Tender For Provn Of Solid Waste Management (Swm) At Shillong Under Ge Shillong.; 1 Demolition of PCC block masonry, brick work or stone masonry built in cement mortar including all quoins arches, pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles, all asspecified . 2 Excavation in post holes (or similar holes) each in soft/loose soil n. exc. 0.5 cum, getting out, returning filling in an ramming earth or broken rubble mixed with earth around, in layers n. exc. 25 cm, watering and removing surplus soil to a distance not exc. 50 M and making good complete all as specified. 3 Excavation over area in soft/loose soil exc 1.5m wide and exc 1.5m in depth and getting out in soft/loose soil 4 Returning, filling in, including, spreading, leveling, watering and well ramming in layers n.exc 25cm. 5 Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed. 6 S&F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified 7 S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. 8 S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed. 9 M&L Cement concrete type D2 1:4:8 (40mm graded aggregates) in foundations, filling and mass concrete complete all as specified and directed. 10 M&L for PCC (1:3:6) type C2 using 40mm graded aggregates as in footpath, foundations,filling and mass concrete or any other directed and specified by Engr-in-Charge 11 M&L for PCC (1:2:4) type B2 using 40mm graded aggregates as in footpath, foundations,filling and mass concrete or any other directed and specified by Engr-in-Charge 12 M&L for PCC (1:3:6) type C2 using 40mm graded aggregates as in surface channel and drain, complete all as specified and as directed including demolition of old PCC as in surface channel and drain. 13 M&L RCC 1:1.5:3 (20mm graded aggregates) drain cover slabs including necessary forms/moulds supported on side walls complete all as specified. 14 S&F round bars/TMT steel bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for fencing, columns, beams, etc. hooking ends and binding with MS wire (annealed not less than 0.9mm dia) all as specified and directed. 15 Formwork to sides of concrete foundations,drains, footings, bases of columns, raft and fafts beams, sides and soffits (if any) of fdns and plinth beams, and similar works and fair finished surface complete all as specified and directed. 16 M&L forming 12mm thick expansion joints in 100mm thickness of concrete slab filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ complete all as specified and directed. 17 M&L Preparation of new steeland iron surfacesexceeding 10 cms width or girth and applying two coats of synthetic enamel paintoveronecoat of red oxide primer, all as specified. 18 M&L PCC 1:3:6 type C1(20mm graded aggregate) as in pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in 1:4 cement mortar complete all as specified and directed. 19 M&L formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for finished surfaces complete all as specified and as directed by Engr-in-charge. 20 M&L formwork to Square, rectangular or polygonal sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed. 21 M&Lwalling of Random rubble , uncoursed, well bonded, bedded and solidly hearted built in cement mortar 1:4 complete all as specified and directed. 22 M&L raised pointing to random rubble stone masonary uncoursed or brought upto course in cement mortar 1:3 complete all as specified and directed. 23 M&L for 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints ,laid in trenches or in floors complete all as specified and directed. 24 S&F PVC (SWR) bends 110mm dia complete all as specified and as directed 25 M&L for 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints ,laid in trenches or in floors complete all as specified and directed. 26 S&F 75mm bore PVC (SWR) bends any radius complete all as specified and directed. 27 S&F PVC(SWR) 75mm dia vent cowls complete all as specified and directed. 28 Surface dressing n exc15 cm deep in soft/loose soil complete all as specified and directed. 29 M&L broken bricks hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. 30 M&L prepairing old wall surfaces by washing rubbing down and stopping of distempered or any painted surfaces and priming with alkali resistant primer and applyingtwo coats of cement base paint complete all as specified and directed. 31 M&L complete removal existing treatment on wall and applying two coat of distemper oilemulsion on walls white or tinted complete all as specified and directed. 32 M&L preparation of new wall surface or untreated surface and applying two coat of distemper oil emulsion on walls white or tinted over a coat ofalkaliresistant priming paint complete all as specified. 33 M&L two coat of cement paint over a coat of with alkali resistant primer, white or tinted over new surface or previously untreated surfaces complete all as specified and directed. 34 M&L precast cement concrete block massonry with solid blocks nexc 10 cm in width and settings in CM 1:4 type C1 1:3:6 (20mm graded aggregate) complete all as specified and directed. 35 Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete, all as specified. 36 M&L for Rendering 10mm thick on fair faces of concrete surface of wall in CM (1:6)finished even and smooth without using extra cement all as specified and directed 37 M&L for Rendering 10mm thick on fair faces of concrete surface of wall in CM (1:4)finished even and smooth without using extra cement all as specified and directed 38 M&L for neeru finish to plastering complete all as specified and directed. 39 S&F 1.25 mm thick mild steel sheet as in eaves gutters, galvanised class 3, half round with rounded edges complete all as specified and directed. 40 Material and labour point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one wayswitch using1.5 sqmm nominal cross sectional areamultistrandedcopper conductor ,PVC insulated unsheathedFRLSH cables in and including suitable size PVC casing caping or concealed conduit and fittings of medium grade, including pressed steel / PVC terminal switch boxes fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectional area multistranded copper conductor FRLSHPVC insulated unsheathed earth wire and connecting to earth dolly andbrass screws, washers etc. complete all as specified and directed. 41 Description all as per Srl item No. 40 here in before but for socket outlet point 5 Amp on same board. 42 Description all as per Srl item No. 40 here in before but with 2.5 Sqmm cable for socket outletpoint 5 Amp on Independent board. 43 Description all as per serial item No. 40 above but with 4 sqmm cablefor 3 pin 15 Amps switch socket outlet (Power point) complete all as specified. 44 Supply and fix switch piano flush type, single pole , 5/6 Amps, one way complete all as specified. 45 Supply and fix switch socket combination 2 in 1 multipurpose5 pin , (6 Amps ) flush typecontrolled by one switch complete all as specified. 46 Supply and fix socketoutlets 2 in 1, 3 pin, 5/6 Amps flush type230/240 V complete all as specified and as directed. 47 Supply and fix switch socket combination5 in 1 , 6 pin , (5/16 Amps ) flush typecontrolled by one switch complete all as specified. 48 Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified. Make:Cona , Plaza, Anchor . 49 Supply and fixing LED batten fittings 1x18 Watt complete pre wired fixed to wallwith 2 nos PVC block of suitable size including taking down old unserviceable one. 50 S&F lamp holder, insulated body, with back plate for batten fittingcomplete. Make- Havells/anchor/Legrand. 51 Supply and fix ininverter LED bulb 20 Watt B22 base Color complete including taking down old unserviceable one all as directed. MAKE: philips, surya,crompton, or havells 52 S & F Exhaust fan 230 volts , 250mm,plastic body includingmaking all electric connection complete all as specified and as directed including cutting of hole on wall and makng good disturbed surface of wall and outer wooden box for fan fix on wall. 53 Supply and fix in repairs MCB DB 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified. 54 Supply and fix in repairs MCB Distribution board , 240 volts single pole andneutral ,double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed. 55 Supply and fix MCCB TPN, 240 Volts, 100Amps, 10 kA rupturing capacity415 Voltscomplete all as specified and directed including taking down old one. 56 Supply and fix MCB DP, 240 Volts, 40 Amps, 10 kA rupturing capacity C seriescomplete all as specified and directed including taking down old one. 57 Supply and fix in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DBs 58 M & L Sub main wiring with two run single core 6 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia concealed on wall/ceiling inISI markedwith all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc complete all as directed.Note: (i) Two runs of 6 sqmm and one run of 6 sqmm cable and one run of PVC conduitshall be measured as one RM. 59 Material and labour for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways andone handle for lifting made out of 8 mm dia TMTbar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I. 60 Supply, lay in trenches, floors ,fix on wall/pole, passing through pipes etc.,LT UG cable , 1100 volts grade, PVC/ XLPE insulated , with multistrandedaluminium conductors, armoured with galvanised steel wire or tape ,gland, lugs etc, of size 16 Sq.mm 4 core , confirming to IS specifications:- 61 Excavation in trenches not exc 1.5 m wde and 1.5 m deep for taking out/laying of UG cable/GI pipe of anydismeter in soft/loose soil and getting out complete all as specified and directed 62 Returning and filling including spreadking levelling watering and well ramming in layers not exc 25 cm thick soft/loose soil complete all as specified and directed 63 Removing excavated material at a distance n exc 50m and deposited where directed at a level not exc 1.5 above the starting point for soft/lose soil complete all as specified and directed 64 M & L for sand filing in treances for providing sand cushion for protection of UG cable complete all as specified and directed. 65 Supply and laying of sub class B bricks locally available alying perpendicular of UG cable complete all as specified and directed. 66 SITC of bailing pressure machine, 15 tone pressure capacity vertical hydraulic, single chamber, single cylinder bailer machine of size 24 (L) x 18 (W) in inch, 3 HP motor, 3 phase 1440 RPM 50 Hz complete all as specified and as directed. Make:- As approved by GE. 67 Supply only Enklo* 68 hydraulic oil. 68 SITC of Belt waste segregation conveyor machine structure body frame with 3 phase motor 5HP Capacity, RPM 1450, play with head pulley, tail pulley, rollerswith gear box of length 12m, rubber belt size 3ft and belth thickness 08mm complete all as specified and as directed. Make:- As approved by GE. 69 SITC inclined belt waste conveyor machine having load capacity upto 200Kg structure body frame with 3 phase motor 5HP Capacity, RPM 1450, play with head pulley, tail pulley, rollerswith gear box of length 12m, rubber belt size 3ft and belth thickness 08mm complete all as specified and as directed. Make:- As approved by GE.