}

Tender For Supply , Installation , Testing And Commissioning Of Flowmeters In Zonal Reservoirs With Other Ancillary Work In Dharamgarh Nac, dharamgarh-Odisha

Public Health Engineer Organisation has published Tender For Supply , Installation , Testing And Commissioning Of Flowmeters In Zonal Reservoirs With Other Ancillary Work In Dharamgarh Nac. Submission Date for this Tender is 26-08-2025. Flowmeters Tenders in dharamgarh Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

50703038
Tender For Supply , Installation , Testing And Commissioning Of Flowmeters In Zonal Reservoirs With Other Ancillary Work In Dharamgarh Nac
Tender
Indian
Odisha
Dharamgarh
26-08-2025

Tender Details

Supply , Installation , Testing And Commissioning Of Flowmeters In Zonal Reservoirs With Other Ancillary Work In Dharamgarh Nac- 1 Supply, install and commission Electromagnetic Flow Meter(EMF) As Per ISO 4064, for Raw/Pure water with accuracy +/- 0.5% of measured value & protection as per given specifications for size 100 mm1000mm including sensor, transm itter surge arrestor, cable GI duct if suitable size for 25 mtrs built in GSM/GPRS ( with Simcard and its charges,valid for 36 months) including the pipe cutting, leveling and installation of flow meter in the pipelines with necessary tool tackles, cranes including 36 months guarantee etc complete, as may be required at site & based on technical specifications.1) The sensor should be as per IP-68 protection & with flanges of PN 10 rating from CS-1 No.2) The sensor coil housing shall be IP-68.This protected against external magnetic field.3) The transmitter shall have one current 4 m A-20 mA output.4) The current output shall be galvanically / optically isolated. transients without damage. It shall be fitted with switched mode power supply capability 85- 260 V & 45-65 Hz to cope up with power transient without damage 2 5) Signal & power cables shall be of 50 Mtrs length/each. 6) Conduit pipe ( PVC Plumbing schedule 4 ) 25 mm diameter with suitable rating of cable with digging, laying & concealed the duct - 25 mtrs/each 7) UPS working on 230 V AC, 50 Hz power supply suitable for 12 hrs continuous operation-1 No. 8) Data storage capacity with built in or separate for date time, actual flow rate, totaliser & error messages if any with storage capacity of 120 days -1 No. 9) Proper earthing shall be provided for protection against high voltage surge. 10) Suitable over voltage protection unit for protection of instrument from higher voltage (upto 275 V-300 V AC) 3 200 mm Nominal DiameterInside WTP 4 300 mm Nominal DiameterFlowmeterat Kebidi and Revenue Colony Pump House 5 350 mm Nominal DiameterFlowmeterat Intake Pump House 6 Supplying with fittings and fixing of D.I Mechanical dismentaling joint for use to main uninterrupted water supply in the pipeline in case of flowmeter as per specification and direction of Engineer-in-charge. (PN-1.6) 7 200 mm Nominal Diameter 8 300 mm Nominal Diameter 9 350 mm Nominal Diameter 10 Supplying all materials,labour and T&P and constructing brick masonry chamber as per P.H. specification and design all complete excluding RCC Cover Slab(per each) (1.20 X 1.20 X 1.00) 11 Cutting of C.I /DI pipe by eletric arc welding,at site including cost of materials,labour,T & P etc all complete 12 Level Transmitter Supply, erection, testing commissioning of ultrasonic level transmitter having a range of 0-20 mtrs with an accuracy of 10.25% of measured distance with all necessary accessores like suitable rated cable gland, blanking plug, base frame, non metallic flanges, canopy etc and other accessories required for the proper installation & functioning of level transmitter and interfacing with the proposed SCADA-PLC system. The level transmitter shall be a 2 wire system with 4-20mA analogy output and 2 nos digital out puts. The protection class of level transmitter shall be NEMA4X, IP66 at Revenue Colony pump House and Kasibahal Pump House. Make ke E&H/VEGA/SIEMENS/FORBES/MARSHALL/UWT) 13 Design, manufacture, supply,installation, testing andcommissioning of indoor type PLC panel of size approxPLC Indoor panel Made out of 2MM C.R sheet of size (1000mm X 700 mm X 1500mm floor mounted) powered coated 7 tank process with following component i.e.CPU should have 1MB program memory with extended memory slut, Redundand-24VDC, SMPS 10Amp along with 24V DC SPD,JO count as DI-20,DO-20.AI 20,AO-20 &MODBUS-10. Subsysytem shall be same series as CPU, 7inch Panel Mounted HMI, Modern should have suporrt MQTT Protocol by default, 24volt DC Industrial Switch with minium 6 eathmate. 4 SFP Port each Al shall be equiped with suitable signal isolator of 20Nos & surge protectiondevice 20nos LIU AC Isolator, 230 Volt AC/230volt torroidal transfemer, 1KVA 230V AC UPS should have capacity to Charge 3 nos 12VDC 65 AH Battery Bank, DP MCB of Adequate current capacity, Led tube light 10inch 5watt door limit switch louver, 4sqmm straighi through terminal & fuse terminal 90 nos. earthing plate(PLC- Sieemens, Schnider Phonix, ABB Mitsubishi, SMPS- Phoenix, Slemens, Schnider Isolater Masibus, Rishabh, Multispan, SPD-Phoenix, Mersen, Make Dehn UPS -Vertive. 14 supply,installation, testing and commissioning of XLPE ARMOURED Cables with COPPER Conductor 650/1100 V. Grade confirming to IS : 7098 (Pt-1) 1988 15 1.5Sqmm 10 core armoured cable 16 1.5Sqmm 3 core armoured cable 17 0.75 Sqmm2 Core armoured Screen cable

Key Value

Document Fees
INR 6000 /-
EMD
INR 17615.0 /-
Tender Value
INR 17.61 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail