Tender For Procurement Of Various Types Of Transducers,Clamp Meter, Multimeter And Panel Meterfor 210 Mw, Atps,Chachai - Active Power Transducer (MW Transducer)Should have following specifications :- (a) 3 phase 4 wire voltage & current unbalanced (b)Input: - 63.508V AC, 0 - 0.8748 A , AC 50 Hz. (c) Aux. Power Supply:- 220 V AC/DC(d)Accuracy: - ±0.5% of span.(f)CTR :- 1600/ 1 A ,AC 50 Hz.(g)Range: - 0-16 MW.(h) with LCD display, Fully onsite programmable input voltage range and input current range, Measuring range programmable, onsite selectable output type( DC current/ DC voltage), Output range Programmable(i) Output :- Dual isolated 4-20 mA DC(j) Make: AE,Masibus, Rishabh, Southern, Minilec, Meco or equivalent 2 Active Power Transducer(MW Transducer)Should have following specifications :- (a) 3 phase 4 wire voltage & current unbalanced(b)Input :- 63.508V AC, 0 - 1.021 A ,AC 50 Hz.(c)Aux. Power supply: - 220 V AC/DC.(d)Accuracy: - ±0.5% of span.(e) PTR:- 6600/√3/110//√3 V, AC 50 hz(f)CTR :- 3000/ 1 A ,AC 50 Hz.(g)Range: - 0-35 MW.(h) with LCD display, Fully onsite programmable input voltage range, Measuring range programmable, onsite selectable output type( DC current/ DC voltage), Output range Programmable(i)Output:- Dual isolated4-20 mA DC(j)Make: AE,Masibus, Rishabh, Southern, Minilec, Meco or equivalent 3 AC Voltage TransducerShould have following specifications :-(a)Input :- Nominal 110V, AC 50 Hz(b)Range Input :- 0-166.667 V AC.(c)Aux. Power supply: - 220 V AC/DC.(d)Accuracy: - ±0.5% of span.(f)Range :- 0-10KV(g)Output: - Dual isolated 4-20mA DC.(h) with LCD display, Fully onsite programmable input voltage range, Measuring range programmable, onsite selectable output type( DC current/ DC voltage), Output range Programmable(i) Make: AE,Masibus, Rishabh, Southern, Minilec, Meco or equivalent 4 AC Current TransducerShould have following specifications :-(a)Input :- 0-1A, AC 50 Hz(b)Aux. Power supply: - 220 V AC/DC.(c)Accuracy: - ±0.5% of span.(d) Output: - Dual isolated 4-20mA DC.(e) with LCD display, Fully onsite programmable input voltage range, Measuring range programmable, onsite selectable output type( DC current/ DC voltage), Output range Programmable(f) Make: AE,Masibus, Rishabh, Southern, Minilec, Meco or equivalent 5 Watt Transducer (a) Range : 0-250 MW (b) Input: 0-873 W (c) PTR: 15.75√3KV/110√3V (d) CT: 10000/5A (e) Output :4-20 mA DC (Dual Output) (f)Make: AE, Rishabh, Southern, Minilec,Meco or equivalent (g) Fully onsite programmable input voltage range and input current range with LCD Display (h) Onsite selectable output type (DC current / DC voltage). (i)Aux Supply: 220 V DC / AC ( both), (j) Type :3Phase 4 wire 6 Watt Transducer (a)Range :(-) 228.6 -0 - (+) 228.6 MW (b)Input: (-) 190.5 – 0 - (+) 190.5 W (c)Output :4-12-20 mA DC (Dual Output) (d)PTR : 220KV√3/ 110√3V (e)CTR : 600/1 A (f) Accuracy: ± 0.5% (g)Aux Supply : 220 V DC / AC (both), (h)Make: AE, Rishabh, Southern, Minilec, masibus or equivalent (i) Fully onsite programmable input voltage range and input current range with LCD display (j)Onsite selectable output type (DC current / DC voltage). (k)Type :3Phase 4 wire (l) Make: AE,Masibus, Rishabh, Southern, Minilec, Meco or equivalent 7 MVAR Transducer (i)Range:(-) 228.6-0 - (+) 228.6 MVAR(ii)Input: (-) 190.5 – 0 - (+) 190.5 VAR(iii) Output:4-12-20 mA DC (Dual Output)(iv) PTR: 220KV√3/ 110√3V(V) CTR : 600/1 A(vi) Accuracy: ± 0.5%(Vii) Aux Supply: 220 V DC / AC ( both), (viii) Type:3Phase 4 wire (ix) Make: AE, Rishabh, Southern, Minilec,masibus or equivalent. (x) Fully onsite programmable input voltage range and input current range with LCD display(xi)Onsite selectable output type (DC current / DC voltage) 8 Watt Transducer (Universal)(a) Range:(-) 228.6 -0 - (+) 228.6 MW(b) Input : (-) 190.52 – 0 - (+) 190.52 W(c) Output:4-12-20 mA DC(Dual Output)(d) PTR : I/P 110V(e) CTR: I/P 1 A(f)Class:0.5(g) Aux Supply : 220 V DC/AC ( both),(h) Make : AE,Masibus, Rishabh, Southern, Minilec, MEco or equivalent (i)Fully onsite programmable input voltage range and input current range with LCD display(j)Onsite selectable output type (DC current / DC voltage).(k) Type:3Phase 4 wire 9 MVAR Transducer (Universal) (i)Range :(-) 228.6-0 - (+) 228.6 MVAR(ii) Input : (-) 190.5 – 0 - (+) 190.5 VAR(iii)Output :4-12-20 mA DC (Dual Output)(iv)PTR: I/P 110V(V)CTR : I/P 1 A(vi)Accuracy : ± 0.5%(Vii) Aux Supply : 220 V DC / AC ( both),(Viii)Make: AE, Rishabh, Southern, Minilec,masibus or equivalent (ix) Fully onsite programmable input voltage range and input current range with LCD display (x) Onsite selectable output type (DC current / DC voltage). (vii)Type:3Phase 4 wire 10 AC Voltage TransducerShould have following specifications :-(a)Input :- 0-150 V AC,50 Hz(b)PT :- 220KV√3/110√3 V.(c)Aux. Power supply: - 220 V AC/DC.(d)Accuracy: - ±0.5% of span.(f)Range :- 0-300KV(g)Output: - Dual isolated 4-20mA DC. 500 ohm (max)(h) with LCD display, Fully onsite programmable input voltage range, Measuring range programmable, onsite selectable output type( DC current/ DC voltage), Output range Programmable 11 DC Ammeter (i)Range : 0-200 A (ii) Size: 72*72(iii)Accuracy:1.5or BETTER TYPE(iV)Scale : 240° (V) Make : AE, Rishabh, Southern, Minilec, or equivalent(Vi) Input range : 0-75 mV 12 DC Ammeter (i)Range : 0-100-600 A (ii) Size: 72*72(iii)Accuracy:1.5or BETTER TYPE(iV)Scale : 240° (V) Make : AE, Rishabh, Southern, Minilec, or equivalent(Vi) Input range : 0-75 mV 13 DC Ammeter (i)Range : 0-100 A (ii) Size: 72*72(iii)Accuracy:1.5or BETTER TYPE(iV)Scale : 240° (V) Make: AE, Rishabh, Southern, Minilec, or equivalent(Vi) Input range: 0-75 mV 14 DC Ammeter (i)Range : 0-150 A (ii) Size: 72*72(iii)Accuracy:1.5or BETTER TYPE(iV)Scale : 240° (V) Make: AE, Rishabh, Southern, Minilec, or equivalent(Vi) Input range: 0-75 mV 15 DCVoltage Transducer (i) Input: -15V-0-+15 V DC (ii)Output :4-20 mA (DUAL and GALVANICALLY ISOLATED) (iii)Accuracy: ± 0.5% or BETTER TYPE(iV) Aux Supply: 220 VAC/DC , 1Ph 50 HZ(V)Make : AE, Rishabh, Southern, Minilec, Masibus or equivalent(Vi) Test voltgae : 2KV, 50 HZ/MIN