Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #50703038

Tender For Supply , Installation , Testing And Commissioning Of Flowmeters In Zonal Reservoirs With Other Ancillary Work In Dharamgarh Nac

Issued by Government Departments · dharamgarh, Odisha
Tender Value
17.61 Lakhs
Estimated cost
Bid Submission
26 Aug 2025
0 days left
EMD
17615
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
dharamgarh → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Supply , Installation , Testing And Commissioning Of Flowmeters In Zonal Reservoirs With Other Ancillary Work In Dharamgarh Nac- 1 Supply, install and commission Electromagnetic Flow Meter(EMF) As Per ISO 4064, for Raw/Pure water with accuracy +/- 0.5% of measured value & protection as per given specifications for size 100 mm1000mm including sensor, transm itter surge arrestor, cable GI duct if suitable size for 25 mtrs built in GSM/GPRS ( with Simcard and its charges,valid for 36 months) including the pipe cutting, leveling and installation of flow meter in the pipelines with necessary tool tackles, cranes including 36 months guarantee etc complete, as may be required at site & based on technical specifications.1) The sensor should be as per IP-68 protection & with flanges of PN 10 rating from CS-1 No.2) The sensor coil housing shall be IP-68.This protected against external magnetic field.3) The transmitter shall have one current 4 m A-20 mA output.4) The current output shall be galvanically / optically isolated. transients without damage. It shall be fitted with switched mode power supply capability 85- 260 V & 45-65 Hz to cope up with power transient without damage 2 5) Signal & power cables shall be of 50 Mtrs length/each. 6) Conduit pipe ( PVC Plumbing schedule 4 ) 25 mm diameter with suitable rating of cable with digging, laying & concealed the duct - 25 mtrs/each 7) UPS working on 230 V AC, 50 Hz power supply suitable for 12 hrs continuous operation-1 No. 8) Data storage capacity with built in or separate for date time, actual flow rate, totaliser & error messages if any with storage capacity of 120 days -1 No. 9) Proper earthing shall be provided for protection against high voltage surge. 10) Suitable over voltage protection unit for protection of instrument from higher voltage (upto 275 V-300 V AC) 3 200 mm Nominal DiameterInside WTP 4 300 mm Nominal DiameterFlowmeterat Kebidi and Revenue Colony Pump House 5 350 mm Nominal DiameterFlowmeterat Intake Pump House 6 Supplying with fittings and fixing of D.I Mechanical dismentaling joint for use to main uninterrupted water supply in the pipeline in case of flowmeter as per specification and direction of Engineer-in-charge. (PN-1.6) 7 200 mm Nominal Diameter 8 300 mm Nominal Diameter 9 350 mm Nominal Diameter 10 Supplying all materials,labour and T&P and constructing brick masonry chamber as per P.H. specification and design all complete excluding RCC Cover Slab(per each) (1.20 X 1.20 X 1.00) 11 Cutting of C.I /DI pipe by eletric arc welding,at site including cost of materials,labour,T & P etc all complete 12 Level Transmitter Supply, erection, testing commissioning of ultrasonic level transmitter having a range of 0-20 mtrs with an accuracy of 10.25% of measured distance with all necessary accessores like suitable rated cable gland, blanking plug, base frame, non metallic flanges, canopy etc and other accessories required for the proper installation & functioning of level transmitter and interfacing with the proposed SCADA-PLC system. The level transmitter shall be a 2 wire system with 4-20mA analogy output and 2 nos digital out puts. The protection class of level transmitter shall be NEMA4X, IP66 at Revenue Colony pump House and Kasibahal Pump House. Make ke E&H/VEGA/SIEMENS/FORBES/MARSHALL/UWT) 13 Design, manufacture, supply,installation, testing andcommissioning of indoor type PLC panel of size approxPLC Indoor panel Made out of 2MM C.R sheet of size (1000mm X 700 mm X 1500mm floor mounted) powered coated 7 tank process with following component i.e.CPU should have 1MB program memory with extended memory slut, Redundand-24VDC, SMPS 10Amp along with 24V DC SPD,JO count as DI-20,DO-20.AI 20,AO-20 &MODBUS-10. Subsysytem shall be same series as CPU, 7inch Panel Mounted HMI, Modern should have suporrt MQTT Protocol by default, 24volt DC Industrial Switch with minium 6 eathmate. 4 SFP Port each Al shall be equiped with suitable signal isolator of 20Nos & surge protectiondevice 20nos LIU AC Isolator, 230 Volt AC/230volt torroidal transfemer, 1KVA 230V AC UPS should have capacity to Charge 3 nos 12VDC 65 AH Battery Bank, DP MCB of Adequate current capacity, Led tube light 10inch 5watt door limit switch louver, 4sqmm straighi through terminal & fuse terminal 90 nos. earthing plate(PLC- Sieemens, Schnider Phonix, ABB Mitsubishi, SMPS- Phoenix, Slemens, Schnider Isolater Masibus, Rishabh, Multispan, SPD-Phoenix, Mersen, Make Dehn UPS -Vertive. 14 supply,installation, testing and commissioning of XLPE ARMOURED Cables with COPPER Conductor 650/1100 V. Grade confirming to IS : 7098 (Pt-1) 1988 15 1.5Sqmm 10 core armoured cable 16 1.5Sqmm 3 core armoured cable 17 0.75 Sqmm2 Core armoured Screen cable

BOQ

Name of Work: Supply , installation , testing and commissioning of flowmeters in zonal reservoirs with other ancillary work in Dharamgarh NAC.
Sl. No. Item Description
1Supply, install and commission Electromagnetic Flow Meter(EMF) As Per ISO 4064, for Raw/Pure water with accuracy +/- 0.5% of measured value & protection as per given specifications for size 100 mm1000mm including sensor, transm itter surge arrestor, cable GI duct if suitable size for 25 mtrs built in GSM/GPRS ( with Simcard and its charges,valid for 36 months) including the pipe cutting, leveling and installation of flow meter in the pipelines with necessary tool tackles, cranes including 36 months guarantee etc complete, as may be required at site & based on technical specifications.1) The sensor should be as per IP-68 protection & with flanges of PN 10 rating from CS-1 No.2) The sensor coil housing shall be IP-68.This protected against external magnetic field.3) The transmitter shall have one current 4 m A-20 mA output.4) The current output shall be galvanically / optically isolated. transients without damage. It shall be fitted with switched mode power supply capability 85- 260 V & 45-65 Hz to cope up with power transient without damage
25) Signal & power cables shall be of 50 Mtrs length/each. 6) Conduit pipe ( PVC Plumbing schedule 4 ) 25 mm diameter with suitable rating of cable with digging, laying & concealed the duct - 25 mtrs/each 7) UPS working on 230 V AC, 50 Hz power supply suitable for 12 hrs continuous operation-1 No. 8) Data storage capacity with built in or separate for date time, actual flow rate, totaliser & error messages if any with storage capacity of 120 days -1 No. 9) Proper earthing shall be provided for protection against high voltage surge. 10) Suitable over voltage protection unit for protection of instrument from higher voltage (upto 275 V-300 V AC)
3200 mm Nominal DiameterInside WTP
4300 mm Nominal DiameterFlowmeterat Kebidi and Revenue Colony Pump House
5350 mm Nominal DiameterFlowmeterat Intake Pump House
6Supplying with fittings and fixing of D.I Mechanical dismentaling joint for use to main uninterrupted water supply in the pipeline in case of flowmeter as per specification and direction of Engineer-in-charge. (PN-1.6)
7200 mm Nominal Diameter
8300 mm Nominal Diameter
9350 mm Nominal Diameter
10Supplying all materials,labour and T&P and constructing brick masonry chamber as per P.H. specification and design all complete excluding RCC Cover Slab(per each) (1.20 X 1.20 X 1.00)
11Cutting of C.I /DI pipe by eletric arc welding,at site including cost of materials,labour,T & P etc all complete
12Level Transmitter Supply, erection, testing commissioning of ultrasonic level transmitter having a range of 0-20 mtrs with an accuracy of 10.25% of measured distance with all necessary accessores like suitable rated cable gland, blanking plug, base frame, non metallic flanges, canopy etc and other accessories required for the proper installation & functioning of level transmitter and interfacing with the proposed SCADA-PLC system. The level transmitter shall be a 2 wire system with 4-20mA analogy output and 2 nos digital out puts. The protection class of level transmitter shall be NEMA4X, IP66 at Revenue Colony pump House and Kasibahal Pump House. Make ke E&H/VEGA/SIEMENS/FORBES/MARSHALL/UWT)
13Design, manufacture, supply,installation, testing andcommissioning of indoor type PLC panel of size approxPLC Indoor panel Made out of 2MM C.R sheet of size (1000mm X 700 mm X 1500mm floor mounted) powered coated 7 tank process with following component i.e.CPU should have 1MB program memory with extended memory slut, Redundand-24VDC, SMPS 10Amp along with 24V DC SPD,JO count as DI-20,DO-20.AI 20,AO-20 &MODBUS-10. Subsysytem shall be same series as CPU, 7inch Panel Mounted HMI, Modern should have suporrt MQTT Protocol by default, 24volt DC Industrial Switch with minium 6 eathmate. 4 SFP Port each Al shall be equiped with suitable signal isolator of 20Nos & surge protectiondevice 20nos LIU AC Isolator, 230 Volt AC/230volt torroidal transfemer, 1KVA 230V AC UPS should have capacity to Charge 3 nos 12VDC 65 AH Battery Bank, DP MCB of Adequate current capacity, Led tube light 10inch 5watt door limit switch louver, 4sqmm straighi through terminal & fuse terminal 90 nos. earthing plate(PLC- Sieemens, Schnider Phonix, ABB Mitsubishi, SMPS- Phoenix, Slemens, Schnider Isolater Masibus, Rishabh, Multispan, SPD-Phoenix, Mersen, Make Dehn UPS -Vertive.
14supply,installation, testing and commissioning of XLPE ARMOURED Cables with COPPER Conductor 650/1100 V. Grade confirming to IS : 7098 (Pt-1) 1988
151.5Sqmm 10 core armoured cable
161.5Sqmm 3 core armoured cable
170.75 Sqmm2 Core armoured Screen cable

AI Tender Summary

OUR REF NO 50703038
AUTHORITY Government Departments
TENDER VALUE 17.61 Lakhs
LAST DATE 26-08-2025
Authority
Authority Name Public Health Engineer Organisation
Work Description Supply , Installation , Testing And Commissioning Of Flowmeters In Zonal Reservoirs With Other Ancillary Work In Dharamgarh Nac- 1 Supply, install and commission Electromagnetic Flow Meter(EMF) As Per ISO 4064, for Raw/Pure water with accuracy +/- 0.5% of measured value & protection as per given specifications for size 100 mm1000mm including sensor, transm itter surge arrestor, cable GI duct if suitable size for 25 mtrs built in GSM/GPRS ( with Simcard and its charges,valid for 36 months) including the pipe cutting, leveling and installation of flow meter in the pipelines with necessary tool tackles, cranes including 36 months guarantee etc complete, as may be required at site & based on technical specifications.1) The sensor should be as per IP-68 protection & with flanges of PN 10 rating from CS-1 No.2) The sensor coil housing shall be IP-68.This protected against external magnetic field.3) The transmitter shall have one current 4 m A-20 mA output.4) The current output shall be galvanically / optically isolated. transients without damage. It shall be fitted with switched mode power supply capability 85- 260 V & 45-65 Hz to cope up with power transient without damage 2 5) Signal & power cables shall be of 50 Mtrs length/each. 6) Conduit pipe ( PVC Plumbing schedule 4 ) 25 mm diameter with suitable rating of cable with digging, laying & concealed the duct - 25 mtrs/each 7) UPS working on 230 V AC, 50 Hz power supply suitable for 12 hrs continuous operation-1 No. 8) Data storage capacity with built in or separate for date time, actual flow rate, totaliser & error messages if any with storage capacity of 120 days -1 No. 9) Proper earthing shall be provided for protection against high voltage surge. 10) Suitable over voltage protection unit for protection of instrument from higher voltage (upto 275 V-300 V AC) 3 200 mm Nominal DiameterInside WTP 4 300 mm Nominal DiameterFlowmeterat Kebidi and Revenue Colony Pump House 5 350 mm Nominal DiameterFlowmeterat Intake Pump House 6 Supplying with fittings and fixing of D.I Mechanical dismentaling joint for use to main uninterrupted water supply in the pipeline in case of flowmeter as per specification and direction of Engineer-in-charge. (PN-1.6) 7 200 mm Nominal Diameter 8 300 mm Nominal Diameter 9 350 mm Nominal Diameter 10 Supplying all materials,labour and T&P and constructing brick masonry chamber as per P.H. specification and design all complete excluding RCC Cover Slab(per each) (1.20 X 1.20 X 1.00) 11 Cutting of C.I /DI pipe by eletric arc welding,at site including cost of materials,labour,T & P etc all complete 12 Level Transmitter Supply, erection, testing commissioning of ultrasonic level transmitter having a range of 0-20 mtrs with an accuracy of 10.25% of measured distance with all necessary accessores like suitable rated cable gland, blanking plug, base frame, non metallic flanges, canopy etc and other accessories required for the proper installation & functioning of level transmitter and interfacing with the proposed SCADA-PLC system. The level transmitter shall be a 2 wire system with 4-20mA analogy output and 2 nos digital out puts. The protection class of level transmitter shall be NEMA4X, IP66 at Revenue Colony pump House and Kasibahal Pump House. Make ke E&H/VEGA/SIEMENS/FORBES/MARSHALL/UWT) 13 Design, manufacture, supply,installation, testing andcommissioning of indoor type PLC panel of size approxPLC Indoor panel Made out of 2MM C.R sheet of size (1000mm X 700 mm X 1500mm floor mounted) powered coated 7 tank process with following component i.e.CPU should have 1MB program memory with extended memory slut, Redundand-24VDC, SMPS 10Amp along with 24V DC SPD,JO count as DI-20,DO-20.AI 20,AO-20 &MODBUS-10. Subsysytem shall be same series as CPU, 7inch Panel Mounted HMI, Modern should have suporrt MQTT Protocol by default, 24volt DC Industrial Switch with minium 6 eathmate. 4 SFP Port each Al shall be equiped with suitable signal isolator of 20Nos & surge protectiondevice 20nos LIU AC Isolator, 230 Volt AC/230volt torroidal transfemer, 1KVA 230V AC UPS should have capacity to Charge 3 nos 12VDC 65 AH Battery Bank, DP MCB of Adequate current capacity, Led tube light 10inch 5watt door limit switch louver, 4sqmm straighi through terminal & fuse terminal 90 nos. earthing plate(PLC- Sieemens, Schnider Phonix, ABB Mitsubishi, SMPS- Phoenix, Slemens, Schnider Isolater Masibus, Rishabh, Multispan, SPD-Phoenix, Mersen, Make Dehn UPS -Vertive. 14 supply,installation, testing and commissioning of XLPE ARMOURED Cables with COPPER Conductor 650/1100 V. Grade confirming to IS : 7098 (Pt-1) 1988 15 1.5Sqmm 10 core armoured cable 16 1.5Sqmm 3 core armoured cable 17 0.75 Sqmm2 Core armoured Screen cable
Basic Detail
Tender No SEPH BHPT 13 of 2025-26
Bidding Type Tender
Location
City dharamgarh
State Odisha
Key Dates
Publish Date 16 Aug 2025
Submission Date 26 Aug 2025
Open Date 29 Aug 2025
Finance
Tender Value 17.61 Lakhs
Tender Fee 6000
EMD 17615
Exemption Available
Document List
BOQ_549396.xls
Tendernotice_1.pdf
5c8d1f99-0c40-4feb-800c-1e17cfb93fbb.html
dtcn.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 16, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 26, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 29, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_549396.xls

pdf

Tendernotice_1.pdf

html

5c8d1f99-0c40-4feb-800c-1e17cfb93fbb.html

pdf

dtcn.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders