Tender For Provn Of Security Wall And Sentry Posts At Mankote Under Ge 881 Ews.; 1 Sch A Part-I(Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as Rs. 0.00 under col.5 signifies this fact only. 2 Construction of Block of Elevated Guard Post including steel ladder complete all as shown on drawings andas specified. 3 TotalAmount of Sch A Part - II (Internla Electric Supply Work) 4 TotalAmount of Sch A Part - III (Area Drainage Work) 5 TotalAmount of Sch A Part - IV (Protective Work) 6 TotalAmount of Sch A Part -V (Road, Path and Hard StandingWork) 7 TotalAmount of Sch A Part - VI (External Electric Supply Work) 8 TotalAmount of Sch A Part -VII (Security Wall Work) 9 Sch A Part - VIII (Misc Items of work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as Rs. 0.00 under col.5 signifies this fact only. 10 Punched tape concertina coil as per latest IS 6745-1972 with galvanised coating and punched type material as per IS deep drawn quality with galvanised coating having medium barbs fixed in position and secured to fence posts/straining Y- arm stretched to a length so as to achieve 600mm dia as in fencing including fixing with special galvanised fasteners such as J clips, C clips, U clips fixed at any height of security fence including necessary scaffolding complete all as directed.Size of Coil: 600mm dia and 2.5mm core wire thick.Type of strip: Heavy galvanised conforming to IS 1730 (1989).Type of core wire: Heavy galvanised conforming to IS 280-2006. Zinc coating to strip : 200GSM/SqmmZinc coating to line wire: 275 GSM/Sqmm (IS 6745- 1972 Reprint 2006)Tensile strength of wire: 1400-1500 N/Sqmm.Weight: 13.50 Kg/per coil (± 5% tolerance).Blade: 22mm Barb, profile: Medium blade (MBBT).Distance between barb: 35mm, Stretchable length of each coil: 10m, Type of clip: Hard and galvanised steel. 11 Time switches, 415 volts, threePhase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified. 12 FRP Junction box pole mounting box weather prooftype of size 155mm x 155mm x 100mm with four terminal and one 6 amps MCB mounted inside complete all as specified and directed. 13 PVC insulated, 1100 volts grade, stranded copper conductor cable 1.5Sqmm, 3 core, connecting from Street light junction box to light fittings complete all as specified and directed. 14 Double wall corrugated pipe (DWC) of 75mm dia conforming to IS: 16205 Part-24 and IEC 61386 (Part-24) for cable protection under/ above ground surface complete all as specified and directed. 15 Supply, installation, commissioning and testing of silent Diesel Engine Generating Set comprising of diesel engineliquid- cooled (latest IS and CPCB- Norms ) & alternator, of output capacity not less than 7.5KVA at site (DG Set to be installed at HAA 950m above MSL and capacity of DG set shall be selected, so as to deliver 7.5 KVA in all adverse conditions), 3 phase, 4 wire,415 V, 50 Hz., 0.8pfat 1500 RPM, with control panel having all necessary switch gears for automatic starting on main failure (AMF Panel), both coupled and aligned on a common base frame complete with standard accessories like MS Fueltank (having the minimum fuel capacity for running of DG set continously for 12 hours), AVM Pads fitted on base frame, Control Panel with digital measurement devices, alongwith accoustic enclosurewith the confirminationof latest BS/IS and complete in all respects Including lubricating oil filled in engine, DG Set Manual comprising of following complete as as specified:- 16 Prime Mover : Prime mover suitable for driving alternator 7.5 KVACapacity having the suitableBHP at 1500 RPMfor rated outputfor alternatorin accordance with latestBS/ISSpecificationwith electricstartingdevicewith all standardfittingsand suitable capacity of lead acid maintenance freebattery of 12 Volts as per manufracturer -01 noswith Battery andCharger Engine over speed safety mechanismshall be incorporated. The engine shall be equipped with standard fittings as per manufacturesrecommendations. Engine Control Panel : (a) All relevantparameters shall beconventionallydisplayed on complete panel thereby providingeasy monitoringof lub oil, pressure, Coolant Temperature, Battery charging, Ammeter, RPM, Hour meter and starting switch etc. (b) AMF Panel with Bye Pass arrangement for Mainand DG Both supply,internal wiring and power contactors suitable for 7.5 KVA generator set, all as per manufacturers recommendation. Bye Pass arrangement Main & DG set Supply along with all the parameters and accessories as permanufacturer recommendation and CPRI Approved & as per relevant IS.Fuel Tank: Fuel Tankof 12 hours capacity will be installed as per the manufacturersrequirementincludingall necessarypipe connections fromfuel tank to engineand over flow from engineto tank. 17 Engine Alternator Engine Alternator of capacity 7.5 KVA output 3 Phase 50 HZ 415 Volts 4 wire AC supply 0.8 Power Factor at 1500 RPM self regulated self excised screen protected and drip type, insulation class H continously rated brush less type conforming to relevant BS/ IS code as per current manufacturing shedule of standard manufacturer. Engine Alternator shall be mounted on specially designed base plate of rigid welded constructions with anti vibraton pads. The DG Set shall be placed on foundation including necessary civil works as per the manufacturers recommendations/site requirement. The output of alternator not less than 7.5 KVA in all adverse conditiones, as the DG set to be installed at HAA 950 m above MSL. Note:- (a) The unit rate shall deemed to include the cost of Diesel and lubrication required for testing and commissioning of DG Set as per department procedure and shall be arranged by contractor.(b) Extenssion of exhaust pipe for DG setalong with standerd accessories like flange, nut bolts , asbestous rope etc. shall be provided by the contractor and the cost of the same shall be included in the unit rate quoted by contractor.(c) Cost of PCC foundation and necessary civil works as per the manufacturers recommendations/site requirement shall be incuded in the unit rate quoted by the contractor. 18 Earthing complete with galvanized steel earth plate electrode 600mmx600mmx6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32x6mmas earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC covermade out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle andangle iron (40x40x5)mm frame, GI medium grade watering pipe 20 mm bore and GI light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. 19 Supplying,installing and commissioning of Feeder pillar boxmade of angle iron 65mmx65mmx6mm on all side welded to 3.15mm thick CRCA steel sheet powder coated, outdoor type, IP-66 protection, confirming to IS 13947/IEC 60947 with openable shutters on both sides (Front and rear) having locking arrangement totally enclosed weather proof, danger notice sticker complete suitable for 440 volts, 3 phase, 4 wire, 50 Hz, with properly insulated colour coded aluminium bus bar, AC supply, Current transformer, selector swtch, Multi Function Metres, LED type indicator lamps, timers, contactors etc. electrically connected complete as per norms and fitted with providing the following. Incoming :-(i)MCCB 415 Volts of capacity 63 Amps 25 KA, 4 pole - 01 No (Incoming from Main LT Panel)Bus Bar :-(i)01 set of 200 Amps, TPN, Aluminium Bus bars(ii) ON Load change over switch 415V, 4 pole of capacity 63 Amps - 01 No(iii)MCCB, 415Volts of capacity 32 Amps 25 KA - 03 No(Outgoing 02 & 01 spare)(iv)MCB, SPN, 240 Volts of capacity 10 Amps 10 KA - 05 No(Outgoing 04 & 01 spare)(v) 3 phase multifunction metrer(vi) LED indicator lamp –01 No (set of three) 20 Notes :-(i)General arrangement and schematic drawings to be approved by the Deptt before start of fabrication.(ii)All MCCB shall have adjustable overload, short circuit, earth fault with adjustable time delays and instantaneous short circuit. All MCCB shall have ICS = 100% ICU & Each MCCBs having seperate enclosures.(iii)Set of Current transformer, selector switch, Multi Function Metres etc. as per incoming and outgoings. (iv)All CTs and PTs shall be cast resin type.(v)All indicator lamps should be of LED type.(vi) The height of panel should be 0.60 mtr from ground level with PCC foundation and the cost for foundation is deemed to the quoted rate. 21 3mm dia galvanised steel wire, 150mmx100mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling, complete all as specified and directed. 22 Pre moulded bitumen impregnated fiberboard (50mm thick) conforming to IS 1838 (Part-I) in expantion joints including cutting to shape fixing in position with sealent and finishing the surface complete all as specified and directed. 23 Point wiring for One light point/fan point controlled by one switch 5 Amp single pole one-way complete with 1.5 Sqmm (nominal area) PVC insulated, unsheathed and multi strand copper conductor FRLSH cable drawn into and including PVC concealed conduit (heavy duty) and conduit fittings including 1.5 Sqmm PVC insulated unsheathed and multi stranded copper conductor FRLSH cable as earth wire to common earth and connecting to earth dolly including cutting of chases/wall/floor and suitable size of powder coated CRCA mild steel sheet modular sunken box for fixing switches, sockets, regulators with frame and top modular cover plateand machine made brass screw and washers etc complete all as specified and directed. 24 All as Per Srl item No. 19.00 above but for one 2/3 pin, 5 amp socket on same board. 25 Point wiring for power point control by one switch with 2.5 Sqmm nominal area PVC insulated single core multi standard copper conductor FRLSH insulated and undheathed heavy duty cable in colour code including earth wire with cable of size 2.5 sqmm copper conductor flexible FRLSH insulated drawn into and including concealed in PVC conduit of not less than 20mm dia and 1.5mm wall thickness (ISI marked) terminated into annealed steel terminal boxes including modular frame and cover plate for fixing of switches, sockets etc; complete all as specified and as directed. 26 LED batten suitable for indoor application 20W, 4 feet length, wall mounted with polycarbonate housing, end cap made of ABS plastic of white colour finish and high efficiency translucence (HET) diffuser and integral electronic driver including two point surface mounting on wall and connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified. 27 Dismantling smart fencing of any size including post, concertina coil, razor wire, nut bolt etc at any location or in any type of soil/concrete, including taking out embedded portaion and making good disturbed ground complete and refixing the dismantled smart fence at old/new location incuding post, razor wire, concertina coil, Y angle etc; in proper shape and layout using nut, bolt etc; complete all as specified and directed.