| 1 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 2 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.15.23.1 For thickness oftiles 10 mm to 25mm |
| 3 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead: 15.12.1 Of area 3 sq.metre sand below |
| 4 | Taking out doors, window sand clerestory window shutters (steel or wood) including stacking within 50 metres lead: 15.13.1 Of area 3 sq.metres and below |
| 5 | Dismantling old plaster or skirting raking out joints and cleaning thesurface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 6 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 7 | 1:2:4 (1 cement: 2 coarses and (zone-Ill) derived from natural sources:4 graded stone aggregate 20 mm nominal size derved from natural sources) |
| 8 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.14.1.2 With cement mortar 1:4 (1cement:4 coarse sand) |
| 9 | Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-In-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement:4 coarse sand) laid and join led with grey cement slurry,including rubbing and polishing complete with:11.23.2 Raj Nagar plain sqm |
| 10 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15x10x10cm with cement concrete1:3:6 (1cement : 3 coarses and : 6 graded stone aggregate 20mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.14.2.1 Door chowkhats |
| 11 | Brick work with common burnt clay F.P.S.(no modular) bricks of class designation 7.5in superstructure above plinth level upto floor V level in all shapes and sizes in:6.4.2 Cement mortar 1:6 (1cement : 6 coarse sand) |
| 12 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with waler absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colour sand shades, laid on 20mm thick cement mortar 1:4 (1cement : 4 coarse sand), jointingwith grey cement slurry @3.3kg/sqm including grouting the joints with while cement and matching pigments etc.,complete.11.41.2Size of Tile 600x600mm |
| 13 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (PartI) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 9.21.2-30mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 14 | Providing and fixing angle Iron frames for doors, windows and ventilators of mildsteel Angle sections of size 35x35x5mm, joints mitred and welded by angle iron 35x35x5mm or 35x5mm ftal pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat or approved steel primer, all complete as per the directionof Engineer-In-charge. |
| 15 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 15.7.4 In cement mortar |
| 16 | Providing and fixing cupboard shuller with 19 mm thick one side decorative and other side balancing lamination f-dctory pressed BWP grade marine ply as per IS 710 of approved brand Including 2 mm thick PVC edge banding tape with hot glue by edge bending machine etc.with auto closing spring loaded hinges (hydraulic type) etc.complete as per direction of Engineer-in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately) |
| 17 | 12 mm cement plaster of mix:13.4.2 1:6 (1 cement : 6 coarse sand) |
| 18 | Providing & fixing UV stabilised fiber glass reinforced plastic sheet roofing upto anypitch, including fixing with polymer coated \"J\" or \"L\" hooks, bolts & nuts 8mm dia. G.I plain / bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufact 1.1 red out or 2400 TEXpanel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi andhot cured. They shall be of uniform pigmentation and thickness withoutairpockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.12.47.2 2 mm thick flat |
| 19 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 20 | Providing & fixing Hy proof wire gauze 10 windows, clerestory windows&doors with M.S.Flat 15x3 mm and nuts & bolts complete.10.29.2 Slainless steel (grade 304) wire gauze or 0.5mm dla wireand1.4 mm aperture on both sides |
| 21 | Renewing glass panes and refixing existing wooden fillets:14.7.2Float glass panes of nominal thickness 5 mm (weight not less than 12.5 kg/sqm) |
| 22 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :13.99.1 One or more coats on old work |
| 23 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 24 | Providing and applying white cement based putty of average thickness 1 mm,of approved brand and manufacturer, over the plastered wall surface ofcement 78.35 to prepare the surface even and smooth complete. |
| 25 | Wall painting wirh premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compund) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shadeand colour. 13.83.2 Two coats |
| 26 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished ,machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand), Joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.8.2.2 Granite stones lab of colour black, Cherry/Ruby red8.2.2.2 Area of slab over 0.50 sqm |
| 27 | Finishing walls with acrylic smooth exterior paint of required shades :13.46.1 New work (Two or more coat applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/4010sqm) |
| 28 | Polishing on wood work with ready mixed wax polishing of approved brand and manufacture:13.69.1 New work |
| 29 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to bespecified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar1:3 (1cement : 3 coarse sand) and joining with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 30 | 1:2:8 (1 cement: 4 coarse sand (zone-III) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derved from natural sources) |
| 31 | Extra for cutting reinforcement bars manually / by mechanical means in R.C.C.or R.B. Work (Payment shall be made on the cross sectional area of R.C.C. Or R.B.work) as per direction of Engineer-in-charge. |
| 32 | Providing edge moulding to 18 mm thick marble stone counters. Vanities etc., inciuding machine polishing to edge to give high gloss finish etc. Complete as per design approved by Engineer-in-Charge.8.3.2 Granite work |
| 33 | Providing and fixing tiled false ceiling or specified materials of size595x59 5mm in true horizontal level, suspended on Interlockingmetal gridof hot dipped galvanized steel sections (galvanized @120 grams/sqm, both side inclusive) consisting of main\"T\" runner with suitably spacedjoints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\"\" at 600 mm center to center to form agrid of 1200x600 mm and secondary cross \"T\" of length 600mm and size24X25 mm madeof 0.30mm thick (minimum) sheet to be interloeked at middle of the 1200x600 mm panel to form grids of 600x600mm andwall angle or size 24x24x0.3 mm and laying false ceiling tiles of approvedtexture in the grid including, required cutting/making,opening for services like diffusers, grills,light fittings, fixtures, smoke detectors etc.Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27x 37x25x1.6mm fixed to ceiling with 12.5mm diaand 50mm long dashfasteners, 4 mm GIadjustable rodswithgalvanisedbuUerfly levelclips of size85 x 30x 0.8mm spaced at 1200 mm center to center along main T. bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawingsand as directed by Engineer-in-charge. 12.52.4 12.5 mm thick full Perforated Gypsum Board tile made fromplaster board having glass fibre conforming to IS : 2095 part I, of size 595x595mm, having perforation of 9.7x9.7mm at 19.4 mm c/c with center border so (48 mm and the sideborders of 30mm, backed with non woven tissue on the backside, having an NRC (Noise Reduction Coefficient) or 0.79,with 50mm resin bonded glass wool baeking. |
| 34 | P/F bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 35 | P/F ISI marked oxidise M.S. tower bolt black finish, (Barrel type) with necessary screw etc. complete (Copper oxidised as per IS 1378) 9.63.1 250x10 mm |
| 36 | Providing and fixing ready made 304 grade stainless steel Modular kitchen basket and accessories such as right angle basket (Plain Cup & Saucer, plant, Partition, Bottle rack, Thali, Cutlery) kitchen utensil basket, Dinner set basket, kitchen grain basket, Multipurpose basket as per site requirement including finishing (wherever required) and fittings. The same shall be fixed with necessary stainless steel nuts & bolts, Stainless Steel screws & telescopic channel etc. as per direction of Engineer-In-charge. (For payment purpose only weight of Stainless steel basket shall be considered excluding weight of all fixing accessories such as nuts, bolts, fasteners telescopic basket channels etc. Payment of providing and fixing telescopic channel shall be paid separately) |
| 37 | Flush pointing with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement for flat tile bricks on top of mud phaska. 14.18.1 with FPS bick tile. |
| 38 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun reflectivity index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/10 Sqm. One cat of self-priming of elastomeric water proofing liquid (dilution with water in the ration of 3:1 ) and two coats of undiluted elastomeric water proofing liquid (dry film thickness of complete application/ system not less than 500 microns). The operation shall be carried out after scraping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respects as per the direction of Engineer-in-charge. |