposable 5 Ml Syringe With Needle - Syringe With Needle 5Ml Di, Jalgaon-Maharashtra

Medical Education Department has published Bids Are Invited For Disposable 20 Ml Syringe With Needle - Single Use. Sterile. No Leakage. Non Traumatic Plunger. Latex Free. Non Toxic. Non Pyrogenic. Bp Iso Isi Ce Standards 20 Ml , Disposable 5 Ml Syringe With Needle - Syringe With Needle 5Ml Di. Submission Date for this Tender is 02-09-2025. Medicine Tenders in Jalgaon Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

50723291
Bids Are Invited For Disposable 20 Ml Syringe With Needle - Single Use. Sterile. No Leakage. Non Traumatic Plunger. Latex Free. Non Toxic. Non Pyrogenic. Bp Iso Isi Ce Standards 20 Ml , Disposable 5 Ml Syringe With Needle - Syringe With Needle 5Ml Di
Tender
Indian
Maharashtra
Jalgaon
02-09-2025

Tender Details

Bids Are Invited For Disposable 20 Ml Syringe With Needle - Single Use. Sterile. No Leakage. Non Traumatic Plunger. Latex Free. Non Toxic. Non Pyrogenic. Bp Iso Isi Ce Standards 20 Ml , Disposable 5 Ml Syringe With Needle - Syringe With Needle 5Ml Disposable , Ab. Cotton 500 Gm - Absorbent Cotton Wool I.P Packet Of 500 Gm Net , Absorbent Gause 90 X 18 - Absorbent Gauze Cloth As Per Schedule F-Ii Of Drugs And Cosmetics Act.1940 Than Of 90Cm X 18 Mtrs , Absorbent Geletin Sponge 70 X 50 X 10 - Sterile Water-Insoluble Malleable Porcine Gelatin Absorbable Sponge Intended For Hemostatic Use By Applying To A Bleeding Surface. Should Be Packed In Double Envelop Date Of Sterilization Be Noted On The Pack 7 X 5 X 1Cms , Adesive Cotton Stiking 10 X5 - Adhesive Plaster Ip Usp 10 Cm X 5 Mtrs , Airway No. 0 1 2 3 4 5 - Should Be Color-Coded For Easy Identification Smooth Soft Finish With Rounded Edges Atraumatic Reinforced Bite Block To Help Prevent Occlusion. Flange Should Be Present At Buccal End To Fixe Airway In Place Curved Portion Should Extend Backwards With The Shape Of Tongue And The Palate. , Av Fistula Needle No 16 - Should Be Ultra-Siliconized Thin Walled Sharp Needle With Beveled Back Eye For Easy Insertion And Minimize Trauma To The Patient.Should Be Soft And Kink Resistant Medical Grade Pvc Tubing Available With Color Coded Fixed Wings Flexible Butterfly Wings For Better Grip Needle With Back-Eye Non Toxic Non Pyrogenic Sterile.Needle Length - 30Cms , Bactigrass 10 X 30 - Tulle Dressing Evenly Impreganted With Ointmentcontaining Chlorhexidine Acetate P 0 5% Size 10X30 Cm , Bandage Cloth 100 Cm X 20 Mtr - Bandage Cloth As Per Schedule Fii Of Drugs And Cosmetics Act 1940 Than Of 100Cm X 20 Mtrs , Bmw Bag 33 X 36 Black - Compostable Black Garbage Bag Size 30Inch X 36Inch Thickness 70 Micron Quality Double Sealing Chlorine Free Leak Proof And Complaint With Government Of Maharashtra Notifications Of Plastics. , Bmw Bag 33 X 36 Blue - Compostable Blue Garbage Bag Size 33Inch X 36Inch Thickness 70 Micron Quality Double Sealing Chlorine Free Leak Proof And Complaint With Government Of Maharashtra Notifications Of Plastics.Compostable Blue Garbage Bag Size 33Inch X 36Inch Thickness 70 Micron Quality Double Sealing Chlorine Free Leak Proof And Complaint With Government Of Maharashtra Notifications Of Plastics. , Bmw Bag 33 X 36 Red - Compostable Red Garbage Bag Size 33Inch X 36Inch Thickness 70 Micron Quality Double Sealing Chlorine Free Leak Proof And Complaint With Government Of Maharashtra Notifications Of Plastics. , Bmw Bag 33X 36 Yellow - Compostable Yellow Garbage Bag Size 30Inch X 36Inch Thickness 70 Micron Quality Double Sealing Chlorine Free Leak Proof And Complaint With Government Of Maharashtra Notifications Of Plastics. , Caresteam Laser Films 14X17size For Caresteam Dryview 6950 Laser Imager - Caresteam Laser Films 14X17 Size For Caresteam Dryview 6950 Laser Imager , Chromic Catgut No- 1 4227 - Chromic Catgut With Silver Needle 1 2 Circle Round Body Pointed Tip 50Mm Length 100Cm Size 1 Foil , Chromic Catgut No- 2 4228 - Chromic Catgut With Needle 12 Circle Round Body 45 Mm Length 76 Cm Heavy Size 2 , Colostomy Bag - It Should Have A Flange With Hypo-Allergic Adhesive That Prevents Skin Maceration It Should Be Is Light In Weight Flexible And Come With A Belting Arrangement It Is Manufactured From Extra Soft Clinical Grade Pvc Material Should Contain 1-Pc Self-Adhesive Transparent Drainable Stoma Bag For Colostomy & Illeostomy With Clamp For Easy Closing & Opening 1-Pc Stoma Bag With Curagard Adhesive For Long Wear Time. Customised Cuting Of The Adhesive According To The Size Of The Stoma From 15-60Mm European Ce Certification With High International Standard. , Cord Clamp - Disposable Umbilical Cord Clamp Are Made From Non Toxic Medical Grade Polymer. 1. Material Pvc Pe Pp Abs Etc. 2. Sterilize By Ethylene Oxide Gas 3. Supplied Sterile In Individual Peel-Able Polybag. Or Equivalent , Cvp Central Line 7 Fr Tripal Lumen Catheter - 1 Should Be Radio-Opaque Catheter Material Made Of Polyurethane With Specially Designed Soft Tip 2 Kink Resistant Guide Wire With Soft J-Tip 3 Guidewire Should Be Made Of Nitinol Or Equivalent 4 Lcngth 15 20Cm 18G Valve Needle Having Side Port 5 Safety Connector 6 Triple-Lumen Catheter Distal 16 G Middle 18 G Proximal 18 G , Diaper Adult Medium - Disposable Adult Diaper , Dispo Cautery Pencil - Button Switch Pencil With Polytetrafluoroethylene Quoted Non Stick Electro Surgical Tip With 10 Inch 3Meter Cord Box Of 50 , Dispo. Plastic Appron - Non Boilable Light Weight Thickness Not Less Than 50 Micron Green Colour Water Proof Tapes At Neck & Waist Length Upto Knee Length-48 Inches Chest 34 Inches . Individually Packed , Dispo. Poly Drape Sheet - Drape Disposable Poly Plain Sheet 100Cm X 150Cm , Dispo. Surgical Cap - Should Be Disposable Made Of Nonwoven Fluid Resistant Non Laminated Tear Proof Material With Good Quality Elastic Fit And Of Standard Size Light Blue Co Our Preferredcertification Ce Sgs Iso13485 Sterilisation With Ethylene Oxide Should Be Possible. , Dispo. Ventilator Tubing Set Adult - Sterile Disposable High Flexible Non-Kinking Double Limb Transparent Non Toxic Tubes With 22Mm Male Connector And 15Mm Female Connector On Y Piece And 22Mm Female Connector On Both The Arms. Available With Port Elbow. Outer Diameter Paediatric 15Mm.Neonate 10Mm , Disposable 3 Ply Mask - Tie On Mask Of Non Woven Hypoallergenic 3 Ply Construction With Filter In Between Offering 99 Bacterial Filtration Efficiency Bfe At 5 Micron Capacity Standard With Elastic Strings , Disposable Plastic Gloves - Disposable Plastic Gloves Individually Packed.Made Of Medical Grade Virgin P.V.C. Not Less Than 50 Micron Thickness Non Toxic With Excellent Grip Length 7 Inch Free Size Sleeve Length 295 Mm Mid-Forearm Type Non Sterile 50 Pcs 100 Pcs Pack , Ecg Roll 215 Mm X 20 - Ecg Roll 215Mm X 20 Mtrs. , Ecg Electrode Adult - Backing Material Should Be Of Polyethylene Foam Pe White With Medical Grade Pressure Sensitive Adhesive With Conductive And Adhesive Hydrogel. Supporting Back Label Polypropylene Film Pp Should Be Transparent. The Release Liner Should Be Of Polyethylene Film Pe With One Side Siliconized. Sensor Should Be Polymer Silver Silver Chloride Ag Agcl Coated And Adapter Connector Of Stainless Steel.Solid Gel Should Provide Providing Excellent Performance And Easy Clean Up.Should Have Low Impedence. Latex Free Hypoallergenic Medical Grade Material.Should Have A Shelf Life Of 24 Months At Least At Temperatures 10-30Degrees Celcius.Should Be Disposable. Appropriate Waterproof Packing. , Et Tube No. 4 Plain - Should Be Available As A Transparent Tube With Radiopaque Line In Extra-Soft Pvc. The Distal End Of The Tube Should Be Bevelled At 37+ - 10. The Tube Should Have Clear Distance Markings A Standard Male Iso Adaptor 15 Mm To Connect The Endotracheal Tube To The Ventilator The Distal End Of The Tube Should Be Bevelled At 37+-10 4Mm Id , Et Tube No. 4.5 Plain - Should Be Available As A Transparent Tube With Radiopaque Line In Extra-Soft Pvc. The Distal End Of The Tube Should Be Bevelled At 37+ - 10. The Tube Should Have Clear Distance Markings A Standard Male Iso Adaptor 15 Mm To Connect The Endotracheal Tube To The Ventilator The Distal End Of The Tube Should Be Bevelled At 37+-10 4.5Mm Id , Et Tube No. 5 Cuffed - Should Be Transparent With Blue Radio-Opaque Line Should Have Low Pressure High Volume Cuff Reducing Risk Of Creasing On Inflation Thus Minimising Pressure On Tracheal Wall Printed Pilot Balloon Smooth Murphy Eye. Should Be Able To Verify Tube Position When Within Patient. Misting Should Be Clearly Seen To Confirm Intubation The Distal End Of The Tube Should Be Bevelled At 37+-10 5 Mm Id , Et Tube No. 5 Plain - Should Be Available As A Transparent Tube With Radiopaque Line In Extra-Soft Pvc. The Distal End Of The Tube Should Be Bevelled At 37+ - 10. The Tube Should Have Clear Distance Markings A Standard Male Iso Adaptor 15 Mm To Connect The Endotracheal Tube To The Ventilator The Distal End Of The Tube Should Be Bevelled At 37+-10 5Mm Id , Et Tube No. 5.5 Cuffed - Should Be Transparent With Blue Radio-Opaque Line Should Have Low Pressure High Volume Cuff Reducing Risk Of Creasing On Inflation Thus Minimising Pressure On Tracheal Wall Printed Pilot Balloon Smooth Murphy Eye. Should Be Able To Verify Tube Position When Within Patient Misting Should Be Clearly Seen To Confirm Intubation The Distal End Of The Tube Should Be Bevelled At 37 10 5.5 Mm Id , Et Tube No. 5.5 Plain - Should Be Available As A Transparent Tube With Radiopaque Line In Extra-Soft Pvc. The Distal End Of The Tube Should Be Bevelled At 37 10 The Tube Should Have Clear Distance Markings A Standard Male Iso Adaptor 15 Mm To Connect The Endotracheal Tube To The Ventilator The Distal End Of The Tube Should Be Bevelled At 37 10 5.5Mm Id , Et Tube No. 6 Cuffed - Should Be Transparent With Blue Radio-Opaque Line Should Have Low Pressure High Volume Cuff Reducing Risk Of Creasing On Inflation Thus Minimising Pressure On Tracheal Wall Printed Pilot Balloon Smooth Murphy Eye. Should Be Able To Verify Tube Position When Within Patient. Misting Should Be Clearly Seen To Confirm Intubation 6Mm Id , Et Tube No. 6 Plain - Should Be Available As A Transparent Tube With Radiopaque Line In Extra-Soft Pvc. The Distal End Of The Tube Should Be Bevelled Ot 37 10. Graduated Markings To Display Distance From The Tip. Well Marked To Indicate The Internal External Diameter. Nasoral Tip Suitable For Both Nasal And Oral Intubation. Full Length Radio-Opaque Lines To Assess Position Of The Tube Radiographically. Murphy S Eye Near The Tip To Circumvent Any Obstruction. Disposable Sterile Non-Pyrogenic. A Standard Male Iso Adaptor 15 Mm To Connect The Endotracheal Tube To The Ventilator The Distal End Of The Tube Should Be Bevelled At 37 10 6 Mm Id , Et Tube No. 6.5 Cuffed - Should Be Transparent With Blue Radio-Opaque Line Should Have Low Pressure High Volume Cuff Reducing Risk Of Creasing On Inflation Thus Minimising Pressure On Tracheal Wall Printed Pilot Balloon Smooth Murphy Eye. Should Be Able To Verify Tube Position When Within Patient. Misting Can Be Clearly Seen To Confirm Intubation The Distal End Of The Tube Should Be Bevelled At 37 10 6.5 Mm Id , Et Tube No.7 Cuffed - Should Be Transparent With Blue Radio-Opaque Line Should Have Low Pressure High Volume Cuff Reduces Risk Of Creasing On Inflation Thus Minimises Pressure On Tracheal Wall Printed Pilot Balloon Smooth Murphy Eye. Should Be Able To Verify Tube Position Within Patient. Misting Can Be Clearly Seen To Confirm Intubation The Distal End Of The Tube Should Be Bevelled At 37+-10 7 Mm Id , Et Tube No.7.5 Cuffed - Should Be Transparent With Blue Radio-Opaque Line Should Have Low Pressure High Volume Cuff Reduces Risk Of Creasing On Inflation Thus Minimises Pressure On Tracheal Wall Printed Pilot Balloon Smooth Murphy Eye. Should Be Able To Verify Tube Position Within Patient. Misting Can Be Clearly Seen To Intubation The Distal End Of The Tube Should Be Bevelled At 37 10 7 5 Mm Id , Et Tube No.8 Cuffed - Should Be Transparent With Blue Radio-Opaque Line Should Have Low Pressure High Volume Cuff Reducing Risk Of Creasing On Inflation Thus Minimises Pressure On Tracheal Wall Printed Pilot Balloon Smooth Murphy Eye. Should Be Able To Verify Tube Position Within Patient. Misting Can Be Clearly Seen To Confirm Intubation The Distal End Of The Tube Should Be Bevelled At 37 10 8 Mm Id , Ethilon No- 2-0 3336 1 2 Circle 40Mm Rc - Nylon Monofilament Nonabsorbable Polymers With Needle 3 8 Circle Needle Reverse Cutting 45Mm Length 100 Cm Size 2 0 , Ethilon No- 3-0 3328 1 2 Circle 40Mm Rc - Nylon Monofilament Polyamide 3 8 Circle Cutting Needle 30 Mm 70Cm Size 3 0 , Examination Gloves L Pack Of 100 - Disposable Examination Gloves Made Of Soft Latex Powder-Free Highly Elastic And Tear-Resistant Texturing Of The Finger Area Ensures Optimum Grip Excellent Fit And High Tactile Sensitivity.Astm Iso & Fda Ce 93 42 Eec Approved. Pack Of 100 , Examination Gloves M Pack Of 100 - Disposable Examination Gloves Made Of Soft Latex Powder-Free Highly Elastic And Tear-Resistant Texturing Of The Finger Area Ensures Optimum Grip Excellent Fit And High Tactile Sensitivity.Astm Iso & Fda Ce 93 42 Eec Approved. , F6 Dailyser - The Fibers Should Be Made From Such Biocompatible Materials Polysulfone. Should Have A Microporous Structure That Permit The Diffusion Of Small Molecular Weight Species From The Blood To The Dialysate. A Eff 1.3 Sq.Mtr Tmp Max.600Mmhg Uf Rate 5.5. Should Be Sterile.Shelf Life 36 Month , Foleys Cathetor No. 6 - 3-Way Foley Catheter Should Bemade Up Of Latex Bonded With Silicone Elastomer Which Eliminates The Risk Of Encrustation The Smooth Surface Of This Indwelling Catheter Should Facilitate Non-Traumatic Intubation The 3 Way Foley Catheter Should Be Provided With An Additional Irrigation Lumen The Catheter Should Have A Symmetrical Large Capacity Balloon Ensuring A Straight Tip For Proper Flow And Good Sphincter Action Thus Preventing Bladder Leakage The Catheter Should Be Provided With A Coned Distal End With Burr Free Eyes For Atraumatic Insersion The Catheters Hard Valve Should Ensure Easy Inflation And Deflation Of The Balloon. , Glucometer Strip With Glucometer - Per 1000 Strip One Machine Should Be Provided , H.D. Tubing - Should Have Soft And Kink Resistant Transparent Tubing With Guarded Access Ports To Reduce Infection Risk. Should Have Male Female Luer Lock In Compliance With International Specifications.Smooth Inner Surface To Reduce Foaming And Facilitate Removal Of Air. Latex Free For Single Use Sterile Self Life- 36 Months.European Ce & Iso Certified. Pre-Pump Type. , Hernea Kit 8 X 15 Cm - 1 Polyglactin 910 Violet Coated & Braided Size 2-0 70Cm 2. Monofilament Polyamide Nylon Black Size 3 0 70Cm 3 Monofilament Polypropylene Blue Size 2-0 90Cm 4 Monofilament Polypropylene 8X15cm Mesh , Hernia Mesh 15X15cm - Polypropelene Mesh 15Cm X 15Cm , Hernia Mesh 30X30cm - Polypropelene Mesh 30Cm X 30Cm , Disposable Hiv Kit - Each Kit Should Contain 1.Disposable Head Cap Made On Non Women Fabric- 1 Pc 2.Disposable Face Mask - 1 Pc 3.Disposable Protective P.V.C.Inner Apron Upto Knee Length Without Sleeves - 1 Pc 4.Disposable Surgical Gown With Full Sleeves & With Elastic Cuff Non Woven Breatheable Fabric Without Plastic Coating Water & Alcohol Repellent - 1 Pc 5.Disposable Rubber Hand Gloves-1 Pair Free Size 6.Disposable Non-Woven Fabric P.V.C. Shoe Cover With Length Upto Just Below Knee-1 Pair 7.Disposable Safety Goggles - 1 Pc , I.V Cannula No. 20 - Disposable Sterile Single Use Individually Transparent Packing Colour Code According To Size Should Have Injection Port Snap Lid On Port Leak Proof Must Be Leur Fitting Adaptable Fixation Wings. Material Polytetrafluoroethylene Ptfe Fep. Should Be Non Thrombogenic Non Toxic And Non Pyrogenic. The Inner Needle Must Have A Bevel For Minimal Puncture Trauma Blood Flow Through Needle Must Be Adequate To Ensure Immediate Flow Cannula Should Be A. Thin Walled B. X - Ray Contrast Line The Distal End Of The Tube Should Be Bevelled At 37+-10 C. Smooth Surface Bp Iso Isi Ce Standards 20G , I.V Cannula No. 22 - Disposable Sterile Single Use Individually Transparent Packing Colour Code According To Size Should Have Injection Port Snap Lid On Port Leak Proof Must Be Leur Fitting Adaptable Fixation Wings. Material Polytetrafluoroethylene Ptfe Fep. Should Be Non Thrombogenic Non Toxic And Non Pyrogenic. The Inner Needle Must Have A Bevel For Minimal Puncture Trauma Blood Flow Through Needle Must Be Adequate To Ensure Immediate Flow Cannula Should Be A. Thin Walled B. X - Ray Contrast Line The Distal End Of The Tube Should Be Bevelled At 37+-10 C. Smooth Surface Bp Iso Isi Ce Standards 22G , I.V Cannula No. 24 - Disposable Sterile Single Use Individually Transparent Packing Colour Code According To Size Should Have Injection Port Snap Lid On Port Leak Proof Must Be Leur Fitting Adaptable Fixation Wings. Material Polytetrafluoroethylene Ptfe Fep Should Be Non Thrombogenic Non Toxic And Non Pyrogenic. The Inner Needle Must Have A Bevel For Minimal Puncture Trauma Blood Flow Through Needle Must Be Adequate To Ensure Immediate Flow Cannula Should Be A. Thin Walled B. X - Ray Contrast Line The Distal End Of The Tube Should Be Bevelled At 37 10 C. Smooth Surface Bp Iso Isi Ce Standards 24G , Infant Feeding Tube No. 5 50 Cm - For Neonatal And Paediatric Nutritional Feeding Should Be Made Of Non Toxic Pvc Material Should Have A Closed Distal End With Two Lateral Eyes Tube With Radio-Opaque Line Marked At 50 Cms From The Tip For Accurate Placement Soft And Rounded Tip To Prevent Trauma During Application Soft Frosted And Kink Resistant Pvc Tubing Radio Opaque Line Is Provided Throughout The Length For X-Ray Visualisation Proximal End Is Fitted With Female Luer Mount For Easy Connection To Feeding Funnel Or Syringe Colour Coded For Size Identification Also Available With Luer Lock Sterile Product For Single Use , Infant Feeding Tube No. 6 50 Cm - For Neonatal And Paediatric Nutritional Feeding Should Be Made Of Non Toxic Pvc Material Should Have A Closed Distal End With Two Lateral Eyes Tube With Radio-Opaque Line Marked At 50 Cms From The Tip For Accurate Placement Soft And Rounded Tip To Prevent Trauma During Application Soft Frosted And Kink Resistant Pvc Tubing Radio Opaque Line Is Provided Throughout The Length For X-Ray Visualisation Proximal End Is Fitted With Female Luer Mount For Easy Connection To Feeding Funnel Or Syringe Colour Coded For Size Identification Also Available With Luer Lock Sterile Product For Single Use , Infant Feeding Tube No. 8 50 Cm - For Neonatal And Paediatric Nutritional Feeding Should Be Made Of Non Toxic Pvc Material Should Have A Closed Distal End With Two Lateral Eyes Tube With Radio-Opaque Line Marked At 50 Cms From The Tip For Accurate Placement Soft And Rounded Tip To Prevent Trauma During Application Soft Frosted And Kink Resistant Pvc Tubing Radio Opaque Line Is Provided Throughout The Length For X-Ray Visualisation Proximal End Is Fitted With Female Luer Mount For Easy Connection To Feeding Funnel Or Syringe Colour Coded For Size Identification Also Available With Luer Lock Sterile Product For Single Use , Infant Feeding Tube No. 10 50 Cm - For Neonatal And Paediatric Nutritional Feeding Should Be Made Of Non Toxic Pvc Material Should Have A Closed Distal End With Two Lateral Eyes Tube With Radio-Opaque Line Marked At 50 Cms From The Tip For Accurate Placement Soft And Rounded Tip To Prevent Trauma During Application Soft Frosted And Kink Resistant Pvc Tubing Radio Opaque Line Is Provided Throughout The Length For X-Ray Visualisation Proximal End Is Fitted With Female Luer Mount For Easy Connection To Feeding Funnel Or Syringe Colour Coded For Size Identification Also Available With Luer Lock Sterile Product For Single Use , Intrcoastral Drainage Trocar N0- 20 - Size 20 Length Of Catheter-350Mm Catheter Should Be Provided With Trocar For Easy Penetration And Flat Handle Of A Trocar Catheter For Easy Maneuverability And Controlled Insertion. Catheter Should Be Kink-Resistant Smooth Finish Pvc With Streamline Radio-Opaque Line Flat Handle To Facilitate Easy Maneuverability Markings Provided At 5 10 15 And 20 Cm From The Distal Tip To Help Ascertain The Depth Of Penetration.Thermosensitive Material Used In These Equipments Softens With Body Temperature.Safety Stop In Cannula With Tip-To-Toe Radiopaque Strip. , Intrcoastral Drainage Trocar N0- 24 - Size 24 Length Of Catheter-350Mm Catheter Should Be Provided With Trocar For Easy Penetration And Flat Handle Of A Trocar Catheter For Easy Maneuverability And Controlled Insertion. Catheter Should Be Kink-Resistant Smooth Finish Pvc With Streamline Radio-Opaque Line Flat Handle To Facilitate Easy Maneuverability Markings Provided At 5 10 15 And 20 Cm From The Distal Tip To Help Ascertain The Depth Of Penetration.Thermosensitive Material Used In These Equipments Softens With Body Temperature.Safety Stop In Cannula With Tip-To-Toe Radiopaque Strip. , Intrcoastral Drainage Trocar N0- 28 - Size 28 Length Of Catheter-350Mm Catheter Should Be Provided With Trocar For Easy Penetration And Flat Handle Of A Trocar Catheter For Easy Maneuverability And Controlled Insertion. Catheter Should Be Kink-Resistant Smooth Finish Pvc With Streamline Radio-Opaque Line Flat Handle To Facilitate Easy Maneuverability Markings Provided At 5 10 15 And 20 Cm From The Distal Tip To Help Ascertain The Depth Of Penetration.Thermosensitive Material Used In These Equipments Softens With Body Temperature.Safety Stop In Cannula With Tip-To-Toe Radiopaque Strip. , Intrcoastral Drainage Trocar N0- 32 - Size 32 Length Of Catheter-350Mm Catheter Should Be Provided With Trocar For Easy Penetration And Flat Handle Of A Trocar Catheter For Easy Maneuverability And Controlled Insertion. Catheter Should Be Kink-Resistant Smooth Finish Pvc With Streamline Radio-Opaque Line Flat Handle To Facilitate Easy Maneuverability Markings Provided At 5 10 15 And 20 Cm From The Distal Tip To Help Ascertain The Depth Of Penetration.Thermosensitive Material Used In These Equipments Softens With Body Temperature.Safety Stop In Cannula With Tip-To-Toe Radiopaque Strip. , Jr Circuit Paed Bain Circuit Pead - It Should Be Corrugated Flexible Lightweight And Transparent For Easy Monitoring Of Water Build Up Or Blockages.Should Be Provided With 10 And 15 Mm Corrugated Tube Expiratory Valve And 0.5 Litre Antistatic Bag.The Inner Tubing Should Be Non Kinkable And Non Crackable. , Makintosh Rubber 110 Cm - Should Be Made Of Rubber With Double Colour High Grade Polymer 55 Grade A Should Be Resistant To High Temperature Chemical Resistance And Fair Abrasion Resistance.Should Be Water Proof. Colour Green Blue Red Thickness 0 4Mm Width 110Cm Roll Of 30 Metres I.S.O.Certified Isi Mark 4135 1974 , Monocryl 2-0 1 2 Circle - Poliglecaprone 25-Dyed 1 2 Circle R.B 30Mm 70Cm Size 2 0 , Monocryl 3-0 1 2 Circle - Poliglecaprone 25-Undyed Curved Reverse Cutting 26Mm 70Cm Size 3 0 , Multi Directional Skin Stapler Stp-007 - Multidirectional Skin Stapler With 35 Wide Staples Having Alignment Indicator Ergonomic Pistol-Grip Handle Design Comfortable For Smaller Hands , Nebuliser Mask Adult - Mask Nebulizer Adult , Nebuliser Mask Paed. - Mask Nebulizer Pead , Oxygen Mask Paeditic - Should Cover The Nose And Mouth Manufactured From Soft Non Toxic Medical Grade Pvc Compound Should Be Transparent Odour Free And Lightweight Should Have An Elastic Strap And Aluminum Nose Clip Is Provided On The Mask For Proper Adjustment Of Mask On Nasal Area Should Have Multichannel Tube Ensure Regular Supply Of Oxygen If Tube Is Accidently Kinked. The Tube Should Be Provided With Connecters At Both Ends For Easy Connection With Oxygen Source.Tube Length-210Cm. Ce Marked Packed In One Palstic Bag With Label Containing Product Name .Mfg.Date Exp.Date Mfg.By. , Paper Stiking 1 2 X 5 Mtr. - Adhesive Tape Paper Based Non-Allergic Microscopically Porous. Ip Usp Bp. Size 1 2 Inch X 5 Mtrs. , Plaster Of Paris Bandage 10 Cm X 4 Mtrs. - Plaster Of Paris Bandage B.P Readymade Size 10 Cm X 4 Mtrs , Plaster Of Paris Bandage 15 Cm X 4 Mtrs. - Plaster Of Paris Bandages Ready Made Size 15 Cm X 4 M , Plaster Of Paris Bandage 7.5 Cm X 5 Mtrs. - Adhesive Plaster Ip Usp 7.5 Cm X 5 Mtrs , Rolled Bandage 15 Cm X 4 Mtrs. - Rolled Bandage As Per Schedule Fii Of Drugs And Cosmetics Act 1940 Size 15 Cm X 4 Mtrs. , Romovac Drain Set No. 10 - Disposable Negative Suction Drain Set Comprising Bellow Unit With Connector. Connecting Tube With Clamp And Y Connector. Curved Needle With Matching Catheter. Spare Perforated Catheter. No.10G , Romovac Drain Set No. 12 - Disposable Negative Suction Drain Set Comprising Bellow Unit With Connector. Connecting Tube With Clamp And Y Connector. Curved Needle With Matching Catheter. Spare Perforated Catheter. No.12G , Romovac Drain Set No. 14 - Disposable Negative Suction Drain Set Comprising Bellow Unit With Connector. Connecting Tube With Clamp And Y Connector. Curved Needle With Matching Catheter. Spare Perforated Catheter. No.14G , Romovac Drain Set No. 16 - Disposable Negative Suction Drain Set Comprising Bellow Unit With Connector. Connecting Tube With Clamp And Y Connector. Curved Needle With Matching Catheter. Spare Perforated Catheter. No.16G , Ryles Tube No. 14 - Should Be Soft & Kink Resistance Tube With Extra Opaque Stripe. Should Be Prepared From Approved Medical Grade Polyvinylchloride. Closed Distal End With Metallic S.S. Balls Sealed Into The Tube To Assist The Easy Passage Of Tube During Insertion. Should Have Four Lateral Eyes Length 105Cm Tube With Extra Opaque Line Is Marked At 45 55 65 And 75Cm. Used For Nasogastric Introduction For Nutrition And Aspiration Of Intestinal Secretion 14 Fr , Ryles Tube No. 16 - Should Be Soft & Kink Resistance Tube With Extra Opaque Stripe. Should Be Prepared From Approved Medical Grade Polyvinylchloride. Closed Distal End With Metallic S.S. Balls Sealed Into The Tube To Assist The Easy Passage Of Tube During Insertion. Should Have Four Lateral Eyes Length 105Cm Tube With Extra Opaque Line Is Marked At 45 55 65 And 75Cm. Used For Nasogastric Introduction For Nutrition And Aspiration Of Intestinal Secretion 16 Fr , Sterile Surgical Gloves No.6.5 - Sterile Disposable Surgical Gloves Powder Free Isi Mark 13422 1992 Iso. , Sterile Surgical Gloves No.7 - Sterile Disposable Surgical Gloves Powder Free Isi Mark 13422 1992 Iso , Sterile Surgical Gloves No.7.5 - Sterile Disposable Surgical Gloves Powder Free Isi Mark 13422 1992 Iso & Fda Ce Approved. , Suction Catheter No. 8 - Should Be Sterile Distal End Open With One Lateral Eye. Thumb Control At Proximal End Pvc Material Non Toxic Non Pyrogenic Colour Coded For Size Identification Plain Funnel Shape Connector Soft Distal End. Length 40-57Cm. Size Fg Bp Iso Isi Ce Standards 8 Fg , Surgical Blade No. 24 1 X 100 - Surgical Blade B.P. Blade Pre Sterile Wrapped With Antirust Paper In Aluminium Foil I S I Mark No. 24 Surgical Blades Pre-Sterile With Gamma Radiation For Handle No. 4 Size Ce Certificied , Surgical Blade No. 11 1 X 100 - Surgical Blade B.P. Blade Pre Sterile Wrapped With Antirust Paper In Aluminium Foil No. 11 Surgical Blades Pre-Sterile With Gamma Radiation Ce Certificied , Surgical Blade No. 12 1 X 100 - Surgical Blade B.P. Blade Pre Sterile Wrapped With Antirust Paper In Aluminium Foil I S I Mark No. 12 Surgical Blades Pre-Sterile With Gamma Radiation Ce Certificied , Surgical Blade No. 15 1 X 100 - Surgical Blade B.P. Blade Pre Sterile Wrapped With Antirust Paper In Aluminium Foil I S I Mark No. 15 Surgical Blades Pre-Sterile With Gamma Radiation Ce Certificied , Tracheostomy Tube Cuffed No. 3 - 1.The Tracheostomy Tube Should Be A Cuffed Tube Made Of Thermosensitive Material Which Softens At Body Temperature To Accommodate Individual Patient Anatomy 2. It Should Have A Soft Flexible Flange Which Helps In Easy Fixation 3. It Should Be Provided With A 15 Mm Connector And Can Be Rotated In 360 Degree Direction And Facilitate The Safe Connection To Breathing System From Any Direction 4. It Should Have A Radio Opaque Blue Line Allows For Clear X-Ray Visualization 5. It Should Be Supplied With Cotton Neck Tape And Is Sterile And Individually Blister Packed 6. It Should Be Light In Weight And Non Irritant Size-3 , Tracheostomy Tube Plain No. 3 - 1.The Tracheostomy Tube Should Be A Plain Tube Made Of Thermosensitive Material Which Softens At Body Temperature To Accommodate Individual Patient Anatomy 2. It Should Have A Soft Flexible Flange Which Helps In Easy Fixation 3. It Should Be Provided With A 15 Mm Connector And Can Be Rotated In 360 Degree Direction And Facilitate The Safe Connection To Breathing System From Any Direction 4. It Should Have A Radio Opaque Blue Line Allows For Clear X-Ray Visualization 5. It Should Be Supplied With Cotton Neck Tape And Is Sterile And Individually Blister Packed 6. It Should Be Light In Weight And Non Irritant Size-3 , Tracheostomy Tube Cuffed No. 3.5 - 1.The Tracheostomy Tube Should Be A Plain Tube Made Of Thermosensitive Material Which Softens At Body Temperature To Accommodate Individual Patient Anatomy 2. It Should Have A Soft Flexible Flange Which Helps In Easy Fixation 3. It Should Be Provided With A 15 Mm Connector And Can Be Rotated In 360 Degree Direction And Facilitate The Safe Connection To Breathing System From Any Direction 4. It Should Have A Radio Opaque Blue Line Allows For Clear X-Ray Visualization 5. It Should Be Supplied With Cotton Neck Tape And Is Sterile And Individually Blister Packed 6. It Should Be Light In Weight And Non Irritant Size-3.5 , Tracheostomy Tube Plain No. 3.5 - 1.The Tracheostomy Tube Should Be A Plain Tube Made Of Thermosensitive Material Which Softens At Body Temperature To Accommodate Individual Patient Anatomy 2. It Should Have A Soft Flexible Flange Which Helps In Easy Fixation 3. It Should Be Provided With A 15 Mm Connector And Can Be Rotated In 360 Degree Direction And Facilitate The Safe Connection To Breathing System From Any Direction 4. It Should Have A Radio Opaque Blue Line Allows For Clear X-Ray Visualization 5. It Should Be Supplied With Cotton Neck Tape And Is Sterile And Individually Blister Packed 6. It Should Be Light In Weight And Non Irritant Size-3.5 , Tracheostomy Tube Cuffed No. 4 - 1.The Tracheostomy Tube Should Be A Cuffed Tube Made Of Thermosensitive Material Which Softens At Body Temperature To Accommodate Individual Patient Anatomy 2. It Should Have A Soft Flexible Flange Which Helps In Easy Fixation 3. It Should Be Provided With A 15 Mm Connector And Can Be Rotated In 360 Degree Direction And Facilitate The Safe Connection To Breathing System From Any Direction 4. It Should Have A Radio Opaque Blue Line Allows For Clear X-Ray Visualization 5. It Should Be Supplied With Cotton Neck Tape And Is Sterile And Individually Blister Packed 6. It Should Be Light In Weight And Non Irritant Size-4 , Tracheostomy Tube Plain No. 4 - 1.The Tracheostomy Tube Should Be A Plain Tube Made Of Thermosensitive Material Which Softens At Body Temperature To Accommodate Individual Patient Anatomy 2. It Should Have A Soft Flexible Flange Which Helps In Easy Fixation 3. It Should Be Provided With A 15 Mm Connector And Can Be Rotated In 360 Degree Direction And Facilitate The Safe Connection To Breathing System From Any Direction 4. It Should Have A Radio Opaque Blue Line Allows For Clear X-Ray Visualization 5. It Should Be Supplied With Cotton Neck Tape And Is Sterile And Individually Blister Packed 6. It Should Be Light In Weight And Non Irritant Size-4 , Tracheostomy Tube Cuffed No. 4.5 - 1.The Tracheostomy Tube Should Be A Cuffed Tube Made Of Thermosensitive Material Which Softens At Body Temperature To Accommodate Individual Patient Anatomy 2. It Should Have A Soft Flexible Flange Which Helps In Easy Fixation 3. It Should Be Provided With A 15 Mm Connector And Can Be Rotated In 360 Degree Direction And Facilitate The Safe Connection To Breathing System From Any Direction 4. It Should Have A Radio Opaque Blue Line Allows For Clear X-Ray Visualization 5. It Should Be Supplied With Cotton Neck Tape And Is Sterile And Individually Blister Packed 6. It Should Be Light In Weight And Non Irritant Size-4.5 , Tracheostomy Tube Plain No. 4.5 - 1.The Tracheostomy Tube Should Be A Plain Tube Made Of Thermosensitive Material Which Softens At Body Temperature To Accommodate Individual Patient Anatomy 2. It Should Have A Soft Flexible Flange Which Helps In Easy Fixation 3. It Should Be Provided With A 15 Mm Connector And Can Be Rotated In 360 Degree Direction And Facilitate The Safe Connection To Breathing System From Any Direction 4. It Should Have A Radio Opaque Blue Line Allows For Clear X-Ray Visualization 5. It Should Be Supplied With Cotton Neck Tape And Is Sterile And Individually Blister Packed 6. It Should Be Light In Weight And Non Irritant Size-4.5 , Tracheostomy Tube Cuffed No. 5 - 1.The Tracheostomy Tube Should Be A Cuffed Tube Made Of Thermosensitive Material Which Softens At Body Temperature To Accommodate Individual Patient Anatomy 2. It Should Have A Soft Flexible Flange Which Helps In Easy Fixation 3. It Should Be Provided With A 15 Mm Connector And Can Be Rotated In 360 Degree Direction And Facilitate The Safe Connection To Breathing System From Any Direction 4. It Should Have A Radio Opaque Blue Line Allows For Clear X-Ray Visualization 5. It Should Be Supplied With Cotton Neck Tape And Is Sterile And Individually Blister Packed 6. It Should Be Light In Weight And Non Irritant Size-5 , Tracheostomy Tube Plain No. 5 - 1.The Tracheostomy Tube Should Be A Plain Tube Made Of Thermosensitive Material Which Softens At Body Temperature To Accommodate Individual Patient Anatomy 2. It Should Have A Soft Flexible Flange Which Helps In Easy Fixation 3. It Should Be Provided With A 15 Mm Connector And Can Be Rotated In 360 Degree Direction And Facilitate The Safe Connection To Breathing System From Any Direction 4. It Should Have A Radio Opaque Blue Line Allows For Clear X-Ray Visualization 5. It Should Be Supplied With Cotton Neck Tape And Is Sterile And Individually Blister Packed 6. It Should Be Light In Weight And Non Irritant Size-5 , Tracheostomy Tube Cuffed No. 5.5 - 1.The Tracheostomy Tube Should Be A Cuffed Tube Made Of Thermosensitive Material Which Softens At Body Temperature To Accommodate Individual Patient Anatomy 2. It Should Have A Soft Flexible Flange Which Helps In Easy Fixation 3. It Should Be Provided With A 15 Mm Connector And Can Be Rotated In 360 Degree Direction And Facilitate The Safe Connection To Breathing System From Any Direction 4. It Should Have A Radio Opaque Blue Line Allows For Clear X-Ray Visualization 5. It Should Be Supplied With Cotton Neck Tape And Is Sterile And Individually Blister Packed 6. It Should Be Light In Weight And Non Irritant Size-5.5 , Tracheostomy Tube Plain No. 5.5 - 1.The Tracheostomy Tube Should Be A Plain Tube Made Of Thermosensitive Material Which Softens At Body Temperature To Accommodate Individual Patient Anatomy 2. It Should Have A Soft Flexible Flange Which Helps In Easy Fixation 3. It Should Be Provided With A 15 Mm Connector And Can Be Rotated In 360 Degree Direction And Facilitate The Safe Connection To Breathing System From Any Direction 4. It Should Have A Radio Opaque Blue Line Allows For Clear X-Ray Visualization 5. It Should Be Supplied With Cotton Neck Tape And Is Sterile And Individually Blister Packed 6. It Should Be Light In Weight And Non Irritant Size-5.5 , Tracheostomy Tube Cuffed No. 6 - 1.The Tracheostomy Tube Should Be A Cuffed Tube Made Of Thermosensitive Material Which Softens At Body Temperature To Accommodate Individual Patient Anatomy 2. It Should Have A Soft Flexible Flange Which Helps In Easy Fixation 3. It Should Be Provided With A 15 Mm Connector And Can Be Rotated In 360 Degree Direction And Facilitate The Safe Connection To Breathing System From Any Direction 4. It Should Have A Radio Opaque Blue Line Allows For Clear X-Ray Visualization 5. It Should Be Supplied With Cotton Neck Tape And Is Sterile And Individually Blister Packed 6. It Should Be Light In Weight And Non Irritant 7. The Soft Low Pressure Cuff Should Dynamically Adjust The Pressure At The Point Of Contact During The Breathing Cycle. 8. It Should Have A Pilot Balloon With Non Return Valve Which Facilitates The Cuff Inflation & Deflation Size-6Mm , Tracheostomy Tube Plain No. 6 - 1. The Tracheostomy Tube Should Be A Plain Tube Made Of Thermosensitive Material Which Softens At Body Temperature To Accommodate Individual Patient Anatomy 2. It Should Have A Soft Flexible Flange Which Helps In Easy Fixation 3. It Should Be Provided With A 15 Mm Connector And Can Be Rotated In 360 Degree Direction And Facilitate The Safe Connection To Breathing System From Any Direction 4. It Should Have A Radio Opaque Blue Line Allows For Clear X-Ray Visualization 5. It Should Be Supplied With Cotton Neck Tape And Is Sterile And Individually Blister Packed 6. It Should Be Light In Weight And Non Irritant Size-6Mm , Tracheostomy Tube Cuffed No. 6.5 - 1.The Tracheostomy Tube Should Be A Cuffed Tube Made Of Thermosensitive Material Which Softens At Body Temperature To Accommodate Individual Patient Anatomy 2. It Should Have A Soft Flexible Flange Which Helps In Easy Fixation 3. It Should Be Provided With A 15 Mm Connector And Can Be Rotated In 360 Degree Direction And Facilitate The Safe Connection To Breathing System From Any Direction 4. It Should Have A Radio Opaque Blue Line Allows For Clear X-Ray Visualization 5. It Should Be Supplied With Cotton Neck Tape And Is Sterile And Individually Blister Packed 6. It Should Be Light In Weight And Non Irritant 7. The Soft Low Pressure Cuff Should Dynamically Adjust The Pressure At The Point Of Contact During The Breathing Cycle. 8. It Should Have A Pilot Balloon With Non Return Valve Which Facilitates The Cuff Inflation & Deflation Size-6.5 Mm , Tracheostomy Tube Plain No. 6.5 - 1. The Tracheostomy Tube Should Be A Plain Tube Made Of Thermosensitive Material Which Softens At Body Temperature To Accommodate Individual Patient Anatomy 2. It Should Have A Soft Flexible Flange Which Helps In Easy Fixation 3. It Should Be Provided With A 15 Mm Connector And Can Be Rotated In 360 Degree Direction And Facilitate The Safe Connection To Breathing System From Any Direction 4. It Should Have A Radio Opaque Blue Line Allows For Clear X-Ray Visualization 5. It Should Be Supplied With Cotton Neck Tape And Is Sterile And Individually Blister Packed 6. It Should Be Light In Weight And Non Irritant Size-6.5 Mm Id , Tracheostomy Tube Cuffed No. 7 - 1.The Tracheostomy Tube Should Be A Cuffed Tube Made Of Thermosensitive Material Which Softens At Body Temperature To Accommodate Individual Patient Anatomy 2. It Should Have A Soft Flexible Flange Which Helps In Easy Fixation 3. It Should Be Provided With A 15 Mm Connector And Can Be Rotated In 360 Degree Direction And Facilitate The Safe Connection To Breathing System From Any Direction 4. It Should Have A Radio Opaque Blue Line Allows For Clear X-Ray Visualization 5. It Should Be Supplied With Cotton Neck Tape And Is Sterile And Individually Blister Packed 6. It Should Be Light In Weight And Non Irritant 7. The Soft Low Pressure Cuff Should Dynamically Adjust The Pressure At The Point Of Contact During The Breathing Cycle. 8. It Should Have A Pilot Balloon With Non Return Valve Which Facilitates The Cuff Inflation & Deflation Size-7 Mm , Venous Extention Line 10 Cm - Small Bore High Pressure Low Volume Extension Tube With Male Luer Lock At One End And Female Luer Lock At Other End . Made Up Of Medical Grade P.V.C Latex Free. Bp Iso Isi Ce Standards 10Cm , Venous Extention Line 100 Cm - Small Bore High Pressure Low Volume Extension Tube With Male Luer Lock At One End And Female Luer Lock At Other End . Made Up Of Medical Grade P.V.C Latex Free. Bp Iso Isi Ce Standards 100Cm , Vicryl 2.0 2317 - Absorbable Surgical Synthetic Suture Polyglactin 910 Violet Coated & Braided 1 2 Circle Rb 30Mm 90Cm Size 2-0 , Vicryl No-1 Round Body 180 Cm 2347 - Polyglactin 910 Sterilsed Surgical Needle Suture Half Circle Round Body 40Mm Heavy 1 2 Circle Taper Cutting 40 Mm Heavy 180 Cm Size 1 , Vicryle No-1 Rev.Cutt- 40Mm Circle 90 Cm 2421 - Polyglactin-910 Braided & Coated Sterilised Surgical Needle Suture 1 2 Circle Reverse Cutting 40 Mm 90Cm Size 1 , Vicryle No-2-0 Rev.Cutt- 40Mm Circle 90 Cm 2382 - Polyglactin-910 Braided & Coated Sterilised Surgical Needle Suture 1 2 Circle Reverse Cutting 40 Mm 90Cm Size 2-0 , X-Ray Film Agfa 8 X 10 - Dry Medical Film Agfa 100 Nif 20Cmx25cm 8Inx10in , X-Ray Film Fuji 14 X 17 - Medical Dry Film 35X43 1 Packet Of 100U Sheets Each , X-Ray Film Fuji 8 X 10 - Medical Dry Imaging Film 20X25cm 8X10in 1 Packet Of 150U Sheets Each , Yankur Suction Set - The Complete Set With Tip Mounted On Two Meter Long Ribbed Tube.Universal Connector At Both The Ends .Universal Connectors Are Molded From Soft Pvc To Accommodate The Suction Tip On One End And Most Type Of Connectors Of Suction Apparatus At The Other End. Consists Of Ribbed Tube Which Is Kink Resistant And Has The Strength To Withstand The Suction , Barbour Thread No.40 - Reel Of 200 Mtrs With Individual Fillaments Of High Quality Linen With High Tensile Strength Low Tissue Reactivity Superior Knot Security & Excellent Handling Characteristics. , Barbour Thread No.60 - Reel Of 200 Mtrs With Individual Fillaments Of High Quality Linen With High Tensile Strength Low Tissue Reactivity Superior Knot Security & Excellent Handling Characteristics. , Bone Wax - Bonewax Is Composed Of Refined Beeswax With A Softening Agent And Is Supplied Sterile In Thin Sheets Structure , Bone Marrow Needle 11Fr. - Sterile Bone Marrow Needle 11G Length 100Mm Latex Free Dehp Free Non Toxic , Dispo. Insulin Syringe 40Iu - Should Have The Following Features 1.The Barrel A Plastic Chamber That Holds The Insulin Marked With Clear Lines Calibrations On The Side. 2.The Lines Show You How Many Units Of Insulin You Are Injecting. 3.The Plunger Is The Long Thin Rod That Slides Up And Down The Inside Of The Barrel. 4.A Rubber Seal At The Lower End To Prevent Insulin From Leaking Out. The Rubber Seal Fitted Such That It Matches The Line On The Barrel. 5.Sterile I.P. Individually Packed 6.Marked For 40 I.U. 1 Ml , Dispo. Needle No 21 - Single Use Sterile Surface Should Be Extremely Smooth The Needle Point Is Extremely Sharp.Color Coded Individually Blister Packed Hypodermic Needle 1 Inch , Hd Catheter Triple Lumen 12 Fr - Catheter Triple Lumen Haemodialysis 12Fr , High Flow Mask Pead. - Mask Oxygen With Reservoir Bag Paediatric , Kollagen Dressing 10X10 - Sterile Mesh Collagen Sheets In Meshed Form Preserved In Medium Containing Isopropryl Alcohol And Water Biological Skin Dressing Size 10X10 Cm , Kollagen Dressing 10X20 - Sterile Mesh Collagen Sheets In Meshed Form Preserved In Medium Containing Isopropryl Alcohol And Water Biological Skin Dressing Size 10X20 Cm , Microdrip Pead Iv Set - Intravenous Infusion Set Plastic Sterile Individually Packed In Double Plastic Bags Sterile Disposable I.P. , Nasal Prongs Adult - Disposable Latex Free Super Soft Material Tube Non Toxic Sterlized Pyrogen Free Kink-Free Crush-Resistant Tubing Long 7 Foot Tubing Non Flared Nostril Tips- Various Sizes - Adult Paed & Neonatal Ce Marked Packed In One Palstic Bag With Label Containing Product Name .Mfg.Date Exp.Date Mfg.By. , Nasal Prongs Neonatal - Disposable Latex Free Super Soft Material Tube Non Toxic Sterlized Pyrogen Free Kink-Free Crush-Resistant Tubing Long 7 Foot Tubing Non Flared Nostril Tips- Various Sizes - Adult Paed & Neonatal Ce Marked Packed In One Palstic Bag With Label Containing Product Name .Mfg.Date Exp.Date Mfg.By. , Nasal Prongs Peadiatric - Should Be Suitable For Easy And Efficient Administration Of Oxygen. Should Have Kink Resistant Main Tube To Avoid Accidental Blockage Soft Twin Prong Nasal Tips To Ensure Equal Distribution Of Oxygen Through Both Air Passages Which Provides Maximum Patient Comfort. , Nebuliser Mask With T Piece - A Rigid Plastic 15M-22M-15F T-Piece Connector For Use With Breathing System.Useful For Attaching Nebuliser To Breathing Circuit , Niv Mask Small - Made Of Silicone & Plastic Material Adopting To Different Face Sizes. Should Be Leak Proof.Easy To Wear With Head-Gear And Easy To Clean In Warm Soap Water.The Capstrap Headgear With Intuitive Talon Clips That Can Be Quickly Removed For Oral Access To The Patient.5 Adjustment Points To Ensure Optimal Anatomical Positioning And Enhancing Patient Comfort. Deep Sealing Flange On The Nose Bridge To Help Create A Low Pressure Seal. Should Be Non-Vented. , Niv Mask Medium - Made Of Silicone & Plastic Material Adopting To Different Face Sizes. Should Be Leak Proof.Easy To Wear With Head-Gear And Easy To Clean In Warm Soap Water.The Capstrap Headgear With Intuitive Talon Clips That Can Be Quickly Removed For Oral Access To The Patient.5 Adjustment Points To Ensure Optimal Anatomical Positioning And Enhancing Patient Comfort. Deep Sealing Flange On The Nose Bridge To Help Create A Low Pressure Seal. Should Be Non-Vented. , Oxygen Mask Adult - Should Cover The Nose And Mouth Manufactured From Soft Non Toxic Medical Grade Pvc Compound Should Be Transparent Odour Free And Lightweight Should Have An Elastic Strap And Aluminum Nose Clip Is Provided On The Mask For Proper Adjustment Of Mask On Nasal Area Should Have Multichannel Tube Ensure Regular Supply Of Oxygen If Tube Is Accidently Kinked. The Tube Should Be Provided With Connecters At Both Ends For Easy Connection With Oxygen Source. Tube Length-210Cm.Ce Marked Packed In One Palstic Bag With Label Containing Product Name .Mfg.Date Exp.Date Mfg.By. , Vicryl 3-0 Cutting - Needle Length 25Mmsuture Length 90Cmcolour Undyedsuture Type Synthetic Braidedabsorption Profile Absorbable 56 - 70 Days Average 63 Days Suture Diameter Usp 3-0Suture Material Polyglactin 910Needle Description 25Mm 3 8 Circle Cutting Ethiprime Needlecoating Calcium Stearate , Vicryl 4-0 R Cutting 2494 - Needle Length 12Mmsuture Length 45Cmcolour Violetsuture Type Synthetic Braidedabsorption Profile Absorbable 56 - 70 Days Average 63 Days Suture Diameter Usp 4-0Suture Material Polyglactin 910Needle Description 12Mm 3 8 Circle Reverse Cutting Needlecoating Calcium Stearatetensile Strength 75% Retention At 14 Days 50% Retention At 21 Days 25% Retention At 28 Days , Biopsy Gun No 16 - Automated Spring Loaded Core Biopsy Instrument Disposable 16G X 16Cm , Biopsy Gun No 18 - Automated Spring Loaded Core Biopsy Instrument Disposable 18G X 10Cm , Ethilon Loop No 1 3348 - Nylon Monofilament Nonabsorbable Polymers With Needle 1 2 Circle Round Body Heavy Needle Loop Suture 50 Mm Length 150 Cm Size 1 , Ethilon 4-0 Round Body - Monofilament Polyamide Needle Length 10Mm Suture 38Cm 3 8 Circle Round Body Needle , Dressing Trolly - 2X3 Feet , Dressing Drum Small - 11X9 Inches Stainless Steel , Dressing Drum Medium - 12X10 Inches Stainless Steel , Dressing Drum Jumbo - 18X15 Inches Stainless Steel , Tooth Forcep Medium - 6 Nches Stainless Steel , Needle Holder - 6 Nches Stainless Steel , Plain Scissor - 6 Nches Stainless Steel , Plain Artery Forceps - 6 Nches Stainless Steel , Curved Artery Forceps - 6 Nches Stainless Steel , Plain Forceps - 6 Nches Stainless Steel Total Quantity : 1558160

Key Value

Document Fees
Refer document
EMD
INR 325000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail